• Title/Summary/Keyword: 3MS

Search Result 6,265, Processing Time 0.031 seconds

Clinical Effect of MS Coat and Elmex gel on the Dentin Hypersensitivity following Periodontal Surgery (치주수술 후 지각과민증에 대한 MS Coat와 엘멕스 겔처치의 임상적 효과)

  • Park, Sung-Min;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.727-736
    • /
    • 2001
  • Dentinal hypersensitivity is one of the complicated symptom rather than a disease. It has special reaction or pain over uncovered root by heat, mechanical or chemical stimulations, which are normal with healthy teeth, The purpose of this study is to discover rather MS Coat (oxalate-containing pre-polymerized resin suspension) or Elmex gel(amine fluoride+sodium fluoride) is effective on hypersensitivity after periodontal treatment using NRS(Numerica1 Rating Scales), which it is useful for evaluating pain level. This study has been prepared in Dankook Dental Hospital with generally healthy adult who had been suffered from dentinal hypersensitivity after periodontal treatment. Divided in three groups with saline(control group), MS Coat(test 1 group) and Elmex gel(test 2 group). And then, following evaluations were made at the end of 1 minute, 1 week, 1 month and 3 months. 1. The sequence of higher frequency & severeness of hypersensitivity is water within $7^{\circ}C$, air stream & explorer. 2. As time goes on, 1 minute, 1 week, 1 month & 3 months, severeness of hypersensitivity scored lower with water, air stream and explorer. 3. With explorer, the differences among three groups as time had to seen. 4. With air stream, the sensitivity scored lower after 1min with MS Coat, Elmex, and saline sequence. As time goes on the sensitivity was lower with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. 5. With water in $7^{\circ}C$, the sensitivity was much decreasing with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. As the result, MS Coat and Elmex are effective on hypersensitivity caused by periodontal treatment.

  • PDF

Association between Metabolic Syndrome and Physical Fitness in Postmenopausal Women

  • Ku, Min-Ju;Shin, Kyung-A;Ko, Kwang-Jun;Oh, Jae-Keun
    • Biomedical Science Letters
    • /
    • v.18 no.1
    • /
    • pp.63-70
    • /
    • 2012
  • The research is performed in order to know the relationship between the metabolic syndrome and the physical fitness targeted for menopausal women (over 45 years). All subjects were divided into 4 groups; group without risk factors of metabolic syndrome (MS-0: n=74), group having one risk factor of metabolic syndrome (MS-1: n=68), group having two risk factors of metabolic syndrome (MS-2: n=44), and group having more than three risk factors of metabolic syndrome (MS ${\geq}$ 3: n=30). All groups' height, weight, body mass index and percent of body fat were measured. High density lipoprotein cholesterol (HDL), triglyceride, glucose and blood pressure (BP) levels were measured. Their cardiorespiratory ($VO_2max$) endurance, muscular strength, muscle endurance, and flexibility were measured. HDL, triglyceride, glucose and BP levels in MS-1, MS-2, and MS ${\geq}$ 3 group were significantly greater than those of MS-0 group. The endurance ($VO_2max$) in MS ${\geq}$ 3 group was higher than that of MS-0 group. Multiple regression with the risk factors of metabolic syndrome and the physical fitness showed a statistical significance in only $VO_2max$. We found that the risk factors of the metabolic syndrome adversely affect postmenopausal women's $VO_2max$ and that a decreased $VO_2max$ may have prognostic value for the prediction of metabolic syndrome.

Multiple Shoot Induction on the New Cltivar, Saxifraga fortunei 'Greenstar' by Different Media and Plant Growth Rregulators (배지 및 생장조절제 종류를 이용한 바위떡풀 신품종 '그린스타' 의 다신초 유도)

  • Suh, Jong-Taek;Ryu, Seung-Yeol;Yoo, Dong-Lim;Nam, Chun-Woo;Hur, Youn-Young
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.2
    • /
    • pp.83-86
    • /
    • 2010
  • This study was conducted to develop in vitro propagation techniques of new cultivar, 'Greenstar', bred by Highland Agriculture Research Center. The multiple shoot induction and plant growth of in vitro plant were analyzed by MS media concentration (1/2 MS, 1 MS and 2 MS medium), plant growth regulators and its proper concentration; CPPU [Forchlorfenuron(N-(2-chloro-4-pridyl)-3-phenylurea) (0, 0.5, 1.0 and $2.0mg{\cdot}L^{-1}$), thidiazuron [(TDZ), (0.01, 0.1, 0.5 and $1.0mg{\cdot}L^{-1}$), zeatin (0, 0.5, 1.0 and $2.0mg{\cdot}L^{-1}$), and BA [6-benzylaminiopurine(BA), (0, 0.5, 1.0 and $2.0mg{\cdot}L^{-1}$)] in MS (3% sugar and 0.8% agar with pH 5.7) media. The highest number of induced shoots, leaves and roots were shown in 1/2 MS medium concentration. On the 1/2 MS medium, shoot numbers, shoot length, leaf numbers and root numbers were 11.0, 1.9 cm, 24.7, and 8.0, respectively. On the absence of CPPU in the 1/2 MS medium, shoot length and root numbers was greater than CPPU treatment, but the highest number of shoots was induced by the $2.0mg{\cdot}L^{-1}$ of CPPU concentration in 1/2MS medium. TDZ, zeatin, and BA treatments were not effective on the induction of multiple shoot in vitro culture. As a result, in vitro culture of new Saxifraga fortunei, 'Greenstar' with $2.0mg{\cdot}L^{-1}$ of CPPU in 1/2 MS medium was most effective for the rapid multiplication.

A Study on the Characteristics of MS Delay Blasting Considering Cooperating Charge (협동장약을 고려한 MS 지발 발파 특성 연구)

  • Kang Choo-Won;Kim Jong-In;Park Joung-Bong
    • Explosives and Blasting
    • /
    • v.23 no.3
    • /
    • pp.11-18
    • /
    • 2005
  • The waveform at the blasting pattern using k13 delay electronic detonator depends on the interference of adjacent delay time according to the degree of distance and frequency. The degree of interference affects the size of blasting vibration at a measuring point. This study analyzed the cooperating change characteristics of MS delay blasting separately detonated at intervals of 40m and presented through frequency the delay time design method that is able to reduce the cooperation of blasting vibration at the MS delay blasting.

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.

A Study on the Characteristics of Echolocation Signals of the Common Dolphin, Delphinus Delphis (참돌고래의 반향정위 신호특성에 관한 연구)

  • 신형일;윤갑동;신현옥;최한규;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.189-195
    • /
    • 2001
  • The characteristics of echolocation signals of the Common Dolphin, Delphinus Delphis was observed by the hydrophone in order to detect exactly distribution and migration on whales and dolphins in Korean Coastal waters. It's observation was carried out at the position of 13 mm off Gam-Po of Korean east-southern sea at 3rd-5th. April and 13th-15th. October, 1999. The results obtained are summarized as follows: (1) The frequency range of ship's noise and ambient noise in the observed station was 0.5-0.3 kHz, that ones could be influenced to the behavior of common dolphins which carry out echolocation using low-frequency. (2) The common dolphin was radiated single click of 8.6 ms and double click of 4.8 ms pulse width during these observation (3) The high click frequencies of common dolphin were 5.10 kHz, 7.22 kHz, 10.60 kHz with the click pulse width of 4.0 ms, 2.6 ms, 1.0 ms, respectively. In case of low-frequency 1-2 kHz, that is, 1.12 kHz, 1.38 kHz, 1.82 kHz, pulse width were 22.4 ms, 2.05 ms, 11.9 ms, respectively and they showed a tendency using triple click signal. (4) The pulse width, pulse recurrence interval and frequency range of the observed echolocation signals were 2.4-8.4 ms, 9.0-40.0 ms, 0.60-10.63 kHz respectively, and frequency spectrum level was 100-125 dB for single, double, triple click signals.

  • PDF

Effects of Herbal Medicine on Breastfeeding - Analysis of Marker Substances in Saenghwa-tang by HPLC and LC/MS/MS - (산모의 한약 복용이 모유에 미치는 영향 - HPLC와 LC/MS/MS를 이용한 생화탕 지표성분 분석 -)

  • Park, Ka-Young;Lee, Ah-Young;Ban, Ji-Hye;Park, Jung-Kyung;Lee, Eun-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.48-65
    • /
    • 2013
  • Objectives: We took breast milk samples and analyzed them using HPLC and LC/MS/MS, to evaluate the effects of taking Saenghwa-tang during breastfeeding on breast milk. Methods: The study participants were 20 lactating women who admitted in Korean medical postpartum care center. Breast milks were collected from paticipants who have been administrated Saenghwa-tang for more than 3 days. We used HPLC and LC/MS/MS for the determinations of amygdalin, liquiritins, 6-gingerol, decursin and decursinol angelate in Saenghwa-tang. Results: 1. Participants' $Mean{\pm}S.D$ (standard deviation) of age is $31.05{\pm}1.96$, and 15 participants had normal delivery and 5 participants had cesarean delivery. 12 participants were primipara and 8 participants were multipara. $Mean{\pm}S.D$ of lactating date is $9.4{\pm}0.94$. 2. Using HPLC, we learned LOQ level peak that matches the peak retention time of standard components of Saenghwa-tang was not detected from 20 breast milk samples. 3. Using LC/MS/MS, decursin of Angelicae Gigantis Radix was detected from HMSP 02, HMSP 04, HMSP 06, HMSP 11, and the each concentrations are 16, 2, 64, 11 ppb. Liquiritin of Glycyrrhizae Radix was not detected from HMSP 13~HMSP 18. Conclusions: Data obtained by this approach shows that this method is reliable and suitable for determining the safety of taking Saenghwa-tang during breastfeeding.

Analytical Characteristics of GC/MS and HPLC according to the Concentration Distribution of PAHs (PAHs 농도 분포에 따른 GC/MS와 HPLC의 분석특성에 관한 연구)

  • Hong, Jwa-Ryung;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.312-321
    • /
    • 2015
  • Objectives: The purpose of this study was to determine the best method to analyze PAHs at extremely low concentrations. To this end, 16 PAHswere analyzed simultaneously by GC/MS, HPLC/FLD and HPLC/UVD, and the analytical characteristics of HPLC and GC/MS were compared. Methods: This study was conducted by GC/MS and HPLC/FLD/UVD, and evaluated linearity, precision and detection limit. Standard solutions were prepared for 21 samples in the range of $0.00001{\sim}1.0{\mu}g/mL$ and the samples were divided into four groups. All samples were made in three sets and analysis was replicated seven times. Results: Sixteen PAHs could be simultaneously separated by HPLC and GC/MS, and the adequate equipment was HPLC/FLD. The retention times by HPLC were shorter than GC/MS, and HPLC had better separation for most PAHs than GC/MS. The peaks of naphthalene and naphthalene-D8 partially overlapped for GC/MS. HPLC/FLD had a 20-2000 times lower limit of detection than GC/MS and UVD. However FLD was not adequate for analyzing acenaphthylene because it has too low a fluorescence quantum yield to be detected. The precision of HPLC/FLD/UVD and GC/MS showed less than 20% at $0.001{\mu}g/mL$ PAHs and when the concentration was higher, the coefficient of variation was decreased. HPLC/FLD was better for the overall detection of limits. Conclusions: The results indicate that the HPLC/FLD method has good linear range, precision and a detection of limits from $0.00001{\sim}0.0001{\mu}g/mL$ for all 16 PAHs. This study contributes to providing useful data for analysis technology and can be applied to occupational exposure measurement for PAHs in workplaces.

Rapid Quantitative Analysis of Vancomycin in Human Plasma and Urine Using LC-MS/MS (LC - MS/MS를 이용한 혈장과 뇨중에서 Vancomycin의 빠른정량분석)

  • Kim, Hohyun;Roh, Hyeongjin;Han, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.410-416
    • /
    • 2002
  • In this study, a new quantitative analytical method has been developed for the rapid determination of vancomycin in human plasma and urine using liquid chromatography/tandem mass spectrometry (LC - MS/MS). Chromatography was carried out on a $C_{18}$ XTerra MS column ($2.1{\times}30mm$) with a particle size of $3.5{\mu}m$. The mobile phase was 0.25% formic acid in 10% acetonitrile and the flow rate was $250{\mu}L/min$. Vancomycin and caffeine (internal standard) were detected by MS/MS using multiple reaction monitoring (MRM). Vancomycin gives a predominant doubly protonated precursor molecule ($[M+2H]^{2+}$) at m/z 725.0 and a corresponding product ion of m/z 100.0. Detection of vancomycin was good, accurate and precise, with a limit of detection of 1 nM in plasma. The calibration curves for vancomycin in human plasma was linear in a concentration range of $0.01{\mu}M$ - $100{\mu}M$ for plasma. This method has been successfully applied to determine the concentration of vancomycin in human plasma and urine from pharmacokinetic study and relative studies.