• Title/Summary/Keyword: 3DIC

Search Result 100, Processing Time 0.025 seconds

Development of a multi-sensing technique for temperature and strain field of high-temperature using thermographic phosphors (온도감응형 인광물질을 이용한 온도장 및 열변형 동시 계측 기법 개발)

  • Im, Yujin;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • Solid oxide fuel cell (SOFC) operates at high temperatures in range of 600-800℃. Since layers of SOFC are composed of different substances, different thermal expansion in SOFC can result in defects under high temperature conditions. For understanding relation between temperature field and the thermal deformation in SOFC, temperature and strain field were simultaneously estimated using thermographic phosphors by optical measurement. Temperature fields were obtained by the life-time method, and the temperature differences of one specimen was checked with thermocouple. The thermal deformation was estimated by digital image correlation (DIC) method with extracted phosphorescence images. To investigate the deformation accuracy of DIC measurement, thermographic phosphors were coated with and without grid pattern on aluminum surface. Simultaneous measurement of temperature fields and thermal deformation were carried out for YSZ. This study will be helpful to multi-sensing of temperature field and thermal deformation on SOFC cells.

Parapinnanema imbricatum Belogurov, Belogurova and Smolyanko, 1985(Nematoda: Chromadoridae) from Ulleungdo Island, the East Sea, Korea

  • Woo In Jung;Won Gi Min;Hyun Soo Rho
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.4
    • /
    • pp.616-626
    • /
    • 2023
  • In May 2023, a free-living marine nematode species from the genus Parapinnanema was identified in the subtidal zone of Ulleungdo Island, the East Sea, Korea. Specimens were collected using the Smith-McIntyre Grab. These specimens exhibited close similarities to Parapinnanema imbricatum from the sublittoral of Moneron Island, particularly in terms of general characteristics, such as the detailed structure of the buccal cavity, the complex and ringed structure of the cuticle, the copulatory apparatus, spinneret, and the female genital system. However, the Korean specimens of Parapinnanema imbricatum also displayed distinctive features compared to the original description, including a relatively elongated body (3,317-4,339 ㎛ vs. 3,100-4,200 ㎛) and a narrower body width (66-77 ㎛ vs. 71-85 ㎛). Additionally, the diameter of the head was relatively shorter(24-29 ㎛ vs. 28-36 ㎛). This paper offers a comprehensive morphological description, along with illustrations and DIC photomicrographs, of P. imbricatum from Korean waters.

Evaluation of Displacement Measurement Technique Using Laser Speckle and Digital Image Correlation Method (레이저 스페클과 디지털 화상관련법을 이용한 변위 측정방법의 평가)

  • 강기주;이정현;전문창
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.47-54
    • /
    • 2003
  • As a tool for strain measurement to work with screw driven or hydraulic material test systems, in which mechanical vibration is inherent, SSDG (Speckle Strain/Displacement Gage), ESP (Electronic Speckle Photography) and its 3-dimension version SDSP are evaluated for the theory and practical appliance. Through tension test of steel strips, their validity and shortcomings are examined. As the results, it has been shown that, although SSDG and ESP provide direct measurement of in-plane strain in one direction, they are so sensitive to the out-plane displacement. On the other hand, SDSP which is aided with DIC (Digital Image Correlation) technique to trace the movement of the speckles provides not only in-plane 2-dimensional displacement field, but also out-of-plane displacement simultaneously. However, because the DIC is time-consuming, not automated yet and it needs post-processing to evaluate strain from the displacement field, SDSP appears to be not adequate as a real time sensor.

Study on the Improvement of the Image Analysis Speed in the Digital Image Correlation Measurement System for the 3-Point Bend Test

  • Choi, In Young;Kang, Young June;Hong, Kyung Min;Kim, Seong Jong;Lee, Gil Dong
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.523-530
    • /
    • 2014
  • Machine material and structural strain are critical factors for appraising mechanical properties and safety. Particularly in three and four-point bending tests, which appraise the deflection and flexural strain of an object due to external force, measurements are made by the crosshead movement or deflection meter of a universal testing machine. The Digital Image Correlation (DIC) method is one of the non-contact measurement methods. It uses the image analyzing method that compares the reference image with the deformed image for measuring the displacement and strain of the objects caused by external force. Accordingly, the advantage of this method is that the object's surface roughness, shape, and temperature have little influence. However, its disadvantage is that it requires extensive time to compare the reference image with the deformed image for measuring the displacement and strain. In this study, an algorithm is developed for DIC that can improve the speed of image analysis for measuring the deflection and strain of an object caused by a three-point bending load. To implement this algorithm for improving the speed of image analysis, LabVIEW 2010 was used. Furthermore, to evaluate the accuracy of the developed fast correlation algorithm, the deflection of an aluminum specimen under a three-point bending load was measured by using the universal test machine and DIC measurement system.

Current-Voltage and Conductance Characteristics of Silicon-based Quantum Electron Device (실리콘 양자전자소자의 전류-전압 및 컨덕턴스 특성)

  • Seo, Yong-Jin
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.811-816
    • /
    • 2019
  • The silicon-adsorbed oxygen(Si-O) superlattice grown by ultra high vacuum-chemical vapor deposition(UHV-CVD) was introduced as an epitaxial barrier for silicon quantum electron devices. The current-voltage (I-V) measurement results show the stable and good insulating behavior with high breakdown voltage. It is apparent that the Si-O superlattice can serve as an epitaxially grown insulating layer as possible replacement of silicon-on-insulator(SOI). This thick barrier may be useful as an epitaxial insulating gate for field effect transistors(FETs). The rationale is that it should be possible to fabricate a FET on top of another FET, moving one step closer to the ultimate goal of future silicon-based three-dimensional integrated circuit(3DIC).

A Study for Accuracy and Usefulness of Tympanic Membrane and Forehead Thermometers (고막 체온계와 이마 체온계의 정확성 및 유용성에 대한 연구)

  • Yun, Gi Wook;Lim, In Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.820-825
    • /
    • 2005
  • Purpose : The presence and degree of fever in children is a useful indicator of illness. This project aimed to assess the accuracy and usefulness of infrared tympanic membrane(TM) & forehead feverscan thermometers for measuring children's temperatures. Methods : Data were obtained from 1,050 children with a median age of 4.5 years. They visited the pediatric clinics at Chung-Ang University Yongsan Hospital from January 2004 to December 2004. We measured body temperatures at axilla by mercury thermometer, at ear by infrared TM thermometer and at forehead by feverscan. Then we analyzed the correlation between these data. Results : Mercury and TM thermometer, and Mercury and forehead feverscan thermometer very well correlated with each others(P<0.05). And the sensitivity of infrared TM thermometer(right and left) to correctly identify febrile children was 81.1 percent and 82.4 percent, the positive predictive value to detect a fever was 81.8 percent and 73.6 percent. The sensitivity of forehead feverscan was 83.3 percent and the positive predictive value was 74.4 percent. Conclusion : The tympanic membrane temperature measured by the BRAUN IRT $3020^{(R)}$ and forehead arterial temperature measured by the HubDIC $DOTORY^{(R)}$ feverscan accurately reflects mercury axillary temperature, validly assesses the presence of fever in children, and is easy to use. The Braun IRT $3020^{(R)}$ & HubDIC $DOTORY^{(R)}$ therefore is an adequate tool to assess fever and may be used both in a clinical setting and for research purposes.

Effects of Single Fetal Death on Mother and Live Co-twin in Twin Pregnancy (쌍태 임신에서 일측 태아의 자궁내 사망이 산모와 생존아에 미치는 영향)

  • Kim, So Youn;Chung, Hae Yul;Back, Hee Jo;Choi, Ic Sun;Cho, Chang Yee;Choi, Young Youn
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1512-1518
    • /
    • 2002
  • Purpose : Twins have a higher mortality and morbidity than singletons. Co-twin with one fetal death is particularly at risk. We investigated the neonatal outcome of live co-twins when one fetus had died after the 20th gestational week, and associated risk factors. Methods : A retrospective study was performed in fifteen cases of twin pregnancy with single intrauterine fetal deaths after the 20th gestational week during the period from January 1996 to December 2000 at Chonnam University Hospital. Results : Gestational age was $33.7{\pm}3.2weeks$, birth weight was $1,992{\pm}592g$. Interval between one fetal death being detected and the delivery of a live co-twin was $32.4{\pm}29.5days$. There were 11 cases(73.3%) of premature babies less than 37 gestational weeks. Main causes of preterm delivery were preterm labor and premature rupture of membranes. Hematologic findings suggesting disseminated intravascular coagulopathy(DIC) were not found in all mothers before delivery, and was not associated with DIC and encephalomalacia of the live co-twin. Perinatal outcome of fifteen live co-twins was as follows : six were normal(40%), three were DIC(20.0%), three were encephalomalacia(20.0%), one suffered intrauterine growth retardation, there was one case of twin to twin transfusion syndrome, and one of congenital heart disease(atrial septal defect with pulmonary stenosis). The occurrence of DIC and encephalomalacia in live co-twins was not related to placental chorionicity, birth weight, gestational week, and the interval between the detection one fetal death and the delivery of a live co-twin. Conclusion : We could not find any maternal hematologic problems in twin pregnancies complicated by one fetal death. Twenty percent of live co-twins showed DIC and encephalomalacia. However, its associated risk factors were not found. We need to investigate more closely the cases of live co-twins with one intrauterine fetal death.

Creep of stainless steel under heat flux cyclic loading (500-1000℃) with different mechanical preloads in a vacuum environment using 3D-DIC

  • Su, Yong;Pan, Zhiwei;Peng, Yongpei;Huang, Shenghong;Zhang, Qingchuan
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.759-768
    • /
    • 2019
  • In nuclear fusion reactors, the key structural component (i.e., the plasma-facing component) undergoes high heat flux cyclic loading. To ensure the safety of fusion reactors, an experimental study on the temperature-induced creep of stainless steel under heat flux cyclic loading was performed in the present work. The strains were measured using a stereo digital image correlation technique (3D-DIC). The influence of the heat haze was eliminated, owing to the use of a vacuum environment. The specimen underwent heat flux cycles ($500^{\circ}C-1000^{\circ}C$) with different mechanical preloads (0 kN, 10 kN, 30 kN, and 50 kN). The results revealed that, for a relatively large preload (for example, 50 kN), a single temperature cycle can induce a residual strain of up to $15000{\mu}{\varepsilon}$.

Study of monolithic 3D integrated-circuit consisting of tunneling field-effect transistors (터널링 전계효과 트랜지스터로 구성된 3차원 적층형 집적회로에 대한 연구)

  • Yu, Yun Seop
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.5
    • /
    • pp.682-687
    • /
    • 2022
  • In this paper, the research results on monolithic three-dimensional integrated-circuit (M3DICs) stacked with tunneling field effect transistors (TFETs) are introduced. Unlike metal-oxide-semiconductor field-effect transistors (MOSFETs), TFETs are designed differently from the layout of symmetrical MOSFETs because the source and drain of TFET are asymmetrical. Various monolithic 3D inverter (M3D-INV) structures and layouts are possible due to the asymmetric structure, and among them, a simple inverter structure with the minimum metal layer is proposed. Using the proposed M3D-INV, this M3D logic gates such as NAND and NOR gates by sequentially stacking TFETs are proposed, respectively. The simulation results of voltage transfer characteristics of the proposed M3D logic gates are investigated using mixed-mode simulator of technology computer aided design (TCAD), and the operation of each logic circuit is verified. The cell area for each M3D logic gate is reduced by about 50% compared to one for the two-dimensional planar logic gates.

Study on the Measurement of Flexural Strain Using the Digital Image Correlation in the Three-Point Bending Test (이미지 상관법을 이용한 휨 변형률 측정에 관한 연구)

  • Choi, In Young;Kang, Young June;Hong, Kyung Min;Ko, Kwang Su;Lee, Hak Sung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.5
    • /
    • pp.498-504
    • /
    • 2014
  • Displacements and strains are very important for material evaluation as critical factors to a machine's life cycle and safety. Typically, the strain gauge has been employed to measure displacement and strain. However, this contact-type measurement method has disadvantages that are not quantified under the test conditions of a specific object shape, surface roughness, and temperature. In this paper, the measurement of deflection and flexural strain due to the three-point bending test is presented, employing Digital Image Correlation (DIC) methods. In order to ensure measurement reliability, DIC and universal test machine methods were compared by measuring the deflections and flexural strains developed by such bending tests.