• Title/Summary/Keyword: 3D-kinematics and kinetics

Search Result 11, Processing Time 0.028 seconds

The Influence of High-heeled Shoes on Kinematics and Kinetics of the Knee Joint during Sit-to-stand task

  • Park, Ji-Won;Kim, Yun-Jin
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.5
    • /
    • pp.304-310
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the change in the kinematics and kinetics of the knee joint depending on high-heeled shoes during sit-to-stand (SitTS) task. Methods: Nineteen healthy females participated in this study. The subjects performed the SitTS task wearing high-heeled shoes and barefoot. The experiment was repeated three times for each task with foot conditions. The kinematics and kinetics of the knee joint were measured and analyzed using a 3D motion analysis system. Results: The result of this study showed kinematic and kinetics differences in knee joints during the SitTS task based on high-heeled shoes. Significant differences in knee flexion angle were observed during SitTS. The knee extensor force showed statistically significant differences during SitTS tasks. At the initial of SitTS, the knee flexor and extensor moment showed significant differences. The knee extensor moment showed statistically significant differences at the terminal of SitTS. At the maximum of SitTS, the knee extensor moment showed statistically significant differences. Conclusion: Therefore, wearing high-heeled shoes during SitTS movements in daily life is considered to influence knee joint kinematics and kinetics due to the HH, suggesting the possibility of increased risk of patellofemoral pain, and knee osteoarthritis caused by changes in loading of the knee joint.

A Study for analysis of Inverse Kinematics system to Character Animations & Motion Graphics education

  • Cho, Hyung-ik;Shin, Seung-Jung
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.149-156
    • /
    • 2021
  • Today, 3D softwares have become an essential tool in all areas of Video, including Movies, Animations, CFs, Motion Graphics and Games. One of the most commonly used fields is the 3D character video part. However, these 3D character animations and motion graphics softwares are difficult to learn and too much to learn, making it difficult to learn them all in a university education with a limited time of four years. In this paper, many Inverse kinematics tools, which are essential in the 3D character animations and motion graphics field, compare and analyze the strengths and weaknesses of each tool, focusing on Bone, Character Studio, and Character Animation Toolkit, which are most commonly used in work fields. And use Delphi techniques for 3D experts to secure objectivity. Therefore, for universities that require large amounts of teaching in a limited time, I propose an analysis of which of the above three Inverse Kinetics tools is advantageous for students to select and focus on for efficient education.

The Influence of Unstable Shoes on Kinematics and Kinetics of the Lower limb Joints during Sit-to-stand task

  • Kim, Yun-Jin;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.14-21
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate examine how the kinematics and kinetics of lower limb joints were changed depending on the unstable shoes (US) during sit-to-stand task (SitTS). Methods: Nineteen healthy females were participated in this study. The subjects performed sit-to-stand task with US and barefoot. The experiment was repeated three times for each tasks with conditions. The kinematics and kinetics of lower limb joint were measured and analyzed using a 3-D motion analysis system. A paired t-test was utilised performed for to identificationy of changes in mean of angle, force, and moment between both the two conditions. Results: The results of this study showed kinematic differences in lower limb joints during SitTS based on the US. The hip, knee, and ankle angle showed statistically significant differences during SitTS. At the initial of SitTS, Tthe force and moment of the hip flexor, hip extensor, knee flexor, knee extensor, ankle flexor, and ankle extensor showed statistically significant differences. At the terminal of SitTS, Tthe force and moment of the hip flexor, hip extensor, knee flexor, knee extensor, ankle flexor, and ankle extensor showed statistically significant differences. At the maximum of SitTS, Tthe moment of the hip extensor showed statistically significant differences. The force and moment of the ankle flexor, extensor moment showed statistically significant differences. Conclusion: Therefore, Wwearing US is considered to influence on the lower limb joints kinematics and kinetics during SitTS movements, and thus suggests the possibility that of reducing the risks of pain, and osteoarthritis caused by changes in the loading of lower limb joints.

A Comparative Analysis of Kinematics and Kinetics on Forehand Drive in Squash (스쿼시 Forehand 드라이브 동작 시 운동역학적 비교연구)

  • Jin, Young-Wan;Park, Yang-Hee;Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.17-25
    • /
    • 2007
  • The purpose of the study is to give basic data for the improvement of the skill and to show an exemplary position for squash club members or trainers thru a comparative analysis on the kinematics and kinetics variables on the forehand drive motion in playing squash. The objects of the research are divided into two sections, skilled group(n=8) and unskilled group(n=8). The skilled group is composed of professional players currently working and unskilled group is career of six month, both of lives in B city. In this research, to gather the data 3D motion analysis and test result analysis using force platform was used. The variables are duration, position, segment velocity, segment acceleration and etc. in using force platform. The results are as follows: 1. The duration per phase of the skilled is 0.18sec P1(DS) while that of unskilled is 0.32sec. in P2(FT), the duration of the skilled is 0.29sec, that of unskilled is 0.34sec. Average of the duration of the skilled is 0.48sec, while the unskilled, 0.66sec. 2. Regarding positional movements per event, the unskilled has a relatively higher position in center of gravity, shoulder joint, elbow joint compared with that of the skilled. Generally speaking, positions of the unskilled is higher than the skilled. 3. In segment velocity per event, R-shank, R-upper arm, R-forearm and racket. The skilled is faster than the unskilled. we found a big dig difference in shank. 4. In acceleration per event, there was a big difference in upper-arm and fore-arm of the impact. 5. The skilled group on the force platform shows relatively stable and regular changes while the unskilled shows unstable from the touch down to initial 20% the force value of central support period after the impact moment decreases rapidly and the center of gravity is not moved well. 6. The maximum force value of the skilled is 1019.7N. it is found 19.86% of the total duration. That of the unskilled is 639.2N, it is found 20.67% of total duration.

Change in Kinetics and Kinematics during 1-Footed Drop Landing with an Increase in Upper Body Weight

  • Lee, Jin-Taek;David, O'Sullivan
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The purpose of this study was to investigate changes in kinetic and kinematic variables associated with an increase in upper body weight. Eighteen healthy male university students($175.96{\pm}4.19\;cm$, $70.79{\pm}8.26\;kg$) participated. Eight motion analysis cameras(Qualysis Oqus 500) and 2 force AMTI platforms(Advanced Mechanical Technologies Inc. OR6-7, US) were used to record motion and forces during the drop landing at a frequency of 120 Hz and 1200 Hz, respectively. QTM software(Qualisys Track Manager) was used to record the data, and the variables were analyzed with Visual 3D and Matlab 2009. For the drop landing, a box of $4{\times}2{\times}0.46\;m$ was constructed from wood. Knee and ankle maximum flexion angle, knee flexion angle, knee and ankle angle at landing, time for maximum ankle flexion after landing, and time for maximum knee flexion after landing were calculated. There was a significant change in the time for maximum and minimum ground force reaction and the time for maximum dorsal flexion after landing(p<.05) with increasing weight. There was no significant change for the hip, knee, and ankle ROM, whereas there was an increase in the angle ROM as the weight increased, in the order of ankle, knee, and hip ROM. This result shows that the ankle joint ROM increased with increasing weight for shock attenuation during the drop landing. There was a trend for greater ankle ROM than knee ROM, but there was no clear change in the ROM of the hip joint with increasing weight. In conclusion, this study shows the importance of ankle joint flexibility and strength for safe drop landing.

A Review of Motion Capture Systems: Focusing on Clinical Applications and Kinematic Variables (모션 캡처 시스템에 대한 고찰: 임상적 활용 및 운동형상학적 변인 측정 중심으로)

  • Lim, Wootaek
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.87-93
    • /
    • 2022
  • To solve the pathological problems of the musculoskeletal system based on evidence, a sophisticated analysis of human motion is required. Traditional optical motion capture systems with high validity and reliability have been utilized in clinical practice for a long time. However, expensive equipment and professional technicians are required to construct optical motion capture systems, hence they are used at a limited capacity in clinical settings despite their advantages. The development of information technology has overcome the existing limit and paved the way for constructing a motion capture system that can be operated at a low cost. Recently, with the development of computer vision-based technology and optical markerless tracking technology, webcam-based 3D human motion analysis has become possible, in which the intuitive interface increases the user-friendliness to non-specialists. In addition, unlike conventional optical motion capture, with this approach, it is possible to analyze motions of multiple people at simultaneously. In a non-optical motion capture system, an inertial measurement unit is typically used, which is not significantly different from a conventional optical motion capture system in terms of its validity and reliability. With the development of markerless technology and advent of non-optical motion capture systems, it is a great advantage that human motion analysis is no longer limited to laboratories.

The Effects of Cryoprotectants on Motility and Viability Kinetics of Liquid Boar Semen at $4^{\circ}C$ (액상 보존액 내 동결 보호제가 $4^{\circ}C$에 보관된 액상 돼지 정액의 운동성과 생존성에 미치는 효과)

  • Jeon, Yu-Byeol;Park, Kwang-Woo;Kwak, Seong-Sung;Jeong, Seung-A;Yoon, Jun-Chul;Hyun, Sang-Hwan
    • Journal of Embryo Transfer
    • /
    • v.27 no.1
    • /
    • pp.51-55
    • /
    • 2012
  • The objective of this study was to investigate the motility and kinematics of boar sperm that while stored at 4C. The samples of fresh boar semen were place into an extender, Androhep, and stored at $4^{\circ}C$. In three of these samples, cryoprotectants were added. The sperm's motilities and kinematics were evaluated by using microscope (${\times}400$) and the viability status was evaluated by using with eosin staining method. The 5 sample groups are; Goup A:Androhep (extender), stored at $17^{\circ}C$. Group B:Androhep (extender), stored at $4^{\circ}C$. Group C:Androhep (extender), + 3% glycerol (cryoprotectant), stored at $4^{\circ}C$. Group D:Androhep (extender), + 3% DMSO (cryoprotectant), stored at $4^{\circ}C$. Group E:Androhep (extender), + 3% ethylene glycol (cryoprotectant), stored at $4^{\circ}C$. In group A, the sperm's motility was reduced. On day one the sperm's motility was ($85.7{\pm}2.3$) and day 5 the motility was ($43.9{\pm}3.3$). In group B, C and D the sperm's motility were reduced to 0 on day 5. In group E the sperm's percentage of motility decreased. On day one the sperm's motility was ($42.0{\pm}0.5$) and day 5 the motility was ($2.3{\pm}0.3$). When comparing cryoprotectant in samples of boar sperm there is a slight improvement in the results when the use of Androhep Lite (extender), + 3% ethylene glycol (cryoprotectant), stored at $4^{\circ}C$ are used. Based on these results, ethylene glycol can protect sperm from heat shock at $4^{\circ}C$, but not satisfactory level. However, it showed the possibilities of liquid semen preservation at $4^{\circ}C$ by using cryoprotectant.

Biomechanical Analysis of Walking and Running after a Surgically Repaired Achilles Tendon Rupture (아킬레스건 파열 수술 후 걷기 및 달리기 운동역학적 분석)

  • Heo, Jeong;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.241-248
    • /
    • 2021
  • Objective: The purpose of this study was to investigate the difference in muscle strength, kinematics, and kinetics between injured and non-injured sides of the leg after Achilles Tendon Rupture surgery during walking and running. Method: The subjects (n=11; age = 30.63 ± 5.69 yrs; height = 172.00 ± 4.47 cm; mass = 77.00 ± 11.34 kg; time lapse from surgery = 29.81 ± 10.27 months) who experienced Achilles Tendon Rupture (ATR) surgery participated in this study. The walking and running trials were collected using infrared cameras (Oqus 300, Qualisys, Sweden, 100 Hz) on instrumented treadmill (Bertec, U.S.A., 1,000 Hz) and analyzed by using QTM (Qualisys Track Manager Ver. 2.15; Qualisys, U.S.A). The measured data were processed using Visual 3D (C-motion Inc., U.S.A.). The cutoff frequencies were set as 6 Hz and 12 Hz for walking and running kinematics respectively, while 100 Hz was used for force plate data. Results: In ATR group, muscle strength there were no difference between affected and unaffected sides (p> .05). In kinematic analysis, subjects showed greater ROM of knee joint flexion-extension in affected side compared to that of unaffected side during walking while smaller ROM of ankle dorsi-plantar and peak knee flexion were observed during running (p< .05). In kinetic analysis, subjects showed lower knee extension moment (running at 2.2 m/s) and positive ankle plantar-flexion power (running at 2.2 m/s, 3.3 m/s) in affected side compared to that of unaffected side (p< .05). This lower positive ankle joint power during a propulsive phase of running is related to slower ankle joint velocity in affected side of the subjects (p< .05). Conclusion: This study aimed to investigate the functional evaluation of the individuals after Achilles tendon rupture surgery through biomechanical analysis during walking and running trials. Based on the findings, greater reduction in dynamic joint function (i.e. lower positive ankle joint power) was found in the affected side of the leg compared to the unaffected side during running while there were no meaningful differences in ankle muscle strength and walking biomechanics. Therefore, before returning to daily life and sports activities, biomechanical analysis using more dynamic movements such as running and jumping trials followed by current clinical evaluations would be helpful in preventing Achilles tendon re-rupture or secondary injury.

Development of a Golf Putting Result Recording System Using USB Camera (USB 카메라를 이용한 골프 퍼팅 결과 기록 장치의 개발)

  • Kim, Hyung-Sik;Choi, Jin-Seung;Tack, Gye-Rae;Lim, Young-Tae;Yi, Jeong-Han
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.239-243
    • /
    • 2010
  • The putting stroke accounts for 40~50% of total stroke for a golf rounding and most golfers have difficulties on the puting. Studies for the putting stroke have been conducted by analyzing various factors such as kinematics, kinetics, psychologic and physiologic parameters. A lot of devices were developed to support the studies. However there was no appropriate method to measure the position of the ball quantitatively. In this study, we developed a new measurement system to measure and evaluate the putting result. The developed system uses a USB camera to take the 2-dimensional image of the surface including the hole cup at the center of the image and the ball. The position of the ball is extracted as a set of distance and angle in polar coordinate system. We evaluated the new system with an indoor set-up for putting experiments and the system provided accurate measurement results. The proposed system can be combined with the other measurement systems such as 3D motion capture system and force plate without any restriction.