• Title/Summary/Keyword: 3D-SCM

Search Result 66, Processing Time 0.026 seconds

An Error Analysis of the 3D Automatic Face Recognition Apparatus (3D-AFRA) Hardware (3차원 안면자동분석 사상체질진단기의 Hardware 오차분석)

  • Kwak, Chang-Kyu;Seok, Jae-Hwa;Song, Jung-Hoon;Kim, Hyun-Jin;Hwang, Min-Woo;Yoo, Jung-Hee;Kho, Byung-Hee;Kim, Jong-Won;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.22-29
    • /
    • 2007
  • 1. Objectives Sasang Contitutional Medicine, a part of the traditional Korean medical lore, treats illness through a constitutional typing system that categorizespeople into four constitutional types. A few of the important criteria for differentiating the constitutional types are external appearances, inner state of mind, and pathological patterns. We had been developing a 3D Automatic Face Recognition Apparatus (3D-AFRA) in order to evaluate the external appearances with more objectivity. This apparatus provides a 3D image and numerical data on facial configuration, and this study aims to evaluate the mechanical accuracy of the 3D-AFRA hardware. 2. Methods Several objects of different shapes (cube, cylinder, cone, pyramid) were each scanned 10 times using the 3D Automatic Face Recognition Apparatus (3D-AFRA). The results were then compared and analyzed with data retrieved through a laser scanner known for its high accuracy. The error rates were analyzed for each grid point of facial contour scanned with Rapidform2006 (Rapidform2006 is a 3D scanning software that collects grid point data for contours of various products and products and product parts through 3D scanners and other 3D measuring devices; the grid point data thusly acquired is then used to reconstruct highly precise polygon and curvature models). 3. Results and Conclusions The average error rate was 0.22mm for the cube, 0.22mm for the cylinder, 0.125mm for the cone, and 0.172mm for the pyramid. The visual data comparing error rates for measurement figures retrieved with Rapidform2006 is shown in $Fig.3{\sim}Fig.6$. Blue tendency indicates smaller error rates, while red indicates greater error rates The protruding corners of the cube display red, indicating greater error rates. The cylinder shows greater error rates on the edges. The pyramid displays greater error rates on the base surface and around the vertex. The cone also shows greater error around the protruding edge.

  • PDF

Point Recognition Precision Test of 3D Automatic Face Recognition Apparatus(3D-AFRA) (3차원 안면자동인식기(3D-AFRA)의 안면 표준점 인식 정확도 검증)

  • Seok, Jae-Hwa;Cho, Kyung-Rae;Cho, Yong-Beum;Yoo, Jung-Hee;Kwak, Chang-Kyu;Hwang, Min-U;Kho, Byung-Hee;Kim, Jong-Won;Kim, Kyu-Kon;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.50-59
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Contitutions. Now We are developing 3D Automatic Face Recognition Apparatus to analyse the facial characteristics. This apparatus show us 3D image of man's face and measure facial figure. We should examine accuracy of position recognition in 3D Automatic Face Recognition Apparatus(3D-AFRA). 2. Methods We took a photograph of Face status with Land Mark by using 3D-AFRA. And We scanned Face status by using laser scanner(vivid 700). We analysed error average of distance between Facial Definition Points. We compare the average between using 3D-AFRA and using laser scanner. So We examined the accuracy of position recognition in 3D-AFRA at indirectly. 3. Results and Conclusions The error average of distance between Right Pupil and The Other Facial Definition Points is 0.5140mm and the error average of distance between Left Pupil and The Other Facial Definition Points is 0.5949mm in frontal image of face. The error average of distance between Left Pupil and The Other Facial Definition Points is 0.5308mm and the error average of distance between Left Tragion and The Other Facial Definition Points is 0.6529mm in laterall image of face. In conclusion, We assessed that accuracy of position recognition in 3D-AFRA is considerably good.

  • PDF

Design and Implementation of A Distributed Information Integration System based on Metadata Registry (메타데이터 레지스트리 기반의 분산 정보 통합 시스템 설계 및 구현)

  • Kim, Jong-Hwan;Park, Hea-Sook;Moon, Chang-Joo;Baik, Doo-Kwon
    • The KIPS Transactions:PartD
    • /
    • v.10D no.2
    • /
    • pp.233-246
    • /
    • 2003
  • The mediator-based system integrates heterogeneous information systems with the flexible manner. But it does not give much attention on the query optimization issues, especially for the query reusing. The other thing is that it does not use standardized metadata for schema matching. To improve this two issues, we propose mediator-based Distributed Information Integration System (DIIS) which uses query caching regarding performance and uses ISO/IEC 11179 metadata registry in terms of standardization. The DIIS is designed to provide decision-making support, which logically integrates the distributed heterogeneous business information systems based on the Web environment. We designed the system in the aspect of three-layer expression formula architecture using the layered pattern to improve the system reusability and to facilitate the system maintenance. The functionality and flow of core components of three-layer architecture are expressed in terms of process line diagrams and assembly line diagrams of Eriksson Penker Extension Model (EPEM), a methodology of an extension of UML. For the implementation, Supply Chain Management (SCM) domain is used. And we used the Web-based environment for user interface. The DIIS supports functions of query caching and query reusability through Query Function Manager (QFM) and Query Function Repository (QFR) such that it enhances the query processing speed and query reusability by caching the frequently used queries and optimizing the query cost. The DIIS solves the diverse heterogeneity problems by mapping MetaData Registry (MDR) based on ISO/IEC 11179 and Schema Repository (SCR).

Synthesis and Characterization of Tetrathiafulvalene Charge Transfer Compounds with Iron and Antimony Halides

  • Kim Young In;Choi Sung Nak;Jung Woo Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.465-468
    • /
    • 1994
  • The charge transfer compounds $(TTF)_4FeCl_3{\cdot}CH_3OH,\;(TTF)_4SbCl_4\;and\;(TTF)_5(SbBr_4)_2{\cdot}CH_3COCH_3$ were prepared from reactions of the TTF (tetrathiafulvalene) and metal halides. The compounds were characterized by spectroscopic (UV,IR, EPR and XPS) methods, magnetic susceptibility and electrical conductivity measurements. The d.c electrical conductivities of the pressed pellets are in the order of $10^{-1}-10^{-3} Scm^{-1}$, which lies in the range of semiconductor region at room temperature. It means that the partially ionized TTF has stacked in low-dimensional chain in each compound. Spectroscopic properties also indicate that TTF molecules are partially ionized and charge transfer has occurred from (TTF)n to Fe(III) center in $(TTF)_4FeCl_3{\cdot}CH_3OH$ whereas to the $-SbX_4^-$ entity in $(TTF)_4SbCl_4\;and\;(TTF)_5(SbBr_4)_2{\cdot}CH_3COCH_3$. The EPR g values are consistent with TTF radical formation and EPR linewidths suggest the delocalization of unpaired electrons along TTF stacks. A signal arised from metal (Fe and Sb) ions were not detected in EPR spectra, indicating that metal ion is in the diamagnetic state in each compound. The diamagnetic state was also examined by the magnetic susceptibility measurement. The magnetic properties reveal the significant interaction between the $TTF^+$ radical cations in the stacks. The oxidation state of metal ions was also investigated by XPS spectra.

A Supply Chain Management based on Mobile Agents with Flexible Reply Scheme (유연한 응답 기능을 가지는 이동 에이전트에 기반을 둔 공급 체인 관리)

  • Jeong, Won-Ho;Nam, Hui-Jeong
    • The KIPS Transactions:PartD
    • /
    • v.8D no.4
    • /
    • pp.439-450
    • /
    • 2001
  • Mobile agent is one of the promising ways of overcoming network load and latency. It is also a new software paradigm including those concepts of client/server, applet/servelet, and code-on-demand. In this paper, a new mobile agent concept with flexible replay scheme is proposed, which can deal with embarrassing situation when replying results should be accomplished in various distributed applications. For example, they are 1) a burden of bulky result, 2) a need of different replay scheme dependent on work type, 3) connection failure to the target node, and 4) a need of fast migration to next node to keep the itinerary. Regarding the source node, there may be another situation that it wants to be aware of whether its wi가 is completed or not. Three kinds of reply schemes are proposed for dealing flexibly with such situations. They are based on priority reply list where nodes to be replied are stored according to their priorities. An experimental supply chain management model using the proposed reply schemes is designed and implemented. It is one of good distributed applications appropriate for our reply schemes, because it requires different reply schemes according to work types and it is important to gather required information in time.

  • PDF

A Case Study of Supply Chain Management System of LG Siltron, Korea (실리콘 웨이퍼 공급사슬관리 시스템 구축에 관한 연구: (주) LG 실트론 사례를 중심으로)

  • Lee, Ho-Chang
    • IE interfaces
    • /
    • v.18 no.3
    • /
    • pp.234-246
    • /
    • 2005
  • A silicon wafer is a highly customized product made to the individual order varying its electrical and physical characteristics. Therefore, it has distinctive supply chain structure that is different from highly standardized commodity product. For high-volume/high-standardization product, it is general that a main stream of information flow initiated by the production planning of the manufacturers is usually directed to push both ways in a supply chain: upstream to the suppliers and downstream to the customers. Contrastingly, for low-volume/high-customization product, the information flow triggered by the fluctuating customer demand usually propagates upward to the suppliers through the manufacturers. Furthermore, for R &D based hi-technology product like silicon wafer, the interactive information feedback mechanism between manufacturer and customer, which is essential to the new product development process, is to be embedded in the supply chain. This article is a case study of supply chain management system of LG Siltron, a major Korean silicon wafer manufacturer. The SCM system entails special information structure fitting well typical high-variety/high-customization product, and also gives application possibilities to the R&D based high-technology product made to the individual customer order.

An Error Examination of 3D Face Automatic Recognition (3차원 안면자동인식기의 형상복원 오차검사)

  • Suk, Jae-Hwa;Cho, Kyung-Rae;Cho, Yong-Beum;Yoo, Jung-Hee;Kwak, Chang-Kyu;Lee, Soo-Kyung;Kho, Byung-Hee;Kim, Jong-Won;Kim, Kyu-Kon;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.2
    • /
    • pp.41-49
    • /
    • 2006
  • 1. Objectives The Face is an important standard for the classification of Sasang Contitutions. We are developing 3D Face Automatic Recognition Apparatus to analyse the facial characteristics. So We should examine a shape demobilization error of 3D Face Automatic Recognition Apparatus. 2. Methods We compared facial shape data be demobilized by 3D Face Automatic Recognition Apparatus with facial shape data that be demobilized by 3D laser scanner. The subject was two korean men. And We analysed the average error and the maximum error of two data. In this process, We used one datum point(the peak of nose) and two datum line(vertical section and horizontal section). 3. Results and Conclusions In each this comparison, the average error of vertical section was 1.962574mm and 2.703814mm. and the maximum error of vertical section was 16.968249mm and 18.61464mm. the average error of horizontal section was 4.173203mm and 21.487479mm. and the maximum error of horizontal section was 3.571210mm and 17.13255mm. Also We complemented this apparatus a little and We reexamined a shape demobilization error of 3D Face Automatic Recognition Apparatus again. Accuracy of a shape demobilization was improved a little. From now on We complement accuracy of a shape demobilization in 3D Face Recognition Apparatus.

  • PDF

A Study on the Characteristics of the Korean Adult Male Sound According to Sasang Constitution Using PSCC with a Sentence (사상체질음성분석기(四象體質音聲分析機)(PSSC)를 통한 한국인 성인남성(成人男性)의 체질별(體質別) 음향특성연구(音響特性硏究) - 단문(短文)을 중심으로 -)

  • Choi, Jae-Wan;Song, Hak-Soo;Han, Dong-Youn;Cho, Sung-Eon;Wang, Hyang-Lan;Jeon, Jong-Weon;Kim, Dal-Rae;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.3
    • /
    • pp.64-74
    • /
    • 2006
  • 1. Objectives and Methods A Study on the Characteristics of the Korean Adult Male Sound according to Sasang Constitution using PSSC with a Sentence. Sasang Constitutional Medicine(SCM) is the one of the traditional Korean Medicine. It classifies people into four categories like Taeyangin, Soyangin, Taeumin and Soeumin. The rule to classify is Appearance and Body Shape, Facial Appearance and Speech, Character and Talents and Diseases and Medications. This study was done to investigate the relationships between Voice and Sound parameters using PSSC(Phonetic System of Sasang Constitution) in a sentence. Experimental Participants were 195 Korean adult males including 1 Taeyangin, 37 Soyangin, 105 Taeumin and 52 Soeumin. Sasang Constitutional specialist used PSSC and Korean Medical Diagnosis to classify participants into four constitution. 2. Results In Pitch segment, Soyangin's Center freq.(4) was significantly high compared with Taeyangin and Taeumin groups. Soyangin's and Soeumin's Center freq.(6) was significantly high compared with Taeyangin and Taeumin groups. In APQ segment and Octave segment, there were no significant differences among four groups. In Shimmer segment, Taeumin's F Shimmer(1) and F Shimmer(2) were significantly high compared with Taeyangin and Soyangin groups. In Energy segment, Taeyangin's 2k-4k total sum, 2k-4k dev., C dev., C# dev. and D S.D. were significantly high compared with other groups. In Recording time segment, there was no significant difference among four groups. More Taeyangin cases and the other parameters are needed to determine constitution using PSSC and to make PSSC effective. 3. Conclusions From above result, there is the possibility of efficiency standard guide for constitution diagnosis by analyzation og voice.

  • PDF

A Study on the Sasang Constitutional Symptom of Taeumin by Voice Characteristics (음향특성에 따른 태음인 체질병증(體質病證) 연구(硏究))

  • Kim, Dal-Rae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.90-97
    • /
    • 2007
  • 1. Objectives and Methods This study was done to investigate the relationships of Sound parameters between Liver Heat Symptom and Esophagus Symptom of Taeumin using PSSC(Phonetic System of Sasang Constitution) in a sentence. Experimental Participants were 20 Korean adult males including, each 10 Liver Heat Symptom and Esophagus Symptom of Taeumin. 2. Results In Pitch segment, APQ segment and Shimmer segment, there were no significant differences between Liver Heat Symptom and Esophagus Symptom of Taeumin. In Octave segment, there were significant differences in Octave 1, Octave 3, Octave 4, Octave 6 of Liver Heat Symptom of Taeumin were significantly high compared with Esophagus Symptom of Taeumin. In Energy segment, FreQ Domain Total Sum / cnt(0), 0k-2k Total Sum,0k-2k sum dev., 2k-4k Total Sum, 2k-4k sum dev., A# Tot E, B__TOT_E, C__TOT_E, C# Tot E, D__TOT_E, A sum dev., A# sum dev., B sum dev., C sum dev., C# sum dev., Dsum dev., D# sum dev., E sum dev., F sum dev., F# sum dev., G sum dev., G# sum dev. of Liver Heat Symptom of Taeumin were significantly high compared with Esophagus Symptom of Taeumin. In Voice Recording time segment, Total Voice Recording Time, Voice Recording Time, Divide By Time3, Divide By Energy10, Total Unit, Max Unit Position, U_0 TO 3 of Liver Heat Symptom of Taeumin were significantly high compared with Esophagus Symptom of Taeumin. 3. Conclusion From above result, there is the postbility of efficiency quide constitutional sx. of Taeumin by Voice characteristics. More Soeumin, Soyangin and Taeyangin Symptoms are needed to determine Sasang Constitution using PSSC and to make PSSC effective.

  • PDF

System Development for Tracking a UHF Passive RF1D Tag in an Outpatient Clinic (외래병원 환경에서 UHF 수동형 RFID 기술을 활용한 태그 추적 시스템 개발)

  • Min, Dai-Ki
    • The Journal of Society for e-Business Studies
    • /
    • v.16 no.3
    • /
    • pp.113-127
    • /
    • 2011
  • An RFID system has been widely applied in many areas over the initial SCM application. In the literature enormous RFID applications in healthcare are documented to improve patient safety, patient/provider logistics, and the efficiency of collecting data. Based on the proposed 4-layered RFID system architecture, we introduce a case that implemented an UHF passive RFID-based tracking system in an outpatient clinic. Particularly, we propose a method to process RFID data that contains noise and missing reads. The proposed method for processing unreliable RFID data is capable to locate the tag accurately and provide additional business information. We finally conclude the paper with identifying obstacles and what is necessary to ensure system reliability.