• Title/Summary/Keyword: 3D-Conformal Radiotherapy

Search Result 94, Processing Time 0.021 seconds

A Study for Advanced Radiation Therapy (발전된 방사선 치료에 관한 고찰)

  • Jang, Eun-Sung;Beak, Seong-Min;Ko, Seung-Jin;Kang, Se-Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.115-122
    • /
    • 2008
  • Purpose: The cancer treatment which uses radiation from next year when the X-ray is discovered with the fact that it is started. The radiation treatment technique for a cancer treatment is developed ceaselessly without and it is come and, with advancement of the computer and electromagnetic engineering it joins in and quickly, it was made to do a many development from radiation treatment field. Accordingly, this study is examine in the radiotherapy technique which is developed that importance to therapeutic principles and methods. Materials and Methods: We had investigated record for radiotherapy technique which is developed and we had acquired information widely at clinical experience data. Results: The cancer treatment which uses the radiation of today is repeating a dazzling development. Past the treatment which is two-dimensional it does not correspond in therapeutic objective but currently 3 dimension three-dimensional moulding treatment or centurial control radiation treatment this the fourth dimension therapeutic technique which is in parallel to be introduced the complication solution in compliance with a normal organization protection and the radiation which are a difficult problem of during that time radiation treatment possibly did. Conclusion: 3-dimensional and 4-dimensional modern radiation treatment which is developen is that corresponding in objective of radiation treatment and the evaluation that again it does thick, judges in about the cancer treatment which uses radiation with the fact that the protection of normal organization is almost become accomplished.

  • PDF

Reduction of Patient Dose in Radiation Therapy for the Brain Tumors by Using 2-Dimensional Vertex or Oblique Vertex Beam Technique

  • Kim, Il-Han;Chie, Eui-Kyu;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.225-231
    • /
    • 2003
  • Up-front irradiation technique as 3-dimensional conformation, or intensity modulation has kept large proportion of brain tumors from being complicated with acute radiation reactions in the normal tissue during or shortly after radiotherapy. For years, we've cannot help but counting on 2-D vertex beam technique to reduce acute reactions in the brain tumor patients because we're not equipped with 3-dimensional planning system. We analyzed its advantages and limitations in the clinical application. From 1998 to 2001, vertex or oblique vertex beams were applied to 35 patients with primary brain tumor and 25 among them were eligible for this analysis. Vertex(V) plans were optimized on the reconstructed coronal planes. As the control, we took the bilateral opposed techniques(BL) otherwise being applied. We compared the volumes included in 105% to 50% isodose lines of each plan. We also measured the radiation dose at various extracranial sites with TLD. With vertex techniques, we reduced the irradiated volumes of contralateral hemisphere and prevented middle ear effusion at contralateral side. But the low dose volume increased outside 100%; the ratio of V to BL in irradiated volume included in 100%, 80%, 50% was 0.55+/-0.10, 0.61+/-0.10, and 1.22+/-0.21, respectively. The hot area within 100% isodose line almost disappeared with vertex plan; the ratio of V to BL in irradiated volume included in 103%, 105%, 108% was 0.14+/-0.14, 0.05./-0.17, 0.00, respectively. The dose distribution within 100% isodose line became more homogeneous; the ratio of volume included in 103% and 105% to 100% was 0.62+/-0.14 and 0.26+/-0.16 in BL whereas was 0.16+/-0.16 and 0.02+/-0.04 in V. With the vertex techniques, extracranial dose increased up to $1{\sim}3%$ of maximum dose in the head and neck region except submandibular area where dose ranged 1 to 21%. From this data, vertex beam technique was quite effective in reduction of unnecessary irradiation to the contralateral hemispheres, integral dose, obtaining dose homogeneity in the clinical target. But it was associated with volume increment of low dose area in the brain and irradiation toward the head and neck region otherwise being not irradiated at all. Thus, this 2-D vertex technique can be a useful quasi-conformal method before getting 3-D apparatus.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

Head and neck extra nodal NHL (HNENL) - Treatment Outcome and Pattern of failure - A Single Institution Experience

  • Giridhar, Prashanth;Mallick, Supriya;Bhasker, Suman;Pathy, Sushmita;Mohanti, Bidhu Kalyan;Biswas, Ahitagni;Sharma, Atul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6267-6272
    • /
    • 2015
  • Background: Extra nodal lymphoma (ENL) constitutes about 33 % of all non-Hodgkin's lymphoma. 18-28% develops in the head and neck region. A multimodality treatment with multi-agent chemotherapy (CT) and radiotherapy (RT) is considered optimum. Materials and Methods: We retrieved the treatment charts of patients of HNENL treated in our institute from 2001-2012. The charts were reviewed and the demographic, treatment details and outcome of HNENL patients were retrieved using predesigned pro-forma. Results: We retrieved data of 75consecutive patients HNENL. Median age was 47years (Range: 8-76 years). Of the 75 patients 51 were male and 24 were female. 55patients were evaluable. The patient and tumor characteristics are summarized in Table 1. All patients were staged comprehensively with contrast enhanced computed tomography of head, neck, thorax, abdomen, pelvis and bone marrow aspiration and biopsy 66 patients received a combination multi-agent CT with CHOP being the commonest regimen. 42 patients received 4 or lesser number of cycles of chemotherapy whereas 24received more than 4 cycles chemotherapy. Post radiotherapy, 41 out of 42 patients had a complete response at 3 months. Only 21patients had a complete response after chemotherapy. All patients received radiation (mostly involved field radiation) as a part of the treatment. The median radiation dose was 45 Gray (Range: 36 Gray-50 Gray). The radiation was planned by 2D fluoro simulation based technique in 37cases and by 3 Dimensional conformal radiation therapy (3DCRT) in 36 cases. Two patients were planned by the intensity modulated radiation therapy (IMRT) technique. IMRT was planned for one thyroid and one nasal cavity primary. 5 patients experienced relapse after a median follow up of 19 months. The median survival was not reached. The estimated two and three year survival were 92.9% (95%CI- 68.6- 95.35) and 88% (95%CI- 60.82 - 92.66) respectively. Univariate analysis revealed higher stage and poorer baseline performance status to be significantly associated with worse progression free survival. 5 patients progressed (relapse or primary disease progression) after treatment. Of the 5 patients, two patients were primary orbital NHL, two patients had NHL nasal cavity and one was NHL thyroid. Conclusions: Combined modality treatment in HNENL confers excellent disease control with acceptable side effects.

Radiation Therapy of Nasopharyngeal Carcinoma (비인두강 종양의 방사선치료성적)

  • Nho Young Ju;Cho Jeong Gill;Ahn Seung Do;Choi Eun Kyung;Kim Jong Hoon;Kang One Chul;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.305-313
    • /
    • 1997
  • Purpose : This is a retrospective study to evaluate the results of radiation therapy and prognostic factors influencing the results in nasopharyngeal carcinoma. Materials and Methods: From October 1989 to May 1996. 56 Patients were treated for nasopharyngeal carcinoma at Department of Radiation On-cology. According to stage, patients were distributed as follows : stage I (2), II (13). II (11), IV (30). Twenty-eight patients were treated with radiation therapy only, 7 patients were treated with neoadiuvant chemotherapy followed by radiation therapy. Twenty-one Patients were treated with radiation therapy and weekly CDDP. After external beam radiotherapy of 60Gy, 46Patients received boost dose with intracavitary radiation and 9 Patients with 3D conformal therapy. One patient received boost dose with 2 dimensional Photon beam therapy. The tumor dose ranged from 69.4Gy to 86.2Gy with median dose of 74.4Gy. The follow-up Period ranged from 5 months to 92 months with a median of 34 months. Results : Forty-seven patients achieved complete response and 8 Patients showed partial response. One Patient showed minimal response. Patterns of failure were as follows : locoregional recurrence (8) and distant metastasis (18). Among these patients, 2 patients failed locoregionally and distantly. The sites of distant metastasis were bone (8), lung (8) and liver (4). Five years survival rate was $67.2\%$ and 5 years disease-free survival rate was $53.6\%$. KPS (P=0.005) and response ol radiation therapy (P=0.0001) were significant prognostic factors for overall survival. KPS (P= 0.02) and response of radiation therapy (P=0.005) were significant Prognostic factors for disease-free survival. Conclusion : This retrospective study showed that distant metastasis was the Predominant pattern of relapse in nasopharyngeal cancer Neoadiuvant chemotherapy or weekly CDOP did not influence the distant metastasis-free survival. For advanced T stage, 3D conformal therapy Provided an improved dose coverage compared to ICR But further follow-up was needed in Patients with 3D conformal therapy to assess the efficacy of this therapy. Development of techniques of radiation therapy to improve locoregional control and of more effective systemic chemotherapy regimen are needed.

  • PDF

A Study of Cancer Incidence Rate due to Photoneutron Dose during Radiation Therapy for Prostate Cancer Patients (전립샘암 환자의 방사선 치료 시 광중성자 선량으로 인한 암 발생률의 연구)

  • Lee, Joo-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.471-476
    • /
    • 2022
  • The purpose of this study was to study the probability of cancer occurrence due to photoneutron dose exposure of the colon and thyroid gland, which are normal organs, in 3D CRT, IMRT 5 portals, and IMRT 9 portals, which are radiotherapy methods for prostate cancer. The total prescribed dose for prostate cancer was 6600 cGy, 220 cGy per dose, and 30 divided irradiations were applied for the total number of times. After setting up the Rando phantom on the treatment table (couch) of the medical linear accelerator used in the experiment, an optically stimulated luminescence albedo neutron dosimeter was placed on the corresponding area of the large intestine and thyroid gland of the phantom for measurement. During 3D CRT of prostate cancer, the probability of secondary cancer due to photoneutron dose to the colon and thyroid gland, which are normal organs, was 1.8 per 10,000 people. And IMRT 5 portals were 8.7 per 10,000 people, which was about 5 times larger than 3D CRT. IMRT 9 portals derived the result that there is a probability that 1.2 people per 1,000 people will develop cancer. Based on this study, the risk of secondary radiation exposure due to the dose of photoneutrons generated during radiation therapy is studied, and it is thought that it will be used as useful data for radiation protection in relation to the stochastic effect of radiation in the future.

Results of Three-Dimensional Conformal Radiation Therapy for the Treatment of a Solitary Sternal Relapse of Breast Cancer (흉골에 단독 전이된 유방암의 삼차원 입체조형 방사선 치료 성적)

  • Kim, Hae-Young;Huh, Seung-Jae;Park, Won;Choi, Do-Ho;Kang, Min-Kyu;Yang, Jung-Hyun;Nam, Seok-Jin;Im, Young-Hyuck
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.91-95
    • /
    • 2008
  • Purpose: To evaluate the response and survival rate after three-dimensional conformal radiation therapy(3D-CRT) of patients with a solitary sternal relapse of breast cancer. Materials and Methods: Seventeen patients between May 1996 and June 2005 were evaluated with the salvage 3D-CRT treatment of a solitary sternal relapse of breast cancer. The treatment fields included the gross tumor volume with 2 cm margins. The total radiation dose was $35.0{\sim}61.5$ Gy(biologic effective dose of $43.7{\sim}76.9Gy_{10}$ using an $\alpha/\beta$ ratio of 10 Gy), with a daily dose of $1.8{\sim}3.0$ Gy. The tumor response was evaluated by the change in maximum tumor size via follow up CT scans $1{\sim}3$ months after the completion of treatment. Results: An objective tumor response was achieved in all patients, with a complete response in 5 patients and a partial response in 12 patients. The 5-year overall survival rate was 51.9%(median survival time: 27 months), and the most important factor affecting overall survival was the disease-free interval(interval from primary surgery of breast cancer to the development of sternal metastasis): The 5-year overall survival rate was 61.8% for patients with a disease-free interval ${\geq}12$ months and 0.0% for patients with disease-free interval <12 months(p=0.03). Conclusion: The response to 3D-CRT was good in patients with solitary sternal relapse of breast cancer. Particularly, patients with long disease-free interval from primary surgery survived significantly longer than patients with short disease-free interval from primary surgery.

Treatment and Prognosis for an Esthesioneuroblastoma over a 20-Year Period: Impact of Treatment Era (감각신경모세포종의 20년에 걸친 치료와 예후 분석: 치료 시기에 따른 차이)

  • Song, Chang-Hoon;Kim, Il-Han;Wu, Hong-Gyun;Kim, Dong-Wan;Rhee, Chae-Seo
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.189-193
    • /
    • 2009
  • Purpose: To report on the changes in the patterns of care and survival over time for esthesioneuroblastoma. Materials and Methods: We retrospectively analyzed 42 previously untreated and histologically confirmed esthesioneuroblastoma patients seen between March 1989 and June 2007. According to Kadish's classification, 3 patients (7%) were stage A, 6 (14%) at stage B, and 33 (79%) at stage C. Of the 33 Kadish C patients, 19 and 14 patients were treated from 1989 through 2000 and from 2001 through 2007, respectively. Treatment included surgical resection, radiotherapy, chemotherapy, or a combination of these methods. Chemotherapy was administered to 8 of 19 patients (42%) seen from 1989 through 2000, whereas all of the 14 patients seen from 2001 through 2007 received chemotherapy (p<0.001). No patient was treated by three-dimensional conformal radiotherapy (3D-CRT) from 1989 through 2000, however 8 of 14 patients (67%) seen from 2001 through 2007 underwent 3D-CRT (p<0.001). The median follow-up time for surviving patients was 6.5 years (range, 2.2~15.8 years). Results: The 5-year overall survival (OS) and progression-free survival (PFS) rates for the entire cohort were 53% and 39%, respectively. The 5-year OS was 100% for Kadish stages A or B and 39% for stage C (p=0.007). For patients with stage C disease who were treated from 1989 to 2000 and from 2001 to 2007, the 5-year OS rate was 26% and 59% (p=0.029), respectively and the corresponding 5-year PFS rate was 16% and 46% (p=0.001), respectively. Intraorbital extension and treatment era (1989~2000 vs. 2001~2007) were found as independent factors for OS and PFS in a multivariate analyses. Conclusion: The results of this study suggest that treatment era, which features a distinction in treatment modality and technique with the introduction of 3D-CRT, may be the cause of improved OS and PFS in Kadish stage C patients. To achieve better outcomes for patients with Kadish stage C, combined chemoradiotherapy, especially 3D-CRT, is recommended in addition to surgery.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.