• Title/Summary/Keyword: 3D-CFD

Search Result 678, Processing Time 0.028 seconds

A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings (중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구)

  • Min, Se Hong;Lee, Jae Moon;Bae, Yeon Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

Long-Distance Plume Detection Simulation for a New MWIR Camera (장거리 화염 탐지용 적외선 카메라 성능 광선추적 수치모사)

  • Yoon, Jeeyeon;Ryu, Dongok;Kim, Sangmin;Seong, Sehyun;Yoon, Woongsup;Kim, Jieun;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.245-253
    • /
    • 2014
  • We report a realistic field-performance simulation for a new MWIR camera. It is designed for early detection of missile plumes over a distance range of a few hundred kilometers. Both imaging and radiometric performance of the camera are studied by using real-scale integrated ray tracing, including targets, atmosphere, and background scene models. The simulation results demonstrate that the camera would satisfy the imaging and radiometric performance requirements for field operation.

Integrated fire dynamics and thermomechanical modeling framework for steel-concrete composite structures

  • Choi, Joonho;Kim, Heesun;Haj-ali, Rami
    • Steel and Composite Structures
    • /
    • v.10 no.2
    • /
    • pp.129-149
    • /
    • 2010
  • The objective of this study is to formulate a general 3D material-structural analysis framework for the thermomechanical behavior of steel-concrete structures in a fire environment. The proposed analysis framework consists of three sequential modeling parts: fire dynamics simulation, heat transfer analysis, and a thermomechanical stress analysis of the structure. The first modeling part consists of applying the NIST (National Institute of Standards and Technology) Fire Dynamics Simulator (FDS) where coupled CFD (Computational Fluid Dynamics) with thermodynamics are combined to realistically model the fire progression within the steel-concrete structure. The goal is to generate the spatial-temporal (ST) solution variables (temperature, heat flux) on the surfaces of the structure. The FDS-ST solutions are generated in a discrete form. Continuous FDS-ST approximations are then developed to represent the temperature or heat-flux at any given time or point within the structure. An extensive numerical study is carried out to examine the best ST approximation functions that strike a balance between accuracy and simplicity. The second modeling part consists of a finite-element (FE) transient heat analysis of the structure using the continuous FDS-ST surface variables as prescribed thermal boundary conditions. The third modeling part is a thermomechanical FE structural analysis using both nonlinear material and geometry. The temperature history from the second modeling part is used at all nodal points. The ABAQUS (2003) FE code is used with external user subroutines for the second and third simulation parts in order to describe the specific heat temperature nonlinear dependency that drastically affects the transient thermal solution especially for concrete materials. User subroutines are also developed to apply the continuous FDS-ST surface nodal boundary conditions in the transient heat FE analysis. The proposed modeling framework is applied to predict the temperature and deflection of the well-documented third Cardington fire test.

A Fluid Analysis Study on Centrifugal Pump Performance Improvement by Impeller Modification (원심펌프 회전차 Modification시 성능개선에 관한 유동해석 연구)

  • Lee, A-Yeong;Jang, Hyun-Jun;Lee, Jin-Woo;Cho, Won-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • Centrifugal pump is a facility that transfers energy to fluid through centrifugal force, which is usually generated by rotating the impeller at high speed, and is a major process facility used in many LNG production bases such as vaporization seawater pump, industrial water and fire extinguishing pump using seawater. to be. Currently, pumps in LNG plant sites are subject to operating conditions that vary depending on the amount of supply desired by the customer for a long period of time. Pumps in particular occupy a large part of the consumption strategy at the plant site, and if the optimum operation condition is not available, it can incur enormous energy loss in long term plant operation. In order to solve this problem, it is necessary to identify the performance deterioration factor through the flow analysis and the result analysis according to the fluctuations of the pump's operating conditions and to determine the optimal operation efficiency. In order to evaluate operation efficiency through experimental techniques, considerable time and cost are incurred, such as on-site operating conditions and manufacturing of experimental equipment. If the performance of the pump is not suitable for the site, and the performance of the pump needs to be reduced, a method of changing the rotation speed or using a special liquid containing high viscosity or solids is used. Especially, in order to prevent disruptions in the operation of LNG production bases, a technology is required to satisfy the required performance conditions by processing the existing impeller of the pump within a short time. Therefore, in this study, the rotation difference of the pump was applied to the ANSYS CFX program by applying the modified 3D modeling shape. In addition, the results obtained from the flow analysis and the curve fitting toolbox of the MATLAB program were analyzed numerically to verify the outer diameter correction theory.

Temperature Prediction of Cylinder Components in Medium-Speed Diesel Engine Using Conjugate Heat Transfer Analysis (복합 열전달 해석을 이용한 중속 디젤엔진 실린더 부품 온도 분포 예측)

  • Choi, Seong Wook;Yoon, Wook Hyoen;Park, Jong Il;Kang, Jeong Min;Park, Hyun Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.781-788
    • /
    • 2013
  • Predicting the engine component temperature is a basic step to conduct structural safety evaluation in medium-speed diesel engine design. Recent trends such as increasing power density and performance necessitate more effective thermal management of the engine for achieving the desired durability and reliability. In addition, the local temperatures of several engine components must be maintained in the proper range to avoid problems such as low- or high-temperature corrosion. Therefore, it is very important to predict the temperature distribution of each engine part accurately in the design stage. In this study, the temperature of an engine component is calculated by using steady-state conjugate heat transfer analysis. A proper approach to determine the thermal load distribution on the thermal boundary area is suggested by using 1D engine system analysis, 3D transient CFD results, and previous experimental data from another developed engine model. A Hyundai HiMSEN engine having 250-mm bore size was chosen to validate the analysis procedure. The predicted results showed a reasonable agreement with experimental results.

A study on the improvement of the air exhaust system at the PSD installed subway station (도시철도 지하역사 PSD 설치에 따른 배기시스템 개선 연구)

  • Kwon, Soon-Bark;Song, Ji-Han;Ryu, Ju-Hwan;Jo, Seung-Won;Oh, Tae-Suk;Bae, Sung-Joon;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.353-362
    • /
    • 2015
  • Platform screen door (PSD) installed at underground subway station has reduced the safety accident, but it may cause poor air ventilation condition due to the isolated exhaust duct in the subway tunnel area. In this study, the additional ventilation system was suggested, which can be installed at a void space (i.e., storage room under stairs) of platform in order to improve efficiency of air ventilation rate. Exhausted air from platform was directed to underneath of platform and joined with existing ventilation duct of train exhaust system (TES). One subway station in Seoul city was selected to predict the effectiveness of the suggested lower exhaust system by using the computational fluid dynamics (CFD) analysis. The predicted mean age of air was decreased by 16.5% which proves the improvement of air ventilation efficiency when the suggested lower exhaust system was applied.

Performance Analysis of a Portable Horizontal Axis Hydro Turbine by Computational Fluid Dynamics (CFD를 통한 휴대용 수평축 수차의 성능해석)

  • Park, Ji-Hoon;Baek, Sang-Hwa;Choi, Hyen-Jun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.561-568
    • /
    • 2020
  • A performance analysis was conducted according to changes in inflow velocity and the tip speed ratio of a portable horizontal-axis hydro turbine that can be used for marine leisure sports and outdoor activities by using the commercial computational fluid dynamics software ANSYS CFX. By using the analysis result and flow field analysis, the design was reviewed and the performance of the device was confirmed. In addition, data necessary to improve the performance of the hydro turbine were acquired by performing an additional performance analysis according to the variable blade pitch angle. The results among the numerical analysis cases show that the highest performance at all inflow velocities and blade pitch angles if achieved at a tip speed ratio of 4. The output power was found to be 30 W even under some conditions below the design flow rate. Among the numerical analysis cases, the highest output power (~ 85 W) and power coefficient (~ 0.30) were observed at an inlet flow rate of 1.5 m/s, a blade pitch angle of 3°, and a tip speed ratio of 4.

Optimal Gas Detection System in Cargo Compressor Room of Gas Fueled LNG Carrier (가스추진 LNG 운반선의 가스 압축기실에 설치된 가스검출장치의 최적 배치에 관한 연구)

  • Lee, Sang-Won;Shao, Yude;Lee, Seung-Hun;Lee, Jin-Uk;Jeong, Eun-Seok;Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.617-626
    • /
    • 2019
  • This study analyzes the optimal location of gas detectors through the gas dispersion in a cargo compressor room of a 174K LNG carrier equipped with high-pressure cargo handling equipment; in addition, we propose a reasonable method for determining the safety regulations specified in the new International Code of the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk (IGC). To conduct an LNG gas dispersion simulation in the cargo compressor room-equipped with an ME-GI engine-of a 174 K LNG carrier, the geometry of the room as well as the equipment and piping, are designed using the same 3D size at a 1-to-1 scale. Scenarios for a gas leak were examined under high pressure of 305 bar and low pressure of 1 bar. The pinhole sizes for high pressure are 4.5, 5.0, and 5.6mm, and for low pressure are 100 and 140 mm. The results demonstrate that the cargo compressor room will not pose a serious risk with respect to the flammable gas concentration as verified by a ventilation assessment for a 5.6 mm pinhole for a high-pressure leak under gas rupture conditions, and a low-pressure leak of 100 and 140 mm with different pinhole sizes. However, it was confirmed that the actual location of the gas detection sensors in a cargo compressor room, according to the new IGC code, should be moved to other points, and an analysis of the virtual monitor points through a computational fluid dynamics (CFD) simulation.

Study on Applying of Unsteady Analysis in ToSS(Total Sewer Operation and Management System) for Optimal Management of Sewer System (하수관망 최적관리를 위한 통합하수관거 시스템의 부정류 해석적용에 대한 연구)

  • Choi, Gye-Woon;Lee, Ho-Sun;Jho, Hyung-Guen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1148-1153
    • /
    • 2005
  • 하수관거는 국민의 정맥이라고 할 수 있을 정도로 도시의 환경관리와 치수, 쾌적한 환경조성에 있어서 매우 중요한 시설이며 그 규모가 광범위하고 복잡한 네트워크로 구성되어 있다. 이러한 하수관망을 통해 이송되는 물은 지저분하고 냄새가 심하기 때문에 지하에 관의 형태로 대부분 시공되어 왔으며, 상수관망처럼 압력관이 아니라 대부분 중력에 의한 이송방식을 채택하고 있어 문제 발생 시 원인파악과 대처를 힘들게 하는 요인을 가지고 있다. 특히 하수관거의 관리 소홀은 곧바로 토양오염과 인근 환경오염으로 직결되며 장기적으로는 상수를 오염시키는 요인으로 작용하므로 체계적인 방법과 장기적인 안목을 가지고 명확한 분석을 시행할 수 있는 시스템을 가지고 최적으로 유지관리 되어야 한다. 최근 들어 이러한 하수도 시설을 효율적으로 관리 및 개선하기 위해 대도시를 중심으로 근거 조사와 정비 사업이 활발히 시행되고 있다. 그러나, 사업효과를 검증하거나 관로의 유지관리를 위하여 국내 실정에 맞지 않는 외국하수관망 흐름 해석 프로그램을 그대로 사용하고 있고 정확한 해석이 이루어지지 않고 있어 효율적인 유지관리가 어렵다. 이와 같은 문제점을 해결하기 위하여 하수관망해석이나 하수관망 정비시 필요한 불명수산정이 가능하고 국내실정에 맞는 프로그램 개발이 시급한 실정이며, 아울러 프로그램을 효율적 운영하고 관리하는 제어관리 기술을 개발, 진행하고 있다. 본 논문에서는 개발된 프로그램의 부정류 해석 기능을 활용하여 대상구역의 해석을 실시하여 기존분석방법의 I/I결과와 비교하였으며 최적관리를 위한 방안을 제시하였다.준편차가 증가하고 있음을 알 수 있다. 본 연구에서는 상용 CFD모형인 FLOW-3D를 계획 중인 하수처리장의 침전지 유입부 설계에 적용하였으며 저류벽의 위치와 폭, 유공정류벽의 유공율에 따른 유입하수의 분배효과를 분석하였다. 실험을 수행하여 보다 정밀한 공식으로 개선할 수 있었다.$10,924m^3/s$ 및 $10,075m^3/s$로서 실험 I의 $2,757m^3/s$에 비해 통수능이 많이 개선되었음을 알 수 있다.함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는

  • PDF

Flow and smoke behavior of a longitudinal ventilation tunnel with various velocities using computational fluid dynamics (팬의 운전조건에 따른 종류식환기터널 내의 연기거동에 관한 전산유체역학연구)

  • Lee, J.H.;Kwon, Y.J.;Kim, D.E.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.1
    • /
    • pp.105-115
    • /
    • 2014
  • A numerical analysis on the smoke behavior and evacuee safety has been performed with computational fluid dynamics. The purpose of this study is to build computational processes for an evacuation and prevention of a fire disaster of a 3 km-length tunnel in Korea. To save computational cost, 1.5 km of the tunnel that can include a few cross-passing tunnels is considered. We are going to assess the fire safety in a road tunnel according to the smoke level, which consists of the smoke density and the height from the floor. The smoke density is obtained in detail from three-dimensional unsteady CFD analysis. To obtain proper temperature distributions on the tunnel wall, one-dimensional conduction equation is considered instead of an adiabatic wall boundary or a constant heat flux. The tunnel considered in this study equips the cross passing tunnels for evacuees every 250 m. The distance is critical in both safety and economy. The more cross passing tunnels, the more safe but the more expensive. Three different jet fan operations can be considered in this study; under- and over-critical velocities for normal traffic condition and 0-velocoty operation for the traffic congestion. The SE (smoke environment) level maps show a smoke environment and an evacuating behavior every moment.