NUMERICAL ANALYSIS ON THE HEAT TRANSFER AND FLOW IN THE SHELL AND TUBE HEAT EXCHANGER (Shell & Tube 열교환기 Shell 측 열전달 및 유동에 대한 수치해석)

  • Lee, Sang-Hyuk;Lee, Myung-Sung;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.149-152
    • /
    • 2007
  • The numerical simulations on the heat transfer and flow field were carried out for the improvement of the performance of the shell and tube heat exchanger. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. The present geometry of the heat exchanger causes poor heat transfer since the air inside shell dose not flow through the tube bundle, but around it. The enhancement of the heat transfer can be achieved by the variation of the design factor like the sealing strip located on the top/bottom and middle of the baffle.

  • PDF

Numerical Investigation of the Effect of Turbine flow Passage Variation on the Turbine Performance (유로형상변화에 따른 터빈성능 변화의 수치적 해석)

  • Park, Pyun-Goo;Jeong, Eun-Hwan;Kim, Jin-Han
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.481-487
    • /
    • 2005
  • A turbopump turbine consists of rotational part including a rotor and stationary part including nozzles and exit guide vanes, of which shape and relative position affect turbine performance owing to supersonic flows with prevailing unsteadiness. In this study, numerical 3-D flow calculations of the turbine with the different number of exit guide vanes and different relative position of each component are conducted and the effect of flow passage variations on turbine performance is analyzed.

  • PDF

The Numerical Analysis about the Hunting Factors of the Orifice Meter (오리피스 유량계의 헌팅 원인과 영향인자에 관한 해석적 연구)

  • Shin, Chang-Hoon;Ahn, Seung-Hee;Chung, Jong-Tae;Her, Jae-Young;Kim, Woo-Sik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.150-157
    • /
    • 2005
  • Generally, the flow hunting is observed in almost all of the orifice meters but the intensity of the flow hunting is different at each metering system. So, we were getting some Questions as follows; why such a difference occurs and whether it influence to metering error rate or not. To investigate the flow hunting characteristics, we are trying to examine the flow characteristics around the orifice meter when the transient flow or pressure is generated at after the PCV(Pressure Control Valve) by 3D CFD method. And we have compared numerical results with experimental results at M - PCV station in order to clarify the relations with both the metering-pipeline diameter and flow rate. Finally, we can show some major factors influencing to the flow hunting and propose some correcting scheme of the flow hunting equation.

  • PDF

Analysis of Flow Characteristics in the Intake System of 6-Cylinder MPI CNG Engine

  • Ha, Seung-Hyun;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.215-222
    • /
    • 2002
  • It has been well acknowledged that intake system plays great role in the performance of reciprocating engine. Well-designed intake system is expected to not only increase engine efficiency but also decrease engine emission, which is one of the most urgent issues in the automotive society. Thorough understanding of the flow in intake system helps great to design adequate intake system. Even though both experimental and numerical methods are used to study intake flow, numerical analysis is more widely used due to its merits in time and economy. Intake system of In-line 6-Cylinder CNG engine was chosen for the analysis ICEM CFD HEXA was used to create 3-D structured grid and FIRE code was used for the flow analysis in the intake system. Due to the complexity of the geometry standard ${\kappa}-{\varepsilon}$ turbulence model was applied. Numerical analysis was performed for various inlet and outlet boundary conditions under both steady and transient flow. Inlet mass flow rate and outlet pressure variation were changing parameters with respect to engine speed. Flow parameters, such as velocity, pressure and flow distribution, were evaluated to provide adequate data of this intake system.

  • PDF

A study of effect of wall distance on flow around a cylinder (벽면 거리에 따른 원형 실린더 주변의 유동장 연구)

  • Ju, Dong-Guk;Jang, Gyeong-Sik
    • Proceeding of EDISON Challenge
    • /
    • 2014.03a
    • /
    • pp.649-653
    • /
    • 2014
  • 채널 내부에 장애물이 존재하는 유동 형태는 다양한 공학적 문제에서 나타나고 있으므로 여러 가지 형상 및 유동 조건에 따른 유동 특성 연구가 필요하다. 따라서 본 논문에서는 장애물의 형상을 일정한 크기의 원형 실린더로 설정하고 실린더는 위아래 채널 벽 중앙에 위치하도록 하여 2차원 채널 내에 원형 실린더가 존재하는 경우에 대하여 CFD연구를 수행하였다. 실린더와 위아래 채널 벽면과의 거리를 변화시켜 각각의 거리에 대해 유동 재부착 길이, 유동의 주기성, 항력계수 등의 유동 특성을 관찰하였다. 연구결과 각 간격[실린더벽면과 채널벽면간의 거리(G)/실린더지름(d)]이 0.5, 1, 2, 3, 5, 15에 따른 재 부착 지점(Reattachment Length)은 채널 벽면이 실린더로부터 멀어질수록 완전히 열린 유동장에서의 유동 재부착 지점에 수렴해간다는 것을 확인하였다. 즉 거리가 멀어질수록 벽면 영향이 줄어든다는 것을 확인하였다. 또한 각각의 경우에 대해 항력계수 값을 구하였고, 이를 완전히 열린 유동장에서의 항력계수 값과 비교해 보았다. 그 결과 벽면으로부터의 떨어진 거리가 5부터 벽면의 효과가 줄어들어 10이상이 되었을 때부터 그 영향이 아주 미미하다는 것을 확인하였다.

  • PDF

Numerical Flow Analysis of a Supersonic Impulse Turbine with Nozzles and Rotor blades (노즐과 로터가 장착된 초음속 충동형 터빈의 전산유동해석)

  • Park, Pyun Goo;Lee, En Seok;Jeong, Eun Hwan;Kim, Jinhan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.445-451
    • /
    • 2004
  • Four design candidates for a 1.4MW class partial admission turbine have been chosen from a Preliminary design process. Their performance were estimated through the 3-D numerical analyses using a frozen rotor method. In order to select the optimum design, each flow analysis result was compared with others. Flow characteristics in the passages and some types of losses induced by shocks and wakes were found from calculation results. Based on these calculations, a new rotor blade was redesigned and compared with previous one through flow analysis.

  • PDF

Effect of impeller geometrical parameter on the performance of a centrifugal (임펠러 형상변수가 원심펌프 성능에 미치는 영향)

  • Kim, Sung;Choi, Young-Seok;Kim, Joon-Hyung;Yoon, Joon-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1303-1308
    • /
    • 2008
  • This paper presents effects of impeller geometrical parameters on the performance of a centrifugal pump impeller. The effects of meridional parameters and vane plane development parameters on the performance of the impeller were numerically studied using a commercial CFD code and DOE(design of experiments) software. Geometrical parameters in a method of meridional view and vane plane development were selected and defined to generate the 3D impeller shape. The response variables are defined in a total head and efficiency curve with flow rate. The influences of selected design variables on the various objective functions were examined as a result of the calculation using 2k factorial.

  • PDF

Development of an axial flow fan for a refrigerator by in-house design system (팬 설계 시스템에 의한 냉장고용 축류팬 개발)

  • 최동규;최원석;박성관
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.2
    • /
    • pp.85-92
    • /
    • 1997
  • An axial flow fan design system has been made by integrating the self-developed programs and I-DEAS. By using the system, an axial flow fan was designed, manufactured and verified through the wind tunnel experiments in coorperation with a refrigerator appliance division. It has been shown that the optimal design without the ambiguity of the design parameters can be possible by the three-dimensional flow simulations using a self-developed CID code, FANS-3D. (Flow Analysis code using Navier Stokes aguations in Three-Dimensional curvilinear coordinates). By virtue of the fluency of the data flow, an optimally designed fan which satisfies design conditions can be selected in a short time and less cost. The manufacturing processes of a Mock-up and an injection molding die have been automated through the self-made interface programs which connnect from the start to the end. It has been shown that the newly developed fan by this system has a superior performance characteristics to an existing fan.

  • PDF

연안해운선의 온실가스 감축기술에 의한 연료절감액 산정

  • Park, Dong-U;Yang, Yeong-Jun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.172-174
    • /
    • 2018
  • 기존선형과 저항을 최소화하는 최적선형에 대한 에너지효율 성능을 평가하는 것이다. 설계 흘수와 설계 선속을 고려하여 대상선박의 선수부 형상을 검토하였다. 실제 운항 상태에서 대상선박의 저항성능을 평가하였다. 상용 전산유체역학(CFD) 코드와 수조 모형시험 자료는 유효마력 평가를 위해 사용되었다. 실제 운항 상태를 고려하여 최소저항을 가지는 최적선형을 제시하였다. 기존선형과 최적선형에 대하여 3가지 선속에서 유효마력을 추정하였다. 최적선형의 저항성능은 기존선형과 비교하여 볼 때 설계속도(12노트)에서 약 6% 향상된 결과를 보여 주었다. 준추진효율 계수(ETAD, ${\eta}D$)는 모형시험 자료를 활용하였다. 에너지 효율 성능은 년간 운항일수, 벙커C유 가격, 1일 연료사용량 그리고 연료소비계수를 바탕으로 작성되었다.

  • PDF

Numerical Simulation: Effects of Gas Flow and Rf Current Direction on Plasma Uniformity in an ICP Dry Etcher

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • v.26 no.6
    • /
    • pp.189-194
    • /
    • 2017
  • Effects of gas injection scheme and rf driving current configuration in a dual turn inductively coupled plasma (ICP) system were analyzed by 3D numerical simulation using CFD-ACE+. Injected gases from a tunable gas nozzle system (TGN) having 12 horizontal and 12 vertical nozzles showed different paths to the pumping surface. The maximum velocity from the nozzle reached Mach 2.2 with 2.2 Pa of Ar. More than half of the injected gases from the right side of the TGN were found to go to the pump without touching the wafer surface by massless particle tracing method. Gases from the vertical nozzle with 45 degree slanted angle soared up to the hottest region beneath the ceramic lid between the inner and the outer rf turn of the antenna. Under reversed driving current configuration, the highest rf power absorption region were separated into the two inner islands and the four peaked donut region.