• 제목/요약/키워드: 3D-CFD

검색결과 673건 처리시간 0.028초

CFD 해석을 이용한 한국도로공사 표준 25 [W] LED 모듈의 방열 특성 분석 (Analysis of Heat Dissipation Characteristics for Standard 25 [W] LED Module of Korea Expressway Corporation: Using CFD Analysis)

  • 이세일;허인성;이아람;정민주;유영문
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.541-546
    • /
    • 2014
  • Korea Expressway Corporation established standard of LED lighting fixture in Dec. 2013. To raise compatibility, the standard requires a fixed form and it is applied to street lights and tunnel lights, etc. Because streetlight has different circumstance condition from tunnel light that is down light and exposed to constant wind velocity over height of 8 meters, in case of LED module which has the same shape, characteristic of radiant heat can be different. In this paper, we designed 25 [W] LED Module that is designated by standard of Korea Expressway Corporation and analyzed characteristics of radiant heat about natural convection and forced convection. It is dropped 10.12[$^{\circ}C$] that max temperature is decreased by increasing 20 mm of bended height of heatsink at the condition of natural convection. Radiant heat characteristic of bended height 35 mm became 78.08[$^{\circ}C$] at the condition of natural convection, 55.30[$^{\circ}C$] at the condition of forced convection so that 22.78[$^{\circ}C$] is decreased that is 29.1[%] decrease. Bended height 55mm became 67.96[$^{\circ}C$] at the condition of natural convection, 48.04[$^{\circ}C$] at the condition of forced convection so that 19.92[$^{\circ}C$] is decreased that is 29.3% decrease.

액체로켓엔진 산화제 배관 시스템 전산유동해석 (Computational Analysis of an LOx Supply Line System of an Liquid Rocket Engine)

  • 문인상;문일윤;이수용
    • Journal of Astronomy and Space Sciences
    • /
    • 제26권4호
    • /
    • pp.693-702
    • /
    • 2009
  • 액체로켓엔진의 구성품 중 하나인 산화제 라인 시스템의 3차원 모델과 유동해석을 수행하였다. 전체 시스템의 유동해석에 앞서 각 구성품들의 개별적인 유동해석과 단순화된 모델을 통해 최적의 위치를 결정하였다. 그 결과 가스발생기 라인의 입구는 압력보상이 필요하며 오리피스의 위치에 따라 출구 유동의 형태가 달라지는 것을 확인할 수 있었다. 전체적으로 해석된 라인 시스템은 주어진 요구조건을 만족하는 것으로 나타났으며 이는 실제 제품 제작과 시험을 통해 확인할 예정이다.

Numerical optimization of flow uniformity inside an under body- oval substrate to improve emissions of IC engines

  • Om Ariara Guhan, C.P.;Arthanareeswaran, G.;Varadarajan, K.N.;Krishnan, S.
    • Journal of Computational Design and Engineering
    • /
    • 제3권3호
    • /
    • pp.198-214
    • /
    • 2016
  • Oval substrates are widely used in automobiles to reduce the exhaust emissions in Diesel oxidation Catalyst of CI engine. Because of constraints in space and packaging Oval substrate is preferred rather than round substrate. Obtaining the flow uniformity is very challenging in oval substrate comparing with round substrate. In this present work attempts are made to optimize the inlet cone design to achieve the optimal flow uniformity with the help of CATIA V5 which is 3D design tool and CFX which is 3D CFD tool. Initially length of inlet cone and mass flow rate of exhaust stream are analysed to understand the effects of flow uniformity and pressure drop. Then short straight cones and angled cones are designed. Angled cones have been designed by two methodologies. First methodology is rotating flow inlet plane along the substrate in shorter or longer axis. Second method is shifting the flow inlet plane along the longer axis. Large improvement in flow uniformity is observed when the flow inlet plane is shifted along the direction of longer axis by 10, 20 and 30 mm away from geometrical centre. When the inlet plane is rotated again based on 30 mm shifted geometry, significant improvement at rotation angle of $20^{\circ}$ is observed. The flow uniformity is optimum when second shift is performed based on second rotation. This present work shows that for an oval substrate flow, uniformity index can be optimized when inlet cone is angled by rotation of flow inlet plane along axis of substrate.

능동 탭 로터 모델링 및 BVI 소음 저감 특성 해석 (Modeling of a Rotor System Incorporating Active Tab and Analysis of BVI Noise Reduction Characteristics)

  • 김도형;강희정;위성용;김승호
    • 한국항공우주학회지
    • /
    • 제41권11호
    • /
    • pp.855-864
    • /
    • 2013
  • 능동 탭은 BVI 소음 저감을 위한 능동제어 기술 중 하나이며, 이를 이용한 소음 저감효과에 대한 해석은 기술 개발에 있어서 매우 중요한 과정의 하나이다. 능동 탭의 소음저감 성능 분석을 위하여 모델 로터시스템에 대한 구조 설계를 수행하고 CFD 해석을 통해 에어포일 공력 데이터를 생성하였으며, 이를 이용하여 통합해석 프로그램인 CAMRAD II 모델을 구성하였다. 하강 비행 상태에서 능동 탭을 HHC 방법으로 작동할 경우 로터에서 발생되는 공력 하중을 CAMRAD II를 이용하여 계산하고, 이에 따른 BVI 소음 변화를 자체 소음해석 프로그램으로 계산하였다. 능동 탭의 작동 길이 및 제어 위상의 변화에 따른 소음해석 결과 최대 -3.3dB의 BVI 소음 저감 효과를 얻을 수 있었다.

EMP 차폐를 위한 도파관 형상과 SE에 따른 유동 특성 평가 (Evaluation of Air Flow Characteristics in accordance with Types of Waveguide-Below-Cutoff (WBC) Arrays and Their Shielding Effectiveness of Electromagnetic Pulse (EMP))

  • 방승기;안혜린;육종관
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권3호
    • /
    • pp.1-8
    • /
    • 2016
  • In this study, we evaluated the flow characteristics of various types of waveguide-below-cutoff (WBC) arrays and their shielding effectiveness (SE) of electromagnetic pulses (EMP) based on computational fluid dynamics (CFD). Three types of waveguides were selected for analysis: (1) grid type, (2) honeycomb type, and (3) multi-layer types (2-ply, 4-ply, 6-ply, and 8-ply). To analyze the air flow characteristics, the flow velocities in the longitudinal center of the WBC and the differential pressures between the WBC array inlet and outlet were evaluated. Consequently, we derive the following conclusions: (1) despite an increase in the inlet velocity, the pressure drop of the 6-ply multi-layer type did not significantly increase as compared to that of other types of waveguides (waveguide thickness of 0.1 mm, SE of 100 dB); (2) the grid and honeycomb type had the fastest flow rate of 17.5 m/s, which is approximately 2.5 m/s faster than that at the inlet (waveguide thickness of 1 mm, module size of 30 mm); and (3) the average pressure drop of the grid type waveguide is the lowest in the overall model, whereas that of the 8-ply is the highest (waveguide thickness of 1 mm, module size of 30 mm, and SE of 80, 100 dB).

전산유체해석과 다구찌 방법을 연계한 공기 가열식 히터 시스템의 난방속효성 최적화에 관한 연구 (A Study on the Optimum Design of Warm-up rate in a Air-Heated Heater System by Using CFD Analysis and Taguchi Method)

  • 김민호
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.72-82
    • /
    • 2005
  • The objective of this paper is to describe the optimization of design parameters in a large-sized commercial bus heater system by using CFD(computational fluid dynamics) analysis and Taguchi method. In order to obtain the best combination of each control factor which results in a desired performance of heater system, the parameter design of the Taguchi method is adopted for the robust design considering the dynamic characteristic. The research activity may be divided into four phases. The first one is analyzing the problem, i.e., ascertaining the influential factors. In the second phase the levels were set in such a way that their variation would significantly influence the response. In the third phase the experimental runs were designed. In the final phase the planned runs were carried out numerically to evaluate the optimal combination of factors which is able to provide the best response. In this study, eight factors were considered for the analysis: one with two level and seven with three level combinations comprising the $L_{18}(2^1{\times}3^7)$ orthogonal array. The results of this study can be summarized as follows ; (i)The optimum condition of control factor is a set of <$A_2\;B_1\;C_3\;D_3\;E_1\;F_2\;G_3\;H_2$> where A is shape of the outer fin, B is pitch of the outer fin, C is height of the outer fin, D is the inner fin number, E is the inner fin height, F is length of the flame guide, G is diameter of the heating element and H is clearance between air guide and heating element. (ii)The heat capacity of heated discharge air under the optimum condition satisfies the equation y=0.6M w here M is a signal factor. (iii)The warm-up rate improves about three times, more largely as com pared with the current condition, which results in about 9.2minutes reduction.

Numerical Cavitation Intensity on a Hydrofoil for 3D Homogeneous Unsteady Viscous Flows

  • Leclercq, Christophe;Archer, Antoine;Fortes-Patella, Regiane;Cerru, Fabien
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.254-263
    • /
    • 2017
  • The cavitation erosion remains an industrial issue for many applications. This paper deals with the cavitation intensity, which can be described as the fluid mechanical loading leading to cavitation damage. The estimation of this quantity is a challenging problem both in terms of modeling the cavitating flow and predicting the erosion due to cavitation. For this purpose, a numerical methodology was proposed to estimate cavitation intensity from 3D unsteady cavitating flow simulations. CFD calculations were carried out using Code_Saturne, which enables U-RANS equations resolution for a homogeneous fluid mixture using the Merkle's model, coupled to a $k-{\varepsilon}$ turbulence model with the Reboud's correction. A post-process cavitation intensity prediction model was developed based on pressure and void fraction derivatives. This model is applied on a flow around a hydrofoil using different physical (inlet velocities) and numerical (meshes and time steps) parameters. The article presents the cavitation intensity model as well as the comparison of this model with experimental results. The numerical predictions of cavitation damage are in good agreement with experimental results obtained by pitting test.

Ristorcelli의 압축성 난류 모형을 이용한 초음속 유동의 계산 (Computations of Supersonic Flow with Ristorcelli′s Compressible Turbulence Model)

  • 박창환;박승오
    • 한국전산유체공학회지
    • /
    • 제8권3호
    • /
    • pp.1-6
    • /
    • 2003
  • Three-dimensional endwall flow within a linear cascade passage of high performance turbine blade is simulated with a 3-D Wavier-Stokes CFD code (MOSA3D), which is based on body-fitted coordinate system, pressure-correction and finite volume method. the endwall flow characteristics, including the development and generation of horseshoe vortex, passage vortex, etc. are clearly simulated, consistent with the generally known tendency The effects of both turbulence model and convective differencing scheme on the Prediction performance of endwall flow are systematically analyzed in the present paper. The convective scheme is found to have stronger effect than the turbulence modei on the prediction performance of endwall flow. The present simulation result also indicates that the suction leg of the horseshoe vortex continues on the suction side until it reaches the trailing edge.

냉각 팬의 설계에 의한 유동저항에 관한 연구 (Study on Flow Resistance by the Design of Cooling Fan)

  • 조재웅
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.41-47
    • /
    • 2011
  • In this study, the structural analysis of cooling fan is combined with 3-D flow analysis by using CFD on fluid domain. The smoothly cooling flow with optimum design of cooling parts is essential at automotive combustion engine. The fan shape is modeled with three kinds of shape by varying the radius of the fan blade. By the results of analysis, the flow at Model I is more uniform than Model II or III. And the displacement at Model I is less than Model II or III. As the flow resistance of cooling fan at Model I decreases more than Model II or III, the efficiency becomes better.

원심압축기용 베인디퓨져의 탈설계점 성능연구 - 제1부 : 채널디퓨져 - (Investigation of Off-Design Performance of Vaned Diffusers in Centrifugal Compressors - Part I : A Channel-Wedge Diffuser -)

  • 오종식;현용익
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.83-90
    • /
    • 2001
  • Experimental and numerical investigations of the off·design performance of a simple channel-wedge diffuser in a small centrifugal compressor are presented. Surge and choke conditions as well as design point are considered using somewhat limited range of experimental data and also supplementary 3D CFD results. Some critical meanline design parameters' behavior is investigated numerically, to render the basis for improved modelings in the meanline performance prediction.

  • PDF