• Title/Summary/Keyword: 3D surface matching

Search Result 96, Processing Time 0.022 seconds

Miniaturization of GPS Microstrip Antenna for Small Drone (초소형 드론 탑재용 GPS 대역 마이크로스트립 안테나의 소형화)

  • Kim, Wan-Ki;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.3
    • /
    • pp.62-72
    • /
    • 2022
  • In this study, a miniaturized GPS band(L1 : 1.575 GHz) antenna that can be mounted on a small drone is proposed. The miniaturization was designed by applying the perturbation method based on the λ/4 microstrip antenna and lengthening the current path at the edge of the patch. The miniaturized antenna was fabricatred such that it could be attached to the surface of styrofoam(εr=1.06, t=10 mm) having a size of 10 mm × 9 mm × 10 mm (0.05 λ × 0.05 λ × 0.05 λ). The thickness and length of the feeding line and the spacing between short stubs were adjusted for impedance matching. S11 was found to be -18.8 dB at the center frequency of the fabricated antenna, 1.575 GHz. The radiation pattern measurement results show that the maximum gain of Eθ is 1.87 dBi in 0 directions in the xz-plane, and that Eθ is an omnidirectional characteristic with an average gain of -1.7 dBi in the yz-plane. It was found that the antenna can be used as an ultra-small microstrip antenna, which can be mounted on a small dron for GPS, and is capable of preserving a reduction ratio of 98.8% as compared to a λ/2 microstrip patch antenna.

Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device (방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발)

  • Dong-Sik Jin;Kyeong-Ryeong Kim;Jae-Geun Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

A Study on Matching Method of Hull Blocks Based on Point Clouds for Error Prediction (선박 블록 정합을 위한 포인트 클라우드 기반의 오차예측 방법에 대한 연구)

  • Li, Runqi;Lee, Kyung-Ho;Lee, Jung-Min;Nam, Byeong-Wook;Kim, Dae-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • With the development of fast construction mode in shipbuilding market, the demand on accuracy management of hull is becoming higher and higher in shipbuilding industry. In order to enhance production efficiency and reduce manufacturing cycle time in shipbuilding industry, it is important for shipyards to have the accuracy of ship components evaluated efficiently during the whole manufacturing cycle time. In accurate shipbuilding process, block accuracy is the key part, which has significant meaning in shortening the period of shipbuilding process, decreasing cost and improving the quality of ship. The key of block accuracy control is to create a integrate block accuracy controlling system, which makes great sense in implementing comprehensive accuracy controlling, increasing block accuracy, standardization of proceeding of accuracy controlling, realizing "zero-defect transferring" and advancing non-allowance shipbuilding. Generally, managers of accuracy control measure the vital points at section surface of block by using the heavy total station, which is inconvenient and time-consuming for measurement of vital points. In this paper, a new measurement method based on point clouds technique has been proposed. This method is to measure the 3D coordinates values of vital points at section surface of block by using 3D scanner, and then compare the measured point with design point based on ICP algorithm which has an allowable error check process that makes sure that whether or not the error between design point and measured point is within the margin of error.

A STUDY ON THE COLOR CHANGES ACCORDING TO THE AMOUNT OF REMAINING TOOTH MATERIAL (치질(齒質) 잔존량(殘存量)에 따른 색조변화(色調變化)에 관(關)한 연구(硏究))

  • Hoh, Sung-Yun;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.131-147
    • /
    • 1986
  • The purpose of this study was to observe the color matching of lining or filling materials according to the remaining tooth material. Twenty-seven freshly extracted human central incisors were used in this experiments. The teeth were stored in saline solution at room temperature after extraction. All teeth were cut parallel to the tangent to height of contour on labial surface from the lingual surface until the pulp were completely removed. Then 27 teeth were devided into 0.5mm, 1.0mm and 1.5mm reduction groups according to the thickness of cutting the lingual surfaces of teeth. The specimens of control group were three teeth of 27 teeth with cutting the lingual surface same mode as above described. In the specimens of experimental groups, 8 kinds of lining and filling materials; FUJI IONOMER TYPE II (G-C Co. Japan), LINING CEMENT (G-C Co. Japan), Dycal (Caulk, U.S.A.), CLEARFIL F II (Kuraray Co. Japan), Crown Bridge & Inlay Cement (G-C Co. Japan), Copalite (Harry J. Bosworth Co. U.S.A.), HY-BOND (G-C Co. Japan) and LIV-CENERA (G-C Co. Japan); applied on the back of 24 teeth with 0.5mm, 1.0mm and 1.5mm cut thickness of lingual surfaces. Three teeth of control group did not applied linging or filling materials on the back of 3 kinds of different thickness of cutting the lingual surfaces. The absorbances of total 27 specimens were obtained by reflection spectrophotometer. (Cary 17 D, Varian Co, U.S.A.) The following conclusions were drawn from above the results; 1. The absorbance patterns in both experiment and control groups were gradually decreased with increasing wavelength of spectra. 2. The absorbance patterns were not decreased in relation to the kinds of lining or filling materials, but the amount of the remaining tooth materials. 3. In 0.5mm reduction group, FUJI IONOMER TYPE II, LINING CEMENT, LIV-CENERA and Copalite applied on the back of cut lingual surface showed similar absorbance patterns as control group. 4. The specimens which were reduced up to 1.0mm thickness and lined with FUJI IONOMER TYPE II and LINING CEMENT showed the comparable absorbance patterns to the control group. 5. In case of HY-BOND application after 1.5mm reduction were observed the similar absorbance pattern as compared with control group. 6. When Dycal, CLEARFIL and Crown Bridge & Inlay Cement were applied to cut teeth surfaces, there were much differences of absorbance between control groups and experimental groups.

  • PDF

Design of Wideband Bow-Tie Antenna with Folded-Slit Band-Notch Structure (폴디드 슬릿 대역저지 구조를 적용한 광대역 보우타이 안테나 설계)

  • Nam, Hyun-Soo;Woo, Dong Sik;Kim, Sung-Kyun;Kim, In-Bok;Choi, Hyun-Chul;Kim, Kang Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.9
    • /
    • pp.886-894
    • /
    • 2014
  • A wideband bow-tie antenna fed by wideband microstrip-coplanar stripline(CPS) balun and band notch structures that can be applied to bow-tie antenna are proposed in this paper. In order to increase bandwidth, bow-tie radiators are reshaped so that the surface current flows continuously, and wideband impedance matching is achieved by adjusting strip width and spacing of CPS feeding line. The VSWR is measured as 2:1 over the wide frequency range of 2.3~12 GHz. The fabricated antenna size is $60mm{\times}60mm$. In order to achieve the band-notch function at WLAN(5.8 GHz), ${\lambda}/4$ folded-slits located ${\lambda}/4$ away from feeding point are utilized. To minimize the slit size, folded-slit type is adopted. The measured VSWR is 7:1 and gain attenuation is 14 dB at 5.8 GHz.

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF