• Title/Summary/Keyword: 3D resistivity structure

Search Result 82, Processing Time 0.026 seconds

Structural-Health Evaluation for Core Zones of Fill Dams in Korea using Electrical Resistivity Survey and No Water Boring Method (전기비저항 탐사와 무수보링을 이용한 국내 필 댐 코어존의 건전성 평가)

  • Lee, Sangjong;Lim, Heuidae;Park, Dongsoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.21-35
    • /
    • 2015
  • Electrical resistivity survey (2D and 3D) were employed for detection of possible weak zone of core zones of three central core earth-rockfill dams in Korea. In the 2D results, the core zones is lower resistivity zone with less than $50{\sim}400ohm{\cdot}m$, and the basement is relatively higher resistivity zone with over $1,000ohm{\cdot}m$. In the 3D results, especially, the weak zone with under $100ohm{\cdot}m$ was detected spatial distribution area in the dam. We also drilled boreholes to collect soil samples of core zones of each dam. Water was not used during boring, because water for rotary wash boring could cause structural damages in earth dams. We found that the soil samples of core zones from all of the boreholes correspond to CL (USCS), but we also found that the fluidized or water-saturated soil samples were found in lower resistivity zones. Therefore, the electrical resistivity survey and drilling method without water are a quick and efficient method for structural-health evaluation which is detection of possible weak zones in earth core rockfill dams.

3-D Geological Structure Interpretation by the Integrated Analysis of Magnetotelluric and Gravity Model at Hwasan Caldera (자기지전류 및 중력 모델의 복합해석을 통한 화산칼데라 지역의 3차원 지질구조 해석)

  • Park, Gye-Soon;Lee, Chun-Ki;Yang, Jun-Mo;Lee, Heui-Soon;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.32 no.6
    • /
    • pp.548-559
    • /
    • 2011
  • 3-D Multi-geophysical surveys were carried out around the Hwasan caldera at the Euisung Sub-basin. To overcome the limitations of resolutions in previous studies, dense gravity data and magnetotelluric (MT) data were obtained and analyzed. In this study, the independent inversion models from gravity and MT data were integrated using correlation and classification approaches for 3-D imaging of the geologic structures. A Structure Index (SI) method was proposed and applied to the integration and classification analyses. This method consists of Type Angle (TA) and Type Intensity (TI) values, which are estimated by the spatial correlation and abnormality of the physical properties. The SI method allowed the classification analysis to be effectively performed. Major findings are as follows: 1) pyroclastic rocks around the central area of the Hwasan caldera with lower density and resistivity than those of neighboring regions extended to a depth of around 1 km, 2) intrusive igneous rocks with high resistivity and density were imaged around the ring fault boundary, and 3) a basement structure with low resistivity and high density, at a depth of 3-5 km, was inferred by the SI analysis.

A Study on Material Properties and Fabrication of ITO Thin Films by Unbalanced-Magnet Structure in Magnetron Sputtering (DC 마그네트론 스파터링의 비대칭 자석강조에 의한 ITO 박막 제조 및 물성에 관한 연구)

  • 신성호;김현후;박광자
    • Electrical & Electronic Materials
    • /
    • v.10 no.7
    • /
    • pp.700-705
    • /
    • 1997
  • Transparent conducting indium tin oxide (TC-ITO) thin films are deposited on soda lime glass by a dc magnetron sputtering technique having the unbalanced-magnet structure in order to improve the electrical/material characteristics and to avoid the surface damages. The material properties are measured by the x-ray diffractometer (XRD) and atomic force microscope (AFM). The (400) peak as the preferred orientation of <100> direction for ITO thin films is stabilized with the increase of substrate temperature. The surface roughness estimated by AFM 3D image at the substrate temperature of 40$0^{\circ}C$ is extremely uniform. The best resistivity of ITO films (5500 $\AA$ thick) at 40$0^{\circ}C$ is about 1.3$\times$10$^{-4}$ $\Omega$cm on the position of 4 cm from substrate center.

  • PDF

The Effects of Additions of In & Sb on Resistivity & Sensitivity in Tin Oxide Gas Sensors (In과 Sb의 첨가가 Tin Oxide 가스센서에서 Resistivity와 Sensitivity에 미치는 영향)

  • Son, Y.M.;Han, S.D.;Kim, J.W.;Sim, K.S.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.165-172
    • /
    • 1992
  • To determine the effect of additions of trivalent and pentavalent ions on the electrical conductivity and sensing behaviour, indium and antimony were incorporated in tin oxide by the coprecipitation method. Antimony may be considered to enter the cassiterite structure as pentavalent ions, thermal energy could excite electrons from these ions into the conduction band. Similarly the indium ions would enter the lattice as $In^{3+}$ but could accept electrons from the valence band, thereby becoming monovalent or divalent. These phenomena, however, how the potential barrier existing $SnO_{2}$ by addition of two kinds of ions could influence on the sensing behaviour in comparison with their influence on the resistivity were observed.

  • PDF

1-D Deep Resistivity Structure of the Korean Peninsula Using Magnetotelluric(MT) Data (MT 자료를 이용한 한반도의 심부 1차원 전기비저항 구조 연구)

  • Yang, Jun-Mo;Lee, Heui-Soon;Lee, Chun-Ki;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.30 no.2
    • /
    • pp.153-164
    • /
    • 2009
  • We examined the regional 1-D deep resistivity structure of the Korean Peninsula using MT data acquired at seven sites located in the Kyongsang Basin and Kyonggi Massif. At the sites located in the Kyongsang Basin, surrounding sea distorts observed MT response and hence this distortion, so called "sea effect", is corrected using an iterative tensor stripping method. The 1-D layered inversion results for the seven MT sites reveal 4 layered structure, which is composed of 1) near surface layer, 2) upper crust, 3) lower crust and upper mantle, and 4) asthenosphere from the surface downward. Conrad interface, which is a boundary between upper and lower crust, is distinctly identified beneath all the MT sites. Conrad interface depth is estimated to about be 17km in the Kyongsang Basin and about 12km in the Kyonggi Massif, while the upper crust of the Kyongsang Basin is about 5 times more resistive than that of the Kyonggi Massif. Finally, asthenosphere is inferred to exist below a depth of approximately 100km with a resistivity of 200-300 ohm-m.

Analysis of Environmental Hazard by the Leachate from Disposal Waste (매립장 침출수 환경 재해에 관한 연구)

  • Kim, Jun-Kyoung;Bae, Hyo-Jun;Choi, Oh-Soon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.4 s.11
    • /
    • pp.145-151
    • /
    • 2003
  • The domestic and the industry wastes which mainly come out of human life activities have been usually processed mainly by the incineration method and/or the method of reclamation. The method of reclamation, specially open dumping, has caused significant environmental pollution problems on the local or regional soil and groundwater system by leachate. Therefore, to investigate the 3-D structure characteristics of environmental pollution area is one of the hot subjects. We applied dipole-dipole method of electrical resistivity survey to investigate 3-D environmental contamination characteristics of the Noeun landfill area. For electrical resistivity survey, the line for measurements was established parallel to the main boundary of the Noeun landfill, for effective investigation of the whole landfill area. The result shows that the uppermost layer of the Noeun landfill is believed to be stabilized completely, based on the result of electrical resistivity values. However, the lowest layer of the Noeun landfill was partially polluted by leachate. Therefore, the electrical resistivity survey method is believed to be the one of the most effective methods to investigate three-dimensional distribution of leachate occurred in the lower part of landfill area.

Application of 3D magnetotelluric investigation for geothermal exploration - Examples in Japan and Korea

  • Uchida Toshihiro;Song Yoonho;Mitsuhata Yuji;Lee Seong Kon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.390-397
    • /
    • 2003
  • A three-dimensional (3D) inversion technique has been developed for interpretation of magnetotelluric (MT) data. The inversion method is based on the linearized least-squares (Gauss-Newton) method with smoothness regularization. In addition to the underground 3D resistivity distribution, static shifts are also treated as unknown parameters in the inversion. The forward modeling is by the staggered-grid finite difference method. A Bayesian criterion ABle is applied to search the optimum trade-off among the minimization of the data misfit, model roughness and static shifts. The method has been applied to several MT datasets obtained at geothermal fields in Japan and other Asian countries. In this paper, two examples will be discussed: one is the data at the Ogiri geothermal area, southwestern Japan, and the other is at the Pohang low-enthalpy geothermal field, southeastern Korea. The inversion of the Ogiri data has been performed stably, resulting in a good fitting between the observed and computed apparent resistivities and phases. The recovered 3D resistivity structure is generally similar to the two-dimensional (2D) inversion models, although the deeper portion of the 3D model seems to be more realistic than that of the 2D model. The 3D model is also in a good agreement with the geological model of the geothermal reservoirs. 3D interpretation of the Pohang MT data is still preliminary. Although the fitting to the observed data is very good, the preliminary 3D model is not reliable enough because the station coverage is not sufficient for a 3D inversion.

  • PDF

An Electrical Resistivity Survey for Leachate Investigation at a Solid Waste Landfill (폐기물 매립지 침출수 조사를 위한 전기비저항 탐사)

  • Lee, Keun-Soo;Cho, In-Ky;Mok, Jong-Koo;Kim, Jeong-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.2
    • /
    • pp.59-66
    • /
    • 2016
  • The electrical resistivity method is an effective geophysical tool to detect subsurface contamination because the contaminated zones show generally lower electrical resistivity. In this study, the electrical resistivity surveys were applied to a waste landfill site to image the subsurface structure around the landfill and to identify the contaminated zones. First, the dipole-dipole 2D resistivity surveys were conducted along the boundaries of landfill to define the developed contaminated zones. Then the crosshole resistivity tomography was applied to confirm the suspected contaminated zones at depth. The results of drilling and geochemical analysis of ground water supported that the low resistivity zones coincide well with the contaminated zones and the leachate pathways could be delineated effectively from the resistivity survey.

Preparation and PTC properties of thin films $BaTiO_3$ ceramic system using RF/DC magnetron sputtering method (RF/DC 마그네트론 스퍼터법을 이용한 $BaTiO_3$계 세라믹 박막의 제조와 PTC특성)

  • 박춘배;송민종;김태완;강도열
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.77-82
    • /
    • 1995
  • PTCR(Positive Temperature Coefficient of Resistivity) thermistor in thin film BaTiO$_{3}$ system was prepared by using radio frequency(13.56 MHz) and DC magnetron sputter equipment. Polycrystalline, surface structure, and R-T(Resistivity-Temperature) characteristics of the specimens were measured by X-ray diffraction(D-Max3, Rigaku, Japan), SEM(Scanning Electron Microscopy: M.JSM84 01, Japan), and insulation resistance measuring system (Keithley 719), respectively. Thin films characteristics of the thermistor showed different properties depending on the substrate even with the same sputtering condition. The thin film formed on the A1$_{2}$O$_{3}$ substrate showed a good crystalline and a low resistivity at below curie point. However, the thin films prepared on slide glass and Si wafer were amorphous. The thicknesses of the three samples prepared under the same process conditions were 700[.angs.], 637.75[.angs.], and 715[.angs.], respectively.

  • PDF

3-D Inversion of 3-D Synthetic DC Resistivity Data for Vein-type Ore Deposits (국내 맥상광체조사를 위한 3차원 전기비저항 모델링자료의 3차원 역산 해석)

  • Lee, Ho-Yong;Jung, Hyun-Key;Jeong, Woo-Don;Kwak, Na-Eun;Lee, Hyo-Sun;Min, Dong-Joo
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.699-708
    • /
    • 2009
  • Recently as the interest in the development of domestic ore deposits has increased, we can easily find some studies on exploration geophysics-based ore-deposit survey in literature. Based on the fact that mineralized zone are generally more conductive than surrounding media, electrical resistivity survey among several geophysical surveys has been applied to investigate metallic ore deposits. Most of them are grounded on 2-D survey. However, 2-D inversion may lead to some misinterpretation for 3-D geological structures. In this study, we investigate the feasibility of the 3-D electrical resistivity survey to 3-D vein-type ore deposits. We first simulate 2-D dipole-dipole survey data for survey lines normal to the strike and 3-D pole-pole survey data, and then perform 3-D inversion. For 3-D ore-body structures, we assume a width-varying dyke, a wedge-shaped, and a fault model. The 3-D inversion results are compared to 2-D inversion results. By comparing 3-D inversion results for 2-D dipole-dipole survey data to 3-D inversion results for 3-D pole-pole survey data, we could note that the 2-D dipole-dipole survey data yield better inversion results than the 3-D pole-pole data, which is due to the main characteristic of the pole-pole array. From these results, we are convinced that if we have certain information on the direction of the strike, it would be desirable to apply 2-D dipole-diple survey for the survey lines normal to the strike. However, in most cases, we do not have any information on the direction of the strike, because we already developed the ore deposit with the outcrops and the remaining ore deposits are buried under the surface. In that case, performing 3-D pole-pole electrical resistivity survey would be a reasonable choice to obtain more accurate interpretation on ore body structure in spite of low resolution of pole-pole array.