• 제목/요약/키워드: 3D reconstruction computed tomography

검색결과 84건 처리시간 0.02초

Cone-Beam CT를 이용한 악교정 수술용 스텐트 제작과 임상 적용 (SURGICAL STENT FABRICATION AND CLINICAL APPLICATION FOR ORTHOGNATHIC SURGERY USING Cone-Beam CT)

  • 김용일;김종렬;김성식;손우성;박수병
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.158-166
    • /
    • 2009
  • The application of CT with basis on 3 dimensional-reconstruction is getting more widely practiced. With the data obtained from cone-beam computed tomography(CBCT), not only the diagnosis of the patient with skeletal abnormality but also the virtual simulation of the orthognathic surgery were performed and its application would be popular in orthodontic field. We reported a case, a 19-year old man who was diagnosed mandibular prognathism and required orthognatic surgery. In this case, the virtual orthognathic surgery was simulated and surgical wafer was fabricated by using CBCT data. That wafer was applied the actual orthognathic surgery. After preoperative orthodontic treatment, we prepared surgery as follows. : (l)Acquisition of 3D image data, (2)Reconstruction of 3-dimensional virtual model, (3)Virtual model surgery, (4)Extraction of stere-olithographic image, (5)Check-up for occlusal interference, (6)Fabrication of surgical stent by stereolithography. Bilateral sagittal split ramus osteotomy was operated and used stereolithographic surgical stent. 1 month later, we superimposed CBCT datas of virtual surgery and that of actual surgery, and then compared the result. CT data's application for othognathic surgery yielded satisfactory outcomes.

자발광 확산 사각화염 내부 구조의 단층 진단 (Tomographic Reconstruction of a Non-axisymmetric Diffusion Flame)

  • 양인영;하광순;최상민
    • 한국연소학회지
    • /
    • 제4권1호
    • /
    • pp.105-115
    • /
    • 1999
  • The structure of a non-axisymmetric propane diffusion flame was investigated. Tomographic reconstruction method to convert the line-integrated self-emission data of a fuel-rich diffusion flame with square cross-section was applied to get the spatially reconstructed emission data. Modified Shepp-Logan filter and concentric squares raster were chosen for reconstructing arbitrarily shaped object in this process. Spatially reconstructed emission data were then interpreted to several physical quantities, such as flame edge, FWHM, perimeter and 3-D flame temperature distribution. Necessary assumptions were discussed and the results were interpreted. In comparison with axisymmetric flame, flame edge was developed higher, and sooting region of upstream was broader than in this non-axisymmetric one. At some height, the flame was shrunk very rapidly and finally formed circular cross-section.

  • PDF

위암 진단에 있어서의 CT 위장 조영술과 상부위장관 조영술과의 비교 (Usefullness of CT Gastrography and Vurtual Gastroscopy using Computed Tomography in Detection of Gastric Cancer)

  • 백용해;이순진;이지연;노재형;손태성;김성;김용일
    • Journal of Gastric Cancer
    • /
    • 제3권4호
    • /
    • pp.195-200
    • /
    • 2003
  • Purpose: Advancement of computed tomography (CT) hardware and software has allowed thin section scanning and reconstruction of fascinating 2-dimentional (2D) and 3- dimentional (3D) images. Especially, the reconstruction of 3D images of gastrointestinal tract has been used in the detection and diagnosis of pre-malignant and malignant diseases. To compare the efficacy of CT gastrography with conventional upper gastrointenstinal series (UGIs) in gastric cancer patients. Materials and Methods: During Nov. 2002 and Mar. 2003, twenty-seven patients who had gastric cancer received both double contrast upper GI series and CT gastrography prior to radical surgery. Among these patients, nineteen had early gastric cancer (EGC) and 8 had advanced gastric cancer (AGC). Fifteen patients were male and 12 were female. The mean age was 54 yrs (range, $27\∼75$ yrs). The patients were placed on NPO and Stomach was distended with gas in fasting state prior to CT scanning. Double contrast upper GI series were performed as routine manual. CT scan was conducted in all patients using 8 or 16-channel multidetector CT in this study. The collimation and reconstruction for CT scanning were set at 2.5 mm and 1.25 mm, respectively. CT scanning was performed in the supine position. For image processing, CT gastrography, in which raysum and surface rendering images were constructed, virtual and 2D image in coronal and sagittal images were performed. The detectability of gastric cancer was assessed between UGIs and CT gastrography. Results: In AGCs, the detection rate of cancer using CT gastrography and virtual gastroscopy was higher than EGC cases. However, CT gastrography and virtual gastroscopy showed less favorable results than UGIs. Even though only a small number of cases had been studied, we might conclude that CT gastrography and virtual gastroscopy could replace UGIs in the detection of AGC cases. Conclusion: The detection rate used with CT gastrography and Virtual gastroscopy is not better than that of UGIs in early gastric cancer, however, in advanced gastric cancer cases, it is nearly equal to that of UGIs.

  • PDF

Three-dimensional and topographic relationships between the orbital margins with reference to assessment of eyeball protrusion

  • Shin, Kang-Jae;Lee, Shin-Hyo;Koh, Ki-Seok;Song, Wu-Chul
    • Anatomy and Cell Biology
    • /
    • 제50권1호
    • /
    • pp.41-47
    • /
    • 2017
  • This study investigated the topographic relationships among the eyeball and four orbital margins with the aim of identifying the correlation between orbital geometry and eyeball protrusion in Koreans. Three-dimensional (3D) volume rendering of the face was performed using serial computed-tomography images of 141 Koreans, and several landmarks on the bony orbit and the cornea were directly marked on the 3D volumes. The anterior-posterior distances from the apex of the cornea to each orbital margin and between the orbital margins were measured in both eyes. The distances from the apex of the cornea to the superior, medial, inferior, and lateral orbital margins were 5.8, 5.8, 12.0, and 17.9 mm, respectively. Differences between sides were observed in all of the orbital margins, and the distances from the apex of the cornea to the superior and inferior orbital margins were significantly greater in females than in males. The anterior-posterior distance between the superior and inferior orbital margins did not differ significantly between males (6.3 mm) and females (6.2 mm). The data obtained in this study will be useful when developing practical guidelines applicable to forensic facial reconstruction and orbitofacial surgeries.

Preliminary Report of Three-Dimensional Reconstructive Intraoperative C-Arm in Percutaneous Vertebroplasty

  • Shin, Jae-Hyuk;Jeong, Je-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권2호
    • /
    • pp.120-123
    • /
    • 2012
  • Objective : Percutaneous vertebroplasty (PVP) is usually carried out under three-dimensional (2D) fluoroscopic guidance. However, operative complications or bone cement distribution might be difficult to assess on the basis of only 2D radiographic projection images. We evaluated the feasibility of performing an intraoperative and postoperative examination in patients undergoing PVP by using three-dimensional (3D) reconstructive C-arm. Methods : Standard PVP procedures were performed on 14 consecutive patients by using a Siremobil Iso-$C^{3D}$ and a multidetector computed tomography machine. Post-processing of acquired volumetric datasets included multiplanar reconstruction (MPR) and surface shaded display (SSD). We analyzed intraoperative and immediate postoperative evaluation of the needle trajectory and bone cement distribution. Results : The male : female ratio was 2 : 12; mean age of patients, 70 (range, 77-54) years; and mean T score, -3.4. The mean operation time was 52.14 min, but the time required to perform and post-process the rotational acquisitions was 7.76 min. The detection of bone cement distribution and leakage after PVP by using MPR and SSD was possible in all patients. However, detection of the safe trajectory for needle insertion was not possible. Conclusion : 3D rotational image acquisition can enable intra- or post-procedural assessment of vertebroplasty procedures for the detection of bone cement distribution and leakage. However, it is difficult to assess the safe trajectory for needle insertion.

The utility of three-dimensional models in complex microsurgical reconstruction

  • Ogunleye, Adeyemi A.;Deptula, Peter L.;Inchauste, Suzie M.;Zelones, Justin T.;Walters, Shannon;Gifford, Kyle;LeCastillo, Chris;Napel, Sandy;Fleischmann, Dominik;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • 제47권5호
    • /
    • pp.428-434
    • /
    • 2020
  • Background Three-dimensional (3D) model printing improves visualization of anatomical structures in space compared to two-dimensional (2D) data and creates an exact model of the surgical site that can be used for reference during surgery. There is limited evidence on the effects of using 3D models in microsurgical reconstruction on improving clinical outcomes. Methods A retrospective review of patients undergoing reconstructive breast microsurgery procedures from 2017 to 2019 who received computed tomography angiography (CTA) scans only or with 3D models for preoperative surgical planning were performed. Preoperative decision-making to undergo a deep inferior epigastric perforator (DIEP) versus muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flap, as well as whether the decision changed during flap harvest and postoperative complications were tracked based on the preoperative imaging used. In addition, we describe three example cases showing direct application of 3D mold as an accurate model to guide intraoperative dissection in complex microsurgical reconstruction. Results Fifty-eight abdominal-based breast free-flaps performed using conventional CTA were compared with a matched cohort of 58 breast free-flaps performed with 3D model print. There was no flap loss in either group. There was a significant reduction in flap harvest time with use of 3D model (CTA vs. 3D, 117.7±14.2 minutes vs. 109.8±11.6 minutes; P=0.001). In addition, there was no change in preoperative decision on type of flap harvested in all cases in 3D print group (0%), compared with 24.1% change in conventional CTA group. Conclusions Use of 3D print model improves accuracy of preoperative planning and reduces flap harvest time with similar postoperative complications in complex microsurgical reconstruction.

흉부 CT 검사에서 3차원 체적 영상의 정량적 분석 (Quantitative analysis of three dimensional volumetric images in Chest CT)

  • 장현철;조재환;박철수
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.255-260
    • /
    • 2011
  • 본 연구는 흉부 CT 검사 시 늑골 골절 환자를 대상으로 3차원 체적 재구성 기법의 유용성에 대해 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 3차원 체적 영상 기법(VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 늑골 골절 환자의 흉부 CT 검사 시 조영 전 원 자료를 이용하여 3차원 체적영상으로 재구성 하는 것이 보다 더 인공 음영을 최소화 시켰으며, 늑골 골절 판단 및 3차원 체적 영상 재구성 소요시간이 단축 됨을 알 수 있었다.

3D Segmentation for High-Resolution Image Datasets Using a Commercial Editing Tool in the IoT Environment

  • Kwon, Koojoo;Shin, Byeong-Seok
    • Journal of Information Processing Systems
    • /
    • 제13권5호
    • /
    • pp.1126-1134
    • /
    • 2017
  • A variety of medical service applications in the field of the Internet of Things (IoT) are being studied. Segmentation is important to identify meaningful regions in images and is also required in 3D images. Previous methods have been based on gray value and shape. The Visible Korean dataset consists of serially sectioned high-resolution color images. Unlike computed tomography or magnetic resonance images, automatic segmentation of color images is difficult because detecting an object's boundaries in colored images is very difficult compared to grayscale images. Therefore, skilled anatomists usually segment color images manually or semi-automatically. We present an out-of-core 3D segmentation method for large-scale image datasets. Our method can segment significant regions in the coronal and sagittal planes, as well as the axial plane, to produce a 3D image. Our system verifies the result interactively with a multi-planar reconstruction view and a 3D view. Our system can be used to train unskilled anatomists and medical students. It is also possible for a skilled anatomist to segment an image remotely since it is difficult to transfer such large amounts of data.

Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report

  • Takano, Masayuki;Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Homma, Shinya;Abe, Shinichi;Katakura, Akira;Shibahara, Takahiko
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.43.1-43.5
    • /
    • 2019
  • Background: Reconstructive surgery is often required for tumors of the oral and maxillofacial region, irrespective of whether they are benign or malignant, the area involved, and the tumor size. Recently, three-dimensional (3D) models are increasingly used in reconstructive surgery. However, these models have rarely been adapted for the fabrication of custom-made reconstruction materials. In this report, we present a case of maxillary reconstruction using a laboratory-engineered, custom-made mesh plate from a 3D model. Case presentation: The patient was a 56-year-old female, who had undergone maxillary resection in 2011 for intraoral squamous cell carcinoma that presented as a swelling of the anterior maxillary gingiva. Five years later, there was no recurrence of the malignant tumor and a maxillary reconstruction was planned. Computed tomography (CT) revealed a large bony defect in the dental-alveolar area of the anterior maxilla. Using the CT data, a 3D model of the maxilla was prepared, and the site of reconstruction determined. A custom-made mesh plate was fabricated using the 3D model (Okada Medical Supply, Tokyo, Japan). We performed the reconstruction using the custom-made titanium mesh plate and the particulate cancellous bone and marrow graft from her iliac bone. We employed the tunneling flap technique without alveolar crest incision, to prevent surgical wound dehiscence, mesh exposure, and alveolar bone loss. Ten months later, three dental implants were inserted in the graft. Before the final crown setting, we performed a gingivoplasty with palate mucosal graft. The patient has expressed total satisfaction with both the functional and esthetic outcomes of the procedure. Conclusion: We have successfully performed a maxillary and dental reconstruction using a custom-made, pre-bent titanium mesh plate.

The effect of fixation plate use on bone healing during the reconstruction of mandibular defects

  • Hong, Khang Do Gia;Kim, Seong-Gon;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권5호
    • /
    • pp.276-284
    • /
    • 2019
  • Objectives: This study sought to compare efficiency results between the use of a customized implant (CI) and a reconstruction plate (RP) in mandibular defect reconstruction in an animal model. Materials and Methods: Fifteen rabbits underwent surgery to create a defect in the right side of the mandible and were randomly divided into two groups. For reconstruction of the mandibular defect, the RP group (n=5) received five-hole mini-plates without bone grafting and the CI group (n=10) received fabricated CIs based on the cone-beam computed tomography (CBCT) data taken preoperatively. The CI group was further divided into two subgroups depending on the time of CBCT performance preoperatively, as follows: a six-week CI (6WCI) group (n=5) and a one-week CI (1WCI) group (n=5). Daily food intake amount (DFIA) was measured to assess the recovery rate. Radiographic images were acquired to evaluate screw quantity. CBCT and histological examination were performed in the CI subgroup after sacrifice. Results: The 1WCI group showed the highest value in peak average recovery rate and the fastest average recovery rate. In terms of reaching a 50% recovery rate, the 1WCI group required the least number of days as compared with the other groups ($2.6{\pm}1.3days$), while the RP group required the least number of days to reach an 80% recovery rate ($7.8{\pm}2.2days$). The 1WCI group showed the highest percentage of intact screws (94.3%). New bone formation was observed in the CI group during histological examination. Conclusion: Rabbits with mandibular defects treated with CI showed higher and faster recovery rates and more favorable screw status as compared with those treated with a five-hole mini-plate without bone graft.