• 제목/요약/키워드: 3D reconstructed CT

검색결과 138건 처리시간 0.029초

경부 종물 환자의 이해도 개선을 위한 3차원 재건 영상의 활용 (3D Reconstructed Image of Neck Mass to Improve Patient's Understanding)

  • 유영삼
    • 대한두경부종양학회지
    • /
    • 제26권2호
    • /
    • pp.193-197
    • /
    • 2010
  • Objectives : Patients with neck tumor and their family need every information about the disease. Especially, the size and location are confusing with verbal information. With the aid of CT, the problem had some answer, but it needs some medical education. We would like to know the usefullness of 3D reconstructed images in patient education about the disease. Material and Methods : Neck CT data were collected from 10 patients with various neck tumors and converted to 3D reconstructed images. Understanding of the patients about the size and location of tumors were rated from questionaires using axial CT images and 3D images. Results : Understanding score about 3D images were greater than that of CT images(p<0.006). Conclusion : 3D reconstructed images of CT could give the patients more real visual information about the disease.

Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

  • Kim, Hyungsuk;Yoo, Chang Hyun;Park, Soo Bin;Song, Hyun Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제23권2호
    • /
    • pp.71-79
    • /
    • 2020
  • Background: The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels. Methods: A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman's method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results: The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7°±4.9° on the 2D CT images and -1.8°±4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7°±5.2° on the 2D CT images and -0.5°±4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions: The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels.

전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교 (Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull)

  • 강복희;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

  • Oh, Suseok;Kim, Ci-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권3호
    • /
    • pp.123-129
    • /
    • 2014
  • Objectives: The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. Materials and Methods: Reference horizontal plane was FH plane. Palatal angle and occlusal plane angle was evaluated with FH plane. Gonial angle (GA), palatal angle, upper occlusal plane angle (UOPA), mandibular plane angle (MPA), U1 to occlusal plane angle, U1 to FH plane angle, SNA and SNB were obtained on 2D cephalmetries and reconstructed 3D CT. The values measured eight angles in 2D lateral cephalometry and reconstructed 3D CT were evaluated by intraclass correlation coefficiency (ICC). It also was evaluated to identify 3D FH plane with high degree of concordance to 2D one by studying which one in four FH planes shows the highest degree of concordance with 2D FH plane. Results: ICCs of MPA (0.752), UOPA (0.745), SNA (0.798) and SNB (0.869) were high. On the other hand, ICCs of gonial angle (0.583), palatal angle (0.287), U1 to occlusal plane (0.404), U1 to FH plane (0.617) were low respectively. Additionally GA and MPA acquired from 2D were bigger than those on 3D in all 20 patients included in this study. Concordance between one UOPA from 2D and four UOPAs from 3D CT were evaluated by ICC values. Results showed no significant difference among four FH planes defined on 3D CT. Conclusion: FH plane that can be set on 3D CT does not have difference in concordance from FH plane on lateral cephalometry. However, it is desirable to define FH plane on 3D CT with two orbitales and one porion considering the reproduction of orbitale itself.

얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교 (Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures)

  • 정종명;김종환;홍인표;최치훈
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

Comparative study of glenoid version and inclination using two-dimensional images from computed tomography and three-dimensional reconstructed bone models

  • Choi, Chang-Hyuk;Kim, Hee-Chan;Kang, Daewon;Kim, Jun-Young
    • Clinics in Shoulder and Elbow
    • /
    • 제23권3호
    • /
    • pp.119-124
    • /
    • 2020
  • Background: This study was performed to compare glenoid version and inclination measured using two-dimensional (2D) images from computed tomography (CT) scans or three-dimensional (3D) reconstructed bone models. Methods: Thirty patients who had undergone conventional CT scans were included. Two orthopedic surgeons measured glenoid version and inclination three times on 2D images from CT scans (2D measurement), and two other orthopedic surgeons performed the same measurements using 3D reconstructed bone models (3D measurement). The 3D-reconstructed bone models were acquired and measured with Mimics and 3-Matics (Materialise). Results: Mean glenoid version and inclination in 2D measurements were -1.705° and 9.08°, respectively, while those in 3D measurements were 2.635° and 7.23°. The intra-observer reliability in 2D measurements was 0.605 and 0.698, respectively, while that in 3D measurements was 0.883 and 0.892. The inter-observer reliability in 2D measurements was 0.456 and 0.374, respectively, while that in 3D measurements was 0.853 and 0.845. Conclusions: The difference between 2D and 3D measurements is not due to differences in image data but to the use of different tools. However, more consistent results were obtained in 3D measurement. Therefore, 3D measurement can be a good alternative for measuring glenoid version and inclination.

경부 종물에서 3차원 재건 영상과 적출 조직 사진의 비교 (Comparison of 3D Reconstruction Image and Medical Photograph of Neck Tumors)

  • 유영삼
    • 대한두경부종양학회지
    • /
    • 제26권2호
    • /
    • pp.198-203
    • /
    • 2010
  • Objectives : Getting full information from axial CT images needs experiences and knowledge. Sagittal and coronal images could give more information but we have to draw 3-dimensional images in mind with above informations. With aid of 3D reconstruction softwares, CT data are converted to visible 3D images. We tried to compare medical photographs of 15 surgical specimens from neck tumors with 3D reconstructed images of same patients. Material and Methods : Fifteen patients with neck tumors treated surgically were recruited. Medical photograph of the surgical specimens were collected for comparison. 3D reconstruction of neck CT from same patients with aid of 3D-doctor software gave 3D images of neck masses. Width and height of tumors of each photos and images from the same cases were calculated and compared statistically. Visual similarities were rated between photos and 3D images. Results : No statatistical difference were found in size between medical photos and 3D images. Visual similarity score were higher between 2 groups of images. Conclusion : 3D reconstructed images of neck mass looked alike the real photographs of excised neck mass with similar calculated sizes. It could give us reliable visual information about the mass.

디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석 (Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI))

  • 정광호;조병철;강세권;김경주;배훈식;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권2호
    • /
    • pp.67-76
    • /
    • 2006
  • 본 연구에서는 환자 치료 전 셋업 확인을 위해 디지털 재구성 방사선영상(digitally reconstructed radiographs, DRR)을 참조영상으로 하여 온보드 영상 장치로부터 획득된 kV X선 영상과의 2차원 정합을 수행하였을 경우 DRR 영상의 질에 따라 환자 셋업 오차 보정의 정확도가 어떻게 달라지는가를 확인하였다. 방사선치료계획 장치로는 Pinnacle3와 Eclipse를 이용하였으며 참조 영상으로는 팬텀 및 환자를 각각 다른 슬라이스 두께로 부위별로 CT 촬영한 영상으로부터 재구성된 DRR 영상을 이용하였다. DRR 영상 및 프로파일 비교에서는 CT 슬라이스 두께가 증가함에 따라 이를 이용한 DRR 영상의 질이 저하됨을 확인할 수 있었지만 2차원 정합 결과 유사한 오차 값을 보여주어 DRR 영상의 질이 큰 영향을 미치지 않음을 확인할 수 있었다. 슬라이스 두께에 따른 2차원 정합 결과의 차이가 크지는 않지만 일반적인 환자 치료계획 및 2차원 정합을 위해 슬라이스 두께 3 mm 이하의 CT 영상 획득이 필요할 것으로 생각한다.

  • PDF

Numerical analysis of the thermal behaviors of cellular concrete

  • She, Wei;Zhao, Guotang;Yang, Guotao;Jiang, Jinyang;Cao, Xiaoyu;Du, Yi
    • Computers and Concrete
    • /
    • 제18권3호
    • /
    • pp.319-336
    • /
    • 2016
  • In this study, both two- and three-dimensional (2D and 3D) finite-volume-based models were developed to analyze the heat transfer mechanisms through the porous structures of cellular concretes under steady-state heat transfer conditions and to investigate the differences between the 2D and 3D modeling results. The 2D and 3D reconstructed pore networks were generated from the microstructural information measured by 3D images captured by X-ray computerized tomography (X-CT). The computed effective thermal conductivities based on the 2D and 3D calculations performed on the reconstructed porous structures were found to be nearly identical to those evaluated from the 2D cross-sectional images and the 3D X-CT images, respectively. In addition, the 3D computed effective thermal conductivity was found to agree better with the measured values, in comparison with the 2D reconstruction and real cross-sectional images. Finally, the thermal conductivities computed for different reconstructed porous 3D structures of cellular concretes were compared with those obtained from 2D computations performed on 2D reconstructed structures. This comparison revealed the differences between 2D and 3D image-based modeling. A correlation was thus derived between the results of the 3D and 2D models.

개인용 컴퓨터와 소프트웨어를 이용한 3차원 전산화단층영상에서의 금속 수복물에 의한 선상 오류의 제거 (The elimination of the linear artifacts by the metal restorations in the three dimensional computed tomographic images using the personal computer and software)

  • 박혁;이희철;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제33권3호
    • /
    • pp.151-159
    • /
    • 2003
  • Purpose: The purpose of this study is to evaluate the effectiveness and usefulness of newly developed personal computer-based software to eliminate the linear artifacts by the metal restorations. Materials and Methods: A 3D CT image was conventionally reconstructed using ADVANTAGE WINDOWS 2.0 3D Analysis software (GE Medical System, Milwaukee, USA) and eliminated the linear artifacts manually. Next, a 3D CT image was reconstructed using V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea) and the linear artifacts eliminated manually in the axial images by a skillful operator using a personal computer. A 3D CT image was reconstructed using V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea) and the linear artifacts were removed using a simplified algorithm program to eliminate the linear artifacts automatically in the axial images using a personal computer, abbreviating the manual editing procedure. Finally, the automatically edited reconstructed 3D images were compared to the manually edited images. Results and Conclusion: We effectively eliminated the linear artifacts automatically by this algorithm, not by the manual editing procedures, in some degree. But programs based on more complicated and accurate algorithms may lead to a nearly flawless elimination of these linear artifacts automatically.

  • PDF