• Title/Summary/Keyword: 3D numerical model

Search Result 1,536, Processing Time 0.029 seconds

A Study on the Minimization of Tie-plate Loss of Cast Resin Transformer using Surface Impedance Boundary Condition (표면 임피던스 경계조건을 이용한 몰드변압기 Tie-plate 손실 최소화에 관한 연구)

  • Hwang, Sung-Ryul;Shin, Pan Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1334-1340
    • /
    • 2017
  • In this paper, a tie-plate shape is optimized by using the numerical technique to reduce the stray load loss of the tie-plate which is a mechanical structure for assembling and supporting of the transformer core. The eddy current loss of the structure is calculated by an electromagnetic field FEM program and the results are compared with 4 different shapes of tie-plates. Since the thickness of the tie-plate is very thin, and the skin depth is very small, the number of FE elements for 3-D transformer model is too big to solve. So, the surface impedance boundary condition (SIBC) is used to reduce the system matrix size and its computing time. To verify the method a 2.5 MVA 22,900/380V distribution transformer is simulated using one objective function and three design variables with some constraints. The final optimized tie-plate has three slots of 6 mm width and 23 mm gap, and the loss is reduced by 75 %. Consequently, the proposed algorithm seems to be considerably applicable to electric machinery as well as power transformer.

HYLGS 모델을 활용한 수도권 매립지에서의 침출수-가스의 동시유동 해석에 관한 연구

  • 이광희;박용찬;성원모
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.225-231
    • /
    • 1998
  • Open dump causes groundwater and soil contamination by leachate, air pollution by LFG (Landfill Gas). In this paper, in order to improve landfill researches which have been done about reduction of high leachate level and LFG collection in the Kimpo landfill separately, the effect of simultaneous flowing of leachate and LFG has been Studied. The HYLGS (Hanyang Leachate Gas Simulator) used in this study is a 3D, 2-phase, transient FDM model which can be applied to venting trenches in a landfill. From present numerical analysis it can be concluded that all the pressures of the Kimpo landfill grid system are almost the same and their maximum value in the center grid block of the system is approximately 26 m $H_2O$ (2.52 atm), that because the pressures of venting trench layer situated in the middle of the landfill have the lowest values and equal with air pressure, the venting trenches play an important role in landfill stabilization, that the flow of gas will be more difficult as time goes by owing to the increase of LGR(Leachate and gas ratio).

  • PDF

An Efficient Triangulation Algorithm for Trimmed NURBS Surfaces (트림된 NURBS 곡면의 효율적인 삼각화 알고리즘)

  • 정재호;박준영
    • Korean Journal of Computational Design and Engineering
    • /
    • v.5 no.2
    • /
    • pp.144-154
    • /
    • 2000
  • We propose an algorithm for obtaining a triangular approximation of a trimmed NLRBS surface. Triangular approximation is used in the pre-processing step of many applications such as RP(Rapid Prototyping), NC(Numerical Control) and FEA(Finite Element Analysis), etc. The algorithm minimizes the number of triangular elements within tolerance and generates a valid triangular mesh for STL file and NC tool path generation. In the algorithm, a subdivision method is used. Since a patch is a basic element of triangular mesh creation, boundary curves of a patch are divided into line segments and the division of curves is applied for the interior of the surface. That is, boundary curves are subdivided into line segments and two end points of each line segment are propagated to the interior of the surface. For the case of a trimmed surface, triangulation is carried out using a model space information. The algorithm is superior because the number of elements can be controlled as the curvature of the surface varies and it generates the triangular mesh in a trimmed region efficiently. To verify the efficiency, the algorithm was implemented and tested for several 3D objects bounded by NURBS surfaces.

  • PDF

Flow Instability Assessment Occurring in Low Flow Rate Region According to the Change of a Centrifugal Compressor Impeller Shape (원심압축기 임펠러의 형상 변화에 따른 저유량 영역에서 발생하는 불안정 유동 평가)

  • Jo, Seong Hwi;Kim, Hong Jip;Lee, Myong Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.21-26
    • /
    • 2016
  • The objective of present study is to assess the performance of the first stage compressor in a total 3-stage 5000 HP-level turbo compressor. CFD commercial code, CFX has been used to predict three-dimensional flow characteristics inside of the impeller. Shear Stress Transport (SST) model has been used to simulate turbulent flows through Reynolds-averaged Navier-Stokes (RANS) equations. Grid dependency has been also checked to get optimal grid distribution. Numerical results have been compared with the experimental test results to elucidate performance characteristics of the present compressor. In addition, flow characteristics of the impeller only have been studied for various blade configurations. Angular offset in leading edge of the blade has been selected for the optimal blade design. Performance characteristics in region of low mass flow rate and high pressure ratio between the impeller entrance and exit have been investigated for the selection of optimal blade design. Also, flow instability such as stall phenomena has been studied and anti-stall characteristics have been checked for various blade configurations in the operational window.

A study on influence of cutting angle on the thermal characteristics in the linear heat cutting of EPS foam in case of generally sloped cutting (EPS foam 의 선형 열선절단시 일반 절단경사각의 제품 정밀도에 미치는 영향에 관한 연구)

  • 안동규;이상호;김효찬;양동열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.176-180
    • /
    • 2002
  • All types of VLM-s process include the linear heat cutting of EPS foam to generate a layer with 3D shape. The dimensional accuracy and part quality of the cut part are dependent on the thermal characteristics in the EPS foam. The thermal characteristics are determined by operating parameters such as an effective heat input and cutting angle. The objective of this study is to investigate into the influence of cutting angle on the kerfwidth and the melted length of the cut part using the numerical analysis and the experiments in generally sloped cutting with two cutting angles. In order to estimate an accurate temperature field, the transient thermal analysis using moving coordinate system, the fully conformed mesh and the heat flux model with two cutting angles is carried out. From the results of the analysis and the experiments, it has been found that the influence of the rotational angle about x-axis in which the rotational axis is normal with hotwire cutting direction is appreciably negligible in comparison with that of the rotational angle about y-axis.

  • PDF

Computational Fluid Dynamics Simulation of Flow Pattern Change in the Andong-Imha Reservoir Connecting Tunnel Due to Fish Exclusion Screens (어류 차단 스크린 설치에 따른 안동-임하호 연결터널 내 흐름변화에 대한 전산유체동역학 수치모의)

  • An, Sangdo
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.477-485
    • /
    • 2014
  • Imha Reservoir is connected to Andong Reservoir via a diversion tunnel allowing water to pass between. The diversion tunnel is equipped with screens to exclude exotic largemouth bass due to their predatory impacts on prey assemblages resulting in a degradation of species richness of local fish fauna and extinction of local fish populations in Korea. Flow pattern changes resulting from the fish screens and trash racks were investigated using a computational fluid dynamics (CFD) model. Numerical simulations showed that the decrease in the discharge capacity of the tunnel is approximately 8.6% and the headloss coefficient for fish screen at Andong intake tower was determined to be 1.5. In order not to allow the small fishes enough to pass through the wire openings enter into Imha Reservoir through tunnel, the velocity in the tunnel should be greater than 1.48 m/s which is a critical ascending velocity of the bass. This study suggests that it can keep the velocity higher enough to exclude largemouth bass when a gate opens with the condition of 1.0m difference in water stage between two reservoirs.

Prediction of the Effect of Defect Parameters on the Thermal Contrast Evolution during Flash Thermography by Finite Element Method

  • Yuan, Maodan;Wu, Hu;Tang, Ziqiao;Kim, Hak-Joon;Song, Sung-Jin;Zhang, Jianhai
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • A 3D model based on the finite element method (FEM) was built to simulate the infrared thermography (IRT) inspection process. Thermal contrast is an important parameter in IRT and was proven to be a function of defect parameters. Parametric studies were conducted on internal defects with different depths, thicknesses, and orientations. Thermal contrast evolution profiles with respect to the time of the defect and host material were obtained through numerical simulation. The thermal contrast decreased with defect depth and slightly increased with defect thickness. Different orientations of thin defects were detected with IRT, but doing so for thick defects was difficult. These thermal contrast variations with the defect depth, thickness, and orientation can help in optimizing the experimental process and interpretation of data from IRT.

Long-term simulation of wind turbine structure for distributed loading describing long-term wind loads for preliminary design

  • Ibrahimbegovic, Adnan;Boujelben, Abir
    • Coupled systems mechanics
    • /
    • v.7 no.2
    • /
    • pp.233-254
    • /
    • 2018
  • In order to reduce the dependency on fossil fuels, a policy to increase the production capacity of wind turbine is set up. This can be achieved with increasing the dimensions of offshore wind turbine blades. However, this increase in size implies serious problems of stability and durability. Considering the cost of large turbines and financial consequences of their premature failure, it is imperative to carry out numerical simulations over long periods. Here, an energy-conserving time-stepping scheme is proposed in order to ensure the satisfying computation of long-term response. The proposed scheme is implemented for three-dimensional solid based on Biot strain measures, which is used for modeling flexible blades. The simulations are performed at full spatial scale. For reliable design process, the wind loads should be represented as realistically as possible, including the fluid-structure interaction (FSI) dynamic effects on wind turbine blades. However, full-scale 3D FSI simulations for long-term wind loading remain of prohibitive computation cost. Thus, the model to quantify the wind loads proposed here is a simple, but not too simple to be representative for preliminary design studies.

Seismic behavior of steel frames with lightweight-low strength industrialized infill walls

  • Zahrai, Seyed Mehdi;Khalili, Behnam Gholipour;Mousavi, Seyed Amin
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1273-1290
    • /
    • 2015
  • JK wall is a shear wall made of lightweight EPS mortar and reinforced with a 3-D galvanized steel mesh, called JK panel, and truss-like stiffeners, called JK stiffeners. Earlier studies have shown that low strength lightweight concrete has the potential to be used in structural elements. In this study, seismic contribution of the JK infill walls surrounded by steel frames is numerically investigated. Adopting a hybrid numerical model, behavior envelop of the wall is derived from the general purpose finite element software, Abaqus. Obtained backbone would be implemented in the professional analytical software, SAP2000, in which through calibrated hysteretic parameters, cyclic behavior of the JK infill can be simulated. Through comparison with earlier experimental results, it turned out that the proposed hybrid modeling can simulate monotonic and cyclic behavior of JK walls with good accuracy. JK infills have a panel-type configuration which their dominant failure mode would be ductile in flexure. Finally technical and economical advantages of the proposed JK infills are assessed for two representative multistory buildings. It is revealed that JK infills can reduce maximum inter-story drifts as well as residual drifts at the expense of minor increase in the developed base shear.

Spectrum Sharing-Based Multi-Hop Decode-and-Forward Relay Networks under Interference Constraints: Performance Analysis and Relay Position Optimization

  • Bao, Vo Nguyen Quoc;Thanh, Tran Thien;Nguyen, Tuan Duc;Vu, Thanh Dinh
    • Journal of Communications and Networks
    • /
    • v.15 no.3
    • /
    • pp.266-275
    • /
    • 2013
  • The exact closed-form expressions for outage probability and bit error rate of spectrum sharing-based multi-hop decode-and-forward (DF) relay networks in non-identical Rayleigh fading channels are derived. We also provide the approximate closed-form expression for the system ergodic capacity. Utilizing these tractable analytical formulas, we can study the impact of key network parameters on the performance of cognitive multi-hop relay networks under interference constraints. Using a linear network model, we derive an optimum relay position scheme by numerically solving an optimization problem of balancing average signal-to-noise ratio (SNR) of each hop. The numerical results show that the optimal scheme leads to SNR performance gains of more than 1 dB. All the analytical expressions are verified by Monte-Carlo simulations confirming the advantage of multihop DF relaying networks in cognitive environments.