• 제목/요약/키워드: 3D image reconstruction

검색결과 591건 처리시간 0.028초

Stereo Calibration Using Support Vector Machine

  • Kim, Se-Hoon;Kim, Sung-Jin;Won, Sang-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.250-255
    • /
    • 2003
  • The position of a 3-dimensional(3D) point can be measured by using calibrated stereo camera. To obtain more accurate measurement ,more accurate camera calibration is required. There are many existing methods to calibrate camera. The simple linear methods are usually not accurate due to nonlinear lens distortion. The nonlinear methods are accurate more than linear method, but it increase computational cost and good initial guess is needed. The multi step methods need to know some camera parameters of used camera. Recent years, these explicit model based camera calibration work with the development of more precise camera models involving correction of lens distortion. But these explicit model based camera calibration have disadvantages. So implicit camera calibration methods have been derived. One of the popular implicit camera calibration method is to use neural network. In this paper, we propose implicit stereo camera calibration method for 3D reconstruction using support vector machine. SVM can learn the relationship between 3D coordinate and image coordinate, and it shows the robust property with the presence of noise and lens distortion, results of simulation are shown in section 4.

  • PDF

소 동물 촬영을 위한 Micro-CT의 개발 (Development of a Micro-CT System for Small Animal Imaging)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.97-102
    • /
    • 2004
  • 소 동물 촬영에 이용될 수 있는 고해상도의 x-선 cone-beam micro computed tomography (micro-CT) 시스템을 개발하였다 Micro-CT 시스템은 120${\times}$120 mm2 의 2차원 평판 x-선 감지기, micro-focus x-선 발생장치, 주사 기구부, 병렬처리 영상 재구성 시스템으로 이루어져 있다. 개발된 시스템의 성능을 평가하기 위해 대조도와 공간해상도를 측정하였다. 대조도 실험에서는 95 mGy 에서 36 CT-번호를 구별할 수 있음을 확인하였고, 공간 해상도 실험에서는 14 lp/mm 의 성능을 확인하였다. 소 동물 촬영 결과로 실험용 쥐의 대퇴부, 심장 그리고 복부 동맥 혈관을 촬영한 경상을 제시하였다. 개발된 micro-CT 시스템은 소 동물을 이용한 생명공학 분야 연구에 널리 이용될 수 있을 것으로 기대된다.

측면거리 상관함수를 이용한 수동주사 초음파 영상 프레임들로부터의 3차원 영상 재구성 (Reconstruction of 3D Ultrasound Image from Freehand Scanned Frames Using Lateral Correlation Functions)

  • 이준호;김남철;김상현
    • 한국통신학회논문지
    • /
    • 제26권8B호
    • /
    • pp.1152-1160
    • /
    • 2001
  • 본 논문에서는 수동주사로 얻은 2차원 연속 프레임으로 3차원 초음파 영상 재구성을 위한 연속 프레임의 프레임간 거리 추정 방법을 제안하였다. 수동주사로 얻은 연속 프레임은 프레임간 거리가 불균일하기 때문에 이를 그대로 3차원 영상으로 재구성하면 실제 인체 장기의 형태와 다른 영상을 얻게 된다. 제안한 알고리듬에서는 연속 프레임의 프레임간 거리를 추정하기 위하여 매 프레임의 블록별 측면거리 상관함수를 얻고, 측면거리 상관함수들이 프로브의 진행축과 초음파 센서의 배열축이 이루는 평면상에서 등방성을 가진다는 가정 하에 인접 프레임 내의 각 블록간의 프레임간 거리를 추정하였다. 인접 프레임간 추정거리는 프레임 내에서 블록단위로 추정된 프레임간 거리를 평균하여 얻었다. 실험 결과, 제안한 알고리듬의 프레임간 추정거리 곡선은 기준 진행거리 상관함수를 이용한 방법의 추정거리 곡선에 비해서 실제 프레임간 거리 곡선에 가까웠고, SNR 비교에서 제안한 방법이 기존의 방법에 비해 좋은 결과를 보였다. 그리고, 기존의 알고리듬에 비해 제안한 알고리듬으로 재구성한 3차원 영상이 원영상에 더 흡사한 것을 볼 수 있었다.

  • PDF

Digital Holographic PIV 기법의 개발과 제트유동에의 응용 (Development of Digital Holographic PIV Technique and Its Application)

  • 김석;이상준
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.123-130
    • /
    • 2005
  • A digital in-line holographic particle image velocimetry (HPIV) which can be applied to measure three-dimensional velocity fields of turbulent flows was developed. There are three different implementation methods of HPIV: traditional film-based HPIV, intermediate HPIV and digital HPIV. The traditional film-based HPIV and intermediate HPIV method is rather troublesome to do experiments and takes long calculation time, compared with the digital HPIV, Configuration of the digital in-line HPIV is simple and the data processing routine is similar to conventional 2D PIV methods. The digital HPIV velocity field measurement consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved PTV algorithm to extract the displacement of particle each placed in 3D space. The developed digital in-line HPIV system was applied to a vertical jet flow. The 3D velocity vectors measured by the digital HPIV method in the near field are in a good agreement with 2D PIV results.

저선량.고화질 CT 영상 획득을 위한 반복적 재구성 기법의 정량적 평가 : 필터보정 역투영법과의 비교 분석 (Quantitative evaluation of iterative reconstruction algorithm for high quality computed tomography image acquisition with low dose radiation : Comparison with filtered back projection algorithm)

  • 하성민;심학준;장혁재;김선규
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2013년도 하계학술대회
    • /
    • pp.274-277
    • /
    • 2013
  • CT(Computed Tomography)영상에서 선량과 화질은 중요한 요소이다. 선량은 환자에게 직접적으로 악영향을 끼치는 요소이며, 화질은 환자의 병변을 판단하는데 매우 중요하게 작용한다. 반복적 재구성 알고리즘을 이용하면 저선량 영상에서도 고화질의 영상을 얻을 수 있는지 FBP와 정량적, 정성적으로 비교하였다. 촬영 프로토콜은 관전압 80, 100, 120kVp에서 관전류를 동일하게 200mA로 촬영하여 획득하였으며, 정량적 평가를 위해 SD(Standard Deviation), SNR(Signal to Noise Ratio), MTF(Modulation Transfer Function)를 측정하여 분석하였다. 선량은 80kVp일 때 가장 낮았으며, 120kVp일 때 가장 높았다. 80kVp의 영상을 Toshiba 사(社)의 AIDR 3D(Adaptive Iterative Reduction integrated into $^{SURE}Exposure$)로 재구성하고, 120kVp의 영상에 FBP로 재구성한 다음 정량적 비교를 한 결과 AIDR 3D를 적용한 영상의 SD가 낮게 나왔으며, SNR이 높게 나타났고, MTF 곡선은 유사하게 나타났다. 그리고 FWHM(Full Width at Half Maximum) 값의 오차가 거의 없었다. 결론적으로 AIDR 3D는 저선량에서도 높은 화질을 나타냄을 확인하였다.

  • PDF

정규상호상관도를 이용한 입체 입자영상유속계 알고리즘 개발 (Development of Algorithm for Stereoscopic PIV using Normalized Cross-correlation)

  • 오정근;김유철;류민철;고원규;서정천
    • 대한조선학회논문집
    • /
    • 제44권6호
    • /
    • pp.579-589
    • /
    • 2007
  • Contrary to the conventional single-point measuring devices such as LDV, pitot-tube, hot-wire, etc., it would be possible to measure instantaneously 3-D flow fields with a stereoscopic PIV system. In this paper, we present an analysis algorithm for a stereoscopic PIV system using the normalized cross-correlation (NCC) and a 3-D calibration based reconstruction method. The evaluation method based on NCC is one of the most accurate correlation-based methods. We validated the developed algorithm through a benchmarking comparison with 3-D artificial SPIV images and calibration target images.

3D 영상 재구성을 통한 복부대동맥과 상장간막동맥과의 각도에 관한 연구 (A Study on the Angle between the Abdominal Aorta and the Superior Mesenteric Artery by 3D Image Reconstruction)

  • 김영근;최성관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권1호
    • /
    • pp.63-70
    • /
    • 2003
  • 상장간맥동맥 증후군은 일반적인 검사에서 매우 탐지가 어려운 십이지장 만성폐색의 원인으로 대두되고 있다. 그러므로, 십이지장의 횡행부가 상장간막동맥과 복부대동 사이를 지나가기 때문에 복부대동맥과 상장간맥동맥 사이의 각도가 좁아져 십이지장 폐색의 원인을 야기시킨다. 이 각도의 측정은 일반혈관촬영으로는 복잡하고, 종종 부정확한 결과를 초래한다. 또한 한국인을 기준으로 각도 측정에 관한 시도 및 자료가 없는 실정이다. 따라서 본 연구자는 3차원 영상재구성을 위하여 범용컴퓨터에서 실행 가능한 Rapidia S/W를 이용함으로써 복부대동맥으로부터 상장간막동맥기시부의 각도를 측정하였는데, 상장간막동맥증후군이 없는 일반 환자를 대상으로 복부전산화단층촬영의 3차원영상을 이용하였다. 이 실험의 결과 상장간막동맥과 복부대동맥의 평균각도는 $50.05{\pm}15.87^{\circ}$이고 남자의 평균각도는 $53.64{\pm}16.57^{\circ}$이고 여자는 $46.46{\pm}14.98^{\circ}$로 남자의 각도가 약간 더 크게 나타났다. 이러한 연구를 통하여 얻은 각도가 상장간막동맥 증후군의 진단하는데 매우 중요한 지표가 될 것으로 사료된다.

  • PDF

Automatic Building Reconstruction with Satellite Images and Digital Maps

  • Lee, Dong-Cheon;Yom, Jae-Hong;Shin, Sung-Woong;Oh, Jae-Hong;Park, Ki-Surk
    • ETRI Journal
    • /
    • 제33권4호
    • /
    • pp.537-546
    • /
    • 2011
  • This paper introduces an automated method for building height recovery through the integration of high-resolution satellite images and digital vector maps. A cross-correlation matching method along the vertical line locus on the Ikonos images was deployed to recover building heights. The rational function models composed of rational polynomial coefficients were utilized to create a stereopair of the epipolar resampled Ikonos images. Building footprints from the digital maps were used for locating the vertical guideline along the building edges. The digital terrain model (DTM) was generated from the contour layer in the digital maps. The terrain height derived from the DTM at each foot of the buildings was used as the starting location for image matching. At a preset incremental value of height along the vertical guidelines derived from vertical line loci, an evaluation process that is based on the cross-correlation matching of the images was carried out to test if the top of the building has reached where maximum correlation occurs. The accuracy of the reconstructed buildings was evaluated by the comparison with manually digitized 3D building data derived from aerial photographs.

VVC 인트라 부호화기술을 이용한 라이트필드 영상 부호화 (Light Field Image Compression using Versatile Video Coding Intra Prediction)

  • ;;이재린;전병우
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2019년도 하계학술대회
    • /
    • pp.222-224
    • /
    • 2019
  • Light Field (LF) camera captures not only the light intensity but also the light direction coming to camera. While the rich information captured by LF camera enables many interesting applications such as digital refocusing, viewpoint changing, and 3D reconstruction, but it also requires powerful coding tools to reduce its large volume of data. In this paper, we investigate using the intra prediction scheme of the versatile video coding (VVC), which is the most recent video coding technology currently under developing, to compress the LF image. The Intra Block Copy (IBC) technique in VVC is exploited considering special LF image structure. The experimental result shows that VVC intra predict ion outperforms the H.265/HEVC intra coding technique in encoding LF data irrespective of using the IBC mode or not.

  • PDF

PIV 측정 및 수치해석을 이용한 구강암 수술에 따른 기도 형상 내 유동 특성 (Flow Characteristics in a Human Airway model for Oral Cancer Surgery by PIV Experiment and Numerical Simulation)

  • 홍현지;안세현;서희림;송재민;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.115-122
    • /
    • 2021
  • Oral cancer surgery typically consists of resection of lesion, neck dissection and reconstruction, and it has an impact on the position of hyoid bone. Therefore, morphological change of airway can occur since the geometric parameter of airway is correlated with the hyoid bone. Airflow is affected by geometry of the airway. In this study, flow characteristics were compared between pre- and post-surgery models by both particle image velocimetry (PIV) and numerical simulation. 3D model of upper airway was reconstructed based on CT data. Velocity is accelerated by the reduced channel area, and vortex and recirculation region are observed in pre- and post-surgery models. For the post-surgery model, high pressure distribution is developed by significantly decreased hydraulic diameter, and the longitudinal flow stream is also interrupted.