• Title/Summary/Keyword: 3D experiments

Search Result 2,924, Processing Time 0.038 seconds

Comparisons of 2-D and 3-D IVR experiments for oxide layer in the three-layer configuration

  • Bae, Ji-Won;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2499-2510
    • /
    • 2020
  • We performed 3-D (3-dimensional) IVR (In-Vessel Retention) natural convection experiments simulating the oxide layer in the three-layer configuration, varying the aspect ratio (H/R). Mass transfer experiment was conducted based on the analogy to achieve high RaH's of 1.99 × 1012-6.90 × 1013 with compact facilities. Comparisons with 2-D (2-dimensional) experiments revealed different local heat transfer characteristics on upper and lower boundaries of the oxide layer depending on the H/R. For the 3-D shallow oxide layer, the multi-cell flow patterns appeared and the number of cells was considerably increased with the H/R decreases, which differs with the 2-D experiments that the number of cells was independent on H/R. Thus, the enhancement of the downward heat transfer and the mitigation of the focusing effect were more noticeable in the 3-D experiments.

Effect of the Centrifugation Temperature on Cortisol, $25OHD_3$ Values After Extraction (Cortisol, $25OHD_3$ 추출 후 원심 분리시 온도가 검사결과에 미치는 영향)

  • Kim, Whe-Jung;Cheon, Jun-Hong;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.143-146
    • /
    • 2009
  • Purpose: We use the centrifugation of refrigeration state in separation of blood serum, Anti-ds-DNA, Vitamin $B_{12}$/Folate and GAD-Ab assay. However, Cortisol urine and 25-Hydroxyvitamin $D_3$ ($25OHD_3$) are conducted centrifuge at room temperature. This is troublesome that change centrifugation temperature into room temperature due to using of most assays at cold temperature. Therefore when using centrifuge after extraction of Cortisol urine and $25OHD_3$, we conducted researches on effect of the centrifugation temperature in assay results. Materials and Methods: In Cortisol urine, add dichloromethane 1.0 mL in urine $500\;{\mu}L$, mix for 15 minutes, and then centrifuge for 8 minutes at 2600rpm. In $25OHD_3$ add acetonitrile 0.5 mL in serum $200\;{\mu}L$, and then centrifuge for 8 minutes at 2600rpm. Those experiments were conducted centrifuge at room temperature and $4^{\circ}C$. And experiments conducted immediately after centrifugation at $4^{\circ}C$ and standing for 20 minutes after centrifugation $4^{\circ}C$. Results: In Cortisol urine, room temperature result in 1.93, 2.18, 2.43, 9.45, 14.2 (${\mu}g/dL$). Experiments of performing immediately after centrifuge at $4^{\circ}C$ result in 1.8, 2.0, 2.3, 8.1, 13.7 (${\mu}g/dL$). Experiments of performing after 20 minutes result in 2.1, 2.1, 2.7, 9.95, 14.35 (${\mu}g/dL$). On the other hand, the $25OHD_3$ tests conducted at room temperature result in 7.13, 26.6, 35.8, 48.2, 74.8 (ng/dL). Experiments were conducted immediately by pipetting after $4^{\circ}C$ centrifugation result in 7.53, 30.9, 40.3, 61.5, 89.1 (ng/dL) as results are higher than experiments at room temperature. The experiments that conducted centrifuge at $4^{\circ}C$ and then left at room temperature for 20 minutes result in 7.40, 32.4, 41.3, 51.6, 85.6 (ng/dL). Conclusions: Experiments were conducted by using centrifuge at $4^{\circ}C$ are higher or lower than room temperature. The differences between results of standing for 20 minutes after centrifuge at $4^{\circ}C$ and those of centrifuge at room temperature are less than conducting immediately. It is concerned that experiments conducted immediately after centrifuge at $4^{\circ}C$ are incorrect, because tubes become dim due to temperature differences between $4^{\circ}C$ and room temperature. Therefore, it is desirable to centrifuge at room temperature as manual and we should pipet promptly without stopping.

  • PDF

Application of multi dimensional NMR experiments to VBS RNAs of Yeast Saccaromyces cerevisiae virus

  • Chaejoon Cheong;Cheong, Hae-Kap;Yoo, Jun-Seok
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.5 no.1
    • /
    • pp.29-36
    • /
    • 2001
  • The structures of two VBS (viral binding site) RNAs, SL1 and SL2, of Yeast Saccharomyces cerevisiae vims have been studied by 2D and 3D NMR experiments. VBSs play a crucial role in viral particle binding to the plus strand and packaging of the RNA. The secondary structures of the two VBS RNAs share a common feature of the stem-internal loop-stem-hairpin loop structure although the size of the internal loops of SL1 and SL2 differs. 2D experiments were sufficient for fill assignments of SL1. However, isotope labeling of the sample and multidimensional experiments were required for 28-nucleotide-long SL2 due to the spectral overlap. Several 3D HCCH experiments have accomplished full assignment of SL2 RNA.

  • PDF

Visual depth perception of three dimensinal images and two dimensional images (입체영상과 평면영상의 심도 인지량에 관한 연구)

  • Cho, Am
    • Journal of the Ergonomics Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.11-22
    • /
    • 1991
  • This paper aims to examine experimentally the difference of subjectively measured degree of depth between two dimensional (2D) and three dimensional (3D) images. For this paper, two experiments were conducted; in the first experiment, the subjects were asked to estimate the distance between two objects presented with different depths, while in the second experiment, the subjects' role was to rank three objects in the order of distance from the screen. In both experiments, the objects were presented either in 2D or 3D images. The results of the experiments show that the use of 3D images can induce more accurate and more stable estimates of distance than the use of 2D images. However, it is also noted that the absolute degree of depth is not the unique criteria utilized by the subjects for the distinction of small differences of depth.

  • PDF

Two- and three-dimensional experiments for oxide pool in in-vessel retention of core melts

  • Kim, Su-Hyeon;Park, Hae-Kyun;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1405-1413
    • /
    • 2017
  • To investigate the heat loads imposed on a reactor vessel through the natural convection of core melts in severe accidents, mass transfer experiments were performed based on the heat transfer/mass transfer analogy, using two- (2-D) and three-dimensional (3-D) facilities of various heights. The modified Rayleigh numbers ranged from $10^{12}$ to $10^{15}$, with a fixed Prandtl number of 2,014. The measured Nusselt numbers showed a trend similar to those of existing studies, but the absolute values showed discrepancies owing to the high Prandtl number of this system. The measured angle-dependent Nusselt numbers were analyzed for 2-D and 3-D geometries, and a multiplier was developed that enables the extrapolation of 2-D data into 3-D data. The definition of $Ra^{\prime}_H$ was specified for 2-D geometries, so that results could be extrapolated for 3-D geometries; also, heat transfer correlations were developed.

A Comparative Analysis between 2D and 3D Modeling in the Piercing Process of Lead Frame and Experimental Study (리드프레임 피어싱 공정의 2D와 3D 모델링 비교해석 및 실험적 연구)

  • Bang, H.J.;Han, S.S.;Han, C.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.288-291
    • /
    • 2006
  • Piercing or blanking process is widely used to manufacture most of lead frame parts, but it is difficult to analyze the real process by the actual shape through progressive dies. In this paper several stages in progressive punching are modeled by 2D and 3D configurations using $DEFORM^{TM}$ 2D/ 3D code. During the progressive stage some state variables and deformed configurations are analyzed in each model. There are three stages in the process, the deformations at each stage are cumulative. The advantages and disadvantages of these two type modeling are discussed and analyzed. The experiments are performed as a working material copper alloy through manufactured die. Computed results in load by two types are compared to experiments.

  • PDF

Resolution improvement of 3D images in plane-based computational integral imaging reconstruction technique (평면기반 컴퓨터 집적 영상 재생 방법에서 3차원 영상의 해상도 개선)

  • Shin, Dong-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1944-1949
    • /
    • 2007
  • In this paper, a new plane-based computational reconstruction technique for three-dimensional (3D) objects in 3D internal imaging based on a lens model is proposed. For the proposed technique, computational experiments have been carried out for various test images. Resolution of the reconstructed images is analyzed and compared with that obtained by the conventional technique. From experiments, it is shown that the resolution of a 3-D reconstructed image was improved by using the proposed technique.

A 3D Foot Scanner Using Mirrors and Single Camera (거울 및 단일 카메라를 이용한 3차원 발 스캐너)

  • Chung, Seong-Youb;Park, Sang-Kun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

Flow Stress Determination of Johnson-Cook Model of Ti-6Al-4V Material using 3D Printing Technique (3D 프린팅으로 제작한 Ti-6Al-4V 재료의 Johnson-Cook 모델의 유동 응력 결정)

  • Park, Dae-Gyoun;Kim, Tae-Ho;Jeon, Eon-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.64-69
    • /
    • 2018
  • This paper investigates the compressive deformation behavior of direct metal tooling (DMT), processing titanium alloy (Ti-6Al-4V) parts under high strain loading conditions. Split Hopkinson Pressure Bar (SHPB) experiments were performed to determine the flow stress and the coefficients of the Johnson-Cook model. This model is described as a function of strain, strain rate, and temperature. SHPB experiments were performed to characterize the deformation behavior of specimens made with 3D printers, using Ti-6Al-4V material under high temperature and dynamic loading.

Administration of vitamin D3 by injection or drinking water alters serum 25-hydroxycholecalciferol concentrations of nursery pigs

  • Jang, Young Dal;Ma, Jingyun;Lu, Ning;Lim, Jina;Monegue, H. James;Stuart, Robert L.;Lindemann, Merlin D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.2
    • /
    • pp.278-286
    • /
    • 2018
  • Objective: Two experiments were conducted to evaluate vitamin $D_3$ administration to nursery pigs by injection or in drinking water on serum 25-hydroxycholecalciferol ($25-OHD_3$) concentrations. Methods: At weaning, 51 pigs (27 and 24 pigs in experiments 1 and 2, respectively) were allotted to vitamin $D_3$ treatments. Treatments in experiment 1 were: i) control (CON), no vitamin administration beyond that in the diet, ii) intramuscular (IM) injection of 40,000 IU of vitamin $D_3$ at weaning, and iii) water administration, 5,493 IU of vitamin $D_3/L$ drinking water for 14 d post-weaning. Treatments in experiment 2 were: i) control (CON), no vitamin administration, and ii) water administration, 92 IU of $d-{\alpha}-tocopherol$ and 5,493 IU of vitamin $D_3/L$ drinking water for 28 d post-weaning. The lightest 2 pigs within each pen were IM injected with an additional 1,000 IU of $d-{\alpha}-tocopherol$, 100,000 IU of retinyl palmitate, and 100,000 IU of vitamin $D_3$. Results: In both experiments, serum $25-OHD_3$ was changed after vitamin $D_3$ administration (p<0.05). In experiment 1, injection and water groups had greater values than CON group through d 35 and 21 post-administration, respectively (p<0.05). In experiment 2, serum values peaked at d 3 post-administration in the injection groups regardless of water treatments (p<0.05) whereas CON and water-only groups had peaks at d 14 and 28 post-administration, respectively (p<0.05). Even though the injection groups had greater serum $25-OHD_3$ concentrations than the non-injection groups through d 7 post-administration regardless of water treatments (p<0.05), the water-only group had greater values than the injection-only group from d 21 post-administration onward (p<0.05). Conclusion: Serum $25-OHD_3$ concentrations in pigs increased either by vitamin $D_3$ injection or drinking water administration. Although a single vitamin $D_3$ injection enhanced serum $25-OHD_3$ concentrations greater than water administration in the initial period post-administration, a continuous supply of vitamin $D_3$ via drinking water could maintain higher serum values than the single injection.