• Title/Summary/Keyword: 3D direct measurement

Search Result 142, Processing Time 0.028 seconds

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

A System for Measuring 3D Human Bodies Using the Multiple 2D Images (다중 2D 영상을 이용한 3D 인체 계측 시스템)

  • 김창우;최창석;김효숙;강인애;전준현
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.5
    • /
    • pp.1-12
    • /
    • 2003
  • This paper proposes a system for measuring the 3D human bodies using the multiple 2D images. The system establishes the multiple image input circumstance from the digital camera for image measurement. The algorithm considering perspective projection leads us to estimate the 3D human bodies from the multiple 2D images such as frontal. side and rear views. The results of the image measurement is compared those of the direct measurement and the 3D scanner for the total 40 items (12 heights, 15 widths and 13 depths). Three persons measure the 40 items using the three measurement methods. In comparison of the results obtained among the measurement methods and the persons, the results between the image measurement and the 3D scanner are very similar. However, the errors for the direct measurement are relatively larger than those between the image measurement and the 3D scanner. For example, the maximum errors between the image measurement and the 3D scanner are 0.41cm in height, 0.39cm in width and 0.95cm in depth. The errors are acceptable in body measurement. Performance of the image measurement is superior to the direct. because the algorithm estimates the 3D positions using the perspective projection. In above comparison, the image measurement is expected as a new method for measuring the 3D body, since it has the various advantages of the direct measurement and 3D scanner in performance for measurement as well as in the devices, cost, Portability and man power.

Proposal of Nail Tip Size by Measuring Nail Size of Korean Women in Their 20s -Focusing on Size Comparison Through Direct Measurement and 3D Scanner Measurement- (20대 국내여성의 손톱 사이즈 측정을 통한 네일 팁 사이즈 제안 -직접측정법과 3D 스캐너측정법을 통한 사이즈 비교를 중심으로-)

  • Lee, Eunsil;Kim, Eunsil
    • Journal of Fashion Business
    • /
    • v.24 no.1
    • /
    • pp.102-116
    • /
    • 2020
  • After its introduction in Korea, nail art is becoming active, especially among women in their 20s and 30s who are interested in fashion and beauty. Although self-nail tips are available online in various designs for each brand that is currently on the market, these designs and sizes of self-nail tips on the market are different for each age group. Since the design or size is not suggested for the different situations, there are difficulties in purchasing products that match the shape and size of nails of consumers. In this study, frequency analysis was performed using 'SPSS statistics 21.0 for windows program' to analyze data obtained by direct measurement method and 3D scanner measurement method for Korean women in their 20s. For comparative analysis between direct and 3D scanner measurements, a corresponding sample, 'T-test', was performed. As a result, we proposed the standardization of nail tip size after comparative analysis between direct measurement and 3D scanner measurement. Previous studies have been proceeding with direct measurement method. However, this study introduced a 3D scanner measurement method in the nail field and attempted the standardization of nail size by age group of Korean women. Importantly, this sutdy suggests standardization of nail tip size among missing body sizes.

Analysis of Difference between Direct Measurement and 3-D Automatic Measurement According to Classification of Side Figure of Elderly Women (고령 여성의 측면체형 분류에 따른 직접측정치와 3차원 자동측정치간의 차이 분석)

  • Chung, Juwon;Nam, Yun-Ja;Park, Jinhee
    • Fashion & Textile Research Journal
    • /
    • v.21 no.5
    • /
    • pp.627-639
    • /
    • 2019
  • This study analyzes differences between the results of 3D direct measurements and automated measurements for Korean elderly females according to age groups, side somatotype, and BMI groups. This study compares the measurement differences of the direct and the 3D automated measurements for women between the ages of 70 to 85, according to age group, BMI group, and side somatotype. A comparison of the results of the direct measurement and the 3D automated measurements for elderly women show that a meaningful discrepancy exists for 29 items out of 33 items. Furthermore, the results of comparing the average error tolerance recommended by ISO20685 shows that 30 items out of 33 items exceeded ISO recommendations. The results of the automated measurement program shows a higher degree of accuracy for straight postures; however, this unsuitable for postures of elderly women with a changed somatotype. The analysis results of the measurement difference indicate the suitability of the automatic measurement programs is found to be high for stood postures, while problems seem to exist on several items along with an automated program is not appropriately used due to posture and part of body changes for elderly women. Therefore, it is recommended to develop an algorithm, that reflects the body changes of elderly women first and then upgrade the automated program equipped with a measurement size method. It is hoped that the study results can be utilized as base data for improving the automated measurement program.

Design of Brassiere Pattern for Big Size Breast Women -Based on 3D Breast Scanning Data- (유방이 큰 여성을 위한 브래지어 패턴 설계 -3차원 유방 형상 자료를 중심으로-)

  • Han, Chohee;Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.2
    • /
    • pp.204-214
    • /
    • 2019
  • A CAD program has recently been introduced that can be directly developed into a three-dimensional human body shape and made into a pattern. It is possible to fabricate a bra that reflects the volume and surface area of the breast; however, it still needs to be verified. This study investigates the average size and shape of 20 big-breasted women and designs a brassiere pattern for women with large breasts using a 3D Flattening function of OptiTex PDS v15.6. In addition, the study verifies the reliability of the proposed method compared to a conventional brassiere pattern. The study results are as follows. First, the three dimensional measurement values were smaller than the direct measurement dimensions when the three dimension measurement dimensions of the subjects were compared with the direct measurement dimensions, the replica measurement dimensions and the three dimensional measurement dimensions. Second, the 3D flattening pattern reflects the actual shape, length, and area of the actual breast when comparing a brassiere pattern using a 3D shape and pattern reflecting the direct measurement.

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Development of a 3D Semi-Automatic Measurement Protocol for Hand Anthropometric Measurement (손 치수 측정을 위한 3차원 반자동 측정 방법 개발)

  • Lee, Won-Sup;Yoon, Sung-Hye;You, Hee-Cheon
    • IE interfaces
    • /
    • v.24 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Measurement protocols for hand anthropometry have been studied for ergonomic product design. The present study developed a 3D semi-automatic measurement protocol (3D-SAMP) which semi-automatically measures various hand dimensions using a 3D scanner. The 3D-SAMP was compared with the conventional direct measurement method (DMM) to examine its effectiveness. The 3D-SAMP consists of (1) fabricating a plaster cast of the hand, (2) placing landmarks on the plaster hand, (3) scanning the plaster hand with a 3D scanner, (4) identifying automatically the positions of the landmarks on the digital hand, and (5) extracting automatically hand anthropometric measurements (lengths, widths, thicknesses, and circumferences). An evaluation experiment conducted in the study found the 3D-SAMP preferred to the DMM in terms of reliability (the number of dimensions exceeding the variability criteria SD=2 mm and CV=5% : 3D-SAMP =2 and DMM=24) and ease of measurement (3D-SAMP=5.2 and DMM=4.3 out of 7). The 3D-SAMP can be applied to ergonomic design of a hand-held product.

A Study on a Measurement Method for 2D Anthropometry using Digital Camera (디지털 카메라를 이용한 2D 인체계측법 연구)

  • 손희정;김효숙;최창석;손희순;김창우
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.1
    • /
    • pp.11-19
    • /
    • 2003
  • This study suggests the new 2D anthropometric method using digital camera. It is used MK2001 program that can convert 2D measurements to 3D measurements. To improve that it is measured 100 college students with direct and indirect anthropometric method. The measurements were processed by the SPSS ver10 Statistical Package. The average, standard deviation, and t-test were calculated for each category. Most measurements by 2D measurements are higher than direct measurements but degree. The difference between direct and indirect measurements is less than 2cm. In the results of t-test, height measurements including other 16 measurements which is easy to measure have no meaningful difference within 1cm. The depth measurements are most high difference. The result of each measurement proves that MK2001 program (2D anthropometry method using digital camera) is available for measuring the human body.

  • PDF

Development of the system for error evaluation in coordinate measuring machines (3차원 좌표 특정기의 오차 평가 시스템 개발)

  • ;M.Burdekin;G.Peggs
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.116-120
    • /
    • 1991
  • Technique of length measurement error is widely used in the accuracy assessment of CMMS(Coordinate measuring machines) and machine tools, as it is simple and direct measurement within the working volume of a machine. In this paper, a new method is proposed for the evaluation of the length measurement error in relation to the volumetric accuracy. lD, 2D, and 3D measuring lines are considered for recpective length measurement error: 1D, 2D, and 3D length measurement uncertainties are evaluated from volumetric accuracy. The relationship between the volumetric accuracy md length measurement error to is discussed. PC based system for length measurement error evaluation and simulation is developed.

  • PDF

Three-Dimensional Measurements of the Specular Components by Using Direct Phase-Measuring Transmission Deflectometry

  • Na, Silin;Shin, Sanghoon;Kim, Doocheol;Yu, Younghun
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1275-1280
    • /
    • 2018
  • We demonstrated transmission direct phase-measuring deflectometry (DPMD) with a specular phase object having discontinuous surfaces by using two displays and a two-dimensional array detector for display and by recording the distorted fringe patterns. Three-dimensional (3D) information was obtained by calculating the height map directly from the phase information. We developed a mathematical model of the phase-height relationship in transmission DPMD. Unlike normal transmission deflectometry, this method supports height measurement directly from the phase. Compared with other 3D measurement techniques such as interferometry, this method has the advantages of being inexpensive and easy to implement.