• 제목/요약/키워드: 3D deviation

검색결과 717건 처리시간 0.026초

도재 수리 시스템의 전단결합강도에 관한 연구 (Shear Bond Strength of Porcelain Repair Systems)

  • 우수;신수연;조인호
    • 구강회복응용과학지
    • /
    • 제22권3호
    • /
    • pp.211-220
    • /
    • 2006
  • Need of porcelain-repair system is largely demanding as dental porcelain restorations are increased in clinical dentistry. This study investigated shear bond strength of commercial porcelain-repair systems on dental porcelain and their reliability. Experimental groups were as follows; Group A Super Bond C&B, Group B Porcelain repair kit, Group C Ceramic repair, and Group D Spectrum system as a control. Porcelain disks were fired and embedded in epoxy resin. Porcelain surface were ground using 220 grit SiC disk, then cleaned in ultrasonic bath. Then porcelain specimens were treated with each repair system. A clear polystyrene cylinder 3.5 mm in internal diameter was filled with composite resin. Then the resin cylinder was polymerized with a visible light curing unit. Thirty one specimens at each group were prepared and stored at $37^{\circ}C$ distilled water for 48 h. Specimens were tested in an Instron testing machine according to ISO TR 11405. Mean shear bond strength and standard deviation of each group was $15.7{\pm}4.1MPa$ (Group A), $12.8{\pm}4.9MPa$ (Group B), $7.2{\pm}3.0MPa$ (Group C) and $9.6{\pm}2.2MPa$ (Group D). ANOVA and Tukey HSD post-hoc test showed that there were significant differences between groups (p<0.05). Data of bond strength were analyzed with two-parameter Weibull distribution. Confidence interval of Weibull modulus (m-parameter) at 95% of Group A (3.5-6.3) and Group D (3.6-6.0) were significantly higher than Group B (2.2-3.7) and Group C (2.0-3.4). There was little correlation between mean shear bond strength and Weibull modulus. Results indicated that acid-etching of porcelain surface increased porcelain-resin shear bonding strength.

3D 측정 기기를 이용한 얼굴의 부피 정량법 연구 (A Quantitative Method for Human Face Volume Using 3D Optical Measurement)

  • 박신영;남개원;김승훈;이해광;안성연;문성준;김한곤
    • 대한화장품학회지
    • /
    • 제34권4호
    • /
    • pp.333-338
    • /
    • 2008
  • PRIMOS $body^{(R)}$ 기기를 이용한 얼굴부피 평가법 개발에 관한 연구를 진행하였다. 평가법의 신뢰성을 확인하고자 세 명의 시험자가 마네킹과 사람을 대상으로 얼굴 부피를 측정하였다. 마네킹의 얼굴에 여러 가지 부피의 찰흙을 붙이고, 기기로 얼굴을 측정하였는데, 실제 찰흙의 부피와 측정값 사이에 높은 상관성($R^2=0.99$)이 있는 것으로 나타났다.% RSD와 Gage R&R 분석으로 기기의 정확성, 반복성, 재현성을 확인한 결과 신뢰성이 있는 결과를 얻었다. 이와 같은 평가법을 얼굴 붓기 감소에 영향을 주는 화장품의 효능을 평가하는데 적용하였다. 10명의 건강한 여성을 대상으로 화장품 사용 전후 얼굴의 부피를 측정한 결과, 얼굴의 부피가 감소하는 것으로 나타났다. 이와 같은 결과를 통해 PRIMOS $body^{(R)}$를 이용한 얼굴 부피 평가법은 인체평가에 유용하게 사용될 수 있을 것으로 보인다.

Twin Spray Characteristics Between Two Impinging F-O-O-F Type Injectors

  • Kang, Shin-Jae;Lee, Eun-Sang;Kwon, Ki-Chul;Oh, Je-Ha;Yu, Myoung-Jong
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.732-742
    • /
    • 2002
  • This paper presents twin spray characteristics of two impinging F-O-O-F type injectors in which fuel and oxidizer impinge on each other to atomize under the various conditions. The droplet size and velocity in the impinging spray flow field were measured using PDPA. The droplet size and velocity were investigated at the mixture ratios of 1.5, 2.0, 2.47 and 3.0 for four injectors in which two single F-O-O-F injectors were arranged at the intervals of 20.8, 31.2, 41.6 and 62.4mm respectively. In general, the arithmetic mean diameter, SMD and standard deviation of droplet size in the interaction area (X=0 and Y=0mm) were smaller, while the axial velocity in the interaction area was slightly higher. An empirical correlation is obtained for the (D$\_$10/)$\_$D//(D$\_$10/)$\_$c/ value under the assumptions of two identical droplets and these with different size and velocity. The droplets with low Weber numbers below 40 have possibility to coalesce, while those over 40 tend to disintegrate after impingement in the interaction area.

L-band EDFA 에서의 온도에 따른 이득 변화와 가변 감쇄기를 이용한 온도 보상 (A compensation method for a temperature-dependent gain tilt in L-band EDFA using a voltage-controlled attenuator)

  • 이원경;정희상;주무정
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.12-16
    • /
    • 2003
  • $0^{\circ}C$에서 5$0^{\circ}C$까지 온도를 변화시켜 가며 100 GHz의 채널 간격으로 L-band 40채널을 운용했을 때, 온도에 따른 L-band EDFA의 출력 스펙트럼 변화와 이득 변동폭을 측정하였다. 이득 포화 영역에서의 이득의 변화로 인한 출력 스펙트럼의 변화는 온도에 따른 출력 스펙트럼의 변화와 상반되는 점을 이용하여 1단과 2단 사이에 삽입한 가변 감쇄기를 조절하여 온도에 따른 이득 변동을 보상하였다. 그 결과, $0^{\circ}C$에서 최대 3 dB까지 차이를 보이던 이득 변동 폭은 가변 감쇄기를 이용한 온도 보상으로 1 dB 이내로 줄어듦을 볼 수 있었다.

초등학교 교실의 C50 실태 평가 (Evaluation of C50 in Elementary School Classrooms)

  • 이성복;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.888-892
    • /
    • 2014
  • This paper evaluates $C_{50}$ in elementary school classrooms and considers utilization of $C_{50}$ as an assessment indicator of acoustic performance. $C_{50}$ is early-to-late arriving sound ratio, recent study reported that $C_{50}$ is more appropriate as a measure of clarity and speech intelligibility than D50 because it is linearly related to subjective responses. The average of $C_{50}$ in elementary school classrooms appeared to be about +2 dB ~ +3 dB throughout 500 Hz ~ 4 kHz. However, absolute evaluation is difficult because there is no suitable reference or standard yet. As deviation of $C_{50}$ according to location is larger than reverberation time, it is expected that $C_{50}$ will be more sensitive when someone assesses acoustic performance of classrooms. Correlation between $C_{50}$ and reverberation time is very high. From logarithmic regression equation, we can estimate appropriate range of $C_{50}$ in elementary school classrooms indirectly, using standard of reverberation time in ANSI.

  • PDF

인체 모형을 이용한 다중 검출기 컴퓨터단층촬영기기의 다양한 자동노출제어 시스템에 대한 연구 (A Study on Various Automatic Exposure Control System in Multi-Detector Computed Tomography by Using Human Phantom)

  • 김영옥;성열훈
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1714-1720
    • /
    • 2012
  • 다중 검출기 컴퓨터단층촬영(multi-detector computed tomography; MDCT) 장비에서 이용되는 다양한 자동노출제어(automatic exposure control; AEC) 시스템에 대한 선량 감소 정도와 영상의 품질을 비교 평가하였다. 연구에 이용한 AEC 시스템은 General Electric(GE)사의 Auto-mA 3D, Philips사의 DoseRight, 그리고 Siemens사의 Care Dose 4D를 이용하였다. 모든 실험에서 X-선 노출 조건을 가능한 한 동일하게 하였다. 다양한 AEC 시스템에서 선량 감소 평가는 인체 모형을 이용하여 고정관류기법과 비교하여 평가하였다. 또한 영상 품질은 CT 계수(number)의 표준 편차를 이용하여 영상의 잡음을 측정하였다. 그 결과 AEC 시스템을 적용할 때 Auto-mA 3D는 35.3%, DoseRight는 58.2%, Care Dose 4D는 48.6%의 최대 선량감소가 있었으며, 영상품질에서는 Care Dose 4D의 강함/약함 (Strong/Weak)의 조합에서 유의한 차이가 없었다(P=0.269). 이런 다양한 AEC 시스템의 적용은 고품질의 영상을 유지하면서 선량을 감소하는데 매우 유용 할 것이라고 사료된다.

액체생검용 Lab-on-a-Disc의 평탄도 향상을 위한 최적화 (Design Optimization to achieve an enhanced flatness of a Lab-on-a-Disc for liquid biopsy)

  • 홍석관;이정원;황택용;이성훈;김경태;강태곤;황철진
    • Design & Manufacturing
    • /
    • 제17권1호
    • /
    • pp.20-26
    • /
    • 2023
  • Lab-on-a-disc is a circular disc shape of cartridge that can be used for blood-based liquid biopsy to diagnose an early stage of cancer. Currently, liquid biopsies are regarded as a time-consuming process, and require sophisticated skills to precisely separate cell-free DNA (cfDNA) and circulating tumor cells (CTCs) floating in the bloodstream for accurate diagnosis. However, by applying the lab-on-a-disc to liquid biopsy, the entire process can be operated automatically. To do so, the lab-on-a-disc should be designed to prevent blood leakage during the centrifugation, transport, and dilution of blood inside the lab-on-a-disc in the process of liquid biopsy. In this study, the main components of lab-on-a-disc for liquid biopsy are fabricated by injection molding for mass production, and ultrasonic welding is employed to ensure the bonding strength between the components. To guarantee accurate ultrasonic welding, the flatness of the components is optimized numerically by using the response surface methodology with four main injection molding processing parameters, including the mold & resin temperatures, the injection speed, and the packing pressure. The 27 times finite element analyses using Moldflow® reveal that the injection time and the packing pressure are the critical factors affecting the flatness of the components with an optimal set of values for all four processing parameters. To further improve the flatness of the lab-on-a-disc components for stable mass production, a quarter-disc shape of lab-on-a-disc with a radius of 75 mm is used instead of a full circular shape of the disc, and this significantly decreases the standard deviation of flatness to 30% due to the reduced overall length of the injection molded components by one-half. Moreover, it is also beneficial to use a quarter disc shape to manage the deviation of flatness under 3 sigma limits.

  • PDF

안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이 (Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography)

  • 김왕식;이기헌;황현식
    • 대한치과교정학회지
    • /
    • 제35권3호
    • /
    • pp.163-173
    • /
    • 2005
  • 본 연구는 안면비대칭 환자에서 경조직의 비대칭 정도와 연조직 비대칭 정도의 차이를 3차원적으로 밝히고자 시행되었다. 안면비대칭으로 보이는 성인 남녀 34명을 대상으로 두경부 전산단층사진을 촬영하고 3차원 입체영상으로 재구성한 후 기준평면에 대해 비대칭을 나타내는 5개의 계측항목을 경조직에 설정하고, 이에 대응하는 연조직 계측항목을 각각 설정한 후 3차원 계측을 시행하고 경조직과 연조직의 계측항목간 차이를 비교하였다. 이부편위측과 반대측간의 계측치 차이를 비교한 결과, 경조직과 연조직 모두에서 좌우측 계측치간에 통계적으로 유의한 차이가 관찰되었으며 경조직과 연조직의 비대칭 계측항목을 비교한 결과, 6개의 계측항목 모두에서 통계적으로 유의한 차이를 나타내었다. 이부편위를 나타내는 chin deviation, 하악지와 하악골체를 나타내는 frontal ramal inclination difference, frontal corpus inclination difference 항목은 경조직의 비대칭 정도에 비하여 연조직 비대칭 정도가 작게 나타난 반면, 입술경사를 나타내는 lip cheilion height difference, lip canting은 maxillary height difference, occlusal plane canting보다 크게 나타나 입술부위의 비대칭 정도는 하부 경조직의 비대칭 정도보다 큰 것으로 나타났다. 안면비대칭자에서 경조직과 연조직간 비대칭 정도 차이를 규명한 본 연구 결과는 안면비대칭 평가 시 경조직 외에 연조직 계측항목을 이용한 비대칭 분석도 필요함을 시사하였다.

3차원 형상 계측에 의한 인대의 하반신 형태 파악 (The Analysis of the Lower Part of Dress Forms Using Three-Dimensional Measurement System)

  • 이명희;정희경
    • 한국생활과학회지
    • /
    • 제14권2호
    • /
    • pp.303-312
    • /
    • 2005
  • The purpose of this research is to analyze the lower part of dress forms with different sectional rotation-angles ($e.g.\;9^{\circ},\;15^{\circ},\;30^{\circ},\;45^{\circ}$) using three-dimensional measurement system and to investigate measurement properties for dress making. The dress forms used in this experiment were size 8 and six types: four from Korea and two from Japan. The instrument and tools for three-dimensional measurement was Whole Body 3D scanner (Exyma-WBS2H). The analysis program used in this experiment was Rapid Form 2004 PP1 (INUS technology, Inc, Korea). The measurement of dress forms was done three times with different sectional rotation-angles and its data were analyzed using SPSS WIN 10.0 Package. The following results were obtained: 1. With mean and standard deviation of each measured part, it was found out that the dress forms from two countries were different in size per each part. For example, the Japanese one was relatively large in middle hip and hip, compared to the Korean one. 2. The 3D analysis of the sectional rotation-angles revealed some differences between the two dress forms in sectional length per each part. 3. With cluster analysis results, it was found that there were definite differences among measurements per each part, especially in $30^{\circ}\;and\;45^{\circ}$ sections. 4. The proportion of the dress forms showed significant differences in the curvature between center and side section of the lower parts. In addition, the shapes on the horizontal section map of the four levels (waist, middle hip, hip, and bottom) were analyzed.

  • PDF

슬랙스 맞음새 평가를 위한 하반신 체형 유형화에 관한 연구 (A Study on the Classification of Lower Body Shape Type for Fit Evaluation of Slacks)

  • 김선영;남윤자
    • 패션비즈니스
    • /
    • 제20권2호
    • /
    • pp.181-196
    • /
    • 2016
  • This study intended to suggest criteria for selection of subjects by lower body shape types necessary for evaluating slacks. For this, the characteristics were examined by lower body parts which would influence the fit of slacks on 3D human body shape data of the front and sides of the lower body for lower body shaping. The frequency of subjects by lower body shape types and the boundary points for discrimination of each type were suggested so that they could be available in selecting subjects. Using the data from Size Korea(2004), indirect measurement values measured on the front and sides of the lower body among 3D human body shape data of 175 subjects were analyzed. Their height, waist, and hip circumference fell under the range of standard deviation based on the mean of women aged 18~24 years, and then lower body shaping was conducted by combining the front and side shapes of the lower body. The front of the lower body was classified into four sections: average waist/average hip type(F1), average waist/narrow hip tyle(F2), narrow waist/narrow hip type(F3) and narrow waist/wide hip type(F4) and the sides of the lower body were divided into four sections: average abdomen/average hip type(S1), flat abdomen/average hip type(S2), average abdomen/protrude hip type(S3)and round abdomen/flat hip type(S4), and thus total 16 lower body types were created by cross analysis. Besides, discriminant analysis suggested the boundary points for each shape type of the front and sides of the lower body as a criterion for deciding lower body shape type of each subject