• Title/Summary/Keyword: 3D deviation

Search Result 714, Processing Time 0.028 seconds

Use of an anatomical mid-sagittal plane for 3-dimensional cephalometry: A preliminary study

  • Vernucci, Roberto Antonio;Aghazada, Huseynagha;Gardini, Kelly;Fegatelli, Danilo Alunni;Barbato, Ersilia;Galluccio, Gabriella;Silvestri, Alessandro
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.159-169
    • /
    • 2019
  • Purpose: Cone-beam computed tomography (CBCT) is widely used for 3-dimensional assessments of cranio-maxillo-facial relationships, especially in patients undergoing orthognathic surgery. We have introduced, for reference in CBCT cephalometry, an anatomical mid-sagittal plane (MSP) identified by the nasion, the midpoint between the posterior clinoid processes of the sella turcica, and the basion. The MSP is an updated version of the median plane previously used at our institution for 2D posterior-anterior cephalometry. This study was conducted to test the accuracy of the CBCT measures compared to those obtained using standard posterior-anterior cephalometry. Materials and Methods: Two operators measured the inter-zygomatic distance on 15 CBCT scans using the MSP as a reference plane, and the CBCT measurements were compared with measurements made on patients' posterior-anterior cephalograms. The statistical analysis evaluated the absolute and percentage differences between the 3D and 2D measurements. Results: As demonstrated by the absolute mean difference (roughly 1 mm) and the percentage difference (less than 3%), the MSP showed good accuracy on CBCT compared to the 2D plane, especially for measurements of the left side. However, the CBCT measurements showed a high standard deviation, indicating major variability and low precision. Conclusion: The anatomical MSP can be used as a reliable reference plane for transverse measurements in 3D cephalometry in cases of symmetrical or asymmetrical malocclusion. In patients who suffer from distortions of the skull base, the identification of landmarks might be difficult and the MSP could be unreliable. Becoming familiar with the relevant software could reduce errors and improve reliability.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Hardness and Microstructure evolution of SUS630 Stainless steel Fabricated by Directed Energy Deposition (Direct energy deposition 공정으로 제조된 SUS630 스테인리스강 적층조형체의 경도 및 미세조직 연구)

  • Back, Seong Eun;Noh, Kyung-Ho;Park, Jin Yong;Cho, Yong Ju;Kim, Jeoung Han
    • Journal of Powder Materials
    • /
    • v.25 no.3
    • /
    • pp.220-225
    • /
    • 2018
  • The microstructure and mechanical characteristics of SUS630 specimens fabricated using the direct energy deposition (DED) process are investigated. In DED, several process parameters such as laser scan speed, chamber gas flow, powder carrier gas flow, and powder feed rate are kept fixed; the laser power is changed as 150 W, 180 W, and 210 W. As the laser power increases, the surface becomes smooth, the thickness uniformity improves, and the size and number of pores decreases. With the increase in laser power, the hardness deviation decreases and the average hardness increases. The microstructure of the material is columnar; pores are formed preferentially along the columnar interface. The lath-martensite phase governs the overall microstructure. The volumetric fraction of the retained austenite phase is measured to increase with the increase of laser input power.

Morphological Properties and Target Strength Characteristics for dark banded rockfish (Sebastes inermis) (볼락의 형태학적 특징과 음향반사강도 특성)

  • Hwang, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.1
    • /
    • pp.120-127
    • /
    • 2015
  • Morphological properties of dark banded rockfish (Sebastes inermis) were analysed to investigate its acoustic scattering characteristics. Total of 18 live samples was prepared for X-ray photos and collected morphological coordinates of their body and swim bladder shapes. Kirchhoff-ray mode model was used to calculate acoustic scattering pattern for broad-band frequency range. Inclination of swim bladder ranged from 17 to 30 and the averaged value was about $25.2^{\circ}$ (S.D.(standard deviation)=3.15). There were no any tendency of increase or decrease in volume and area ratio of swim bladder to fish body and ranged from 2.2 % to 4.43 % and 14.85 % to 21.31 %, respectively. The averaged value of volume and area ratio was 3.13 % (S.D.=0.52) and 17.6 % (S.D.=1.5). $b_{20}$ values were -69.01 for 38 kHz, -69.83 for 70 kHz, -70.17 for 120 kHz and -70.93 for 200 kHz, recpectively. Broadband acoustic patterns of dark banded rockfish for 20 ~ 200 kHz were similar among samples and they reflected size and morphological properties of fish species.

Operation Characteristics of 5 kW Class Proton-Exchange-Membrane Fuel Cell(PEMFC) Stack (5 kW급 고분자 전해질 연료전지 스택의 운전 특성)

  • Kim, Jae-Dong;Lee, Jung-Woon;Park, Dal-Ryung
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.51-54
    • /
    • 2007
  • 78-cell proton exchange membrane fuel cell(PEMFC) stack with an effective electrode area of $295cm^{2}$ were investigated its operational characteristics and effects of CO poisoning. When power output, 5.4 kW, was released at current density of $325mA/cm^{2}$ for 6 hours, stablility of each cell was showed the small deviation of 2.3%. Carbon monoxide is a conventional contaminant in the fuel obtained from reforming processes with an important influence on the performance of the PEMFC. The studies of continuous injection of CO presented (5-20 ppm) with the time gave information about poisoning and recovery processes of the stack.

  • PDF

A Study on the Prediction of Mass and Length of Injection-molded Product Using Artificial Neural Network (인공신경망을 활용한 사출성형품의 질량과 치수 예측에 관한 연구)

  • Yang, Dong-Cheol;Lee, Jun-Han;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2020
  • This paper predicts the mass and the length of injection-molded products through the Artificial Neural Network (ANN) method. The ANN was implemented with 5 input parameters and 2 output parameters(mass, length). The input parameters, such as injection time, melt temperature, mold temperature, packing pressure and packing time were selected. 44 experiments that are based on the mixed sampling method were performed to generate training data for the ANN model. The generated training data were normalized to eliminate scale differences between factors to improve the prediction performance of the ANN model. A random search method was used to find the optimized hyper-parameter of the ANN model. After the ANN completed the training, the ANN model predicted the mass and the length of the injection-molded product. According to the result, average error of the ANN for mass was 0.3 %. In the case of length, the average deviation of ANN was 0.043 mm.

Efficient Designs to Develop a Design Space in Quality by Design (설계기반 품질고도화에서 디자인 스페이스 구축을 위한 효율적인 실험계획)

  • Chung, Jong Hee;Kim, Jinyoung;Lim, Yong B.
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.523-535
    • /
    • 2019
  • Purpose: We research on the efficient response surface methodology(RSM) design to develop a design space in Quality by Design(QbD). We propose practical designs for the successful construction of the design space in QbD by allowing different number of replicates at the box points, star points, and the center point in the rotatable central composite design(CCD). Methods: The fraction of design space(FDS) plot is used to compare designs efficiency. The FDS plot shows the fraction of the design space over which the relative standard error of predicted mean response lies below a given value. We search for practical designs whose minimal half-width of the tolerance interval per a standard deviation is less than 4.5 at 0.8 fraction of the design space. Results: The practical designs for the number of factors between two and five are listed. One of the designs in the list could be chosen depending on the experimental budget restriction. Conclusion: The designs with box points replications are more efficient than those with the star points replication. The sequential method to establish a design space is illustrated with the simulated data based on the two examples in RSM.

Correlations of Symmetry of the Trunk Muscle Thickness by Gender with the Spinal Alignment in Healthy Adults

  • Lim, Jae-Heon
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.6
    • /
    • pp.405-410
    • /
    • 2013
  • Purpose: Most studies have reported that the abdominal muscle thickness differs according to gender but none of these studies reported a gender difference in the thickness of the multifidus and erector spine. The spinal alignment is affected by the left and right balance in the trunk muscle. The aim of this study was to identify the trunk muscle symmetry according to gender and the correlations of the trunk muscle thickness with spinal alignment. Methods: Forty three subjects(27 males and 16 females) were enrolled in this study. The trunk muscle thickness was measured by ultrasonography. The trunk muscle, which consisted of the rectus abdominis (RA), external oblique abdominis (EOA), internal oblique abdominis (IOA), transverse abdominis (TrA), erector spine (ES), and multifidus (MF), was measured. The spinal alignment was measured by Formetric-III 3D analysis. The dependent variables of the spinal alignment were the trunk imbalance, trunk inclination, lateral deviation, and surface rotation. Results: The muscle thickness of the EOA muscle increased more significantly in the right side than the left side (p<0.05). Each left and right difference in the muscle thickness between the male and female group showed a significant difference (p<0.05) except for the TrA thickness. Significant positive correlations were observed between the ES and lateral deviation and between the TrA with trunk imbalance. Conclusion: These results suggest that asymptomatic men have a greater trunk muscle thickness than women but there was no difference between the left and right in healthy adults. The trunk muscle thickness of ES, TrA is related by the spinal alignment.

A Study on the Appropriateness of Virtual Machine for Reverse Engineering (역공학을 위한 가상머신의 적합성에 대한 연구)

  • Oh, Seokhyung;Chang, Byoungchun;Ro, Yunsik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.6
    • /
    • pp.31-38
    • /
    • 2014
  • The purpose of this study is to make virtual machine using a 3D modeller to perform reverse engineering. Through the intuitive designer's ability, approximated model of the object is created and used to extract the data and NC tool path. The extracted data make approximated curve by using NURBS curve fitting. And the curve is used to remodel. From these series of process, the final reverse engineering data of the objects can be obtained. Two conclusions are drawn from this study. First, initial deviation of the intuitive model is one of the important factors that determine the number of repetitions of the experiment. Due to the characteristic of intuitive curve, after a certain number of repetitions the average deviation increase and radiate rather than decrease.

Effect of Si on Spatter Generation and Droplet Transfer Phenomena of MAG Wwlding (MAG 용접의 스패터 발생 및 용적이행현상에 미치는 Si의 영향)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • v.17 no.3
    • /
    • pp.36-43
    • /
    • 1999
  • The effect of Si content in welding wires on spattering characteristics and droplet transfer phenomena was studied. In MAG welding using 80% Ar-20% $CO_2$ shielding gas, spattering characteristics and droplet transfer phenomena were varied with Si content of wire. With increasing Si content, the spattering ratio and the ratio of large size spatter $(d\geq1.0mm)$ were increased. The increase of Si content in molten metal made surface tension increase due to reduction of oxygen content, which resulted from deoxidizing action of silicon. The increase of surface tension resulted in unstable transfer phenomena and arc instability in both short circuit and spray region. With changing Si content of wire, spattering characteristics and droplet transfer phenomena was directly influenced by the variation of surface tension, compared with the effect of arc stability.

  • PDF