• Title/Summary/Keyword: 3D deviation

Search Result 717, Processing Time 0.033 seconds

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF

Effects of the Phase Noise in the Frequency Synthesizer on the SFH/M-NCFSK System (주파수 합성기의 위상 잡음이 SFH/M-NCFSK 시스템에 미치는 영향)

  • 손종원;이준서;유흥균;박진수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.685-691
    • /
    • 2003
  • This paper newly analyzes the effect of the phase noise in the frequency synthesizer on the performance of SFH/M-NCFSK system by standard frequency deviation(equation omitted) when noncoherent FSK demodulation of the square-law detector is considered. We derive the SER in the SFH system and analyze the effect of phase noise on the SFH/M-NCFSK system performance according to the hopping frequency spacing (1/T$\_$h/) and the variation of the standard frequency deviation (equation omitted). The required SNR is about 13.4 dB to meet Ps=10$\^$-3/ when the standard frequency deviation is about 4.0 Hz and the hopping frequency spacing (1/T$\_$h/) in the SFH/2-NCFSK system is 30. So, there is about 2.4 dB power penalty than the phase noise-free system. If the hopping frequency spacing 1/T$\_$h/ is under 30, the error floor may happen and SER considerably grows up. We show that the analytic results closely match with the simulation results.

Comparison of three midsagittal planes for three-dimensional cone beam computed tomography head reorientation

  • Lee, Eon-Hwa;Yu, Hyung-Seog;Lee, Kee-Joon;Han, Sang-Sun;Jung, Hwi-Dong;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.3-12
    • /
    • 2020
  • Objective: This study compared three prominent midsagittal planes (MSPs) to identify the MSP that best approximates the true symmetrical MSP. Methods: Forty-three patients (mean age, 23.0 ± 8.20 years) were grouped as follows: group 1 consisted of 10 patients with skeletal Class I and a menton (Me) deviation of < 2 mm; group 2, 11 patients with skeletal Class III and a Me deviation < 2 mm; group 3, nine patients with skeletal Class III and a Me deviation of 2 to less than 4 mm; and group 4, 13 patients with skeletal Class III and an Me deviation ≥ 4 mm. The candidate MSPs were established by three-dimensional (3D) cone beam computed tomography (CBCT) reorientation methods (RMs): (1) the MSP perpendicular to the Frankfort horizontal (FH) plane while passing through the crista galli and basion; (2) the MSP including the nasion, incisive foramen, and basion; (3) the MSP including the nasion, anterior nasal spine, and posterior nasal spine. The mean absolute distances (MADs) to the MSPs were calculated from the coordinates of 1,548 points on 129 CBCT images. The differences in the values of the 3D coordinates among RMs were compared. Results: The MADs of the three RMs showed significant differences (p < 0.05). Most of the differences in values of the coordinates were not significant among RMs. Conclusions: Although the differences in distance among the three MSPs were minor, the MSP perpendicular to the FH plane while passing through the crista galli and basion best approximated the true symmetrical MSP.

A Study on the Forming of Eine Gear Housing using Rapid Prototyping (RP를 이용한 미세기어 하우징 성형에 관한 연구)

  • 김성욱;이기성;이승수;김민주;전언찬
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.441-447
    • /
    • 2003
  • In the study, we described on the 3D solid model be made on the AutoCAD haved an effect on the deviation of form as RP manufactures the facetres. The STL file improved the deviation of form as the facetres value but the deviation of form have the difference a little as the RP system. In result, we ruled the correlation with the 3D solid model and the RP sample manufacturing, with manufacture RP sample according to facetres value in complex shape. And we developed the program which recombination the STL file that we make use of the AutoLISP.

  • PDF

Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures (얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교)

  • Jung, Jong Myung;Kim, Jong Whan;Hong, In Pyo;Choi, Chi Hoon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

Development of a Simple Drape Measurement Method for 3D Virtualization (3D 가상화를 위한 드레이프성 간이 측정법 개발)

  • Shin, Bona;Yu, Dongjoo;Lee, Somin;Youn, Seonyoung;Shim, Myounghee;Yun, Changsang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.5
    • /
    • pp.881-891
    • /
    • 2021
  • This study proposes a simple drape measurement method for the 3D virtualization of garments. The proposed method uses angles or disks of different diameters to evaluate the drape properties easily. We divided 710 fabrics into ten groups based on the drape coefficient, of which 49.6% had drape coefficients of 30 or less. The drape properties were measured to classify the groups into smaller clusters using the angle formed when the center of the fabric was fixed. Accordingly, three clusters were formed for 60° and 100° angles. A method was devised using ten disks of different diameters to classify the remaining two clusters, except the cluster containing only the D10 group (D1-D5 and D5-D9). Three criteria-grade match, a sum of deviation, and standardization of deviation-were used for the classifications. The discriminative ability between groups was high for D1-D5 with disks with 24.0 and 25.5 cm diameters. Furthermore, a disk with a diameter of 16.5 cm was effective for D5-D9. The three-dimensional drape shapes were unique for the ten groups, which can be utilized as fundamental data for 3D virtualization.

A Study on the Optimized Measurements of Field Uniformity for Electromagnetic Radiated Immunity Test System (전자파 방사 내성 시험을 위한 최적화된 균일장 측정 방법에 관한 연구)

  • Cho Jin-Young;Mun Jun-Chul;Jung Chang-Kyoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.622-631
    • /
    • 2005
  • In this paper, we reduce 'over and under deviation' and 'over and under testing' which have a cause of uncertainty in electromagnetic radiated immunity test. We analyze continued measurement method of field uniformity and propose new estimate method having the minimum uncertainty condition. We test comparison in 4 anechoic chambers and analyze FDI(Field Deviation Index) which is the minimum deviation excess 6 dB on fields. We obtain that the proposed test method improve 1.193 dB than domestic standard(KN 61000-4-3) and 0.017 dB than international standard (IEC61000-4-3) in every frequency. In the test result 'over and under testing point' have 926 point at every field area and have 118 point at center uniform area. These result know that proposed measurement method have 10 point less at every field area and 9 point less at center uniform area than continued measurement method. The proposed test method have few point more than continued measurement method. Therefore, we confirmed that the proposed test method have the minimum uncertainty in electromagnetic radiated immunity test.

A Study of Senior Men's Dress Form Development 3D Digital Technology (3D 디지털 기술을 활용한 시니어 남성 기성복 피팅용 드레스폼 개발에 관한 연구)

  • Do, Wolhee;Choi, Eunhee
    • Fashion & Textile Research Journal
    • /
    • v.20 no.6
    • /
    • pp.722-732
    • /
    • 2018
  • This study was to develop a dress form that is highly representative of the body shapes of senior men in their 50s and 60s. And this research was compared the measurements and forms of three different dress forms available in the market, in order to analyze the body type and suitability and provide a standard for developing and utilizing the dress forms. After extracting the body shapes of the senior men's 3D shape, the body type that is curvature on the back prevalent among senior men, was chosen. The dress form was created as follows: 3D modeling and rendering, printing with a FDM-type 3D printer. The dress forms were 3D-scanned and the 3D data was analyzed - classification drop value, area deviation, compared horizontal section and vertical section. The results were as follows: This suggested that the area deviation amount at the chest and hip circumference levels was larger in the commercial products than in the dress form in this study, while that at the waist circumference level was larger in the dress form in this study. The vertical length of the lateral shoulder point-waist circumference was smaller, the side shape showed severe curvature on the back, and the waist circumference was larger in the senior men dress form than the commercial products. The dress form developed in this study reflected the body type of senior men and, therefore, were suitable for fitting when creating clothes for senior men.

Comparison of the three-dimensional structures of mandibular condyles between adults with and without facial asymmetry: A retrospective study

  • Oh, Min-Hee;Kang, Sung-Ja;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.48 no.2
    • /
    • pp.73-80
    • /
    • 2018
  • Objective: This retrospective study compared the three-dimensional (3D) structure of mandibular condyles between adults with and without facial asymmetry, and whether it influences menton deviation. Methods: Sixty adult patients were classified into symmetry and asymmetry groups based on the menton deviation on postero-anterior radiographs. The right/left differences of 3D measurements were compared between the two groups, and measurements were compared separately on the right and left sides. The correlations between menton deviation and the right/left differences were analyzed. Results: The mediolateral dimension, neck length, condylar angles to the anteroposterior reference (PO) and midsagittal reference planes, and neck and head volumes showed significantly larger right/left differences in the asymmetry group compared to the symmetry group. Separate comparisons of the right and left sides between the two groups showed that the neck was significantly shorter and neck and head volumes were significantly smaller on the left side, which was deviated side in the asymmetry group. Pearson's correlation analysis showed significant positive correlations of menton deviation with right/left differences in neck length, condylar angle to the PO plane, and neck and head volumes in the asymmetry group. Conclusions: In individuals with facial asymmetry, menton deviation is associated with the right/left differences caused by a smaller condyle on the deviated side, particularly in neck length and neck and head volumes.

Imaging of Fractures and Tunnel by 3-D ERT (전기비저항 토모그래피에 의한 파쇄대 및 터널의 3차원 영상화)

  • Yi, Myeong-Jong;Kim, Jung-Ho;Son, Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.302-309
    • /
    • 2008
  • ERT imaging, especially 3-D method, is a very powerful means to obtain a very high resolution image of the subsurface for geotechnical or hydrogeological problems. In this paper, we introduce two examples of successful case histories, where the imaging targets were three-dimensional. First example is the case of 3-D fracture imaging for hydrogeologic application. In this example, the borehole deviation was a critical problem in the ERT imaging and we could obtain real 3-D attitude of fracture system by including the borehole deviation in the inversion. In the second case, we did field experiment to image the empty tunnel with the size of $2m{\times}2m$ and the target was very clearly imaged in 3-D space. In these examples, we could show that 3-D ERT imaging is a very powerful tool for the 3-D subsurface imaging and the method can provide enhanced imaging capabilities especially for the 3-D targets such as fractures and cavities or tunnel.