• 제목/요약/키워드: 3D code

Search Result 1,381, Processing Time 0.032 seconds

Impedance-matching Method Improving the Performance of the SAW Filter (탄성표면파 필터의 성능 개선을 위한 임피던스 정합의 해석적 방법)

  • 이영진;이승희;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.69-75
    • /
    • 2001
  • In this paper, a fast and easy impedance matching method, which could give the impedance matching component for the general 1 or 2-port network was introduced. First, the entire network structure was defined which consists of the network part to be matched and the impedance matching part composed of inductors and capacitors. Next, the transmission matrix and input and output impedances of the entire network from the terminal impedance conditions were calculated, then the exact solutions for the matching components were obtained. To verify the efficiency of this method, this method was applied to the CDMA If band withdrawal weighted SAW transversal filter, and investigated the effects of the impedance matching before and after, through the simulation and experiment. As the result, the performance of a fractional bandwidth of 1.2%, insertion loss of 29 dB, and VSWR of 80 have improved to a factional bandwidth of 1.8%, insertion loss of 9 dB, VSWR of 3 at 85.38 MHz center frequency. The result shows that this impedance matching method could be used in the SAW devices and other types of 1 or 2-port network.

  • PDF

A method of wall absorption treatment for enhancing the speech intelligibility at a directional microphone array in a room (실내 공간 내 지향성 마이크 어레이에서의 음성 명료도 개선을 위한 벽면 흡음 처리 방법)

  • Ko, Byeong-Yun;Ih, Jeong-Guon;Cho, Wan-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.649-659
    • /
    • 2021
  • Wall absorption treatment effectively reduces reverberation, but requires a large area for a live room and each wall absorption affects speech intelligibility differently. In this study, we try to find the most effective wall for the absorption treatment using the beamforming array microphone in terms of speech intelligibility. The absorption importance factor is defined by using the collision number of reflected sounds on each wall. It allows estimating how much the speech signal will be enhanced by the absorption treatment. A cuboid room with a size of 107 m3 and a reverberation time of 1.1 s is selected for the simulation. When a Helmholtz-type absorption is treated on the wall with the most significant importance factor, the modified clarity for 500 and 1k Hz is improved by 5.1 dB and 4.8 dB respectively, and the speech transmission index is enhanced by 0.06. The difference in results between the proposed method and commercial simulation code is less than a Just-Noticeable Difference (JND). The absorption treatment on the wall with the most significant importance factor shows improvement greater than the wall with the largest area, and its difference is larger than a JND value.

Performance Analysis of MC-DS/CDMA System with Phase Error and Hybrid SC/MRC-(2/3) Diversity (위상 에러와 하이브리드 SC/MRC-(2/3)기법을 고려한 MC-DS/CDMA 시스템의 성능 분석)

  • Kim Won-Sub;Park Jin-Soo
    • The KIPS Transactions:PartC
    • /
    • v.11C no.6 s.95
    • /
    • pp.835-842
    • /
    • 2004
  • In this paper, we have analyzed the MC-DS/CDMA system with input signal synchronized completely through adjustment of the gain in the PLL loop, by using the hybrid SC/MRC-(2/3) technique, which is said to one of the optimal diversity techniques under the multi-path fading environment, assuming that phase error is defined to the phase difference between the received signal from the multi-path and the reference signal in the PLL of the receiver. Also, assuming that the regarded radio channel model for the mobile communication is subject to the Nakagami-m fading channel, we have developed the expressions and performed the simulation under the consideration of various factor, in the MC/DS-CDMA system with the hybrid SC.MRC-(2/3) diversity method, such as the Nakagami fading index(m), $the\;number\;of\;paths\;(L_p),$ the number of hybrid SC.MRC-(2/3) $diversity\;branches\;(L,\;L_c),$ the number of users (K), the number of subcarriers (U), and the gain in the PLL loop. As a result of the simulation, it has been confirmed that the performance improvement of the system can be achieved by adjusting properly the PLL loop in order for the MC/DS-CDMA system with the hybrid SC/MRC-(2/3) diversity method to receive a fully synchronized signal. And the value of the gain in the PLL loop should exceed 7dB in order for the system to receive the signal with prefect synchronization, even though there might be a slight difference according to the values of the fading index and the spread processing gain of the subcarrier.

Numerical Study of a Droplet Movement for the Ocean $CO_2$ Sequestration ($CO_2$해양처리를 위한 액적 거동 시뮬레이션 기초연구)

  • Jung Rho-Taek;Kang Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.1
    • /
    • pp.39-45
    • /
    • 2005
  • In the situation which Russia's ratification of the Kyoto protocol at February,2004, ANNEX I nations must reduce GHG(Green House Gas) discharge rate from 2008 by 2012 to the reduction level at 1990. We introduce the CO₂ ocean sequestration that is one of promising method for getting the stable CO₂ concentration in the atmosphere. There are four categories : ocean transportation technique, ocean initial dissolution technique, ocean deep current evaluation technique, and ocean biological evaluation technique. In this paper, we carried out the fundamental numerical study on the ocean initial dissolution technique, when the Liquidized CO₂ is emitted at the deep ocean, It is very important to the dissolution rate of movable CO₂ interface because it Is directly impact to the ocean organism. In order to investigate the relation of the interface movement and rate of the dissolution, we develope CR(Computational Fluid Dynamics) code that was constructed by the finite volume method based on the unstructured mesh, and a droplet's boundary surface can move and one direction dissolution from disperse phase into continuous phase adopted as its physics be. This study clarifies hydrodynamic relation between solubility and movement of the droplet through the verification of the Cm code.

  • PDF

Analysis of Technology Convergence Structure Using technology Input-output Analysis: Case of Convergence R&D Development Project for Small and Medium Businesses (기술연관분석을 활용한 기술융합구조 분석: 중소기업 융·복합기술개발사업 사례)

  • Lee, Kwang-Min;Kim, Da-Woon;Hong, Jae-Bum
    • Journal of Technology Innovation
    • /
    • v.22 no.3
    • /
    • pp.1-35
    • /
    • 2014
  • This study analyzed convergence status among input technologies used in technology development with Technology I-O analysis. It was another version of industry input-output analysis which is used in technology planning. This case is an analysis of association between technology an product. The subjects of analysis were 401 tasks that applied to '2012 Convergence Technology Development Project for Small and Medium Businesses' promoted by Korea Technology & Information Promotion Agency for Small and Medium Enterprises. The process of analysis is as followed. First step, we made a matrix table as an input of technology input-output analysis. Input was defined by technology and output was defined by the product. Input technology was defined in a 3-digit code under National Science Technology Classification and output products were defined in a 5-digit under National Standard Industry Code. Second, the Spillover ratio among technologies were calculated and was used to make a picture of technology linkage. As a result of analysis, technology spillover of embedded S/W was the highest in IT convergence, mold product in ET convergence, and functional cosmetics development technology in BT convergence. In general, IT convergence had many element technologies with high technology spillover, and ET had a small number of element technologies with high technology spillover. Therefore, investment effect of element technology is expected to be large if investment on element technologies with high technology spillover is important for vitalizing convergence.

Design and Implement of 50MHz 10 bits DAC based on double step Thermometer Code (50MHz 2단 온도계 디코더 방식을 사용한 10 bit DAC 설계)

  • Jung, Jun-Hee;Kim, Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.18-24
    • /
    • 2012
  • This paper reports the test results of a 50MHz/s 10 bits DAC developed with $0.18{\mu}m$ CMOS process for the wireless sensor network application. The 10bits DAC, not likely a typical segmented type, has been designed as a current driving type with double step thermometer decoding architecture in which 10bits are divided into 6bits of MSB and 4bits of LSB. MSB 6bits are converted into 3 bits row thermal codes and 3 bits column thermal codes to control high current cells, and LSB 4 bits are also converted into thermal codes to control the lower current cells. The high and the lower current cells use the same cell size while a bias circuit has been designed to make the amount of lower unit current become 1/16 of high unit current. All thermal codes are synchronized with output latches to prevent glitches on the output signals. The test results show that the DAC consumes 4.3mA DC current with 3.3V DC supply for 2.2Vpp output at 50MHz clock. The linearity characteristics of DAC are the maximum SFDR of 62.02dB, maximum DNL of 0.37 LSB, and maximum INL of 0.67 LSB.

Computational Structural Dynamic Analysis of a Gyrocopter Using CFD Coupled Method (CFD기법을 연계한 자이로콥터의 전산구조동역학 해석)

  • Kim Hyun-Jung;Jung Se-Un;Park Hyo-Keun;Yang Chang-Hak;Kim Dong-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.295-302
    • /
    • 2006
  • In this study, computational structural dynamic analyses of a gyrocopter have been conducted considering unsteady dynamic hub-loads due to rotating blades. 3D CATIA models with detailed mechanical parts we constructed and virtually assembled into the complete aircraft configuration. The dynamic loading generated by rotating blades in the forward flight condition are calculated by a commercial computational fluid dynamics (CFD) code such as FLUENT. Modal based transient and frequency response analyses are used to efficiently investigate vibration characteristics of the gyrocopter. Free vibration analysis results for different fuel and pilot conditions, frequency responses and transient responses for critical flight conditions are also presented in detail.

Multiview Video Sequence CODEC with View Scalability (View Scalability를 고려한 다시점 동영상 코덱)

  • 임정은;손광훈
    • Journal of Broadcast Engineering
    • /
    • v.9 no.3
    • /
    • pp.236-245
    • /
    • 2004
  • A multiview sequence CODEC with view scaiability is proposed in this paper. We define a GGOP (Group of GOP) structure as a basic coding unit to efficiently code multiview sequences. 7he proposed CODEC provides flexible GGOP structures based on the number of views and baseline distances among cameras. Multiview sequences encode consists of disparity estimation/compensation, motion estimation/compensation, residual coding and rate control and generates multiview sequence bitstream. The main bitstream is the same as an MPEG-2 mono-sequence bitstream for MPEG-2 compatibility. The auxiliary bitstream contains information concerning the remaining multiview sequences except for the reference sequences. The proposed CODEC with view scalability provides that a number of view flints are selectively determined at the receiver according to the type of display modes. The proposed multiview sequence CODEC is tested with several multiview sequences to determine its flexibility. compatibility with MPEG-2 and view scaiability. In addition, we subjectively confirm that the decoded bitstreams with view scaiability can be Properly displayed by several types of display modes. including 3D monitors.

3-D Hydrodynamics and Temperature Modeling Using EFDC (EFDC를 이용한 3차원 수리-수온 모델링)

  • Seo, Dong-Il;Kwon, Ki-Hoan;Park, Byung-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2220-2224
    • /
    • 2009
  • 하천의 수질모의를 위해서는 정상상태 모델인 QUAL2E 가 널리 사용되어 왔다. 그러나 우리나라는 기후 특성상 하절기에 강우가 집중되고 경우에 따라서는 댐등에 의해 장기간 수류의 지체현상이 발생하므로 지역 및 시기에 따라 발생하는 수질 문제가 서로 다를 수 있다. 따라서 우리나라의 대부분의 수체에서는 시간에 따라 모의를 할 수 있는 비정상 상태의 수질모델이 적용되어야 할 필요가 종종 발생한다. 미국공병단에서 개발된 CE-QUAL-W2 모델은 2차원 모델로서 수리동역학과 수질반응역학을 한데 묶어서 풀이하였다는 점에서 획기적인 변화로 볼 수 있다. 이 모델은 종방향으로 길고 수심이 깊으며 상대적으로 하폭이 좁은 형태의 수체에 적합하며 하폭방향의 수질 변화를 나타내는 데 사용되지 못하는 단점이 있다. WASP(Water Quality Analysis and Simulation Program) 은 미국 환경부에서 개발한 비정상상태 3차원 수질모델로서 세계적으로 다양한 수체에 널리 사용되어 왔다. 이 모델에서 1차원적 흐름을 예측할 수 있는 DYNHYD 라는 수리학적 부프로그램은 2차원 또는 3차원 상황에서는 사용할 수가 없었음에 따라 수리학적 고려가 빈약한 것이 이 모델의 가장 큰 약점으로 지적되어 왔다. 최근 미국 환경부는 EFDC(Environmental Fluid Dynamics Code) 라는 3차원 수리동역학 프로그램을 이용하여 대상 수체의 수리학적 거동을 모의하고 그 결과를 WASP7 에 연계시킬 수 있도록 하여 기존의 단점을 대폭 보완하였다. 본 연구에서는 금강 상류에 위치하고 있는 용담호를 대상으로 EFDC 를 이용하여 2005년 1년간 수위 및 수온성층현상을 예측하고 그 결과가 WASP 에 연결되어 사용될 수 있도록 하였다. 적절한 격자의 수를 결정하기 위하여 다양한 경우가 시행착오적으로 시험되었으며 비교적 적은 숫자의 격자로도 수위 및 수온의 모의가 가능하다는 것을 발견하였다.

  • PDF

Necessary Conditions for Optimal Ventilation of Small Windowless Piglet House with Negative Tunnel Ventilating System (소규모 음압터널환기방식 무창자돈사의 최적 환기 요건에 관한 연구)

  • Lee, Seung-Joo;Chang, Dong-Il;Gutierrez, Winson M.;Park, Jeong-Sik;Jeon, Sang-Hoon;Cho, Hyoung-Je;Oh, Kwon-Young;Chang, Hong-Hee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.63-68
    • /
    • 2009
  • This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (5.2 (W) ${\times}$ 12.3 (L) ${\times}$ 2.3 (H) m) with negative tunnel ventilating system using CFD (Computational Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 4 rooms (520 (W) ${\times}$ 300 (L) cm), 3 fences (70 (H) cm), 1 air inlet (350 (W) ${\times}$ 2 (H) cm) and 1 exhaust fan (50 (D) cm), and simulated using CFD code, FLUENT. The simulation results for the original weaning piglet house showed ununiform ventilation for each room. Therefore, to uniformly ventilate all rooms, the heights of the air inlet and first fence were modified to 3 cm and 100 cm, respectively. The simulation result f3r the modified weaning piglet house showed uniform ventilation for all rooms and the optimum air inlet velocity of 1.4 m/s.