• Title/Summary/Keyword: 3D body data

Search Result 856, Processing Time 0.029 seconds

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

Sugarcane bagasse as exclusive roughage for dairy cows in smallholder livestock system

  • de Almeida, Gleidiana Amelia Pontes;Ferreira, Marcelo de Andrade;Silva, Janaina de Lima;Chagas, Juana Catarina Cariri;Veras, Antonia Sherlanea Chaves;de Barros, Leonardo Jose Assis;de Almeida, Gledson Luiz Pontes
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.3
    • /
    • pp.379-385
    • /
    • 2018
  • Objective: The study aimed to evaluate sugarcane bagasse as roughage in lactating cow on feed intake, digestibility, ingestive behavior, milk production and composition, and microbial protein synthesis. Methods: Ten Girolando cows at initial body weight of $450{\pm}25.6kg$ and at $143.7{\pm}30.7days$ in milk were assigned in two $5{\times}5$ Latin square designs. Five 21-day experimental periods were adopted ($1^{\circ}$ to 14-day: diets adaptation period; $15^{\circ}$ to 21-day: data collection and sampling period). The diets consisted of four different levels of sugarcane bagasse (45%, 50%, 55%, and 60%) and a control diet, commonly adopted in the region, based on spineless cactus (25% sugarcane bagasse), formulated to meet 12 kg/d milk yield. Results: The dry matter (DM), organic matter (OM), and total digestible nutrients intakes and DM and OM digestibilities observed for 45% and 50% bagasse inclusion were similar to control diet, while that 55% and 60% bagasse inclusion were lower. Cows fed control diet, and bagasse diets of 45%, and 50% levels had the nutritional requirements attended, that guaranteed 12 kg/d of milk yield. The crude protein intake and digestibility of cows fed 45%, 50%, and 55% of bagasse inclusion were similar to control diet. The neutral detergent fiber (NDF) intake and digestibility differ for all bagasse diets related to control diet, while the non-fiber carbohydrates intake and digestibility for cows fed 45% of bagasse were similar for control diet. The intakes and digestibilities of nutrients decreased linearly in function of bagasse inclusion; NDF and indigestible NDF intakes did not vary. The ruminating time, feeding and rumination efficiency, microbial protein synthesis and milk yield decreased linearly with sugarcane bagasse inclusion. Conclusion: Sugarcane bagasse decreases milk production; however, its inclusion level in between 45% to 50% associated to concentrate could replace diets based on spineless cactus for crossbred dairy cow's producing 12 kg/d of milk.

Effect of Copper Source (Cupric Citrate vs Cupric Sulfate) and Level on Growth Performance and Copper Metabolism in Pigs

  • Armstrong, T.A.;Spears, J.W.;van Heugten, E.;Engle, T.E.;Wright, C.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.8
    • /
    • pp.1154-1161
    • /
    • 2000
  • Two experiments were conducted to evaluate the efficacy of cupric citrate (Cu-citrate) relative to cupric sulfate $(CuSO_4)$ as a Cu source for weanling and grow-finish pigs. In addition, the use of liver and bile Cu concentrations as indices of the bioavailability of Cu sources was investigated. Experiment one consisted of a nursery phase (35 d; initial BW=6.4 kg, final BW=21.4 kg) followed by a grow-finish phase (103 d; initial BW=21.5 kg, final BW=111.7 kg). Experiment two only consisted of a nursery phase (35 d; initial BW=6.3 kg, final BW=18.6 kg). Dietary treatments were identical for both experiments and consisted of: control (10 ppm $CuSO_4$); control+66 or 225 ppm $CuSO_4$; control+33, 66, or 100 ppm Cu-citrate. An antibiotic was included in diets for Exp. 1 but not Exp. 2. In both experiments, growth performance variables were similar for pigs receiving Cu-citrate and $CuSO_4$; however, growth performance was not improved by high concentrations of $CuSO_4$. Liver and bile Cu were increased (p<0.05) by 225 ppm $CuSO_4$; however, lower dietary concentrations of Cu from either $CuSO_4$ or Cu-citrate did not affect the Cu concentration of liver or bile relative to that observed in the control pigs. Irrespective of Cu source, there was no linear (p>0.10) increase in plasma Cu with increasing Cu concentrations in the diet for both experiments. However, the plasma Cu concentrations were highest (p<0.10) in pigs receiving diets supplemented with 225 ppm $CuSO_4$. Sixteen randomly chosen pigs per treatment in Exp. 1 were continued through the grow-finish phase. Body weight gain and feed intake were improved (p<0.10) by 66 ppm $CuSO_4$, but other dietary Cu treatments did not alter pig performance compared to the control diet. Plasma Cu concentrations were increased (p<0.10) by 225 ppm $CuSO_4$ in the growing phase and by 225 ppm $CuSO_4$ and 100 ppm Cu-citrate in the finishing phase. These data reveal no consistent effect of $CuSO_4$ on performance; therefore, it is difficult to assess the efficacy of these two Cu sources. In addition, these studies demonstrate that liver and bile Cu are not good indicators of Cu bioavailability in pigs fed adequate to pharmacological concentrations of Cu.

FE-Analysis on void closure behavior during hot open die forging process (열간 자유단조 공정시 내부 기공 압착 거동에 관한 해석)

  • Kwon, Y.C.;Lee, J.H.;Lee, S.W.;Jung, Y.S.;Kim, N.S.;Lee, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.160-164
    • /
    • 2007
  • In the steel industry, there is a need to produce large forged parts for the automobile industries, the flight and shipping industries ad military industries. In the steel-industry application, a cogging technique for cast ingots is required, because the major parts are needed as one large body in order to obtain higher quality. Therefore, cogging process is the primary step in manufacturing of practically large open-die forging. In the cogging process, internal voids have to be eliminated as defects, The present work is concerned with the elimination of the internal voids in large ingots so as obtain sound products. In this study, hot compression tests were carried out to obtain the flow stress of cast microstructure at different temperature and strain rates. The FEM analysis are performed to investigate the overlap defect of cast ingots during cogging stage. The measure flow stress data were used to simulate the cogging process of cast ingot using the practical material properties. Also the analysis of void closure are performed by using the $DEFORM^{TM}$-3D. The calculated results of void closure behavior are compared with the measured results before and after cogging, which are scanned by the X-ray scanner. From this result, the criteria for deformation amounts effect on the void closure can be investigated by the comparison of practical experiment and numerical analysis.

  • PDF

A Study on Satisfaction and Formative Appropriateness of Leisure Sports Jumpers For Elderly Women (노년 여성 레포츠 점퍼에 대한 만족도 및 형태적합성 연구)

  • Lee, Hyo-Jin;Kim, Jin
    • Korean Journal of Human Ecology
    • /
    • v.19 no.1
    • /
    • pp.119-126
    • /
    • 2010
  • We need to develop a target market for elderly women by increasing the ratio of functional apparel. The purpose of this study was to provide basic data for developing a Leisure Sports Jumper and improving the quality of life of clothing for female elderly consumers. This study reviewed the current situation on the production of the functional Leisure Sports Jumper for the elderly women in literature. For the experimental study, we selected Leisure Sports Jumpers from five apparel brands, and evaluated a sensory test on 20 subjects representing the average body shape of the elderly women aged from 65 to 75. After the first sensory test, we manipulated the patterns for samples of the Leisure Sports Jumper. In the second sensory test, visual and cognitive appropriateness of the Leisure sports jumpers were assessed by the elderly women. The results of the study were as follows: the Leisure Sports Jumper of brand 'C' showed the highest appropriateness in terms of neck, armholes, and sleeves among the 5 brands. The Leisure Sports Jumper of brands 'B' and 'D' showed the lowest appropriateness in the width of the armpits among the 5 brands. Except for the length of the Leisure Sports Jumper, the margin, location of the pocket, and armholes had the lowest score in the first test showing over 3.5 points.

320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection (도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS))

  • Oh, Tong-In;Lee, Min-Hyoung;Kim, Hee-Jin;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

Design and Development of Virtual Reality Exergame using Smart mat and Camera Sensor (스마트매트와 카메라 센서를 이용한 가상현실 체험형 운동게임 시스템 설계 및 구현)

  • Seo, Duck Hee;Park, Kyung Shin;Kim, Dong Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2297-2304
    • /
    • 2016
  • In this study, we designed and developed the virtual reality Exergame using the smart mat and the camera sensor for exercises in indoor environments. For detecting the gestures of a upper body of users, the KINECT camera based the gesture recognition algorithm used angles between user's joint information system was adopted, and the smart mat system including a LED equipment and Bluetooth communication module was developed for user's stepping data during the exercises that requires the gestures and stepping of users. Finally, the integrated virtual reality Exergame system was implement along with the Unity 3D engine and different kinds of user' virtual avatar characters with entertainment game contents such as displaying gesture guideline and a scoring function. Therefore, the designed system will useful for elders who need to improve cognitive ability and sense of balance or general users want to improve exercise ability and the indoor circumstances such home or wellness centers.

Prediction of Cement Volume for Vertebroplasty Based on Imaging and Biomechanical Results

  • Lee, Sung-Jae;Tack, Gye-Rae;Lee, Seung-Yong;Jun, Bong-Jae;Lim, Do-Hyung;Shin, Jung-Woog;Kim, Jeong-Koo;Shin, Kyu-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1041-1050
    • /
    • 2001
  • Control of bone cement volume (PMMA) may be critical for preventing complications in vertebroplasty, the percutaneous injection of PMMA into vertebra. The purpose of this study was to predict the optimal volume of PMMA injection based on CT images. For this, correlation between PMMA volume and textural features of CT images was examined before and after surgery to evaluate the appropriate PMMA amount. The gray level run length analysis was used to determine the textural features of the trabecular bone. Extimation of PMMA volume was done using 3D visualization with semi-automatic segmentation on postoperative CT images. Then, finite element (FE) models were constructed based on the CT image data of patients and PMMA volume. Appropriate material properties for the trabecular bone were assigned by converting BMD to elastic modulus. Structural reinforcement due to the changes in PMMA volume and BMD was assessed in terms of axial displacement of the superior endplate. A strong correlation was found between the injected PMMA volume and the area of the intertrabecular space and that of trabecular bone calculated from the CT images (r=0.90 and -0.90, respectively). FE results suggested that vertebroplasty could effectively reinforce the osteoporotic vertebra regardless of BMD or PMMA volume. Effectiveness of additional PMMA injection tended to decrease. For patients with BMD well lower than 50mg/ml, injection of up to 30% volume of the vertebral body is recommended. However, less than 30% is recommended otherwise to avoid any complications from excessive PMMA because the strength has already reached the normal level.

  • PDF

Computational study of the hemodynamics of the patients after the Fontan procedure (Fontan 시술 이후 환자의 혈류역학적 상태에 대한 수치적 연구)

  • Shim, Eun-Bo;Ko, Hyung-Jong;Kim, Kyung-Hoon;Kamm, Roger D.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.371-376
    • /
    • 2000
  • In this study, the computational method is presented to simulate the hemodynamics of the patients after the Fontan procedure. The short-term feedback control models are implemented to assess the hemodynamic responses of the patients exposed to the stresses such as gravitational effect or hemorrhage. To construct the base line of the Fontan model, we assume an increase in venous tone, in heart rates, and in systemic resistance that are based on the clinical observations. For the verification of the present method we simulate the LBNP (lower body negative pressure) test for the normal and the Fontan model and we compare these with experimental data. Computational results show that the diastolic ABP(arterial blood pressure) increases but the systolic ABP decreases during LBNP. The increase in heart rate is due to the control system activated by the decreased mean ABP and CVP(central venous pressure). In case of the Fontan model, the increased venous tone is the reason of the diminished CVP change during LBNP. We also simulate 20% hemorrhage stress to the patient after the Fontan procedure and these results are compared with the experimental and the existing computational one. Computational results on the hemodynamics of patients after the Fontan procedure show that the mean ABP and cardiac output decrease. Heart rate and systemic resistance increase to compensate for the decrease in ABP. The sensitivity analysis according to the conduit resistance is also presented to delineate the effects of the local blood flow resistance. The cardiac output decreases according to the increase of the conduit resistance. The 50% increase in the conduit resistance causes about 3% decrease of cardiac output.

  • PDF

Effect of Supplemental Fish Meal on Milk Yield and Milk Composition of Holstein Cows during Early Lactation

  • Adachi, N.;Suzuki, K.;Kasai, K.;Hiroki, M.;Kume, S.;Nonaka, I.;Abe, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.3
    • /
    • pp.329-333
    • /
    • 2000
  • Data of 15 multiparous Holstein cows kept at Ibaraki Prefectural Animal Experiment Station were collected from 10 weeks prepartum to 20 weeks postpartum. Cows were assigned randomly to a soybean meal (S8M) diet or a fish meal (FM) diet from 4 weeks before expected calving date to 20 weeks postpartum. Each diet was formulated to contain similar amounts of CP, ADF, and NDF. In the FM diet, 2.5 and 5% of fish meal were supplemented as total mixed rations in prepartum and postpartum periods, respectively. Compared to the SBM diet, undegraded intake protein (UIP) and Met were higher in the FM diet, but Lys was low. Body weight and dry matter intake were not affected by supplemental FM, and dry matter intake increased by 6 weeks postpartum and maintained constant after 7 weeks postpartum. Cows in the FM diet remained high milk production during the experimental period, but milk yield in the SBM diet decreased gradually after 6 weeks postpartum. Supplemental FM increased milk yield and protein yield from 10 to 20 weeks postpartum when FM intake was 1.19 kg/d, although milk protein was not improved. There were no significance differences in fat content and fat yield between FM and SBM diets. Supplemental FM had no effect on plasma glucose and urea-N at parturition and 7 weeks postpartum. Thus, the increased milk and protein yield may be due to the combination of carryover effect of supplemental UIP or Met in FM from 4 weeks prepartum to 10 weeks postpartum and direct effect of supplemental FM.