• 제목/요약/키워드: 3D body data

검색결과 858건 처리시간 0.026초

차원 인체 스캔 데이터를 활용한 한국 중년여성 토르소 원형 설계 (Torso Pattern Design for Korean Middle-Aged Women using 3D Human Body Scan Data)

  • 김혜진;박순지
    • 한국의류산업학회지
    • /
    • 제13권4호
    • /
    • pp.600-613
    • /
    • 2011
  • The purpose of this study is to provide Torso pattern for Korean middle-aged women using 3D human body scan data. 155 women in their 40's or 50's were measured by Martin's anthropometry. Merging the data of 914 middle aged women provided by Korean agency for technology and standards, total of 1,069 subjects' data were analyzed. For data analysis, ANOVA, factor analysis and cluster analysis were done using SPSS PC+. And representative subject of each cluster was selected and they participated in 3D scanning and Torso pattern suggested for middle-aged women Torso pattern which investing the amount of ease according to each group for diffuse front interscye 30%, armscye circumference 30%, back interscye 40% using 3D human body scan data. The results of this study are as follows. Firstly, as a result of the factor analysis, the first factor was 'obesity index of body', The second factor was 'verticality size of body', The third factor was 'verticality length of upper bodice', The fourth factor was 'drop value to represent silhouette', and the fifth factor was 'physique of upper bodice'. And, middle-aged women type were classified 3 types according to the cluster analysis. Type 1(Y-type) was the long upper Torso with wide shoulder. Type 2(H-type) was flat-body type with comparatively thin upper bodice and thin lower bodice. And type 3(A-type) was the obese type with comparatively thin upper bodice and fat lower bodice. Secondly, using CAD program, point filtering was performed and approximated surface model was made. It used that generated surface smoothing corrected for abnormally extruded points and scattered points based on the curvature information. And 3D surfaces were flatted onto the plane by the internal tools of CAD program. Difference ratios of outline length and area between 3D curves and 2D plane were 0.42% and 0.54%, respectively. Third, wearing test by the sensory evaluation showed that distinct difference almost every category. The movement functionality test shows that, in all the tests which reveal significant differences, especially, 'comparison pattern A' experienced inconvenience to neck width and neck depth.

여자 7-18세 3D 모델을 위한 인체 사이즈 스펙 개발 (Size Specifications of Females Aged between 7 and 18 for 3D Body Model Development)

  • 최영림
    • 한국의류산업학회지
    • /
    • 제15권2호
    • /
    • pp.247-255
    • /
    • 2013
  • This study develops size sections and specifications for females 7-18 years old. The specifications will contribute to the development of precise virtual models that represent basic data for the size alteration of 3D virtual models. A total of 33 items from the $5^{th}$ Size Korea data set were adopted and analyzed. Two representative factors (Obesity and Height Factors) were identified through a factor analysis of the 33 items. Waist circumference and stature were selected as representative variables for Obesity and Height Factors, respectively, and conducted cross tabulations between waist circumference and height for the age groups of 7-12 and 13-18 year-olds. Size sections were developed for the development of 3D models based on the results. A regression analysis then developed size specifications for each section with independent variables of waist circumference and height as well as dependent variables of reference body size. Subsequently, Obesity Factors were better explained by waist circumference and Height Factors were better explained by stature. Finally, size specifications for each section were developed.

Analysis of Cross Sectional Ease Values for Fit Analysis from 3D Body Scan Data Taken in Working Positions

  • Nam, Jin-Hee;Branson, Donna H.;Ashdown, Susan P.;Cao, Huantian;Carnrite, Erica
    • International Journal of Human Ecology
    • /
    • 제12권1호
    • /
    • pp.87-99
    • /
    • 2011
  • Purpose- The purpose of this study was to compare the fit of two prototype liquid cooled vests using a 3D body scanner and accompanying software. The objectives of this study were to obtain quantitative measurements of ease values, and to use these data to evaluate the fit of two cooling vests in active positions and to develop methodological protocol to resolve alignment issues between the scans using software designed for the alignment of 3D objects. Design/methodology/approach- Garment treatments and body positions were two independent variables with three levels each. Quantitative dataset were dependent variables, and were manipulated in 3x3 factorial designs with repeated measures. Scan images from eight subjects were used and ease values were obtained to compare the fit. Two different types of analyses were conducted in order to compare the fit using t-test; those were radial mean distance value analysis and radial distance distribution rate analysis. Findings- Overall prototype II achieved a closer fit than prototype I with both analyses. These were consistent results with findings from a previous study that used a different approach for evaluation. Research limitations/implications- The main findings can be used as practical feedback for prototype modification/selection in the design process, making use of 3D body scanner as an evaluation tool. Originality/value- Methodological protocols that were devised to eliminate potential sources of errors can contribute to application of data from 3D body scanners.

3D 스캔데이터를 활용한 국내 남성용 스킨스쿠버복 패턴개발 (Development of the Men's Scuba Diving Suit Pattern by Using 3D Body-Scanned Data)

  • 최진희
    • 대한가정학회지
    • /
    • 제49권4호
    • /
    • pp.105-113
    • /
    • 2011
  • The purpose of this study was to develop the pattern of scuba diving suits for local men in their thirties by using 3D body-scanned data. It is widely acknowledged that draping method is more suitable than flat pattern for body shape as most scuba diving suits in the market are designed to fit the body tightly in a single piece with sleeves and legs. A dummy for this study was made based on men's standard clothing sizes in 30's which was derived from data of 2004 Size Korea. Accordingly, the basic body block was built upon through draping method. Next, a scuba diving suit was made from neoprene, followed by fit and the clothing pressure tests in order to evaluate the diving suit's functionality and comfort. The results of the fit test had high points of 4.33 in majority parts except armhole and crotch ones. In comparison of clothing pressure between wearer and dummy, the clothing pressure of wearer was indicated relatively low in most parts other than armhole and knee, resulting from cushion function of skin and muscle and high stretch of fabric.

3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구 (Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating)

  • 권석동;설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계 (Development of Men Slacks Pattern Using 3D Scan Data)

  • 손부현
    • 대한가정학회지
    • /
    • 제46권9호
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

Analysis of Body Characteristics of the US Women Aged from 26 to 45 Using 3D Body Scan Data

  • Kim, Dong-Eun
    • International Journal of Human Ecology
    • /
    • 제15권2호
    • /
    • pp.13-21
    • /
    • 2014
  • This study investigated the anthropometric characteristics of US women 26 to 45 years of age to classify their body shapes into different categories. Research data was obtained from 2950 women 26 to 45 years of age who participated in the SizeUSA study. A 26 to 35 years of age group and a 36 to 45 years of age group were selected from the data pool. A total of 26 measurements important for body shape classification and for apparel product development was used for the data analysis. Five factors accounted for the US women's body measurements. The body shapes of women were categorized into 4 types: Obese A-Shape, Overweight Y-Shape, Obese H-Shape, and Normal S-Shape. Normal S-Shape was the most common body shape type. More women in the 26 to 35 years of age group had Normal S-Shape type than women in the 36 to 45 years of age group. More women in the 36 to 45 years of age group had Obese A-Shape, Overweight Y-Shape, and Obese H-Shape than women in the 26 to 35 years of age group. Younger US women, 26 to 35 years of age had slimmer body sizes with more balanced body shapes; however, older US women, 36 to 45 years of age had larger body sizes with more various body shapes.

성인여성 버추얼 패션 3D 아바타와 Size Korea 인체형상의 형태 차이 비교 (A Comparative of the Different between Virtual Fashion 3D Avatar and Size Korea of Adult Women's Body Shapes)

  • 이예리;장정아
    • 한국의류산업학회지
    • /
    • 제22권1호
    • /
    • pp.87-93
    • /
    • 2020
  • This study provide basic data to develop a dress form reflecting body shape characteristics by age and to produce a 3D body form in a virtual fitting program. A comparative analysis was conducted on the size, section shape, and slope of side shape of the modeling form by the sizing of the basic female avatar in CLO 3D, one of the 3D apparel CAD programs and the body form of women in their 20s-50s by body shape in the 6th Size Korea (2010). First, all the differences were formed similarly in the direct measurements between the 3D avatar and the body form were within 1 mm. Second, in a comparison of the section form of the avatar and body form in Size Korea, the avatar was formed in straight body shape and did not reflect a spinal curvature according to age. As a result of an examination of the items with a difference over 5° in the slope of side shape, there were angle differences in numerous body shapes in the angles of the side upper abdomen, side upper back, and side upper bust, and the avatar's bust shape was expressed more flatly compared to body form. It will be possible to produce an avatar that can adequately reflect body shape characteristics by adding detailed length and angle items by the region like waist back length and front length in producing the avatar reflecting body shape characteristics, instead of a standard body shape.

대규모 인체치수조사 사업에서 3차원 측정치와 직접측정치의 차이 분석 -제8차 사이즈코리아 사업을 중심으로- (A Comprehensive Analysis of 3D Body Scanning vs. Manual Measurements in a Large-Scale Anthropometric Survey -Insights from the 8th Size Korea Project-)

  • 박선미
    • 한국의류학회지
    • /
    • 제48권2호
    • /
    • pp.233-253
    • /
    • 2024
  • This study analyzed differences between three-dimensional (3D) body scanning and manual measurements, aiming to assess whether 3D scanning can replace traditional anthropometric tools, such as tape measures and calipers. Data from 4,478 participants in the 8th Size Korea Project were analyzed, covering 43 measurement items. Since Given that the 3D and manual measurements were performed on the same subjects in the 8th Size Korea Project, it was possible to determine the correlation more accurately between the two measurement methods more accurately. Using Applying ISO 20685-1(2018) standards, 15 out of the 43 items fell within allowable error limits. When classified into six types, "small circumferences" and "segment lengths" showed averages of 3.35 mm and 3.10 mm, respectively, within acceptable range. "Body heights" and "body depths" slightly exceeded the limit, with averages of 5.28 mm and 6.58 mm. "Body widths" and "large circumferences" surpassed the limit, with means of 16.77 mm and 16.18 mm. The study offers an objective basis to for validate validating 3D measurements' measurements' reliability and accuracy, addressing various industries' needs for information on the human body's dimensions information.

Comparative study of turbulent flow around a bluff body by using two- and three-dimensional CFD

  • Ozdogan, Muhammet;Sungur, Bilal;Namli, Lutfu;Durmus, Aydin
    • Wind and Structures
    • /
    • 제25권6호
    • /
    • pp.537-549
    • /
    • 2017
  • In this study, the turbulent flow around a bluff body for different wind velocities was investigated numerically by using its two- and three-dimensional models. These models were tested to verify the validity of the simulation by being compared with experimental results which were taken from the literature. Variations of non-dimensional velocities in different positions according to the bluff body height were analysed and illustrated graphically. When the velocity distributions were examined, it was seen that the results of both two- and three-dimensional models agree with the experimental data. It was also seen that the velocities obtained from two-dimensional model matched up with the experimental data from the ground to the top of the bluff body. Particularly, compared to the front part of the bluff body, results of the upper and back part of the bluff body are better. Moreover, after comparing the results from calculations by using different models with experimental data, the effect of multidimensional models on the obtained results have been analysed for different inlet velocities. The calculation results from the two-dimensional (2D) model are in satisfactory agreement with the calculation results of the three-dimensional model (3D) for various flow situations when comparing with the experimental data from the literature even though the 3D model gives better solutions.