• Title/Summary/Keyword: 3D body data

Search Result 858, Processing Time 0.027 seconds

Alterations in hematological parameters in Republic of Korea Air Force pilots during altitude chamber flight (저압실 비행 훈련이 대한민국 공군 조종사의 혈액 성분에 미치는 영향)

  • Kim, Hyun-Soo;Jeon, Eun-Ryoung
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • An altitude chamber, also known as a hypobaric chamber, is a device used during aerospace or high terrestrial altitude research or training to simulate the effects of high altitude on the human body. Although data from altitude chamber researches using experimental animals have been accumulated, studies in the humans exposed to hypobaric conditions are seldomly reported. Despite the importance of altitude chamber flight training in the field of aviation physiology, the hematological analysis of post-flight physiological changes has rarely been performed. The aims of the present study were to investigate the alterations in blood components during altitude chamber flight and to determine whether the differences between pre- and post-flight values are significant. Sixty experienced pilots in the Republic of Korea Air Force were enrolled in the altitude chamber flight training. Venous blood samples were obtained before and immediately after the flight. Compared with the pre-flight values($6.32{\times}10^3/mm^3$, $5.02{\times}10^6/mm^3$, 15.61 g/dL, respectively), white blood cell count, red blood cell count and hemoglobin level were significantly increased after the flight($6.77{\times}10^3/mm^3$, $5.44{\times}10^6/mm^3$, 16.26 g/dL; p=0.006, p=0.012, p<0.001, respectively). These alterations may be attributable to the exposure to hypobaric hypoxia, 100% oxygen supply for denitrogenation, considerable rise and fall in altitude and psychophysical stress due to these factors. In further studies, experimental groups and methods should be individualized to ensure objectivity and diversification. In addition, multiple time-frame analyses regarding the changing pattern of each blood component are also required to elucidate the physiological process for adapting to the high terrestrial altitude exposure.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Noise-Robust Capturing and Animating Facial Expression by Using an Optical Motion Capture System (광학식 동작 포착 장비를 이용한 노이즈에 강건한 얼굴 애니메이션 제작)

  • Park, Sang-Il
    • Journal of Korea Game Society
    • /
    • v.10 no.5
    • /
    • pp.103-113
    • /
    • 2010
  • In this paper, we present a practical method for generating facial animation by using an optical motion capture system. In our setup, we assumed a situation of capturing the body motion and the facial expression simultaneously, which degrades the quality of the captured marker data. To overcome this problem, we provide an integrated framework based on the local coordinate system of each marker for labeling the marker data, hole-filling and removing noises. We justify the method by applying it to generate a short animated film.

Dynamic Response Measurement of the Head Arm Assembly of a Hard Disk Drive by Numerical Analysis and Experiments

  • Parlapalli, Madhusudhana R;Bin, Gu;Dongwei, Shu;Fujii, Yusaku
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.22-25
    • /
    • 2008
  • The dynamic response of the head arm assembly (HAA) of a hard disk drive to an impact load was obtained from a 3D non-linear finite element model using ANSYS/LS-DYNA and from experiments using a modified levitation mass method (LMM). In the finite element model, the impact load was created by modeling the mass as a rigid body and making it collide with the HAA. The velocity, displacement, acceleration, and inertial force of the mass were then obtained from the time history data of the finite element analysis. In the LMM, a mass that was levitated with an aerostatic linear bearing, and hence encountered negligible friction, was made to collide with the actuator arm, resulting in a dynamic bending test for the arm. During the collision, the Doppler frequency shift of the laser beam reflected from the mass was accurately measured with an optical interferometer. The velocity, displacement, acceleration, and inertial force of the mass were accurately calculated from the measured time-varying Doppler frequency shift. A good correlation between the experimental data and FEA results was observed. The FEA was also used to investigate the dynamic response of the HAA to impact by different masses.

'Mind the Mocking and don't Keep on Walking': Galaxy Mock Challenges for the Completed SDSS-IV Extended Baryon Oscillation Spectroscopic Survey

  • Moon, Jeongin;Choi, Peter D.;Rossi, Graziano
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.68.3-69
    • /
    • 2020
  • We develop a series of N-body data challenges, functional to the final analysis of the extended Baryon Oscillation Spectroscopic Survey (eBOSS) Data Release 16 (DR16) galaxy sample, primarily based on high-fidelity catalogs constructed from the Outer Rim simulation. We generate synthetic galaxy mocks by populating Outer Rim halos with a variety of halo occupation distribution (HOD) schemes of increasing complexity, spanning different redshift intervals. We then assess the performance of three complementary redshift space distortion (RSD) models in configuration and Fourier space, adopted for the analysis of the complete DR16 eBOSS sample of Luminous Red Galaxies (LRGs). We find that all the methods are mutually consistent, with comparable systematic errors on the Alcock-Paczynski parameters and the growth of structure, and robust to different HOD prescriptions - thus validating the robustness of the models and the pipelines used for the baryon acoustic oscillation (BAO) and full shape clustering analysis. Our study is relevant for the final eBOSS DR16 'consensus cosmology', as the systematic error budget is informed by testing the results of analyses against these high-resolution mocks. In addition, it is also useful for future large-volume surveys, since similar mock-making techniques and systematic corrections can be readily extended to model for instance the DESI galaxy sample.

  • PDF

Discrimination of Lateral Torso Types by Posture for Older Women (노년 여성의 몸통 측면 자세에 따른 체형 판별)

  • Sunmi Park;Hyunsook Han
    • Fashion & Textile Research Journal
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2024
  • This study aimed to objectively classify the lateral torso posture types and functions of older women. We used 3D body scan data of 119 women aged 70-85 years from the 6th SizeKorea project. First, we defined three torso axes to represent the lateral torso posture types: posterior waist-back, back-cervical, and whole torso axes. Next, we asked experts to select one of four lateral torso posture types-stooped, straight, leaning back, and swayback postures-by looking at the lateral photographic data of 119 older women. To identify the axis that best represented each lateral torso posture type, a discriminant analysis was conducted using the angle of each of the three torso axes as an independent variable and an expert's visual classification as a dependent variable. Based on the analysis, the whole torso and backcervical axis angles were selected as variables for judging lateral torso posture types. Subsequently, we developed a classification function to determine which of the four lateral torso posture types of a particular participant was applicable for a new individual. The method developed in this study is significant in that it enables the objective classification of the lateral torso postures types of older women.

A 43 kD Protein Isolated from the Herb Cajanus indicus L Attenuates Sodium Fluoride-induced Hepatic and Renal Disorders in Vivo

  • Manna, Prasenjit;Sinha, Mahua;Sil, Parames C.
    • BMB Reports
    • /
    • v.40 no.3
    • /
    • pp.382-395
    • /
    • 2007
  • The herb, Cajanus indicus L, is well known for its hepatoprotective action. A 43 kD protein has been isolated, purified and partially sequenced from the leaves of this herb. A number of in vivo and in vitro studies carried out in our laboratory suggest that this protein might be a major component responsible for the hepatoprotective action of the herb. Our successive studies have been designed to evaluate the potential efficacy of this protein in protecting the hepatic as well as renal tissues from the sodium fluoride (NaF) induced oxidative stress. The experimental groups of mice were exposed to NaF at a dose of 600 ppm through drinking water for one week. This exposure significantly altered the activities of the antioxidant enzymes like superoxide dismutase (SOD), catalase (CAT), glutathione-S-transferase (GST), glutathione reductase (GR) and the cellular metabolites such as reduced glutathione (GSH), oxidized glutathione (GSSG), total thiols, lipid peroxidation end products in liver and kidney compared to the normal mice. Intraperitoneal administration of the protein at a dose of 2 mg/kg body weight for seven days followed by NaF treatment (600 ppm for next seven days) normalized the activities of the hepato-renal antioxidant enzymes, the level of cellular metabolites and lipid peroxidation end products. Post treatment with the protein for four days showed that it could help recovering the damages after NaF administration. Time-course study suggests that the protein could stimulate the recovery of both the organs faster than natural process. Effects of a known antioxidant, vitamin E, and a non-relevant protein, bovine serum albumin (BSA) have been included in the study to validate the experimental data. Combining all, result suggests that NaF could induce severe oxidative stress both in the liver and kidney tissues in mice and the protein possessed the ability to attenuate that hepato-renal toxic effect of NaF probably via its antioxidant activity.

A prediction of Ring Frame Composite Properties Using Discretization Method (이산화 기법을 이용한 링프레임 복합재의 기계적 물성 예측)

  • Jeon, Yong Un;Kim, Yong Ha;Kim, Pyung Hwa;Kim, Hwi yeop;Park, Jung Sun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.939-941
    • /
    • 2017
  • The use of composites is increasing for lightweight aerospace structures. Among these structures, the ring frame and the parts of the projectile body are mainly made of a fiber reinforced composite material which is less susceptible such as delamination to structural damage. As the use of fiber reinforced composites increases, interest in modeling efficient methods of stiffness and strength is increasing. This paper predict the mechanical strength according to the repeating unit cell(RUC) of the 2-D triaxial braided composites of fiber reinforced composites. Yarn slice definition, incremental approach and stiffness reduction model were used as strength prediction. Finally, the results of strength prediction are verified by comparing with experimental data of 2-D triaxial braided composites specimens.

  • PDF

Kinematic Analysis of Marche Fente Motion in a Fleuret Attack Technique (펜싱 플러레 공격 기술중 마르쉬 팡트 동작의 운동학적 분석)

  • An, Sang-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.277-291
    • /
    • 2003
  • This study was designed to examine the kinematic factors in the phase during the marche fente motion. For this study, the subjects were 5 elite male fencing players. The direct linear transformation (DLT) method was used in calculating 3-D coordinate of the digitized body parts. The cubic spline function was used for smoothing and the kinematic data for displacement, velocity, angle variables were calculated for Kwon3d ver 2.1. And the following conclusions were drawn; 1. It show that the marche phase appeared to longer time than the pante phase In the performance time. For the fast attack, it showed that the subjects should be moving in a short stride width. 2. For a fast and stable movement posture in the marche phase, the vertical change of COG must be maintain the same position as possible, but all subjects appeared to decrease the COG because of a excessive the knee flection. 3. In the COG velocity change, all the subjects showed to the same change in both the marche and the fente phase. However in the attack extremity velocity, it increased velocity in order of upper arm, fore arm, and hand in the marche phase, but it showed different velocity among each subjects at the moment of stabbing. So that in order to do effective stabbing, they have to extend their upper extremity max and do faster the distal segment than the proximal segment. 4. It showed to take a fast and stable movement, because some subjects showed the big anteroposterior angle of the trunk flexed max shoulder angle and elbow angle of their attack arm and the other upper extremity.

Developmental Characteristics of Zophobas atratus (Coleoptera: Tenebrionidae) at Varing Temperatures (온도에 따른 아메리카왕거저리(Zophobas atratus)의 발육 특성)

  • Kwak, Kyu-Won;Kim, Sun Young;Lee, Kyeong Yong;Yoon, Hyung Joo
    • Korean journal of applied entomology
    • /
    • v.61 no.2
    • /
    • pp.357-368
    • /
    • 2022
  • We investigated the developmental characteristics of super mealworm (Coleoptera: Tenebrionidae) at four different temperatures (25℃, 27℃, 30℃, and 33℃). The rearing conditions were 9L/15D, 65% RH, and 1,330 to 1,800 lux with wheat bran. The length of developmental period of 1 to 18 instars at each temperature showed that 30℃ was the shortest at 120.0±5.8 days, compared to that at 27℃ (132.6±10.7 days), 33℃ (136.5±9.2 days), and 25℃ (156.7±7.5 days). The larval developmental period was statistically significantly longer at 25℃, 27℃, and 30℃ compared to the length at 33℃. However, the death rate of larvae at 33℃ was 2.7-3.3 times higher than the rate at other temperatures. Body weight was heaviest at 30℃ followed by 27℃, 33℃, and 25℃. The patterns of head capsule, body capsule, and body length were similar to that of body weight. Regression analyses of developmental period, larval body weight, and length according to temperature revealed 29-30℃ as the most suitable temperature. The prepupa rate was 43.1% in 17 instars, 30.3% in 18 instars, 15.4% in 16 instars, 7.1% in 19 instars, 2.2% in 15 instars, and 1.9% in 20 instars, accounting for 88.8% in 16-18 instars. Prepupal period was longer at lower temperatures. For the average prepupal period of 15-18 instars, prepupa time was 18.8±1.9 days at 27℃, 18.8±2.3 days at 30℃, 23.0±2.4 days at 33℃, and 23.1±2.9 days at 25℃. The average pupal period of females and males was 11.1±2.2 and 11.6±2.4 days, respectively. The data indicate that the most suitable rearing temperature of super mealworm was 30℃.