• 제목/요약/키워드: 3D body data

검색결과 852건 처리시간 0.026초

3차원 데이터를 활용하여 시니어를 대상으로 한 바디쉐이퍼의 보정기능성 평가 (Evaluation of Efficacy of Body Shaper for Senior Women Using 3D Scanned Data)

  • 김소영;홍경희;이희란
    • 한국의류산업학회지
    • /
    • 제21권2호
    • /
    • pp.220-230
    • /
    • 2019
  • The Fourth Industrial Revolution has increased studies on observing the cross section by overlapping the clothing worn using 3D human body data. However, there is a lack of studies on the effect of pressure clothing that contracts the shape of the human body. Therefore, this study objectively evaluated the shaping functionality of body shapers using 3D scan and 3D data. Two types of commercial body shapers were selected for this study. The nude body and body wearing body shapers were then scanned. A 3D program evaluated the shaping functionality by overlapping the nude state with the body wearing body shaper A and B respectively. As a result, it was found that the effect of body shapers could be adequately observed according to body parts. The smaller body shaper was shown to have superior shaping capability with the abdomen more affected. Analysis of the horizontal cross section indicated that the waist circumference decreased by 6 cm when wearing body shaper A and decreased by 12cm when wearing body shaper B. The volume of the waist part decreased by 8.6% when wearing body shaper A and by 20.4% when wearing body shaper B. Therefore, it is more effective to compare the objective shaping functionality by body parts using the overlapped 3D scanned data rather than using exterior evaluation or length measurement when wearing clothing that contracts the body shape.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • 대한인간공학회지
    • /
    • 제33권4호
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

A Study on Use of Anthropometric Data and 3D Body Scan Data at Apparel Industry

  • Chun, Jongsuk
    • The International Journal of Costume Culture
    • /
    • 제6권1호
    • /
    • pp.19-29
    • /
    • 2003
  • The 3D measurement data expected be useful to give appropriate garment fit and development of MTM(Made-to-Measure) CAD software. The researcher surveyed the need and use of national anthropometric data of the apparel industry. 17 Korean apparel manufacturers participated in the study. The need of anthropometric data at 5 different apparel business sectors was measured: men's suit, women's dress, casual-wear, underwear, and active sportswear. The result of the survey shows that height and bust, waist, hip circumferences are needed by all of the business sectors. The body measurements at the scye and upper arm area were need most by the men's suit manufacturers. The women's foundation garment manufacturers were well prepared for the use of the 3D body scan data and they expected the potential benefits of 3D body scan data would be great. The researcher also conducted a case study and found a pro and con of the using 3D body scan data for apparel product developing process. In the current stage of technical advance, a reasonable method was required to get nude like scan data for the women's foundation garment manufacturer. The researcher concluded that the apparel designer could use the 3D scan data for developing tremendous style garment design and pattern making.

  • PDF

풀바디 스캔과 모션 캡처를 활용한 3D 애니메이션 바디 프로필 (3D Animation Body Profiles from Full-body Scans and Motion Capture)

  • 송재원;전상욱;이수빈
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제29권3호
    • /
    • pp.59-67
    • /
    • 2023
  • 본 논문은 몸체 3D 스캔과 모션 캡처 장비를 활용한 3D 애니메이션 형태의 바디 프로필을 제안한다. 사용자는 미리 정해진 몇 개의 포즈에 대하여 3D 스캔을 수행함으로써 애니메이션 형태를 가진 자신만의 바디 프로필을 제작할 수 있다. 이를 위하여 일련의 포즈를 수행하는 템플릿 애니메이션을 모션 캡처를 통하여 획득하였고, 사용자로부터 획득된 3D 스캔 데이터를 애니메이션의 각 정점 포즈에 포즈 공간 디포머(Pose-space deformer)를 통하여 매핑시켰다. 이를 통하여 만들어진 3D 애니메이션 형태의 바디 프로필은 기존의 정적인 2D 이미지나 3D 스캔데이터보다 사용자에게 더 큰 만족도를 줄 수 있음을 확인할 수 있다.

동작시 3D 정보를 이용한 2D 패턴 전개 및 신축성 원단의 신장률을 고려한 사이클 팬츠 개발 (Development of 2D Patterns for Cycling Pants using 3D Data of Human Movement and Stretch Fabric)

  • 정연희;홍경희
    • 한국생활과학회지
    • /
    • 제19권3호
    • /
    • pp.555-563
    • /
    • 2010
  • With recent advances in 3D scanning technology, three-dimensional (3D) patternmaking is becoming a powerful way to develop garments pattern. This technology is now applicable to the made to measure (MTM) system of both ordinary and tightly fitting garments. Although the pattern of fitted clothing has been developed using 3D human data, it is still interesting to develop cycling pants by considering while-cycling body posture and fabric elasticity. This study adopted the Garland's triangle simplification method in order to simplify data without distorting the original 3D scan. Next, the Runge-Kutta method (2C-AN program) was used to develop a 2D pattern from the triangular pixels in the 3D scanned data. The 3D scanned data of four male, university students aged from 21 to 25, was obtained using Whole body scanner (Model WB4, Cyberware, Inc., USA). Results showed the average error of measurement was $4.58cm^2$ (0.19%) for area and 0~0.61cm for the length between the 3D body scanned data and the 2D developed pattern data. This is an acceptable range of error for garment manufacture. Additionally, the 2D pattern developed, based on the 3D body scanned data, did not need ease for comfort or ease of movement when cycling. This study thus provides insights into how garment patterns may be developed for ergonomic comfort in certain special environments.

3차원 인체스캔형상을 재현한 3D 아바타 제작을 위한 가상착의 시스템의 활용성 검증 -CLO 3D 프로그램을 중심으로- (Usability verification of virtual clothing system for the production of a 3D avatar reproduced from 3D human body scan shape data - Focusing on the CLO 3D program -)

  • 홍은희
    • 한국의상디자인학회지
    • /
    • 제22권1호
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study is to create a 3D avatar from 3D human body shape data using the CLO 3D virtual clothing program and to verify the feasibility of avatar production using the virtual clothing system for verifying size and shape. The research method was to select one virtual representative model that is the closest to the mean size of each body item for each age group. Using the 3D human body scan shape of a 40-69 years old male was applied to the CLO 3D virtual wearing system. Using the CLO 3D Avatar conversion menu, we verified the feasibility of creating a 3D avatar that reproduces the human body scan shape. In the dimension comparison between the 3D avatar and the fictitious representative model, the dimension difference was noticeable in height, circumference, and length. However, as a result, the converted 3D avatar showed less than a 5% difference in most human dimensions. In addition, since the body shape and posture were reproduced similarly, the utilization of the avatar was verified.

Standard Terminology System Referenced by 3D Human Body Model

  • Choi, Byung-Kwan;Lim, Ji-Hye
    • Journal of information and communication convergence engineering
    • /
    • 제17권2호
    • /
    • pp.91-96
    • /
    • 2019
  • In this study, a system to increase the expressiveness of existing standard terminology using three-dimensional (3D) data is designed. We analyze the existing medical terminology system by searching the reference literature and perform an expert group focus survey. A human body image is generated using a 3D modeling tool. Then, the anatomical position of the human body is mapped to the 3D coordinates' identification (ID) and metadata. We define the term to represent the 3D human body position in a total of 12 categories, including semantic terminology entity and semantic disorder. The Blender and 3ds Max programs are used to create the 3D model from medical imaging data. The generated 3D human body model is expressed by the ID of the coordinate type (x, y, and z axes) based on the anatomical position and mapped to the semantic entity including the meaning. We propose a system of standard terminology enabling integration and utilization of the 3D human body model, coordinates (ID), and metadata. In the future, through cooperation with the Electronic Health Record system, we will contribute to clinical research to generate higher-quality big data.

3차원 자동체형계측기 정밀도 검사 (An Accuracy Analysis of the 3D Automatic Body Measuring Machine)

  • 전수형;권석동;박세정;김정양;송정훈;김현진;김종원
    • 사상체질의학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF

K-SMPL: 한국인 체형 데이터 기반의 매개화된 인체 모델 (K-SMPL: Korean Body Measurement Data Based Parametric Human Model)

  • 최별이;이성희
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제28권4호
    • /
    • pp.1-11
    • /
    • 2022
  • 선형 스키닝 기반 3D 인체 생성 모델 SMPL (Skinned Multi-Person Linear Model)은 1990년대 미국 거주 미국인들 3천 8백여명을 대상으로 만들어진 3D 신체 데이터베이스인 CEASAR 로부터 최적화 기법을 통해 만들어진 가장 널리 쓰이는 통계적인 3D 모델이다. 본 연구는 한국인 체형의 통계적 특성을 보다 정확히 표현하는 SMPL기반의 한국인 체형 3D 모델을 제안한다. 이를 위해 우리는 한국인 여성 2천7백여명의 신체 각 부위의 실측 데이터에 기존 3D SMPL 모델을 피팅하는 비선형 최적화 알고리즘을 개발한다. 이를 사용하여 한국인 3D 신체 데이터베이스를 구축하고, 주성분 분석 방법으로 한국인 체형 기반 매개화된 3D 모델을 개발한다. 본 연구를 통해 제안하는 한국인의 체형적 특징을 가진 블렌드쉐입과 새로운 체형 파라미터는 기존 모델이 표현하는 체형에 비해 한국인 체형 데이터 특성을 잘 반영함을 확인하였다. 뿐만 아니라, 우리의 모델은 SMPL에 비해 신체 실측 데이터에 대한 피팅 정확도를 개선함을 확인하였다. 제안된 모델은 향후 아바타 생성이나 인체 형상 측정 등 다양한 용도로 사용될 수 있다.

성별 및 연령에 따른 3차원 인체측정에 대한 태도 비교 (Gender and Age Differences in Attitude toward 3-D Body Scanning)

  • 박재경;최경미;남윤자;이유리
    • 한국의류학회지
    • /
    • 제32권8호
    • /
    • pp.1244-1254
    • /
    • 2008
  • The purpose of this research is to compare the people’s attitude toward 3-D body scanning by their gender and age in order to provide the application of 3-D body scanning data for new services or products. This study collected questionnaire data from 442 Korean females and 258 Korean males who participated in the 3-D body scanning. The result of this study were as follows: 1. Most people had good feelings for 3-D body scanning. Male respondents were more dissatisfied than female, and teenagers had higher dissatisfaction rate than other age groups for the measurement garment. 2. 80.5% of all respondents had the intention for re-measurement of 3-D body scanning. Male respondents and teenagers had low intention for re-measurement. 3. For the use of 3-D body scanning data, 79.6% said "yes" for making avatar, and 88.3% agreed with the custom made clothes. There was no difference between gender and age for this question. The results of the study will demonstrate how clothing retailers and marketers can use the 3-D body scanning data.