• Title/Summary/Keyword: 3D Motion System

Search Result 793, Processing Time 0.036 seconds

Simplified Integral Imaging Pickup Method for Real Objects Using a Depth Camera

  • Li, Gang;Kwon, Ki-Chul;Shin, Gwan-Ho;Jeong, Ji-Seong;Yoo, Kwan-Hee;Kim, Nam
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.381-385
    • /
    • 2012
  • In this paper, we present a novel integral imaging pickup method. We extract each pixel's actual depth data from a real object's surface using a depth camera, then generate elemental images based on the depth map. Since the proposed method generates elemental images without a lens array, it has simplified the pickup process and overcome some disadvantages caused by a conventional optical pickup process using a lens array. As a result, we can display a three-dimensional (3D) image in integral imaging. To show the usefulness of the proposed method, an experiment is presented. Though the pickup process has been simplified in the proposed method, the experimental results reveal that it can also display a full motion parallax image the same as the image reconstructed by the conventional method. In addition, if we improve calculation speed, it will be useful in a real-time integral imaging display system.

The Estimation of Craniovertebral Angle using Wearable Sensor for Monitoring of Neck Posture in Real-Time (실시간 목 자세 모니터링을 위한 웨어러블 센서를 이용한 두개척추각 추정)

  • Lee, Jaehyun;Chee, Youngjoon
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.278-283
    • /
    • 2018
  • Nowdays, many people suffer from the neck pain due to forward head posture(FHP) and text neck(TN). To assess the severity of the FHP and TN the craniovertebral angle(CVA) is used in clinincs. However, it is difficult to monitor the neck posture using the CVA in daily life. We propose a new method using the cervical flexion angle(CFA) obtained from a wearable sensor to monitor neck posture in daily life. 15 participants were requested to pose FHP and TN. The CFA from the wearable sensor was compared with the CVA observed from a 3D motion camera system to analyze their correlation. The determination coefficients between CFA and CVA were 0.80 in TN and 0.57 in FHP, and 0.69 in TN and FHP. From the monitoring the neck posture while using laptop computer for 20 minutes, this wearable sensor can estimate the CVA with the mean squared error of 2.1 degree.

Numerical studies on non-linearity of added resistance and ship motions of KVLCC2 in short and long waves

  • Hizir, Olgun;Kim, Mingyu;Turan, Osman;Day, Alexander;Incecik, Atilla;Lee, Yongwon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, numerical simulations for the prediction of added resistance for KVLCC2 with varying wave steepness are performed using a Computational Fluid Dynamics (CFD) method and a 3-D linear potential method, and then the non-linearities of added resistance and ship motions are investigated in regular short and long waves. Firstly, grid convergence tests in short and long waves are carried out to establish an optimal mesh system for CFD simulations. Secondly, numerical simulations are performed to predict ship added resistance and vertical motion responses in short and long waves and the results are verified using the available experimental data. Finally, the non-linearities of added resistance and ship motions with unsteady wave patterns in the time domain are investigated with the increase in wave steepness in both short and long waves. The present systematic study demonstrates that the numerical results have a reasonable agreement with the experimental data and emphasizes the non-linearity in the prediction of the added resistance and the ship motions with the increasing wave steepness in short and long waves.

Development and performance evaluation of a low-cost custom-made extensional rheometer (저비용 수제 연신레오미터 개발 및 성능 평가)

  • Sihyun Kim;Hanbyeol Pak;Jeong-Hyun Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.110-118
    • /
    • 2023
  • Characterizing the extensional rheological properties of non-Newtonian fluids is crucial in many industrial processes, such as inkjet printing, injection molding, and fiber engineering. However, educational institutions and research laboratories with budget constraints have limited access to an expensive commercial extensional rheometer. In this study, we developed a custom-made extensional rheometer using a CO2 laser cutting machine and 3D printer. Furthermore, we utilized a smartphone with a low-cost microscopic lens for achieving a high spatial resolution of images. The aqueous polyethylene-oxide (PEO) solutions and a Boger fluid were prepared to characterize their extensional properties. A transition from a visco-capillary to an elasto-capillary regime was observed clearly through the developed rheometer. The extensional relaxation time and viscosity of the aqueous PEO solutions with a zero-shear viscosity of over 300 mPa·s could be quantified in the elasto-capillary regime. The extensional properties of the solutions with relatively small zero shear viscosity could be calculated using a smartphone's slow-motion feature with increasing temporal resolution of the images.

Polarimetry of Three Asteroids in Comet-Like Orbits (ACOs)

  • Geem, Jooyeon;Ishiguro, Masateru;Bach, Yoonsoo P.;Kuroda, Daisuke;Naito, Hiroyuki;Hanayama, Hidekazu;Kim, Yoonyoung;Kwon, Yuna G.;Jin, Sunho;Sekiguchi, Tomohiko;Okazaki, Ryo;Vaubaillon, Jeremie J.;Imai, Masataka;Ono, Tatsuharu;Futamuts, Yuki;Takagi, Seiko;Sato, Mitsuteru;Kuramoto, Kiyoshi;Watanabe, Makoto
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.65-65
    • /
    • 2019
  • Near-Earth objects consist of a mixture of bodies originated from outer solar system and main asteroidal belt, which are recognized as comets and near-Earth asteroids. In principal, they have orbits distinguishable by their orbital elements. It is, however, that some comets are recognized as asteroids because they could have lost the most of volatile materials in their subsurface layers. Due to their asteroidal appearances, it has been challenging to discriminate such dormant comets from a list of known asteroids. Here we propose to utilize polarimetric technique for finding such dormant comets. We thus conducted a polarimetric observations of three candidates of dormant comet nuclei, (331471) 1984 QY1, (3552) Don Quixote and (944) Hidalgo, by using the 1.6-m Pirka Telescope at the Nayoro observatory (operated by Hokkaido University, Japan). We selected these asteroids in comet-like orbits (ACOs) based on the orbital elements (i.e., the Tisserand parameter with respect to Jupiter TJ < 3). We found that 1984 QY1 has a polarimetric albedo (geometric albedo determined via polarimetry) pV = 0.16 +/- 0.06 while both Don Quixote and Hidalgo have Rc-band polarimetric albedos pR < 0.05. In accordance with the polarimetric result together with a dynamical analysis, we surmised that 1984 QY1 could be an S-type asteroid evolved into the current orbit via 3:1 mean motion resonance with Jupiter. On the contrary, the previous spectroscopic studies indicated that Don Quixote and Hidalgo are classified into D-type taxonomic group, which are typical of comet nuclei. In this presentation, we will introduce our polarimetric observations of ACOs and emphasize that polarimetry is powerful for discriminating the asteroidal and cometary origins.

  • PDF

GG Tauri A: gas properties and dynamics from the cavity to the outer disk

  • Nguyen, Thi Phuong;Dutrey, Anne;Pham, Ngoc Diep;Chapillon, Edwige;Guilloteau, Stephane;Lee, Chang Won;Di Folco, Emmanuel;Majumdar, Liton;Bary, Jeff;Beck, Tracy L.;Coutens, Audrey;Denis-Alpizar, Otoniel;Melisse, Jean-Paul;Pietu, Vincent;Stoecklin, Thierry;Tang, Yei-Wen
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.38.2-39
    • /
    • 2021
  • I will presents the analysis of the gas properties of the protoplanetary disk surrounding the young low-mass (about 1.2Msun) triple star, GG Tau A. This work makes use of ALMA observations of rotational lines of CO (12CO, 13CO and C18O) together NOEMA observations of a few dozens of other molecules. While the CO emission gives information on the molecular layer close to the disk atmosphere, its less abundant isotopologues 13CO and C18O bring information much deeper in the molecular layer. I will present the analysis of the morphology and kinematics of the gas disk using the CO isotopologues. A radiative transfer model of the ring in CO isotopologues will also be presented. The subtraction of this model from the original data reveals the weak emission of the molecular gas lying inside the cavity. Thus, I am able to evaluate the properties of the gas inside the cavity, such as the gas dynamics, excitation conditions, and the amount of mass in the cavity. High angular resolution observations of CO reveals sprials induced by embedded planet(s) located near the 3:2:1 mean-motion resonance that help to explain the special morphology of the circumbinary disk. I also discuss some chemical properties of the GG Tau A disk. I report the first detection of H2S and C2S in a protoplanetary disk. The molecule abundance relative to 13CO of about twenties other molecules will also be given. In GG Tau A, the detections of rare molecules such as H2S and C2S have been probably possible because the disk is more massive (a factor about 3-5) than other disks where the molecules was searched. Such a large disk mass makes the system suitable to detect rare molecules and to study cold-chemistry in protoplanetary disks.

  • PDF

Kinematics and Grip Forces of Professionals, Amateurs and Novices during Golf Putting (퍼팅 시 프로와 아마추어, 초보 골퍼사이의 운동학적 변인과 그립 악력 비교)

  • Choi, Jin-Seung;Kim, Hyung-Sik;Kang, Dong-Won;Kim, Han-Su;Oh, Ho-Sang;Seo, Jeong-Woo;Yi, Jeong-Han;Lim, Young-Tae;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.405-410
    • /
    • 2011
  • The purpose of this study was to compare the differences in kinematic variables and grip forces among professionals(PG), amateurs(AG), and novice group(NG) during golf putting. The participants consisted of 3 groups based on their playing ability: 8 professional golfers (handicap<5), 8 amateurs (handicap<18) and 8 novice. Each subject attempted 2.1m putts from the hole. 3D motion analysis system(Motion analysis Corp., USA) with 6 high speed cameras and grip force measurement system(Kim et al., 2007) were used to acquired kinematic and force data, respectively. To compare differences among groups, joint angles of upper limbs, trajectory and smoothness by jerk cost function(JC) of putter head and grip forces were used in this study. Results showed that there were significant differences among groups in most of variables such as joint angles, trajectory & smoothness of putter head, and distribution of grip force in both hands. In brief, we confirmed that putting stroke in PG was more accurate and smooth than that in other groups, especially NG, due to their well-controlled upper limbs and keeping grip forces constant in both hands. It can be concluded that due to skilled levels, fundamental differences of putting movement could be identified and these differences might be helpful for improving one's putting skills.

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

ANALYSIS ON GPS PWV EFFECTS AS AN INITIAL INPUT DATA OF NWP MODEL (수치예보모델 초기치로서 GPS 가강수량 영향 분석)

  • Lee, Jae-Won;Cho, Jung-Ho;Baek, Jeong-Ho;Park, Jong-Uk
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.285-296
    • /
    • 2007
  • The Precipitable Water Vapor (PWV) from GPS with high resolution in terms of time and space might reduce the limitations of the numerical weather prediction (NWP) model for easily variable phenomena, such as precipitation and cloud. We have converted to PWV from Global Positioning System (GPS) data of Korea Astronomy and Space Science Institute (KASI) and Ministry of Maritime Affairs & Fisheries (MOMAF). First of all, we have selected the heavy rainfall case of having a predictability limitation in time and space due to small-scale motion. In order to evaluate the effect for GPS PWV, we have executed the sensitivity experiment with PWV from GPS data over Korean peninsula in the Weather Research & Forecasting 3-Dimensional Variational (WRF-3DVAR). We have also suggested the direction of further research for an improvement of the predictability of NWP model on the basis of this case.

A Case Study of Tkatchev stretched Motion by Technical Feedback in Horizontal Bars (기술처치에 의한 철봉 Tkatchev stretched 동작의 사례연구)

  • Back, Jin-Ho;Son, Won-Il
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.77-87
    • /
    • 2008
  • This study is to formulate strategy for subject who are selected as national team in horizontal bars event in apparatus gymnastics. For this, skill training program was applied to players for 8 weeks. Then it was analyzed by using 3D motion Analysis system to seek the difference between before and after using the program. There were decisive demerit element K's first try for Tkatchev stretched movement from low elevation and crooked body while elevating. Not only, the location of his center of mass is far and low and there was some concern in his landing due to bended his hip-joint, but also, it exposed weak point in retro-action followed technique. Thus, to overcome that weak point, the subject repeated practices on following; when preparing for Tkatchev stretched movement at downward for big spin, make sure extend shoulder angle faster, make sure Tap movement is short and concise using hip-joint angular while delaying Tap timing for folding the body, and moreover, while backlashing the body, used shoulder joint angle wide to pull up the body. As a result, the speed of vertical upward did rut increase when separation from the bar. However, height of elevation increased that the leg would rut hit the horizontal bar even straight up the hip-joint. Therefore, the movement itself provided magnificent motion and even helped decrease the demerits.