• Title/Summary/Keyword: 3D Motion System

Search Result 793, Processing Time 0.027 seconds

The Effects of Hiking Poles-using on Gait and Muscle Activity (등산폴 사용이 보행과 근활동에 미치는 영향)

  • Seo, Jung-Suk;Kim, Yong-Woon;Yoon, Te-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.209-215
    • /
    • 2007
  • The purpose of this study was to investigate gait factor and muscle activity depending on hiking poles-using. Eight healthy men volunteered for this experiment. Each of them performed down-hill walking with hiking poles-using and without poles at speed of 3.5km/h for 45 minutes on a treadmill. The treadmill was set 25% down-hill inclination. Kinematic data collected in 60Hz were recorded and analyzed by using 2D motion capture system to measure step time and step length so on. And the lower extremity muscle activities were simultaneously recorded in 1500Hz and assessed by using EMG. The statistical analysis was the paired t-test with repeated measures to compare between hiking poles-using and without poles. The level of statistical significance for all tests was .05. The results of this study were following : Step time was showed statistically different according to pole conditions. That is, the case of poles-using was longer than without poles in step time. Also, step length was showed statistically different between two conditions. Step length about trials with poles was longer than trials without poles. In the muscle activity, the case of all muscles was not showed statistical significance about pole conditions. However, in most muscles IEMG, there were some decreasing-trend relatively when hiking polesusing.

A Method of Reusing Kinematic Information for Virtual Facilities (동작 정보를 갖는 가상설비 데이터 재활용 방법론)

  • Ko, Min-Suk;Shin, Hye-Seon;Wang, Gi-Nam;Park, Sang-Chul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.4
    • /
    • pp.305-313
    • /
    • 2011
  • This paper proposes a method for reusing kinematic design data for virtual facilities, Making a virtual model of a facility involves two major activities: geometric design (virtual model visualization) and kinematic design that should be remodeled frequently whenever design changes occur, Conventionally, a virtual model of an automated facility focuses on the design level, which mainly deals with design verification, alternative comparison, and geometric model diagnosis, Although a design level model can be designed with the information of past models from PLM system, a simulation level model is not sufficient utilized to be reused for kinematic design purpose, We propose a method for reusing kinematic information of a past simulation model to cope with this problem, We use the concept or the 'center of mass', which is a point representing the mean position of the matter in a body or system. And we also use comparison method of a boundary box to identity which 3D objects have to be involved from the design model to a link structure that is contained in the simulation model. Because a proposed method only use not a historical approach but a geometrical approach, it is more effective to apply to the field.

A Study on the Characteristics of Behavior of Tripod Mechanism in Swashplate Type Piston Motor (사판식 피스톤 모터의 트라이포드 기구의 거동 특성 연구)

  • Ham, Y.B.;Ha, J.H.;Park, K.M.;Kim, S.D.
    • Journal of Power System Engineering
    • /
    • v.6 no.3
    • /
    • pp.36-41
    • /
    • 2002
  • A swashplate type piston motor with a tripod joints is introduced to improve compactness and starting torque in conventional types of motor. If the driving torque of motor shaft is transmitted by utilizing the mechanism, its friction torque loss would be drastically reduced and mechanical efficiency would be improved because the lateral force on the piston of the rod type motor with tripod joints mechanism is relatively smaller than that of the conventional plunger type motor. In particular, kinematics analysis for the mechanism are done as a preliminary study to investigate the feasibility of the mechanism in the axial piston motor. General formulas are derived from the displacement and velocity analysis of the mechanism, showing relationships between output shaft and shoe holder motion. A series of numerical calculations are carried out for a medium size motor with 160cc/rev using the formulas and their graphical plots are shown as well.

  • PDF

Fatigue Strength Evaluation of Bogie Frame for Power Car (동력차용 대차프레임의 피로강도평가)

  • Lee, Hak-Ju;Han, Seung-U;Augagneur Sylvain;Lee, Sang-Rok
    • 연구논문집
    • /
    • s.27
    • /
    • pp.57-73
    • /
    • 1997
  • The bogie between the track and the railway vehicle body, is one of the most important component in railroad vehicle. Its effects on the safety of both passengers and vehicle itself, and on the overall performance of the vehicle such as riding quality, noise and vibration are critical. The bogie is mainly consisted of the bogie frame, suspensions, wheels and axles, braking system, and transmission system. The complex shapes of the bogie frame and the complicate loading condition (both static and dynamic) induced in real operation make it difficult to design the bogie frame fulfilling all the requirements. The complicated loads applied to the bogie frame are i) static load due to the weight of the vehicle and passengers, ii) quasi-static load due to the rolling in curves iii) dynamic load due to the relative motion between the track, bogie, and vehicle body. In designing the real bogie frame, fatigue analysis based on the above complicated loading conditions is a must. In this study, stress analysis of the bogie frame has been performed for the various loading conditions according to the UIC Code 6 15-4. Magnitudes of the stress amplitude and mean stress were estimated based on the stress analysis results to simulate the operating loads encountered in service. Fatigue strength of the bogie frame was evaluated by using the constant life diagram of the material. 3-D surface modelling, finite element meshing, and finite element analysis were performed by Pro-Engineer, MSC/PATRAN, and MSC/NASTRAN, respectively.

  • PDF

Novel optimal intensity measures for probabilistic seismic analysis of RC high-rise buildings with core

  • Pejovic, Jelena R.;Serdar, Nina N.;Pejovic, Radenko R.
    • Earthquakes and Structures
    • /
    • v.15 no.4
    • /
    • pp.443-452
    • /
    • 2018
  • In this paper the new intensity measures (IMs) for probabilistic seismic analysis of RC high-rise buildings with core wall structural system are proposed. The existing IMs are analysed and the new optimal ones are presented. The newly proposed IMs are based on the existing ones which: 1) comprise a wider range of frequency velocity spectrum content and 2) are defined as the integral along the velocity spectrum. In analysis characteristics of optimal IMs such as: efficiency, practicality, proficiency and sufficiency are considered. As prototype buildings, RC high-rise buildings with core wall structural system and with characteristic heights: 20-storey, 30-storey and 40-storey, are selected. The non-linear 3D models of the prototype buildings are constructed. 720 non-linear time-history analyses are conducted for 60 ground motion records with a wide range of magnitudes, distances to source and various soil types. Statistical processing of results and detailed regression analysis are performed and appropriate demand models which relate IMs to demand measures (DMs), are obtained. The conducted analysis has shown that the newly proposed IMs can efficiently predict the DMs with minimum dispersion and satisfactory practicality as compared to the other commonly used IMs (e.g., PGA and $S_a(T_1)$). The newly proposed IMs overcome difficulties in calculating of integral along the velocity spectrum and present adequate replacement for IMs which comprise a wider range of frequency velocity spectrum content.

Effect of Scapulothoracic Joint Movement and Resistance Training Intensity on Shoulder Complex Muscle Activation during Bench Press Exercise (벤치 프레스 운동 시 하중에 따른 어깨가슴관절의 움직임이 어깨복합체 근 활성도에 미치는 영향)

  • Kim, Yoon-Hwan;Lee, Ki-Kwang;Lee, Man-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.2
    • /
    • pp.141-148
    • /
    • 2013
  • The purpose of this study was to investigate the scapulothoracic joint movement between different weight bearing contributing to effective bench press exercise. Ten male subjects participated in this study. All subjects were tested on the flat bench press machine which modified weight (50% and 70% of 1RM) and subjects were performed two different conditions(none protraction condition and protraction condition). Weight bar height and vertical velocity, EMG activation was measured using 3D motion capture system and wireless EMG analysis system. As the results, none protraction condition showed that it is more concentrate better pectoralis major muscle activation than protraction condition and middle pectoralis major, anterior deltoid and triceps brachii was significant higher integrated EMG in 70% of 1RM condition. In conclusion, limited scapulothoracic joint movement was more effective activated pectoralis major muscle all the weight through, while we could not find that it was not affected integrated EMG on eight muslces related to shoulder complex between scapulothracic joint movement conditions.

Kinematic Analysis of Horse-Riding Posture According to Skill Levels during Rising Trot with JeJu-horse (제주마를 이용한 승마 경속보시 숙련도에 따른 기승자세의 운동학적 비교분석)

  • Oh, Woon-Yong;Ryew, Che-Cheong;Kim, Jin-Hyun;Hyun, Sung-Hyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.467-479
    • /
    • 2009
  • The purpose of this study was to present the quantitative data which riders can utilize teaching field by comparison analysis of kinematics according to skill level of rider during 2 strides rising trot with the JeJu's-Horse. Participated subjects was consisted of total 10 riders(unskilled: n=5, skilled: n=5). The method of experiment & analysis was based on 3D cinematography. Variables were consisted of temporal, linear & angular kinematics by each event & phase. The skilled assigned more ratio of elapsed time in air than support phase, had the less range of motion in up-down direction and more consistent velocity in lateral & forward direction and performed periodic up-down movement with alignment in vertical direction according to elapsing of phases. The skilled more flexed at elbow and extended backwardly according to elapsing of phases, while more flexed forwardly at hip & knee and plantarflexion at ankle. The skilled postured backward extension but the unskilled do forward flexion. That is, It was considered that the unskilled continued more unstable posture than the skilled during 2 strides in rising trot.

3D Visual Attention Model and its Application to No-reference Stereoscopic Video Quality Assessment (3차원 시각 주의 모델과 이를 이용한 무참조 스테레오스코픽 비디오 화질 측정 방법)

  • Kim, Donghyun;Sohn, Kwanghoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.110-122
    • /
    • 2014
  • As multimedia technologies develop, three-dimensional (3D) technologies are attracting increasing attention from researchers. In particular, video quality assessment (VQA) has become a critical issue in stereoscopic image/video processing applications. Furthermore, a human visual system (HVS) could play an important role in the measurement of stereoscopic video quality, yet existing VQA methods have done little to develop a HVS for stereoscopic video. We seek to amend this by proposing a 3D visual attention (3DVA) model which simulates the HVS for stereoscopic video by combining multiple perceptual stimuli such as depth, motion, color, intensity, and orientation contrast. We utilize this 3DVA model for pooling on significant regions of very poor video quality, and we propose no-reference (NR) stereoscopic VQA (SVQA) method. We validated the proposed SVQA method using subjective test scores from our results and those reported by others. Our approach yields high correlation with the measured mean opinion score (MOS) as well as consistent performance in asymmetric coding conditions. Additionally, the 3DVA model is used to extract information for the region-of-interest (ROI). Subjective evaluations of the extracted ROI indicate that the 3DVA-based ROI extraction outperforms the other compared extraction methods using spatial or/and temporal terms.

Semantic Virtual Environment Generation and Navigation Control for 3D Games (3차원 게임을 위한 시맨틱 가상환경 생성과 네비게이션 제어)

  • Jang, Hyun-Duk;Lee, Jae-Moon;Lee, Myeong-Won
    • The KIPS Transactions:PartA
    • /
    • v.14A no.4
    • /
    • pp.209-214
    • /
    • 2007
  • In conventional game systems, virtual environments usually have just the role of a background without the direct relationships for game characters. nev do not consider the semantics about virtual environments. In this paper, we develop a game navigation system that provides semantic information about virtual environments including geographical, historical or my other location-dependent information. Then, the game character obtains the geographical location and its related information when it navigates through a virtual environment. It can be an implementation method for a semantic virtual environment because it can have the environment maintain its semantics depending on the specific location. In addition, we describe a method that can control a character's motion in the semantic virtual environment interactively, and that can input specific information according to the location of the character.

Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현)

  • Kim, Dong-Hak;Kim, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF