• 제목/요약/키워드: 3D Image Acquisition

검색결과 247건 처리시간 0.024초

Design and Implementation of High-Resolution Integral Imaging Display System using Expanded Depth Image

  • Song, Min-Ho;Lim, Byung-Muk;Ryu, Ga-A;Ha, Jong-Sung;Yoo, Kwan-Hee
    • International Journal of Contents
    • /
    • 제14권3호
    • /
    • pp.1-6
    • /
    • 2018
  • For 3D display applications, auto-stereoscopic display methods that can provide 3D images without glasses have been actively developed. This paper is concerned with developing a display system for elemental images of real space using integral imaging. Unlike the conventional method, which reduces a color image to the level as much as a generated depth image does, we have minimized original color image data loss by generating an enlarged depth image with interpolation methods. Our method was efficiently implemented by applying a GPU parallel processing technique with OpenCL to rapidly generate a large amount of elemental image data. We also obtained experimental results for displaying higher quality integral imaging rather than one generated by previous methods.

구조화 조명과 영상 처리를 이용한 3차원 데이터 획득 시스템 (Three dimensional data acquisition system using structured light and image processing)

  • 전희성;박제홍;고문석
    • 전자공학회논문지S
    • /
    • 제35S권5호
    • /
    • pp.83-93
    • /
    • 1998
  • Three dimensional data acquisition system based on the structured light is developed in this work. The system is composed of a CCD camera, slide projector, and various image processing programs. Calibration procedures and several image processing steps which are necessary to get the rnage data are described. A new grid labeling technique and a grid pattern are devised to improve the accuracy of th eobtained data. Preliminary experimental result shows that the developed system may be used as a simple and cheap 3D data acquisition system. Severla suggestions are included for further research.

  • PDF

3차원 복원을 위한 구조적 조명 보정방법 (Hard calibration of a structured light for the Euclidian reconstruction)

  • 신동조;양성우;김재희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.183-186
    • /
    • 2003
  • A vision sensor should be calibrated prior to infer a Euclidian shape reconstruction. A point to point calibration. also referred to as a hard calibration, estimates calibration parameters by means of a set of 3D to 2D point pairs. We proposed a new method for determining a set of 3D to 2D pairs for the structured light hard calibration. It is simply determined based on epipolar geometry between camera image plane and projector plane, and a projector calibrating grid pattern. The projector calibration is divided two stages; world 3D data acquisition Stage and corresponding 2D data acquisition stage. After 3D data points are derived using cross ratio, corresponding 2D point in the projector plane can be determined by the fundamental matrix and horizontal grid ID of a projector calibrating pattern. Euclidian reconstruction can be achieved by linear triangulation. and experimental results from simulation are presented.

  • PDF

Representation Techniques for 4-Dimensional MR Images

  • Homma, Kazuhiro;Takenaka, Kenji;Nakai, Yoshihiko;Hirose, Takeshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.429-431
    • /
    • 2002
  • Metabolic analysis of biological tissues, the interventional radiology in MRT (Magnetic Resonance Treatment) and for clinical diagnoses, representation of 4-Dimensional (4D) structural information (x,y,z,t) of biological tissues is required. This paper discusses image representation techniques for those 4D MR Images. We have proposed an image reconstruction method for ultra-fast 3D MRI. It is based on image interpolation and prediction of un-acquired pictorial data in both of the real and the k-space (the acquisition domain in MRI). A 4D MR image is reconstructed from only two 3D MR images and acquired a few echo signals that are optimized by prediction of the tissue motion. This prediction can be done by the phase of acquired echo signal is proportioned to the tissue motion. On the other hand, reconstructed 4D MR images are represented as a 3D-movie by using computer graphics techniques. Rendered tissue surfaces and/or ROIs are displayed on a CRT monitor. It is represented in an arbitrary plane and/or rendered surface with their motion. As examples of the proposed representation techniques, the finger and the lung motion of healthy volunteers are demonstrated.

  • PDF

방송 및 모바일 실감형 2D/3D 컨텐츠 변환 방법 및 플랫폼 (2D/3D conversion algorithm on broadcast and mobile environment and the platform)

  • 송혁;배진우;유지상;최병호
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.386-389
    • /
    • 2007
  • TV technology started from black and white TV. Color TV invented and users request more realistic TV technology. The next technology is 3DTV. For 3DTV, 3D display technology, 3D coding technology, digital mux/demux technology in broadcast and 3D video acquisition are needed. Moreover, Almost every contents now exist are 2D contents. It causes necessity to convert from 2D to 3D. This article describes 2D/3D conversion algorithm and H/W platform on FPGA board. Time difference makes 3D effect and convolution filter increased the effect. Distorted image and original image give 3D effect. The algorithm is shown on 3D display. The display device shows 3D effect by parallax barrier method and has FPGA board.

  • PDF

경계 기반의 깊이 영상 개선 (The Enhancement of the Boundary-Based Depth Image)

  • 안양근;홍지만
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권4호
    • /
    • pp.51-58
    • /
    • 2012
  • 최근 깊이영상을 기반으로 한 3D 기술이 3D 공간감지, 3D 영상획득, 3D 인터랙션, 3D 게임 등 다양한 분야에서 응용되고 있다. 깊이영상을 생성하기 위해서는 깊이 카메라를 이용하게 되는데, 이렇게 생성된 깊이영상의 화질을 개선하기 위한 다양한 시도들이 이루어지고 있다. 본 눈문에서는 이러한 깊이 카메라 기반의 3D 응용에 있어서 깊이 영상을 개선하기 위해 영역기반의 에지 검출기를 사용하는 방법을 제안한다. 제안된 방법은 제한된 환경에서의 깊이영상을 획득하는 과정에서 발생 할 수 있는 화질열화를 후처리 또는 전처리를 통해 개선함으로써 보다 향상된 깊이 영상을 제공한다. 다양한 실험결과를 통해서 개선된 깊이영상을 객관적 화질 평가를 위해 가상시점 참조 소프트웨어에 적용하여 비교함으로써 최대 0.42dB의 화질 향상을 확인하였다. 또한 영상의 실제 시청 환경과 가장 유사한 방법인 DSCQS(Double Stimulus Continuous Quality Scale)방법을 통해서 주관적 화질의 객관적 평가를 수행함으로써 개선된 깊이영상의 효용성을 다시 확인하였다.

망막 두께 측정을 위한 망막 촬영 및 다채널 영상획득장치 개발 (Development of Retina Photographing and Multi Channel Image Acquisition System for Thickness Measurement of Retina)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.13-17
    • /
    • 2004
  • 망막 촬영 및 다채널 고속 영상 획득 시스템을 개발하였다. 망막 두께 측정은 망막을 3차원으로 촬영하고 고속으로 신호처리를 할 수 있는 시스템을 요구한다. 망막에 레이저를 투사한 후에 반사되어 돌아오는 레이저의 양을 array photo diode를 이용하여 감지하며 이를 3차원 영상화하여 망막의 두께를 측정할 수 있다. 망막에 레이저를 투사하는 장치, APD 광센서를 이용한 망막 영상화 장치, 다채널 고속 A/D 변환장치 및 PCI 인터페이스를 개발하였다. polygon mirror와 galvano mirror를 이용하여 HeNe 레이저 빔을 각각 수평방향과 수직방향으로 주사하여 이미지 평면을 만들어 망막에 투사하였다. APD 어레이 광센서를 이용하여 각 층별로 나타나는 망막영상을 획득하였으며, 이를 실시간으로 A/D 변환하여 PCI 버스를 통해 컴퓨터로 전송하였다.

  • PDF

CCD 영상획득 시스템에 의한 피사체의 변위 측정 (The Deflection Measurement of Objects by the CCD Image Acquisition System)

  • 강준묵;배연성;주영은;엄대용
    • 한국측량학회지
    • /
    • 제18권1호
    • /
    • pp.25-32
    • /
    • 2000
  • 최근 온라인 영상분석 시스템에 의한 수치영상의 정량적 분석에 관한 연구가 활발히 진행됨에 따라 교량 및 각종 구조물의 안정성 평가에 있어 수치영상의 환용이 모색되고 있다. 본 연구에서는 CDD 카메라로부터 획득된 영상을 이용하여 구조물의 변형을 효율적으로 해석하기 위해 동일시간대 입체영상 획득과 이를 일괄적으로 처리할 수 있는 시스템을 구축하고 콘크리트 하중재하시험을 실시하여 영상해석 정확도 및 공시체의 변위량을 도출하므로써 구축한 시스템에 대한 신뢰도 분석 및 활용가능성을 제시하고자 하였다.

  • PDF

Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method (The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method)

  • 최종숙;정우영;류재광
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.102-109
    • /
    • 2009
  • 목적 : Siemens사의 Flash 3D(Pixon(R) method, 3D OSEM)는 검사 시간을 단축하면서 재구성을 통해 영상의 질을 높일 수 있도록 개발된 소프트웨어 프로그램으로써 핵의학 단층 촬영 시 유용하게 적용되고 있는 영상처리기법이다. 그러나 감산된 영상을 Flash 3D로 재구성하여 시행하는 뇌 혈류 부하 검사 시에 영상 획득시간을 짧게 하여 검사를 시행하면 재구성된 감산 영상의 신호 대 잡음비가(SNR, signal to noise ratio) 기저 영상에 비해 낮아지는 문제점이 있었다. 감산 영상의 SNR을 높이기 위해 LEAP 검출기를 사용하였고, 뇌혈관의 해상력보다는 혈관 확장의 예민도에 더 중점을 두었다. 본 실험은 뇌혈관 부하 단층 촬영 시 LEAP 검출기의 적용 가능성을 확인하고, Flash 3D를 이용한 적정 수준의 재구성 매개 변수를 파악하는 데 목적이 있다. 실험재료 및 방법 : (1) 팬텀 평가: $^{99m}Tc$을 넣은 Hoffman 3D Brain $Phantom^{TM}$을 이용하였다. LEAP와 LEHR 검출기로 첫 번째 영상을(부하 영상에 해당) 획득하고 $^{99m}Tc$의 반감기인 6시간 후 동일한 방법으로 두 번째 영상을(기저 영상에 해당) 획득하였다. 또한, 각각의 기저 영상과 감산 영상의 SNR 및 백질과 회백질의 비를 측정하였다. (2) 환자 영상의 평가: 2008년 5월부터 2009년 1월까지 LEAP 검출기로 촬영하여 정상으로 판독된 15명과 LEHR 검출기로 촬영하여 정상으로 판독된 13명의 환자를 대상으로 영상을 정성분석 하였다. Phantom에서 얻은 재구성 매개 변수를 대입하여 평가하였다. 하루 검사 프로토콜로 시행하였으며 기저에서 925 MBq, 부하에서 925 MBq의 $^{99m}Tc$-ECD를 투여하였다. 결과 : (1) 팬텀 평가: 각 검출기에서 획득한 계수치를 측정한 결과 LEHR 기저에서는 41~46 kcount, 부하에서 79~90 kcount, 감산에서 40~47 kcount가 측정되었다. LEAP의 경우 기저에서 102~113 kcount, 부하에서 188~210 kcount, 감산에서 94~103 kcount가 측정되었다. LEHR 감산 영상의 SNR은 LEHR 기저 영상과 비교하면 37% 감소하여 나타났고, LEAP 감산 영상의 SNR은 LEAP 기저 영상과 비교하면 17% 감소하여 나타났다. 회백질과 백질의 비는 LEHR 기저에서 2.2:1 감산에서 1.9:1로 측정되었고, LEAP 기저에서는 2.4:1 감산에서 2:1로 측정되었다. (2) 환자 영상의 평가: LEHR 검출기로 획득한 계수는 기저에서 대략 40~60 kcount, 부하에서 80~100 kcount 사이였다. 기저 및 부하 영상은 FWHM을 7 mm로 (타 장비의 Cutoff에 해당), 감산 영상은 FWHM을 11 mm로 설정하는 것이 적절하였다. LEAP는 기저에서 대략 80~100 kcount, 부하에서 180~200 kcount로 측정되었다. LEAP 영상은 기저 및 부하에서 FWHM을 5 mm로, 감산에서 7 mm로 설정해야 영상의 흐림을 줄일 수 있었다. 기저 및 부하 영상은 LEHR 영상이 LEAP 영상보다 해상력이 우수했다. 그러나 감산 영상의 경우 팬텀 실험과 같이 LEHR 영상의 SNR이 떨어져 영상이 거칠게 보였다. 감산 영상은 LEAP 영상이 LEHR 영상에 비해 SNR 및 예민도가 높게 평가되었다. LEHR과 LEAP 검출기의 모든 영상에서 subset과 iteration은 8회가 적절하였다. 결론 : LEAP 검출기를 이용해 적정 수준의 필터를 사용함으로써 SNR을 높여 보다 선명한 감산 영상을 획득할 수 있게 되었다. 하루 검사 프로토콜을 적용하여 Flash 3D로 재구성하는 경우, 보다 나은 감산 영상을 얻기 위해 LEAP 검출기의 적용을 고려해 볼 수 있을 것으로 판단된다.

  • PDF