• 제목/요약/키워드: 3D FE Analysis

검색결과 582건 처리시간 0.035초

Magnetic charge를 이용한 Axial-gap 전동기의 특성해석 (Characteristic Analysis of Axial-gap Motor using Magnetic Charge)

  • 이상호;김도진;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.997-998
    • /
    • 2007
  • This paper deals with analytical solution concerning the image method using the magnetic charge instead of 3D FEA(finite element analysis) in the slotless single air-gap motor. The theory of analytical method and the design procedures are introduced. The reliability and validity of proposed analytical solution are verified through the comparison with the results of commercial 3D FE software. In addition, calculation time between proposed analytical solution and 3D FEA is compared. Finally, characteristics, such as Back-EMF and phase resistance, between calculated and experimental results are compared. From the verification with 3D FEA and experimental results, it is proved that presented analytical method provided very effective and precise results.

  • PDF

Synthesis and Characterization of Superparamagnetic Fe3O4@SiO2 Nanoparticles

  • Kulkarni, Sachnin A.;Sawadh, P.S.;Palei, Prakash K.
    • 대한화학회지
    • /
    • 제58권1호
    • /
    • pp.100-104
    • /
    • 2014
  • Magnetite nanoparticles were prepared by co-precipitation method and then silica was coated onto the surface of $Fe_3O_4$ by hydrolysis of TEOS. The silica coated magnetite nanoparticles were characterized for its structural, microstructural, optical, vibrational and magnetic properties by X-ray diffraction analysis, Scanning electron microscopy, UV-visible spectroscopy, Infrared spectroscopy and Vibration sample magnetometer, respectively. XRD study confirmed the presence of $SiO_2$ on the surface of magnetite nanoparticles. SEM study indicated that with increase in TEOS content the particles become bigger and mono-disperse. It was also found that the silica coating prevents magnetic particles from aggregation and imparts excellent stability.

Soil interaction effects on sloshing response of the elevated tanks

  • Livaoglu, Ramazan
    • Geomechanics and Engineering
    • /
    • 제5권4호
    • /
    • pp.283-297
    • /
    • 2013
  • The aim of this paper is to investigate how the soil-structure interaction affects sloshing response of the elevated tanks. For this purpose, the elevated tanks with two different types of supporting systems which are built on six different soil profiles are analyzed for both embedded and surface foundation cases. Thus, considering these six different profiles described in well-known earthquake codes as supporting medium, a series of transient analysis have been performed to assess the effect of both fluid sloshing and soil-structure interaction (SSI). Fluid-Elevated Tank-Soil/Foundation systems are modeled with the finite element (FE) technique. In these models fluid-structure interaction is taken into account by implementing Lagrangian fluid FE approximation into the general purpose structural analysis computer code ANSYS. A 3-D FE model with viscous boundary is used in the analyses of elevated tanks-soil/foundation interaction. Formed models are analyzed for embedment and no embedment cases. Finally results from analyses showed that the soil-structure interaction and the structural properties of supporting system for the elevated tanks affected the sloshing response of the fluid inside the vessel.

Numerical analysis of large stud shear connector embedded in HFRC

  • He, Yu Liang;Zhang, Chong;Wang, Li Chao;Yang, Ying;Xiang, Yi Qiang
    • Structural Engineering and Mechanics
    • /
    • 제80권5호
    • /
    • pp.595-608
    • /
    • 2021
  • To investigate the mechanical behavior of large stud shear connector embedded in hybrid fiber-reinforced concrete (HFRC), a refined 3D nonlinear finite element (FE) model incorporating the constitutive model of HFRC was developed using ANSYS. Firstly, the test results conducted by the authors (He et al. 2017) were used to validate FE model of push out tests. Secondly, a total of 27 specimens were analyzed with various parameters including fiber volume fractions of HFRC, diameter of studs and HFRC strength. Finally, an empirical equation considering the contribution of steel fiber (SF) and polypropylene fiber (PF) was recommended to estimate the ultimate capacity of large stud shear connector embedded in HFRC.

A Study of Hair Damage by Magic Straight Perm

  • Lim, Sun-Nye
    • Applied Microscopy
    • /
    • 제42권3호
    • /
    • pp.129-135
    • /
    • 2012
  • In this study, the changes in hair quality before and after Magic straight perm have been evaluated through a hair damage measurement method. For this, a healthy high school student's (age18 years) wavy hair was selected and permed on the left and right sides. Then, the changes caused by physical methods which were applied during the fl at iron-based Magic straight perm were evaluated based on the hair damage measurement method before and after the Magic straight perm. According to the protein release test after the Magic straight perm, 1.26% in average and 0.14% was observed in Cool Magic straight perm sample. In a field emission scanning electron microscopy (FE-SEM) test, saw teeth-shaped partial desquamation of cuticle cells and impurities were observed in the warm-treated hair sample. In atomic force microscope (AFM), line-profile is a method to represent roughness data on hair. According to analysis on 3-dimensional (3D) images, the hair with Cool Magic straight perm was lower than the hair with Warm Magic perm in terms of the color change of 3D images. In addition, vertical changes were observed in the hair with Cool Magic perm. As a result, irregular surface roughness was observed. This study proposed a method to minimize hair damage by cooling down the heat with the cool hair straightener as soon as the Warm Magic was finished.

Shear bond strength of zirconia to resin: The effects of specimen preparation and loading procedure

  • Chen, Bingzhuo;Yang, Lu;Lu, Zhicen;Meng, Hongliang;Wu, Xinyi;Chen, Chen;Xie, Haifeng
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.313-323
    • /
    • 2019
  • PURPOSE. Shear bond strength (SBS) test is the most commonly used method for evaluating resin bond strength of zirconia, but SBS results vary among different studies even when evaluating the same bonding strategy. The purpose of this study was to promote standardization of the SBS test in evaluating zirconia ceramic bonding and to investigate factors that may affect the SBS value of a zirconia/resin cement/composite resin bonding specimen. MATERIALS AND METHODS. The zirconia/resin cement/composite resin bonding specimens were used to simulate loading with a shear force by the three-dimensional finite element (3D FE) modeling, in which stress distribution under uniform/non-uniform load, and different resin cement thickness and different elastic modulus of resin composite were analyzed. In vitro SBS test was also performed to validate the results of 3D FE analysis. RESULTS. The loading flat width was an important affecting factor. 3D FE analysis also showed that differences in resin cement layer thickness and resin composite would lead to the variations of stress accumulation area. The SBS test result showed that the load for preparing a SBS specimen is negatively correlated with the resin cement thickness and positively correlated with SBS values. CONCLUSION. When preparing a SBS specimen for evaluating bond performance, the load flat width, the load applied during cementation, and the different composite resins used affect the SBS results and therefore should be standardized.

Irradiation enduced In-plane magnetization in Fe/MgO/Fe/Co multilayers

  • Singh, Jitendra Pal;Lim, Weon Cheol;Song, Jonghan;Kim, Jaeyeoul;Asokan, K.;Chae, Keun Hwa
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.188.1-188.1
    • /
    • 2015
  • For present investigation Fe/MgO/Fe/Co multilayer stack is grown on Si substrate using e-beam evaporation in ultrahigh vacuum. This stack is irradiated perpendicularly by 120 MeV $Ag^{8+}$ at different fluences ranging from $1{\times}10^{11}$ to $1{\times}10^{13}ions/cm^2$ in high vacuum using 15UD Pelletron Accelerator at Inter University Accelerator Centre, New Delhi. Magnetic measurements carried out on pre and post irradiated stacks show significant changes in the shape of perpendicular hysteresis which is relevant with previous observation of re-orientation of magnetic moment along the direction of ion trajectory. However increase in plane squareness may be due to the modification of interface structure of stacks. X-ray reflectivity measurements show onset of interface roughness and interface mixing. X-ray diffraction measurements carried out using synchrotron radiation shows amorphous nature of MgO and Co layer in the stack. Peak corresponding body centered Fe [JCPDS-06-0696] is observed in X-ray diffraction pattern of pre and post irradiated stacks. Peak broadening shows granular nature of Fe layer. Estimated crystallite size is $22{\pm}1nm$ for pre-irradiated stack. Crystallite size first increases with irradiation then decreases. Structural quality of these stacks was further studied using transmission electron microscopic measurements. Thickness from these measurements are 54, 36, 23, 58 and 3 nm respectively for MgO, Fe, MgO, Fe+Co and Au layers in the stack. These measurements envisage poor crystallinity of different layers. Interfaces are not clear which indicate mixing at interface. With increase fluence mixing and diffusion was increased in the stack. X-ray absorption spectroscopic measurements carried out on these stacks show changes of Fe valence state after irradiation along with change of O(2p)-metal (3d) hybridized state. Valence state change predicts oxide formation at interface which causes enhanced in-plane magnetization.

  • PDF

SUS 300계 스테인리스강의 표면특성에 관한 연구 (A Study on Surface Properties in SUS 300 base Stainless Steel)

  • 이경구;윤동주;기회봉;최답천;이도재
    • 열처리공학회지
    • /
    • 제12권1호
    • /
    • pp.31-39
    • /
    • 1999
  • In the present study, oxidation behavior of 304 and 316 stainless steels was investigated. After solution treatment, specimens were polished up to $1{\mu}m$ $Al_2O_3$ grade and then subjected to oxidation treatment in dry air. The range of temperature was used for oxidation treatment at $300^{\circ}C{\sim}500^{\circ}C$ and TEM was used for analyzing the components and structure of oxide film. Also, these results were compared with the results of ESCA and TG. According to the results of TEM analysis, it was found that Cr oxide film was formed on top of the surface after room temperature oxidation but amorphous Fe oxide was formed on top of the surface and polycrystalline $(Cr,Fe)_2O_3$ was formed below the amorphous Fe oxide layer after $500^{\circ}C$ oxidation treatment. The oxidized specimens at $500^{\circ}C$ showed that 316 stainless steel resists more strongly to grain and grain boundary oxidation than 304 stainless steel. These results suggested that Mo component resolved in 316 stainless steel matrix suppressed the formation of Cr carbide which may results in local Cr deplete area.

  • PDF

자유낙하충격조건에 있는 사용후핵연료 운반용기의 충격해석방법 연구 (Analysis Method on the Free Drop Impact Condition of Spent Nuclear Fuel Shipping Casks)

  • 이재형;이영신;류충현;나재연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.766-771
    • /
    • 2001
  • The package used to transport radioactive materials, which is called by cask, must be safe under normal and hypothetical accident conditions. These requirements for the cask design must be verified through test or finite element analysis. Since the cost for FE analysis is less than one for test. the verification by FE analysis is mainly used. But due to the complexity of mechanical behaviors. the results depends on how users apply the codes and it can cause severe errors during analysis. In this paper, finite element analysis is carried out for the 9 meters free drop and the puncture condition of the hypothetical accident conditions using LS-DYNA3D and ABAQUS/Explicit. We have investigated the analyzing technique for the free drop impact test of the cask and found several vulnerable cases to errors. The analyzed results were compared with each other. We have suggested a reliable and relatively simple analysis technique for the drop test of spent nuclear fuel casks.

  • PDF

Development of an Automation Tool for the Three-Dimensional Finite Element Analysis of Machine Tool Spindles

  • Choi, Jin-Woo
    • 한국생산제조학회지
    • /
    • 제24권2호
    • /
    • pp.166-171
    • /
    • 2015
  • In this study, an automation tool was developed for rapid evaluation of machine tool spindle designs with automated three-dimensional finite element analysis (3D FEA) using solid elements. The tool performs FEA with the minimum data of point coordinates to define the section of the spindle shaft and bearing positions. Using object-oriented programming techniques, the tool was implemented in the programming environment of a CAD system to make use of its objects. Its modules were constructed with the objects to generate the geometric model and then to convert it into the FE model of 3D solid elements at the workbenches of the CAD system using the point data. Graphic user interfaces were developed to allow users to interact with the tool. This tool is helpful for identification of a near optimal design of the spindle based on, for example, stiffness with multiple design changes and then FEAs.