• Title/Summary/Keyword: 3D FE

Search Result 1,570, Processing Time 0.029 seconds

Effect of Heat Stress on Minerals Concentration in Blood and Colostrum of Heifers Around Parturition

  • Toharmat, T.;Kume, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.298-303
    • /
    • 1997
  • Sixteen holstein heifers were employed to study the effect of thermal stress on rectal temperature and mineral status of heifers around parturition during hot and cool weather. During the hot weather, rectal temperatures of the heifers measured at 08:30 and 15:30 h from 7 d prepartum to parturition were higher than those during the cool weather. Blood hematocrit and hemoglobin were not significantly different between the hot and cool weather, but at 2 and 1 wk prepartum, those during the hot weather were higher. Plasma Ca, inorganic P and Fe of the heifers during the hot weather were higher than those during the cool weather, but plasma Mg and Zn and serum alkaline phosphatase during the hot weather were lower. Colostral protein and Mg of heifers at parturition during the hot weather were lower than those during the cool weather, but colostral Ca, P, Fe and Zn were not affected by the weather.

Multifield Variational Finite Element Sectional Analysis of Composite Beams

  • Dhadwal, Manoj Kumar;Jung, Sung Nam
    • Composites Research
    • /
    • v.30 no.6
    • /
    • pp.343-349
    • /
    • 2017
  • A multifield variational formulation is developed for the finite element (FE) cross-sectional analysis of composite beams. The cross-sectional warping displacements and sectional stresses are considered to be the primary variables through the application of Reissner's partially mixed principle. The warping displacements are modeled using generic FE shape functions with nonlinear distribution over the beam section. A generalized Timoshenko level stiffness matrix is derived which incorporates the effects of elastic couplings, transverse shear, and Poisson's deformations. The accuracy of the present analysis is validated for the stiffness constants and elastostatic responses of composite box beams which correlate well with the experimental data and other state-of-the-art approaches.

Lubrication Performance Analysis of Deep Straight Groove Seal (깊은 직선 홈 시일의 윤활 성능해석)

  • Lee An Sung;Kim Jun Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.193-200
    • /
    • 2003
  • In this study a general Galerkin FE formulation of the incompressible Reynolds equation is derived for lubrication analyses of noncontacting mechanical face seals. Then, the formulation is applied to analyze the flexibly mounted stator-type reactor coolant pump seals of local nuclear power plants, which have deep straight grooves or plane coning on their primary seal ring faces. Their various lubrication performances have been predicted. Results show that the analyzed deep straight groove seal should have a net coning of less than $0.6\;{\mu}m$ to satisfy the leakage limit. And for the same amount of equilibrium opening force the plane coning seal requires to have a 3 times higher dimensionless coning than the deep straight groove seal.

  • PDF

A Study on the Deformation Measurement of Backward Extrusion Dies using Strain Gauge (스트레인 게이지를 이용한 후방압출금형의 변형측정에 관한 연구)

  • Yeo, Hong-Tae;Song, Yo-Sun;Choi, Young;Heo, Kwan-Do
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.713-716
    • /
    • 2002
  • The dimensional accuracy of the cold forged products is strongly dependent on the elastic behavior of the die. The elastic deformation of the die is continuously changed during the process. Therefore, it is needed to measure the deformation of die. Strain gauges are used to measure the elastic strains in the die during cold backward extrusion process. The strain gauges are attached on the die surface and embedded at the interface between the die insert and the stress ring. In order to compare the results with the FE-analysis, the rigid-plastic FE-analysis of cold backward extrusion process using DEFORM-3D has been performed, and the analysis of elastic deformation of the die has been done by using ANSYS with non-linear contact.

  • PDF

Metallurgical Study of Iron Artifacts Yangju-Mountain Fortress (양주 대모산성 출토 철기유물의 금속학적 연구)

  • Lim, Sun-Ki;Kang, Dai-Ill;Moon, Whan-Suk;Park, Dong-Kyu;Kang, Sung-Goon
    • 보존과학연구
    • /
    • s.14
    • /
    • pp.1-34
    • /
    • 1993
  • 1. Metallurgical Properties of Iron artifacts excavated from Yangju-Mountain fortress were studied for the scientific conservation and metallurgical history of ancient Iron artifacts.2. Iron artifacts form Yangju-Mountain fortress were found to be the products of having well-established Carburizing and remelting technique in that period.3. These artifacts seem to be manufactured from very pure ores, because very pure ferrite structure and low impurity.4. Especially evidence of very suitable carburizing technic well-established and usealloying method of Fe-C system on purpose were found.5. Cast iron artifacts were found to be eutectic composition (4.31%) having lowestmelting point in Fe-C system.

  • PDF

Taguchi Parameter Design for the Fabrication Process of Anisotropic NdFeB Magnet by Single Stroke Hot Deformation

  • Ying Li;Kim, Y. B.;Wang, Lin-shan;Kim, M. J.;M. S. Song;J. H. Yang;D. S. Suhr;Kim, T. K;Kim, C. O.
    • Journal of Magnetics
    • /
    • v.5 no.3
    • /
    • pp.106-109
    • /
    • 2000
  • The single stroke hot deformation is a simple method fur the fabrication of anisotropic NdFeB magnets. In order to obtain the optimum conditions, Taguchi method of experimental design was applied in this work. The optimum conditions obtained on the basis of coercivity in Taguchi analysis was a little different from those of remanence and maximum energy Product. The contribution of each factor to magnetic Properties was calculated in detail.

  • PDF

Parametric Study on Bellows of Piping System Using Fuzzy Theory

  • Lee Yang-Chang;Lee Joon-Seong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.6 no.1
    • /
    • pp.58-63
    • /
    • 2006
  • This paper describes a novel automated analysis system for bellows of piping system. An automatic finite element (FE) mesh generation technique, which is based on the fuzzy theory and computational geometry technique, is incorporated into the system, together with one of commercial FE analysis codes and one of commercial solid modelers. In this system, a geometric model, i.e. an analysis model, is first defined using a commercial solid modelers for 3-D shell structures. Node is generated if its distance from existing node points is similar to the node spacing function at the point. The node spacing function is well controlled by the fuzzy knowledge processing. The Delaunay triangulation technique is introduced as a basic tool for element generation. The triangular elements are converted to quadrilateral elements. Practical performances of the present system are demonstrated through several analysis for bellows of piping system.

Low Temperature Magnetization and Spin Wave Excitations in Amorphous Fe67 Co18B14Si1

  • Yoo, Yong-Goo;Yu, Seong-Cho;Hans A. Graf
    • Journal of Magnetics
    • /
    • v.2 no.3
    • /
    • pp.72-75
    • /
    • 1997
  • The temperature dependent saturation magnetization curve of amorphous Fe67 Co18B14Si1, alloy was measured using a SQUID magnetometer and vibrating sample magnetometer from 5 K up to 800 K. Inelastic neutron neutron scattering measurements also have been used to study the long wavelength spin dynamics of this high Tc amorphous ferromagnetic alloy. The magnon dispersion curve exhibit the conventional quadratic relationship E = D (T) q2 + $\Delta$, typical of an iso=obtained from a low temperature magnetization curve, which was consistent with the value obtained from the analysis oif inelastic neutron scattering data after consideration of its temperature dependence.

  • PDF

A New Trend of In-situ Electron Microscopy with Ion and Electron Beam Nano-Fabrication

  • Furuya, Kazuo;Tanaka, Miyoko
    • Applied Microscopy
    • /
    • v.36 no.spc1
    • /
    • pp.25-33
    • /
    • 2006
  • Nanofabrication with finely focused ion and electron beams is reviewed, and position and size controlled fabrication of nano-metals and -semiconductors is demonstrated. A focused ion beam (FIB) interface attached to a column of 200keV transmission electron microscope (TEM) was developed. Parallel lines and dots arrays were patterned on GaAs, Si and $SiO_2$ substrates with a 25keV $Ga^+-FIB$ of 200nm beam diameter at room temperature. FIB nanofabrication to semiconductor specimens caused amorphization and Ga injection. For the electron beam induced chemical vapor deposition (EBI-CVD), we have discovered that nano-metal dots are formed depending upon the beam diameter and the exposure time when decomposable gases such as $W(CO)_6$ were introduced at the beam irradiated areas. The diameter of the dots was reduced to less than 2.0nm with the UHV-FE-TEM, while those were limited to about 15nm in diameter with the FE-SEM. Self-standing 3D nanostructures were also successfully fabricated.

Dynamic Characteristics of Lumbar Spine After Vertebroplasty (척추성형술 시술 후 요추의 동적 특성)

  • Kim S.H.;Ko S.K.;Chae S.W.;Park J.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.240-243
    • /
    • 2005
  • Osteoporosis, one of the age-related disease causes vertebra body fracture due to weakening trabecular bone and makes a substantial effect on load sharing among vertebras. Recently, vertebroplasty is one of the most popular treatment, as augmenting PMMA into vertebra. Biomechanical studies about vertebroplasty have been evaluated by several experiments or analysis under static loading but there has been no study on response under dynamic loading. This study included the FE analysis of patients who treated vertebroplasty under dynamic loading. For this study, 3-D FE model of lumbar spine(L1-L2) was modeled from CT scanning data and compared with experimental results in vitro in order to validate this model. Biomechanical behavior about each of normal person, osteoporotic patient and patient treated vertebroplasty for quantitative evaluations of vertebroplasty was compared and investigated.

  • PDF