• Title/Summary/Keyword: 3D FE

Search Result 1,570, Processing Time 0.035 seconds

A Study on the Piezoelectric Characteristic of P(VDF-TrFE) Copolymer Thin Film by Physical Vapor Deposition Method (진공증착법을 이용한 P(VDF-TrFE) 공중합체 박막의 압전특성에 관한 연구)

  • Park, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.220-225
    • /
    • 2008
  • In this research, the P(VDF-TrFE) copolymer thin films were prepared by the physical vapor deposition and studied to their piezoelectric properties. In the case of a specimen produced by varying the deposition temperature from $260^{\circ}C$ to $300^{\circ}C$, its piezoelectric coefficient($d_{33}$) increased from 32.3pC/N to 36.28pC/N, and piezoelectric voltage coefficient($g_{33}$) from $793{\times}10^{-3}V{\cdot}m/N$ to $910.5{\times}10^{-3}V{\cdot}m/N$. On the basis of these experimental results, we concluded that the P(VDF-TrFE) copolymer thin film prepared at $300^{\circ}C$ showed the optimum piezoelectric properties. At the deposition temperature of $320^{\circ}C$, its piezoelectric coefficient(d33) decreased 25.3 pC/N and piezoelectric voltage coefficient($g_{33}$) $680{\times}10^{-3}V{\cdot}m/N$.

Dynamic Magneto-mechanical Behavior of Magnetization-graded Ferromagnetic Materials

  • Chen, Lei;Wang, Yao
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.215-220
    • /
    • 2014
  • This study investigates the dynamic magneto-mechanical behavior of magnetization-graded ferromagnetic materials Terfenol-D/FeCuNbSiB (MF). We measure the dynamic magneto-mechanical properties as a function of the DC bias magnetic field ($H_{dc}$). Our experimental results show that these dynamic magneto-mechanical properties are strongly dependent on the DC bias magnetic field. Furthermore, the dynamic strain coefficient, electromechanical resonance frequency, Young's moduli, and mechanical quality factor of Terfenol-D/FeCuNbSiB are greater than those of Terfenol-D under a lower DC bias magnetic field. The dynamic strain coefficient increases by a factor of between one and three, under the same DC bias magnetic field. In particular, the dynamic strain coefficient of Terfenol-D/FeCuNbSiB at zero bias achieves 48.6 nm/A, which is about 3.05 times larger than that of Terfenol-D. These good performances indicate that magnetization-graded ferromagnetic materials show promise for application in magnetic sensors.

Influence of a Single Dose of Fe Dextran Administration with Organic Trace Mineral Supplementation on the Performance of Piglets

  • Acda, S.P.;Joo, J.W.;Kim, W.T.;Shim, Y.H.;Lee, S.H.;Chae, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.10
    • /
    • pp.1469-1474
    • /
    • 2002
  • This study was designed to evaluate the influence of a single or double dose of Fe dextran with organic trace mineral supplementation on the performance of piglets from dams fed diets with either inorganic (ITM) or organic trace minerals (OTM). It also determined the effect of the source of the trace minerals on the reproductive performance of sows. The trace mineral premixes were prepared using metal proteinates and the corresponding inorganic salts for the OTM and the ITM, respectively. Each mineral premix provided 100 ppm Fe/175 ppm Fe, 35 ppm Cu/170 ppm Cu, 90 ppm Zn/120 ppm Zn, and 40 ppm Mn/35 ppm Mn when added at 0.20% in sows /weaned pigs' diets, respectively. The first dose of Fe dextran was administered to piglets at 3 d and the second dose at 10 d after birth. One dose of Fe dextran supplied 100 mg of Fe. A total of 16 gestating sows (Landrace${\times}$Yorkshire) in parities 2 to 4 were randomly allocated to four treatments: 1) diet with ITM/one dose of Fe dextran to piglets, 2) diet with ITM/two doses of Fe dextran to piglets, 3) diet with OTM/one dose of Fe dextran to piglets, and 4) diet with OTM/two doses of Fe dextran to piglets. The total born alive, weaned, body weight at birth and at weaning were not affected by the sow's dietary treatment. Although organic trace mineral supplementation tended to increase the milk Fe content (p<0.10) at 7 d postpartum, piglets in all treatments performed equally from birth to weaning. The double doses of Fe dextran neither improved the average daily gain (ADG) nor influenced the survival of piglets from birth to weaning (21 d). Results suggest that a single dose of Fe dextran given to suckling pigs is adequate to sustain their needs for growth throughout the lactation period (21 d). Furthermore, there was a 21% improvement in both the ADG and the average daily feed intake (ADFI) (p<0.05) in weaned pigs fed diets with OTM. Cu and Fe in the liver (p<0.01), and Zn in both the bone (p<0.01) and the serum (p<0.01) were higher in piglets fed OTM than in those fed ITM. It would be concluded that single dose of Fe dextran administration with organic trace mineral supplementation show similar growth performance compared to 2 dose Fe dextran administration with inorganic mineral supplementation in young pigs.

Effect of $K_2$CO$_3$ on Dangerous Gas Sensing Characteristics of ${\gamma}$-Fe$_2$O$_3$ Sensor. (${\gamma}$-Fe$_2$O$_3$센서의 위험성 가스 감지 특성에 $K_2$CO$_3$가 미치는 영향)

  • 임병오;박영구
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.2
    • /
    • pp.32-39
    • /
    • 1990
  • The ${\gamma}$-Fe$_2$O$_3$ compounds were oxidized in the furance after gas detecting sensor made molding as the Fe$_3$O$_4$ the synthesized Fe$_3$O$_4$, by ferrous sulfate and sodium hydroxide. Their sensities on carbon monoxide, ethyl alcohol and L. P. G. were measured at various temperatures, respectively. And then their electrical resistivities, thermal properties (D.T.A. & T.G.A.), were examined about their having an effet on the gas-sensing in company with the effect of pure ${\gamma}$-Fe$_2$O$_3$ and the detecting sensor ${\gamma}$-Fe$_2$O$_3$, which reacts with $K_2$CO$_3$ in the hydrothermal coundition, and the electrical conductive mechanism was reflected simultaneously. It was observed that the electrical conductivities and response ratios showed highest value at the endothermic temperature part, 300~35$0^{\circ}C$ of D.T.A.―curve. Consequently, the response ratios and response times of the hydrothermal detecting sensor were higher than that of pure detecting sensor, the specific surface areas were the highest at the endothermic range of D.T.A.-curve. These response ratios of detecting sensor for $K_2$CO$_3$, process at hydrothermal condition on carbon monoxide appeared higher than that on ethyl alcohol and in case of L.P.G. last.

  • PDF

Plasma Concentrations of Fe, Cu, Mn, and Cr of Maternal and Umbilical Cord Blood during Pregnancy

  • Lee, Jong-Im;Lim, Hyeon-Sook;Cho, Young-Sook
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.3
    • /
    • pp.282-286
    • /
    • 2002
  • Anemia is prevalent among pregnant women in Korea, and Fe deficiency anemia is a major nutritional problem throughout the world. Because studies of Cu, Mn, and Cr levels excluding Fe are rare, we were interested in changes in the nutritional status of these trace minerals and their relationship to hematogenesis. Accordingly, we determined the changes in plasma Fe, Cu, Mn, and Cr concentrations of maternal and umbilical cord blood during pregnancy, and evaluated the relationships between them at different time points during pregnancy. A total of 81 women participated in the study: 26 subjects in the first trimester, 23 in the second, and 32 in the third trimester. Plasma Fe levels were lower significantly (p<0.05) in the third trimester. Plasma Cu level ($\mu\textrm{g}$/dL) in each trimester were 86.6$\pm$13.8, 111.6$\pm$27.9, and 114.0$\pm$29.7, respectively; with significant increases (p<0.()5) in the second and third trimester. Plasma Mn concentrations (pg/dL) in each trimester were 212.6$\pm$89.0, 234.0$\pm$140.0, and 240.3$\pm$166.0, respectively and tended to increase, though not significantly, as the pregnancies progressed. The plasma concentrations of Cr (pg/dL) in each trimester were 3.7$\pm$2.0, 3.1$\pm$1.0, and 2.4$\pm$1.2, respectively; and was significantly lower (p<0.05) in the third trimester. In umbilical cord blood, the plasma level of Fe was 194.8$\pm$74.6 $\mu\textrm{g}$/dL, Cu was 57.5$\pm$10.9 $\mu\textrm{g}$/dL, Mn was 482.4$\pm$111.1 pg/dL, and Cr was 9.3$\pm$2.8 pg/dL. Plasma concentrations of Fe, Cu, Mn, and Cr of cord blood were 300 %, 50 %, 200 %, and 370% as compared to those of maternal blood in the third trimester. These results suggest that an active transport mechanism for the transport of Fe, Mn, and Cr from mother to fetus may exist, whereas, for Cu, the placenta appears to have a blocking effect on the transport from mother to baby.

Magnetic Properties of Cr-Doped Inverse Spinel Fe3O4 Thin Films (Cr 치환된 역스피넬 Fe3O4 박막의 자기적 특성)

  • Lee, Hee-Jung;Choi, Seung-Li;Lee, Jung-Han;Kim, Kwang-Joo;Choi, Dong-Hyeok;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.51-54
    • /
    • 2007
  • By substituting Cr in inverse-spinel $Fe_3O_4,\;Cr_xFe_{3-x}O_4$ thin film samples were prepared by sol-gel spin-coating method and their structural electronic, and magnetic properties were analyzed. X-ray diffraction indicates that the lattice constant decrease with increasing Cr composition (x). This result can be explained in terms of occupation of octahedral sites by $Cr^{3+}$ ions with smaller ionic radius than that of $Fe^{3+}$ Vibrating sample magnetometry measurements on the samples at room temperature revealed that saturation magnetization ($M_s$) decrease by Cr substitution, explainable by comparing spin magnetic moment among the related transition-metal ions. A decrease of magnetoresistence effect with x was observed, similar to that of $M_s$. The coercivity of the $Cr_xFe_{3-x}O_4$ films was found to increase with x, attributed to the increase of magnetic anisotropy by the existence of octahedral $Cr^{3+}(d^3)$.

Mössbauer Study of Tb2Bi1GaxFe5-xO12(x=0, 1) (Tb2Bi1GaxFe5-xO12(x=0, 1)의 뫼스바우어 분광연구)

  • Park, Il-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.2
    • /
    • pp.67-70
    • /
    • 2008
  • $Tb_2Bi_1Ga_xFe_{5-x}O_{12}$(x=0, 1) fabricated by sol-gel and vacuum sealed annealing process. $Tb_2Bi_1Ga_xFe_{5-x}O_{12}$(x=0, 1) have been studied by x-ray diffraction(XRD), vibrating sample magnetometer, and $M\ddot{o}ssbauer$ spectroscopy. The crystal structures were found to be a cubic garnet structure with space group Ia3d. The determined lattice constants $a_0$ of x = 0, and 1 are $12.497\AA$, and $12.465\AA$, respectively. The distribution of gallium and iron in $Tb_2Bi_1Ga_xFe_{5-x}O_{12}$ is studied by Rietveld refinement. Based on Rietveld refinement results, the terbium and bismuth ions occupy the 24c site, iron ions occupy the 24d, l6a site, and nonmagmetic gallium ions occupy the 16a site. In order to verify the magnetic site occupancy of iron and gallium, we have taken $M\ddot{o}ssbauer$ spectra for $Tb_2Bi_1Ga_xFe_{5-x}O_{12}$(x=0, 1) at room temperature. From the results of $M\ddot{o}ssbauer$ spectra analysis, the absorption area ratios of Fe ions for $Tb_2Bi_1Fe_5O_{12}$ on 24d and 16a sites are 60.8 % and 39.2 %, respectively, and the absorption area ratios of Fe ions for $Tb_2Bi_1Fe_5O_{12}$ on 24d and 16a sites are 74.7 % and 25.3 %, respectively. It is noticeable that all of the nonmagnetic Ga atoms occupy the 16a site by vacuum annealing process.

Production of Iron Enriched Eggs of Laying Hens

  • Park, S.W.;Namkung, H.;Ahn, H.J.;Paik, I.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.12
    • /
    • pp.1725-1728
    • /
    • 2004
  • An experiment was conducted to investigate the efficiency of transfer of dietary iron sources to eggs of laying hens. Eighty ISA-Brown laying birds of 30 wk old were housed in 40 cages of 2 birds each. Eight birds in four cages were assigned to one of the following ten treatments: T1; control, T2; 100 ppm iron supplementation with iron-methionine chelate (Fe-Met-100), T3; Fe-Met- 200, T4; Fe-Met-300, T5; 100 ppm iron supplementation with iron sulfate ($FeSO_4$-100), T6; $FeSO_4$-200, T7; $FeSO_4$-300, T8; 100 ppm iron supplementation with Availa-$Fe^{(R)}$ (Availa-Fe-100), T9; Availa-Fe-200 and T10; Availa-Fe-300. Results of 40 d feeding trial showed that there were no consistent responses in laying performance by source and level of iron supplementation. However, eggshell strength and color were improved by Fe supplementation. Egg iron content was maximized at 10-15 days after feeding supplemental Fe. Fe- Met was the most effective source in enriching Fe of eggs followed by Availa-Fe and $FeSO_4$. Increasing supplementary Fe level more than 100 ppm was not effective in Fe-Met and Availa-Fe treatments. Average Fe enrichment of 18% was achieved after feeding Fe-Met-100 for 15 d. In conclusion, enrichment of Fe in egg could be effectively achieved by supplementation of Fe-Met-100 for 15 d.

The Study on Magnetioresistance in Fe[NiFe/Cu] Multilayers (Fe[NiFe/Cu] 다층박막의 자기저항 효과에 대한 연구)

  • 박병숙;백주열;이기암;현준원
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.258-262
    • /
    • 1996
  • We have investigated the changes in magnetoresistive characteristics, interfacial roughness, and preferred orientation with the Fe buffer layer thickness, annealing temperature, and the stacking number of layers variation in Fe/[NiFe/Cu] multilayers by using the 3-gun d.c. magnetron sputtering method. Intensity of the (200) orientation was increased with the increment of the Fe-buffer layer thickness. We found a maximum magnetoresistance ration of 4.7%, when the buffer layer thickness was 70$\AA$, and the field sensitivity also showed a maximum value at the same thickness. We varied the stacking number of multilayers with fixing the Fe buffer layer thickness of 70$\AA$. When the stacking number was 40 layers, maximum MR ratio(5.3%) was observed. With the variation of annealing temperature no change in the MR ratio was found beyond $300^{\circ}C$. But decrement of MR ratio was observed above $300^{\circ}C$. This decrement of the MR ratio was responsible for the increment of paramagnetic mixed layer caused by the diffusion of Cu layer and the change of antiferromagnetic coupling.

  • PDF

Effect of Fe Addition on Mechanical Properties and Microstructure of As-Extruded Hypereutectic Al-Si-Fe Alloy (Fe가 첨가된 과공정 Al-Si-Fe합금 압출재의 기계적특성 및 미세조직에 관한 연구)

  • Lee, S.D.;Kim, D.H.;Beck, A.R.;Lim, S.G.
    • Transactions of Materials Processing
    • /
    • v.28 no.3
    • /
    • pp.123-129
    • /
    • 2019
  • Hypereutectic Al-Si alloys have been widely utilized for wear-resistant components in the automotive industry. In order to expand the application of Hypereutectic Al-Si alloys, the addition of alloying elements forming a stable precipitate at high temperature is required. Thermally stable inter metallic compounds can be formed through the addition of transition elements such as Fe, Ni to Al alloys. However, the amount of transition element to be added to Al alloys is limited due to their low solid solubility. Also, hypereutectic Al-Si-Fe alloys form coarse primary Si phases and needle-shaped intermetallic compounds during solidification in the general casting processes. In this study, the effects of the destruction of Intermetallic compound and Si phase are investigated via hot extrusion. Both the microstructure and mechanical properties are discussed under different extrusion conditions.