• Title/Summary/Keyword: 3D Air Flow

Search Result 396, Processing Time 0.031 seconds

Effect of Temperature on Removal of Ammonia in the Ceramic Biofilter Inoculated with Earthworm Casts (지렁이 분변토를 접종한 세라믹 바이오필터의 암모니아 제거에 미치는 온도의 영향)

  • Cho, Kyung-Suk
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.39-46
    • /
    • 2000
  • Removal of ammonia using the porous ceramic biofilter inoculated with earthworm casts was characterized. By assuming a plug air flow in the biofilter and applying the Michaelis-Menten equation, the maximum removal rate of $NH_3$ was $280.7g-N{\cdot}m^{-3}{\cdot}h^{-1}$($18.0g-N{\cdot}kg^{-1}{\cdot}d^{-1}$) at $30^{\circ}C$. $NH_3$ removal rate was increased as temperature increases from $15^{\circ}C$ to $35^{\circ}C$. The maximum removal rate was $285.8g-N{\cdot}m^{-3}{\cdot}h^{-1}$($18.8g-N{\cdot}kg^{-1}{\cdot}d^{-1}$) at $35^{\circ}C$. At $15^{\circ}C$, the $NH_3$ removal rate was $122.8g-N{\cdot}m^{-3}{\cdot}h^{-1}$($8.1g-N{\cdot}kg^{-1}{\cdot}d^{-1}$). When 210 ppm $NH_3$ was supplied to the biofilter at space velocity of $220h^{-1}$, the removal efficiency of $NH_3$ at 15, 25, 30 and $35^{\circ}C$ was 80, 90, 95, and 96%, respectively. The removal rate of the ceramic biofilter was 3 to 15 times higher than other biofilters comparing the removal efficiency of $NH_3$ per unit volume of carrier. This result indicates that earthworm casts and porous ceramics are very good inoculum source and carrier, respectively, for the $NH_3$-degrading biofilter.

  • PDF

Investigations into the Cylinder Flow Stabilities with a Thin Film Attachment

  • Doh, Deog-Hee;Jo, Hyo-Je;Kwon, Seang-Yong;Kim, Hyoung-June;Cho, Gyeang-Rae;Shin, Byeong-Rog
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.957-965
    • /
    • 2011
  • The wakes of a cylindrical body have been investigated. The cylindrical body was attached with a thin film. The film is made of silicon with configurations of 50mm(W) ${\times}$ 150mm(L) ${\times}$ 0.3mm(T). The cylinder wakes have been measured with PIV experiments under the conditions with and without the thin film. The diameter of the installed cylinder body is 30mm and the Reynolds numbers are 2730, 6160 and 9750 with the diameter. The measurement system consists of an Ar-ion laser(6W), a high speed camera(1024 ${\times}$ 992 pixel, 500fps) and a host computer. FFT analyses have been carried out using the velocity vectors obtained by PIV measurements at the point X/D=1.52 and Z/D=0.52. For understanding the three-dimensional flow structures, a new Volumetric PTV(particle tracking velocimetry) has been constructed, in which the same four high-resolution cameras have been used. It has been verified that the flexible film suppresses or damps the vortices separated from the cylinder body, which makes the cylinder's wakes stable. With increase of Re numbers the intensity of the dominant frequency of the wakes become smaller.

Numerical Study on the Heat Transfer Enhancement of Trapezoidal Vortex Generator in a Rectangular Channel (사각채널에서 사다리꼴 와류발생기에 의한 열전달 촉진에 대한 수치해석)

  • Park, T.H.;Lee, S.R.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.852-857
    • /
    • 2018
  • Vortex Generators are used in heat exchanger to enhance the heat transfer of air side. 3-D numerical analysis is performed on heat transfer characteristics of a channel with trapezoidal vortex generator. We investigate the effects of vortex generators with two different inclined angles to flow direction which are forward and backward vortex generators. The thermal hydraulic performance such as Nu and pressure drop, is compared quantitatively. The results show that vortex generator enhances the heat transfer by developing boundary layers and secondary flow in the downstream. The downwash flow region corresponds to the maximum Nu, while the upwash flow region corresponds to Nu minimum. In the view of the heat transfer characteristics, FVG is better than BVG. However, when flow is turbulent as Re increases, the pressure drop for FVG is higher than that for BVG.

The Flame Stability and the Emission Characteristics of Turbulent Premixed Flat Burner (난류예혼합 플랫버너의 화염 안정성 및 배출가스 특성)

  • Lee, Y.H.;Lee, J.S.;Lee, D.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study is to conduct a survey of the flame stability range and the emission characteristics for the optimum design of turbulent premixed flat burner. For that, the flame stability range was selected by the direct photography of the flame. And the mean temperature and CO, HC, $CO_{2}\;and\;O_{2}$ concentration distributions by changing the excess air ratio were measured. As results of this study, the flame stability range turned out to be getting narrower as fuel flow was increased. The blue flame mode was more excellent than any other flame modes in the emission characteristics by excess air ratio change. And the emission characteristics by fuel flow change were best at fuel flow 1l/min. Also, we found combustion noise during experiment of flame stability range. It had nothing do with excess air ratio range.

  • PDF

Hydraulic Performance Analysis of Tangential Vortex Intakes with Compound Section by Three-Dimensional Numerical Simulation (3차원 수치모의에 의한 복단면 형상의 접선식 와류 유입구 수리 특성 분석)

  • Lee, Du Han;Rhee, Dong Sop;Kim, Myounghwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.506-514
    • /
    • 2014
  • Recently the interest about the vortex intakes are rapidly increased because of its performance to drain a plenty of collected storm water at a time. The tangential intake a kind of vortex intakes is very applicable because this type is very simple and little against other types, but it has a big weakness that the vortex flow is not been rarely created below the design discharge. In this study, the characteristics of a tangential intake and two kinds of a newly suggested compound section type intake are analyzed by the 3D numerical modeling based on theories about the control shift and free drainage condition. The analysis focused on the flow condition, flow surface formation, depth-discharge relation, area ratio of air core. Based on this study, the mild-sloped compound section type intake is the optimal, but steep-sloped compound section type is also the optional for the small design discharge.

Development of a nanoparticle multi-generator for assessment of inhalation hazard

  • Lee, Sung-Bae;Han, Jeong-Hee;Kim, Tae-Hyun;Cha, Hyo-Geun;Lim, Cheal-Hong
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.87-98
    • /
    • 2021
  • In this study, we developed the nanoparticle multi-generator by 3D printer fusion deposition modeling (FDM) method that can reliably generate and deliver nanoparticles at a constant concentration for inhalation risk assessment. A white ABS filament was used as the test material, and SMPS was used for concentration analysis such as particle size and particle distribution. In the case of particle size, the particle size was divided by 100 nm or less and 100 to 1,000 nm, and the number of particles concentration, mass concentration, median diameter of particles, geometric average particle diameter, etc were measured. The occurrence conditions were the extruder temperature, the extruding speed of the nozzle, and the air flow rate, and experiments were conducted according to the change of conditions including the manufacturer's standard conditions. In addition, the utility of inhalation risk assessment was reviewed through a stability maintenance experiment for 6 h. As a result of the experiment, the size of the nanoparticles increased as the discharger temperature increased, as the discharge speed of the nozzle increased, and as the air flow rate decreased. Also, a constant pattern was shown according to the conditions. Even when particles were generated for a long time (6 h), the concentration was kept constant without significant deviation. The distribution of the particles was approximately 80 % for particles of 60 nm to 260 nm, 1.7 % for 1 ㎛ or larger, 0.908 mg/㎥ for the mass concentration, 111 nm for MMAD and 2.10 for GSD. Most of the ABS particles were circular with a size of less than 10 nm, and these circular particles were aggregated to form a cluster of grape with a size of several tens to several hundred nm.

EFFECT OF VALVE TIMING AND LIFT ON FLOW AND MIXING CHARACTERISTICS OF A CAI ENGINE

  • Kim, J.N.;Kim, H.Y.;Yoon, S.S.;Sa, S.D.;Kim, W.T.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.687-696
    • /
    • 2007
  • To increase the reliability of auto-ignition in CAI engines, the thermodynamic properties of intake flow is often controlled using recycled exhaust gases, called internal EGR. Because of the internal EGR influence on the overall thermodynamic properties and mixing quality of the gases that affect the subsequent combustion behavior, optimizing the intake and exhaust valve timing for the EGR is important to achieve the reliable auto-ignition and high thermal efficiency. In the present study, fully 3D numerical simulations were carried out to predict the mixing characteristics and flow field inside the cylinder as a function of valve timing. The 3D unsteady Eulerian-Lagrangian two-phase model was used to account for the interaction between the intake air and remaining internal EGR during the under-lap operation while varying three major parameters: the intake valve(IV) and exhaust valve(EV) timings and intake valve lift(IVL). Computational results showed that the largest EVC retardation, as in A6, yielded the optimal mixing of both EGR and fuel. The IV timing had little effect on the mixing quality. However, the IV timing variation caused backflow from the cylinder to the intake port. With respect to reduction of heat loss due to backflow, the case in B6 was considered to present the optimal operating condition. With the variation of the intake valve lift, the A1 case yielded the minimum amount of backflow. The best mixing was delivered when the lift height was at a minimum of 2 mm.

Anthracite Oxygen Combustion Simulation in 0.1MWth Circulating Fluidized Bed (0.1 MWth 급 순환유동층에서의 무연탄 연소 전산유체역학 모사)

  • Go, Eun Sol;Kook, Jin Woo;Seo, Kwang Won;Seo, Su Been;Kim, Hyung Woo;Kang, Seo Yeong;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.417-428
    • /
    • 2021
  • The combustion characteristics of anthracite, which follow a complex process with low reactivity, must be considered through the dynamic behavior of circulating fluidized bed (CFB) boilers. In this study, computational fluid dynamics (CFD) simulation was performed to analyze the combustion characteristics of anthracite in a pilot scale 0.1 MWth Oxy-fuel circulating fluidized bed (Oxy-CFB) boiler. The 0.1MWth Oxy-CFB boiler is composed of combustor (0.15 m l.D., 10 m High), cyclone, return leg, and so on. To perform CFD analysis, a 3D simulation model reactor was designed and used. The anthracite used in the experiment has an average particle size of 1,070 ㎛ and a density of 2,326 kg/m3. The flow pattern of gas-solids inside the reactor according to the change of combustion environment from air combustion to oxygen combustion was investigated. At this time, it was found that the temperature distribution in air combustion and oxygen combustion showed a similar pattern, but the pressure distribution was lower in oxygen combustion. addition, since it has a higher CO2 concentration in oxygen combustion than in air combustion, it can be expected that carbon dioxide capture will take place actively. As a result, it was confirmed that this study can contribute to the optimized design and operation of a circulating fluidized bed reactor using anthracite.

Change of Chemical and Microbial Properties during Fermentation of Cotton Waste for Oyster Mushroom Cultivation (느타리 재배용 폐면 발효 중의 화학성 및 미생물 상의 변화)

  • Jhune, Chang-Sung;Jang, Kap-Yeul;Cho, Soo-Muk;Oh, Se-Jong;Park, Jung-Sik;Weon, Hang-Yeon
    • The Korean Journal of Mycology
    • /
    • v.32 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The changes of microflora and chemical characteristics during fermentation process of cotton waste for oyster mushroom cultivation were investigated with 5 l bench-scale reactors placed in an incubator at different temperatures ($40,\;50\;and\;60^{\circ}C$). Cotton waste was wetted to 70% moisture, and air flow rates to the substrate were 50, 100 and 300 cc/min. In processing of composting, the mesophilic bacterial population decreased sharply but thermophilic bacterial population increased. In case of fungi, both mesophilic and thermophilic population decreased. The daily $CO_2$ evolution showed little difference in all treatments, while $NH_3$ dropped sharply after 3 days. The desirable composting temperature and air flow based on the mycelial growth of oyster mushroom were $50^{\circ}C$ and 100 cc/min, respectively.

Analysis of Working Environment and Ventilation Efficiency in Pig House using Computational Fluid Dynamics (전산유체역학을 사용한 양돈장 내 작업환경 환기효율성 분석)

  • Oh, Byung-Wook;Lee, Seong-Won;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.85-95
    • /
    • 2019
  • The internal environment in pig house is closely related to the animal productivity. In addition, it is important to consider a working environment inside the pig house due to high gas and dust concentrations. The poor working environment inside the pig house can cause health problems including respiratory diseases. To analyze the working environment, it is important to evaluate the ventilation efficiency to effectively remove harmful gases and dust. The purpose of this study is to develop a 3D CFD model to analyze the working environment in the pig house. CFD model was validated by comparing air temperature distributions between CFD computed and field measured data. The average air flow rate at the pig height was 40.1 % lower than the working height when incoming air was concentrated on upper layer by the installed ventilation system on the experimental pig house. Using the validated CFD model, the regional ventilation efficiency was computed by the TGD(tracer gas decay) method at the pig and working heights. There was a difference of ventilation efficiency on 14 % between the air stagnated section and the rest sections. Stagnated gas concentration can be effected by animal and human health.