• Title/Summary/Keyword: 3D 재구성

Search Result 482, Processing Time 0.024 seconds

Reusable Multi-story 3D Animation (재구성이 가능한 멀티스토리 3D 애니메이션)

  • Kim, Sungrae;Kim, Ho Sung;Tak, Ji-young;Park, Ji-en;Lim, Sun-hyuk;Kim, Soosanna;Lee, Kyu-seon;Lee, Ji-hyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.238-242
    • /
    • 2007
  • The existent UCC sites display only finalized contents by publisher. It dose not provide any platform for resources of UCC that public users could reorganize. This paper has developed a platform to be able to produce reusable content using the scenes of the contents and produced a 3D animation with multiple story. It is necessary for user to search the provided contents for easy reorganization of the contents. The scene is classified by the description and information of the scene for handy search. It is obscure for a movie clip to be represent with only one word. Therefore, the proposed platform provides the search technique with a overlapping choice for the specific categories that include most of elements for the scene. Then the user can choose a specific range of the selected movie clip, make a new story with reorganizing the order, and put a caption or BGM on the movie clip. The complete movie clip has the search preferences as a category, new clips, and top favorites. With the Multi-Story line concept, we made a 3D animation about episodes of thermal dolls in the Doll World. This attempt will come to the new marketing way for a field of the visual media like as Music Video, Drama, Feature Film, Commercial Film.

  • PDF

3D Reconstruction of Tissue from a few of MRI Images using Radial Basis Function (BBF를 이용한 적은 수의 MRI 이미지로부터 3차원 조직 재구성)

  • Shin, Young-Seok;Kim, Hyoung-Seok B.
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2077-2082
    • /
    • 2008
  • Recent the advanced technologies in medical imaging such as magnetic resonance imaging (MRI) and computed tomography (CT) make doctors improve the diagnostic skill with detailed anatomical information. In general, it is necessary to get a number of MRI images in order to obtain more detail information. However, the performance of MRI machines of privately run hospitals is not good and thus we may obtain only a few of MRI images. If 3D surface reconstruction is accomplished with a few slices, then it generates 3D surface of poor qualify. This paper propose a way to Set a 3D surface of high quality from a few of number of slices. First of all, our algorithm detects the boundary of tissues which we want to reconstruct as a 3D object and find out the set of vortices on the boundary. And then we generate a 3D implicit surface to interpolate the boundary points by using radial basis function. Lastly, we render the 3D implicit surface by using Marching cube algorithms.

Quadruple Polarized Antenna System with a Reconfigurable Feeding Network (재구성 급전 구조를 갖는 4중 편파 안테나 시스템)

  • Lee, Wang-Sang;Lee, Dong-Jin;Tae, Hyun-Sung;Park, Donghoon;Oh, Kyoung-Sub;Lee, Moon-Que;Yu, Jong-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2013
  • In this paper, quadruple polarized antenna system with a reconfigurable feeding network is presented. The proposed antenna system consists of the reconfigurable feeding network for fourth polarization such as vertical/horizontal linear polarization and right-handed/left-handed circular polarizations or 45 degree tilted vertical/horizontal linear polarization and patch antenna to receive the signals with various polarizations. In order to receive a signal in any direction, the proposed antenna is designed by electrical switches for reconfigurable polarization. The insertion loss of the designed feeding network in the proposed antenna system is approximately 1.2 dB. The measured 3 dB axial bandwidth and gain of the proposed antenna are about 2 % and 4 dBi(c).

Design of Reconfigurable Dual Polarization Patch Array Antenna (재구성 이중편파 패치 배열 안테나 설계)

  • Won Jun Lee;Young Jik Cha
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.463-468
    • /
    • 2023
  • In this paper, we proposed reconfigurable dual polarization patch array antenna that can select two polarizations(Vertical, RHCP) using defected ground structure and Pin diode. The proposed antenna was designed arranging a circular polarization patch antenna implemented with a square microstrip patch and two slots 3x3 at 25.8mm placed, a half-wavelength of 5.8 GHz. Conect the pin diode and the capacitor to the slot diagonally placed on the ground of each antennas, and select polarization using the open/short operating according to the application of DC voltage to the pin diode. As a result of the design, the gain of the antenna is 11.7 dBi at vertical polarization and 11.6 dBic at RHCP. The axial ratio is 20.3 dB at 1.8 dB vertical polarization at RHCP. Mutual Coupling is Maximum to -20.8 dB for vertical polarization and Maximum to -30.1 dB for RHCP.

A Study on Efficient Storage Method for High Density Raster Data (고밀도 격자자료의 효율적 저장기법 연구)

  • JunJang, Young-Woon;Choi, Yun-Woong;Lee, Hyo-Jong;Cho, Gi-Sung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.3
    • /
    • pp.401-408
    • /
    • 2009
  • A study for 3D-reconstruction and providing the geospatial information is in progress to many fields recently. For efficient providing the geospatial information, the present information has to be updated and be revised and then the latest geospatial information needs to be acquired economically. Especially, LiDAR system utilized in many study has a advantage to collect the 3D spacial data easily and densely that is possible to supply to the geospatial information. The 3D data of LiDAR is very suitable as a data for presenting 3D space, but in case of using the data without converting, the high performance processor is needed for presenting 2D forms from point data composed by 3D data. In comparison, basically the raster data structure of 2D form is more efficient than vector structure in cheap devices because of a simple structure and process speed. The purpose of this study, in case of supplying LiDAR data as 3D data, present the method that reconstructs to 2D raster data and convert to compression data applied by th tree construction in detail.

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings (CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상)

  • Kweon, Dae-Cheol;Jang, Keun-Jo;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2007
  • Contrast media may cause tissue injury by extravasation during intravenous automated injection during CT examination. Here, we present a study in which contrast media extravasation was detected and localized in the neck and thorax by three-dimensional(3D) CT data reformation. The CT studies of the extavasation site were performed using a 3D software program with four different display techniques axial, multi planar reformation(MPR), maximum intensity projection(MIP), and volume rendering displays are currently available for reconstructing MDCT data. 3D image reconstructions provide accurate views of high-resolution imaging. This paper introduces extravasation with the MDCT and 3D reformation findings of contrast media extravasation in neck ant thorax. The followed injection of the external jugular vein into an existing intravenous catheter and a large volume of extravasation was demonstrated on by 3D MDCT.

  • PDF

SoC Implementation of Deblocking Filter for Block-based Compressed Images and Videos (블록 기반 압축 이미지 및 비디오를 위한 디블로킹 필터의 SoC 구현)

  • Seo, Gwang-Seok;Lee, Joo-Heung
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.925-933
    • /
    • 2019
  • In this paper, we implement ZYNQ SoC-based post-processing system that utilizes partial reconfiguration to remove blocking artifacts generated by compression algorithm. Hardware implementation of the deblocking filter in a Field Programmable Gate Array (FPGA) provides high computational capability and can be partially reconfigured to process 1080p images in real time. Partially reconfigurable areas in FPGA can be utilized to use hardware more efficiently in highly resource-constrained embedded systems. Experimental results of the proposed system show improvement of visual quality both objectively and subjectively with 0.6dB higher PSNR after deblocking filtering process. The measured power consumption of the deblocking filter during run-time is 68.33mW.

A Study on 3d Reconstruction and Simulated Implantation of Human Femur Using Consecutive CT-Images (연속된 CT-Image를 이용한 고관절 3d 형상의 재구성 및 Simulated Implantation System 구축에 관한 연구)

  • 민경준;김중규;최재봉;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.155-164
    • /
    • 1999
  • In this paper, the prototype of SIS(Simulated Implantation System) for human femoral head is introduced. SIS is a software which carries on a virtual femoral head replacement surgery including 3d visualization as well as various numeric analyses between a patient's femur and artificial femur through certain stages of the image processing and of the computer graphics. Also, processes required after acquiring consecutive CT-images and projected image of an artificial femur are discussed, and the corresponding results including prototype of SIS are given.

  • PDF