• Title/Summary/Keyword: 3D 이미지 분할

Search Result 62, Processing Time 0.022 seconds

A Study on Audio-Visual Expression of Biometric Data Based on the Polysomnography Test (수면다원검사에 기반한 생체데이터 시청각화 연구)

  • Kim, Hee Soo;Oh, Na Yea;Park, Jin Wan
    • Korea Science and Art Forum
    • /
    • v.35
    • /
    • pp.145-155
    • /
    • 2018
  • The goal of the study is to provide a new type of audio-visualization method through case analysis and work production based on Polysomnography(PSG) data that is difficult to interpret or not familiar to the public. Most art works are produced with conscious actions during waking hours. On the other hand, during sleep, we get into the world of unconsciousness. Therefore, through the experiment, want to discover if could get something new when we were in the subconscious state, and if so, wondered what kind of art could be made through it. The study method is to consider definition of sleep and sleep data first. The sleep data were classified into normal group and Narcolepsy, Insomnia, and sleep apnea by focusing on sleep disorder graphs that is measured by sleep polygraph. After that, I refined and converted the acquired biometric data into a text-based script. The degree of sleep in the text form of the script was rendered as a 3D animated image using Maya. In addition, the heart rate data script was transformed into a midi format, and the audition was implemented in the garage band. After Effects combines the image and sound to create four single channel images of 3 minutes and 20 seconds each. As a result of the research, I made an opportunity for anyone easy to understand the results, having difference with the normal data, through art instead of using difficult medical term. It also showed the possibility of artistic expression even when conscious actions did not occur. Through the results of this research, I expect the expansion and diversity of artistic audiovisual expression of biometric data.

A Study on the automatic vehicle monitoring system based on computer vision technology (컴퓨터 비전 기술을 기반으로 한 자동 차량 감시 시스템 연구)

  • Cheong, Ha-Young;Choi, Chong-Hwan;Choi, Young-Gyu;Kim, Hyon-Yul;Kim, Tae-Woo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • In this paper, we has proposed an automatic vehicle monitoring system based on computer vision technology. The real-time display system has displayed a system that can be performed in automatic monitoring and control while meeting the essential requirements of ITS. Another advantage has that for a powerful vehicle tracking, the main obstacle handing system, which has the shadow tracking of moving objects. In order to obtain all kinds of information from the tracked vehicle image, the vehicle must be clearly displayed on the surveillance screen. Over time, it's necessary to precisely control the vehicle, and a three-dimensional model-based approach has been also necessary. In general, each type of vehicle has represented by the skeleton of the object or wire frame model, and the trajectory of the vehicle can be measured with high precision in a 3D-based manner even if the system has not running in real time. In this paper, we has applied on segmentation method to vehicle, background, and shadow. The validity of the low level vehicle control tracker was also detected through speed tracking of the speeding car. In conclusion, we intended to improve the improved tracking method in the tracking control system and to develop the highway monitoring and control system.

3D Printing-Based Ultrafast Mixing and Injecting Systems for Time-Resolved Serial Femtosecond Crystallography (시간 분해 직렬 펨토초 결정학을 위한 3차원 프린팅 기반의 초고속 믹싱 및 인젝팅 시스템)

  • Ji, Inseo;Kang, Jeon-Woong;Kim, Taeyung;Kang, Min Seo;Kwon, Sun Beom;Hong, Jiwoo
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.300-307
    • /
    • 2022
  • Time-resolved serial femtosecond crystallography (TR-SFX) is a powerful technique for determining temporal variations in the structural properties of biomacromolecules on ultra-short time scales without causing structure damage by employing femtosecond X-ray laser pulses generated by an X-ray free electron laser (XFEL). The mixing rate of reactants and biomolecule samples, as well as the hit rate between crystal samples and x-ray pulses, are critical factors determining TR-SFX performance, such as accurate image acquisition and efficient sample consumption. We here develop two distinct sample delivery systems that enable ultra-fast mixing and on-demand droplet injecting via pneumatic application with a square pulse signal. The first strategy relies on inertial mixing, which is caused by the high-speed collision and subsequent coalescence of droplets ejected through a double nozzle, while the second relies on on-demand pneumatic jetting embedded with a 3D-printed micromixer. First, the colliding behaviors of the droplets ejected through the double nozzle, as well as the inertial mixing within the coalesced droplets, are investigated experimentally and numerically. The mixing performance of the pneumatic jetting system with an integrated micromixer is then evaluated by using similar approaches. The sample delivery system devised in this work is very valuable for three-dimensional biomolecular structure analysis, which is critical for elucidating the mechanisms by which certain proteins cause disease, as well as searching for antibody drugs and new drug candidates.

Pixel-level Crack Detection in X-ray Computed Tomography Image of Granite using Deep Learning (딥러닝을 이용한 화강암 X-ray CT 영상에서의 균열 검출에 관한 연구)

  • Hyun, Seokhwan;Lee, Jun Sung;Jeon, Seonghwan;Kim, Yejin;Kim, Kwang Yeom;Yun, Tae Sup
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.184-196
    • /
    • 2019
  • This study aims to extract a 3D image of micro-cracks generated by hydraulic fracturing tests, using the deep learning method and X-ray computed tomography images. The pixel-level cracks are difficult to be detected via conventional image processing methods, such as global thresholding, canny edge detection, and the region growing method. Thus, the convolutional neural network-based encoder-decoder network is adapted to extract and analyze the micro-crack quantitatively. The number of training data can be acquired by dividing, rotating, and flipping images and the optimum combination for the image augmentation method is verified. Application of the optimal image augmentation method shows enhanced performance for not only the validation dataset but also the test dataset. In addition, the influence of the original number of training data to the performance of the deep learning-based neural network is confirmed, and it leads to succeed the pixel-level crack detection.

Study on Stabilization of Retinaldehyde using Drug-in-Cyclodextrinin-Liposome (DCL) for Skin Wrinkle Improvement (레틴알 안정화를 위한 사이클로덱스트린-리포좀에 관한 연구)

  • Ha, Ji Hoon;Choi, Hyeong;Hong, In Ki;Han, Sang-Kuen;Bin, Bum Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.1
    • /
    • pp.77-85
    • /
    • 2022
  • Retinaldehyde (RA), vitamin A derivative, is an intermediate between retinol and retinoic acid and has an excellent wrinkle improving effect. In this study, Drug-in-cyclodextrin-in-liposome (DCL) was used to enhance the stability and skin penetration of RA. The complex of RA and hydroxypropyl-beta-cyclodextrin (HP-β-CD) was prepared by the freeze-drying method, and the presence or absence of inclusion of retinal was confirmed by UV-Vis spectrometer, FT-IR and SEM images. RA was captured in HP-β-CD about 95.6% on 1 : 15 (w/w). The retinal-HP-β-CD complex was encapsulated in liposomes using a homomixer and microfluidizer, with an average particle size of 215 ± 4.2 nm and a zeta potential of -31.2 ± 0.5 mv. In the evaluation of the degradation stability of RA, degradation rate of RA-HP-β-CD-liposomes in water was 1.8% higher than RA-liposome (5.8%), RA-HP-β-CD complex (9.7%) and RA alone (37.6%). RA cream (0.05% RA) including RA-HP-β-CD-liposomes was prepared for clinical test with wrinkle-improving efficacy and skin dermis denseness evaluated for 2 or 4 weeks. RA cream showed a significant wrinkle improving effect without skin irritation. In conclusion, it was confirmed that the double stabilization technology using the DCL system contribu tes to the effect of improving skin wrinkles by increasing the stabilization of retinal.

Development of an Algorithm for Automatic Finding the Sick or the Dead Layers in the Multi-tier Layer Battery (고단 직립식 산란계 케이지내의 병계 및 폐사계의 유무를 자동 판정하기 위한 영상처리알고리즘 개발)

  • Chang D. I;Lim S. S.;Zheng S. Y.;Lee S. J.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.35-44
    • /
    • 2005
  • The objectives of this study were to develop an image processing algorithm for finding the sick or the dead layers(SDL) rearing in the multi-tier layer battery, which is a core technology of remote monitoring systems for layers, and to test the performance of algorithm developed in the experimental poultry housing. Based on the literature study and experiment, the standing up of layer was set as a criterion for judging layers whether sick or dead. Then, by the criterion set, an algorithm was developed. The image processing algorithm developed was tested how well it could and SDL at the experimental poultry housing. Test results showed that its monitoring correctness of layers standing up in the cages having all healthy layers was $92\%$, and $96\%$ in the cages having SDL. Therefore, it would be concluded that the image processing algorithm developed in this study was well suited to the purpose of development.

  • PDF

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

Effect of Cosmetics Contained Isotonic Water Mimicked Body Fluid on Cell Activities and Skin (생체 모사수 화장품이 세포 활성과 피부에 미치는 효과)

  • Park, Sun Young;Lee, Sung Hoon;Kim, Eun Joo;Choi, So Woong;Kim, Ji Young;Cho, Seong A;Cho, Jun Cheol;Lee, Hae Kwang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.2
    • /
    • pp.195-201
    • /
    • 2014
  • Body fluid has been studied for diverse fields like Ringer's solutions, artificial joint fluids, cell growth culture media because it plays a crucial role in controlling body temperature and acts as a solvent for diverse metabolite processes in the body and delivery media of mineral, energy source, hormone, signal and drug from and to cell via blood or lymphatic vessel by osmotic pressure or active uptake. Stratum corneum containing extracellular lipids and NMF (natural moisturizing factor) absorbs atmospheric water residing outside of cells and utilize it to hydrate inside of their own. This process is related to skin barrier function. In this study, we conducted the cell viability test with Cell Bio Fluid $Sync^{TM}$, which mimicks body fluids including amino acids, peptides, and monosaccharides to strengthen skin barrier, and the clinical skin improvement test with cosmetics containing Cell Bio Fluid $Sync^{TM}$. In the cell viability test, HaCaT cell was treated with PBS for 3 hours, followed by the treatment of a cell culture medium (DMEM) and isotonic solution (PBS) and Cell Bio Fluid $Sync^{TM}$ for 3 hours each. Then, MTT assay and image analysis were conducted. In the clinical skin improvement test, twenty-one healthy women participated. Participants applied cosmetics containing Cell Bio Fluid $Sync^{TM}$ on their face for a week and evaluated the skin hydration, skin roughness, brightness and evenness. All measurements were conducted after they washed off their face and took a rest under the constant temperature ($22{\pm}2^{\circ}C$) and constant humidity conditions ($50{\pm}5%$) for 20 minutes. All the data were analyzed by SPSS (version 21) software program. Results showed that Cell Bio Fluid $Sync^{TM}$ improved both the cell viability and in vivo skin conditions such as skin hydration, roughness, brightness and evenness.

Effects of Aerobic Exercises and Complex Exercises during 12 Weeks on Blood Lipid in Middle Aged Women according to Body Composition (중년여성의 체구성에 따른 12주 유산소 운동과 복합성 운동이 혈중지질에 미치는 영향)

  • Kim, Joung-Woo;Lee, Moo-Sik;Na, Baeg-Ju;Lee, Jin-Yong;Hong, Jee-Young;Kim, Dae-Kyung;Lee, Bo-Woo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.915-918
    • /
    • 2010
  • 12주간의 유산소 운동 및 복합성 운동이 중년여성의 신체 구성 및 혈중 지질에 미치는 영향을 규명하기 위해 2009년 3월부터 9월까지 일개 D광역시 소재 일개 S구 보건소 12주 운동프로그램에 참가한 40~50대 중년 여성 78명을 대상으로 비만그룹과 정상그룹으로 나누어 주3회, 회당 80분의 유산소 운동과 유산소운동/근력 운동을 병행한 복합성 운동을 목표 심박수 40~60%에서 실시하였다. 1. WHO 기준 적용 시, 정상군의 경우 운동의 유형에 상관없이 유의한 차이가 나타났다. 2. WHO 기준 적용 시, 비만군의 경우 유산소 운동의 근육량, 체지방량, 체지방률을 제외하고 운동의 유형에 상관없이 유의한 차이가 나타났다. 3. 아시아-태평양 기준 적용 시, 정상군의 경우 일부 항목에서만 유의한 차이가 나타났다. 4. 아시아-태평양 기준 적용 시, 비만군의 경우 유산소 운동의 근육량을 제외하고 운동의 유형에 상관 없이 유의한 차이가 나타났다. 상기 결론에서 볼 수 있듯이, 12주간의 운동 프로그램은 WHO 기준 적용 시 일부 항목을 제외하고 운동 유형에 상관없이 40~50대 중년여성의 신체조성 및 혈중지질에 긍정적 효과를 미치는 것으로 판단된다. 그러나 비만에 대해 더 엄격한 아시아 - 태평양 기준 적용 시 특히 정상 군에서 유의한 차이를 보이지 않는 항목이 많이 나타났는데 이것은 우리나라 비만기준을 아시아태평양기준에서 세계 기준으로 바꿀 필요가 있다는 주장을 뒷받침하고 있다. 세계보건기구 WHO는 2004년에 이미 우리나라에 세계비만기준을 따를 것을 권고했는데, 실제 위험성이 정확하게 평가돼야지 정확한 대책이나 관리가 나올 수 있기 때문이다. WHO 기준에 의거 시 질병의 발생 위험도가 낮은 경도비만이 엄격한 아시아-태평양 지역 기준 적용 시 비만으로 분류되어 불필요하게 체형에 대한 부정적인 이미지나 스트레스를 받을 가능성도 있다.

  • PDF

Development of System for Real-Time Object Recognition and Matching using Deep Learning at Simulated Lunar Surface Environment (딥러닝 기반 달 표면 모사 환경 실시간 객체 인식 및 매칭 시스템 개발)

  • Jong-Ho Na;Jun-Ho Gong;Su-Deuk Lee;Hyu-Soung Shin
    • Tunnel and Underground Space
    • /
    • v.33 no.4
    • /
    • pp.281-298
    • /
    • 2023
  • Continuous research efforts are being devoted to unmanned mobile platforms for lunar exploration. There is an ongoing demand for real-time information processing to accurately determine the positioning and mapping of areas of interest on the lunar surface. To apply deep learning processing and analysis techniques to practical rovers, research on software integration and optimization is imperative. In this study, a foundational investigation has been conducted on real-time analysis of virtual lunar base construction site images, aimed at automatically quantifying spatial information of key objects. This study involved transitioning from an existing region-based object recognition algorithm to a boundary box-based algorithm, thus enhancing object recognition accuracy and inference speed. To facilitate extensive data-based object matching training, the Batch Hard Triplet Mining technique was introduced, and research was conducted to optimize both training and inference processes. Furthermore, an improved software system for object recognition and identical object matching was integrated, accompanied by the development of visualization software for the automatic matching of identical objects within input images. Leveraging satellite simulative captured video data for training objects and moving object-captured video data for inference, training and inference for identical object matching were successfully executed. The outcomes of this research suggest the feasibility of implementing 3D spatial information based on continuous-capture video data of mobile platforms and utilizing it for positioning objects within regions of interest. As a result, these findings are expected to contribute to the integration of an automated on-site system for video-based construction monitoring and control of significant target objects within future lunar base construction sites.