• Title/Summary/Keyword: 3D (3Dimensional)

Search Result 6,384, Processing Time 0.039 seconds

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Numerical finite element study of a new perforated steel plate shear wall under cyclic loading

  • Farrokhi, Ali-Akbar;Rahimi, Sepideh;Beygi, Morteza Hosseinali;Hoseinzadeh, Mohamad
    • Earthquakes and Structures
    • /
    • v.22 no.6
    • /
    • pp.539-548
    • /
    • 2022
  • Steel plate shear walls (SPSWs) are one of the most important and widely used lateral load-bearing systems. The reason for this is easier execution than reinforced concrete (RC) shear walls, faster construction time, and lower final weight of the structure. However, the main drawback of SPSWs is premature buckling in low drift ratios, which affects the energy absorption capacity and global performance of the system. To address this problem, two groups of SPSWs under cyclic loading were investigated using the finite element method (FEM). In the first group, several series of circular rings have been used and in the second group, a new type of SPSW with concentric circular rings (CCRs) has been introduced. Numerous parameters include in yield stress of steel plate wall materials, steel panel thickness, and ring width were considered in nonlinear static analysis. At first, a three-dimensional (3D) numerical model was validated using three sets of laboratory SPSWs and the difference in results between numerical models and experimental specimens was less than 5% in all cases. The results of numerical models revealed that the full SPSW undergoes shear buckling at a drift ratio of 0.2% and its hysteresis behavior has a pinching in the middle part of load-drift ratio curve. Whereas, in the two categories of proposed SPSWs, the hysteresis behavior is complete and stable, and in most cases no capacity degradation of up to 6% drift ratio has been observed. Also, in most numerical models, the tangential stiffness remains almost constant in each cycle. Finally, for the innovative SPSW, a relationship was suggested to determine the shear capacity of the proposed steel wall relative to the wall slenderness coefficient.

The comparison between NBD test results and SCB test results using experimental test and numerical simulation

  • Fu, Jinwei;Sarfarazi, Vahab;Haeri, Hadi;Naderi, K.;Fatehi Marji, Mohammad;Guo, Mengdi
    • Advances in concrete construction
    • /
    • v.13 no.1
    • /
    • pp.83-99
    • /
    • 2022
  • The two, NBD and SCB tests using gypsum circular discs each containing a single notch have been experimentally accomplished in a rock mechanics laboratory. These specimens have also been numerically modelled by a two-dimensional particle flow which is based on Discrete Element Method (DEM). Each testing specimen had a thickness of 5 cm with 10 cm in diameter. The specimens' lengths varied as 2, 3, and 4 cm; and the specimens' notch angles varied as 0°, 45° and 90°. Similar semi-circular gypsum specimens were also prepared each contained one edge notch with angles 0° or 45°. The uniaxial testing machine was used to perform the experimental tests for both NBD and SCB gypsum specimens. At the same time, the numerical simulation of these tests were performed by PFC2D. The experimental results showed that the failure mechanism of rocks is mainly affected by the orientations of joints with respect to the loading directions. The failure mechanism and fracturing patterns of the gypsum specimens are directly related to the final failure loading. It has been shown that the number of induced tensile cracks showing the specimens' tensile behavior, and increases by decreasing the length and angle of joints. It should be noted that the fracture toughness of rocks' specimens obtained by NBD tests was higher than that of the SCB tests. The fracture toughness of rocks usually increases with the increasing of joints' angles but increasing the joints' lengths do not change the fracture toughness. The numerical solutions and the experimental results for both NDB and SCB tests give nearly similar fracture patterns during the loading process.

Preliminary study of presumptive intradural-intramedullary intervertebral disc extrusion in 20 dogs

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Background: Intradural-intramedullary intervertebral disc extrusion (IIVDE) is a rare condition of intervertebral disc disease. However, the diagnosis of IIVDE is challenging because the prognosis and imaging characteristics are poorly characterized. Objectives: We aimed to describe the clinical and imaging characteristics of tentatively diagnosed IIVDE in dogs to assess the prognostic utility of neurological grade and magnetic resonance imaging (MRI) findings. Methods: Twenty dogs were included in this retrospective cohort study. Results: Nonchondrodystrophic breeds (n = 16) were more predisposed than chondrodystrophic breeds. Most dogs showed acute onset of clinical signs. Neurological examination at admission showed predominant non-ambulatory paraparesis (n = 9); paresis (n = 16) was confirmed more frequently than paralysis (n = 4). Follow-up neurological examination results were only available for 11 dogs, ten of whom showed neurological improvement and 8 showed successful outcomes at 1 month. The characteristic MRI findings include thoracic vertebra (T)2 hyperintense, T1 hypointense, intramedullary linear tracts with reduced disc volume, and cleft of the annulus fibrosus. None of the MRI measurements were significantly correlated with neurological grade at admission. Neurological grade did not differ according to the presence of parenchymal hemorrhage, parenchymal contrast enhancement, and meningeal contrast enhancement. Neurological grades at admission showed a statistical correlation with those observed at the 1-month follow-up (r = 0.814, p = 0.02). Conclusions: IIVDE is a rare form of disc extrusion commonly experienced after physical activity or trauma and most frequently affects the cranial-cervical and thoracolumbar regions of nonchondrodystrophic dog breeds. Neurological score at admission emerged as a more useful prognostic indicator than MRI findings in dogs with suspected IIVDE.

Ultrasonographic Assessment of the Cutaneous Changes Induced by Topical Use of Novel Peptides Comprising Laminin 5

  • Park, Kyong Chan;Kim, Se Young;Khan, Galina;Park, Eun Soo
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.304-309
    • /
    • 2022
  • Background Laminin 5, which is found in the basement membrane of dermal-epidermal junction (DEJ), is a major adhesive component and associated with proliferating and migrating keratinocytes. In this study, we hypothesized that the topical application of the skin care products containing the novel peptides might restore the DEJ structure by deriving deposition of laminin 5 and promoting the keratinocyte migration. Here, we evaluated the restoration of DEJ by measuring the skin thickness. Methods Single-center retrospective analysis was performed on a total of 13 patients who underwent skin care using Baume L.C.E. (France, Laboratories d' Anjou) between January and March 2021. All patients applied the skin care agent for 2 weeks only on their left hand dorsum. Before the initiation of the application and after 2 weeks, both their hands were evaluated on photography and ultrasound. And the patients were asked to rate their satisfaction with the questionnaire after 2 weeks. Results There was no obvious improvement in photographic assessment and questionnaire. The post-pre difference of skin thickness in ultrasound images was, in left hand, 0.1 ± 0.37 in distal point and 0.1 ± 0.35 in proximal point; and, in right hand, 0 ± 0.17 in distal point and 0 ± 0.15 in proximal point, respectively. The pre-post difference was statistically significant in proximal point (p = 0.035). Conclusion Topical application of novel peptide derivative comprising laminin 5 demonstrated cutaneous changes including skin thickness, as assessed by ultrasound. Further studies using other modalities including dermal density measurement, three-dimensional photography, optical coherence tomography, or skin biopsy would be helpful to determine the skin-improving effects.

CNN based data anomaly detection using multi-channel imagery for structural health monitoring

  • Shajihan, Shaik Althaf V.;Wang, Shuo;Zhai, Guanghao;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • v.29 no.1
    • /
    • pp.181-193
    • /
    • 2022
  • Data-driven structural health monitoring (SHM) of civil infrastructure can be used to continuously assess the state of a structure, allowing preemptive safety measures to be carried out. Long-term monitoring of large-scale civil infrastructure often involves data-collection using a network of numerous sensors of various types. Malfunctioning sensors in the network are common, which can disrupt the condition assessment and even lead to false-negative indications of damage. The overwhelming size of the data collected renders manual approaches to ensure data quality intractable. The task of detecting and classifying an anomaly in the raw data is non-trivial. We propose an approach to automate this task, improving upon the previously developed technique of image-based pre-processing on one-dimensional (1D) data by enriching the features of the neural network input data with multiple channels. In particular, feature engineering is employed to convert the measured time histories into a 3-channel image comprised of (i) the time history, (ii) the spectrogram, and (iii) the probability density function representation of the signal. To demonstrate this approach, a CNN model is designed and trained on a dataset consisting of acceleration records of sensors installed on a long-span bridge, with the goal of fault detection and classification. The effect of imbalance in anomaly patterns observed is studied to better account for unseen test cases. The proposed framework achieves high overall accuracy and recall even when tested on an unseen dataset that is much larger than the samples used for training, offering a viable solution for implementation on full-scale structures where limited labeled-training data is available.

Numerical studies on flow-induced motions of a semi-submersible with three circular columns

  • Tian, Chenling;Liu, Mingyue;Xiao, Longfei;Lu, Haining;Wang, Jin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.599-616
    • /
    • 2021
  • The semi-submersible with three circular columns is an original concept of efficient multifunctional platform, which can be used for marginal oil, gas field, and Floater of Wind Turbines (FOWT). However, under certain flow conditions, especially in uniform current with specific velocities, the eddies will alternatively form and drop behind columns, resulting in the fluctuating lift force and drag force. Consequently, the semi-submersible will subject to the Flow-Induced Motions (FIM). Based on the Detached Eddy Simulation (DES) method, the numerical studies were carried out to understand the FIM characteristics of the three-column semi-submersible at two different parameters, i.e., current incidences (0°, 30°, and 60°-incidences) and reduced velocities (4 ≤ Ur ≤ 14). The results indicate that the lock-in range of 6 ≤ Ur ≤ 10 for the transverse motions is presented, and the largest transverse non-dimensional nominal amplitude is observed at 60°-incidence, with a value of Ay/D = 0:481. The largest yaw amplitude Ayaw is around 3.0° at 0°-incidence in the range of 8 ≤ Ur ≤ 12. The motion magnitude is basically the same as that of a four-column semi-submersible. However, smaller responses are presented compared to those of the three-column systems revealing the mitigation effect of the pontoon on FIM.

Bactericidal Effect of a 275-nm UV-C LED Sterilizer for Escalator Handrails: Optimization of Optical Structure and Evaluation of Sterilization of Six Bacterial Strains

  • Kim, Jong-Oh;Jeong, Geum-Jae;Son, Eun-Ik;Jo, Du-Min;Kim, Myung-Sub;Chun, Dong-Hae;Kim, Young-Mog;Ryu, Uh-Chan
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.202-211
    • /
    • 2022
  • In the pasteurization of escalator handrails using ultraviolet (UV) sterilizers, a combination of light distribution and escalator speed has priority over other important factors. Furthermore, since part of the escalator handrail has a curved structure, proper design is needed to improve the sterilization rate on the surfaces touched by users. In this paper, two types of sterilizers satisfying these conditions are manufactured with 275-nm UV-C LEDs, after modeling the three-dimensional (3D) structure of an escalator handrail and simulating optical distributions of UV-C irradiation on the handrail's surface according to light-emitting diode (LED) positions and reflector variations in the sterilizers. Pasteurization experiments with the UV-C LED sterilizers are conducted on six types of gram-positive and gram-negative bacteria, with exposure times of 0.2, 5, and 15 s at an actual installation distance of 20 mm. The sterilization rates for the gram-positive bacteria are 10.63% to 27.94% at 0.2 s, 89.44% to 96.30% at 5 s, and 99.64% to 99.88% at 15 s. Those for the gram-negative bacteria are 57.70% to 77.63% at 0.2 s, 98.90% to 99.49% at 5 s, and 99.88% to 99.99% at 15 s. The power consumption of the UV-C LED sterilizer is about 8 W, which can be supplied by a self-generation module instead of an external power supply.

An experimental study on triaxial failure mechanical behavior of jointed specimens with different JRC

  • Tian, Wen-Ling;Yang, Sheng-Qi;Dong, Jin-Peng;Cheng, Jian-Long;Lu, Jia-wei
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.181-195
    • /
    • 2022
  • Roughness and joint inclination angle are the important factors that affect the strength and deformation characteristics of jointed rock mass. In this paper, 3D printer has been employed to make molds firstly, and casting the jointed specimens with different joint roughness coefficient (JRC), and different joint inclination angle (α). Conventional triaxial compression tests were carried out on the jointed specimens, and the influence of JRC on the strength and deformation parameters was analyzed. At the same time, acoustic emission (AE) testing system has been adopted to reveal the AE characteristic of the jointed specimens in the process of triaxial compression. Finally, the morphological of the joint surface was observed by digital three-dimensional video microscopy system, and the relationship between the peak strength and JRC under different confining pressures has been discussed. The results indicate that the existence of joint results in a significant reduction in the strength of the joint specimen, JRC also has great influence on the morphology, quantity and spatial distribution characteristics of cracks. With the increase of JRC, the triaxial compressive strength increase, and the specimen will change from brittle failure to ductile failure.

Spatio-temporal pattern of ecological droughts by using the Standardized Water Supply Demand Index in the Hwang River.

  • Sadiqi, Sayed Shajahan;Hong, Eun-Mi;Nam, Won-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.158-158
    • /
    • 2022
  • Ecological drought consequences have received a lot of attention in recent years. Thus, ecological drought was proposed as a new drought category to characterize the impact of drought on ecosystems. The current study used a unique drought index, the standardized supply-demand water index (SSDI), and a run theory to detect ecological drought occurrences and characteristics such as drought-affected area, drought severity, drought duration, drought frequency, and drought orientation in the Hwang River, an environmentally valuable region. Hence, to assess drought-prone areas, the bivariate probability and return period will be calculated using a two-dimensional joint copula. The core results show that (a) the Spatio-temporal characteristics of ecological drought were successfully recognized using the spatial and temporal identification approach; (b) in comparison to the SPEI meteorological drought index, the SSDI is more credible and can more readily and effectively capture the entire properties of ecological drought information; (c) the Hwang river had seen the most severe drought occurrences between the late 1990s and the mid-2020s, with 48.3 percent occurring before the twenty-first century; (d) Severe ecological drought occurrences occurred more frequently in most areas of the Hwang River (e) Only the drought duration and severity in the Hwang area were more responsive to temperature when temperatures rise around 1.1℃, the average drought duration and severity rise around 16 % and 26 %, respectively. This suggested that the Hwang River has been exposed to more severe heat stress in the twenty-first century. Thereupon droughts in the twenty-first century occurred with bigger affected regions, longer durations, higher frequency, and more intensity.

  • PDF