• Title/Summary/Keyword: 3D (3Dimensional)

Search Result 6,385, Processing Time 0.035 seconds

Calculation of 3-D Navier-Stokes Equations by an IAF Method (인수분해 음해법에 의한 3차원 Navier-Stokes 방정식의 계산)

  • Seung-Hyun Kwag
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.1
    • /
    • pp.63-70
    • /
    • 1994
  • The three-dimensional incompressible clavier-Stokes equations are solved to simulate the flow field around a Wigley model with free-surface. The IAF(Implicit Approximate Factorization) method is used to show a good success in reducing the computing time. The CPU time is almost an half of that if the IAF method were used. The present method adopts the local linearization and Euler implicit scheme without the pressure-gradient terms for the artificial viscosity. Calculations are carried out at the Reynolds number of $10^6$ and the Froude numbers are 0.25, 0.289 and 0.316. For the approximations of turbulence, the Baldwin-Lomax model is used. The resulting free-surface wave configurations and the velocity vectors are compared with those by the explicit method and experiments.

  • PDF

Polarization-Dependent Microlens Array Using Reactive Mesogen Aligned by Top-Down Nanogrooves for Switchable Three-Dimensional Applications

  • Son, Ki-Beom;Kim, Mugeon;Park, Min-Kyu;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.265-271
    • /
    • 2015
  • We propose a reactive mesogen (RM) lens array to obtain good focusing behavior along with a short focal plane, where the focusing behavior is switchable according to the polarization state of incident light. Polarization-dependent focusing behavior is obtained using a planoconvex RM microlens array on a planoconcave isotropic lens template. Even though the sagitta of our RM lens is high, to obtain the short focal length, the RM layer can be aligned well by introducing a top-down alignment effect, using a nanogrooved template. The optical noise due to the $moir{\acute{e}}$ effect generated by the nanogrooves on the surface of the planoconvex RM layer can be removed simply by overcoating a thin RM layer, which is self-aligned by the geometric surface effect, without an additional alignment process. We demonstrate a hexagonal-packed RM lens array that has a very high fill factor and symmetric phase profile, for an ideal lens.

Improvement of RRT*-Smart Algorithm for Optimal Path Planning and Application of the Algorithm in 2 & 3-Dimension Environment (최적 경로 계획을 위한 RRT*-Smart 알고리즘의 개선과 2, 3차원 환경에서의 적용)

  • Tak, Hyeong-Tae;Park, Cheon-Geon;Lee, Sang-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.27 no.2
    • /
    • pp.1-8
    • /
    • 2019
  • Optimal path planning refers to find the safe route to the destination at a low cost, is a major problem with regard to autonomous navigation. Sampling Based Planning(SBP) approaches, such as Rapidly-exploring Random Tree Star($RRT^*$), are the most influential algorithm in path planning due to their relatively small calculations and scalability to high-dimensional problems. $RRT^*$-Smart introduced path optimization and biased sampling techniques into $RRT^*$ to increase convergent rate. This paper presents an improvement plan that has changed the biased sampling method to increase the initial convergent rate of the $RRT^*$-Smart, which is specified as m$RRT^*$-Smart. With comparison among $RRT^*$, $RRT^*$-Smart and m$RRT^*$-Smart in 2 & 3-D environments, m$RRT^*$-Smart showed similar or increased initial convergent rate than $RRT^*$ and $RRT^*$-Smart.

Development of Optical Sighting System for Moving Target Tracking

  • Jeung, Bo-Sun;Lim, Sung-Soo;Lee, Dong-Hee
    • Current Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.154-163
    • /
    • 2019
  • In this study, we developed an optical sighting system capable of shooting at a long-distance target by operating a digital gyro mirror composed of a gyro sensor and an FSM. The optical sighting system consists of a reticle part, a digital gyro mirror (FSM), a parallax correction lens, a reticle-ray reflection mirror, and a partial reflection window. In order to obtain the optimal volume and to calculate the leading angle range according to the driving angle of the FSM, a calculation program using Euler rotation angles and a three-dimensional reflection matrix was developed. With this program we have confirmed that the horizontal leading angle of the developed optical sighting system can be implemented under about ${\pm}8^{\circ}$ for the maximum horizontal driving angle (${\beta}={\pm}12.5^{\circ}$) of the current FSM. Also, if the ${\beta}$ horizontal driving angle of the FSM is under about ${\pm}15.5^{\circ}$, it can be confirmed that the horizontal direction leading angle can be under ${\pm}10.0^{\circ}$. If diagonal leading angles are allowed, we confirmed that we can achieve a diagonal leading angle of ${\pm}10.0^{\circ}$ with a vertical driving angle ${\alpha}$ of ${\pm}7.1^{\circ}$ and horizontal driving angle ${\beta}$ of ${\pm}12.5^{\circ}$.

Effect of Silane Coupling Treatment on the Joining and Sealing Performance between Polymer and Anodized Aluminum Alloy

  • Lee, Sung-Hyung;Yashiro, Hitoshi;Kure-Chu, Song-Zhu
    • Korean Journal of Materials Research
    • /
    • v.31 no.3
    • /
    • pp.122-131
    • /
    • 2021
  • In the fabrication of joined materials between anodized aluminum alloy and polymer, the performance of the metal-polymer joining is greatly influenced by the chemical properties of the oxide film. In a previous study, the dependence of physical joining strength on the thickness, structure, pore formation, and surface roughness of films formed on aluminum alloys is investigated. In this study, we investigated the effect of silane coupling treatment on the joining strength and sealing performance between aluminum alloy and polymer. After a two-step anodization process with additional treatment by silane, the oxide film with chemically modified nanostructure is strongly bonded to the polymer through physical and chemical reactions. More specifically, after the two-step anodization with silane treatment, the oxide film has a three-dimensional (3D) nanostructure and the silane components are present in combination with hydroxyl groups up to a depth of 150 nm. Accordingly, the joining strength between the polymer and aluminum alloy increases from 29 to 35 MPa, and the helium leak performance increases from 10-2-10-4 to 10-8-10-9 Pa ㎥ s-1.

Impact of adjacent excavation on the response of cantilever sheet pile walls embedded in cohesionless soil

  • Singh, Akshay Pratap;Chatterjee, Kaustav
    • Geomechanics and Engineering
    • /
    • v.30 no.3
    • /
    • pp.293-312
    • /
    • 2022
  • Cantilever sheet pile walls having section thinner than masonry walls are generally adopted to retain moderate height of excavation. In practice, a surcharge in the form of strip load of finite width is generally present on the backfill. So, in the present study, influence of strip load on cantilever sheet pile walls is analyzed by varying the width of the strip load and distance from the cantilever sheet pile walls using finite difference based computer program in cohesionless soil modelled as Mohr-Coulomb model. The results of bending moment, earth pressure, deflection and settlement are presented in non-dimensional terms. A parametric study has been conducted for different friction angle of soil, embedded depth of sheet pile walls, different magnitudes and width of the strip load acting on the ground surface and at a depth below ground level. The result of present study is also validated with the available literature. From the results presented in this study, it can be inferred that optimum behavior of cantilever sheet pile walls is observed for strip load having width 2 m to 3 m on the ground surface. Further as the depth of strip load below the ground surface increases below the ground level to 0.75 times excavation height, the bending moment, settlement, net earth pressure and deflection decreases and then remains constant.

Analyzing Hand Geometry to Develop Safety Gloves for Dementia People (치매 환자용 안전 장갑 개발을 위한 손 형태 분석)

  • Sujoung Cha
    • Journal of Fashion Business
    • /
    • v.27 no.3
    • /
    • pp.19-34
    • /
    • 2023
  • The purpose of this study was to analyze the three-dimensional hand-related dimensions of elderly women aged 70 to 84 years and to characterize them to develop safety gloves for dementia patients. The 3D data from the 8th Human Size Survey of the National Institute of Standards and Technology, Size Korea, were analyzed using the SPSS 26.0 program. The straight thumb length was longer in elderly women aged 70-74 than in those aged 80-84. To analyze the hand type of elderly women, four factors were categorized: hand and finger horizontal factor, hand vertical factor, finger digit V thickness factor, and finger length factor. Elderly women's hand types were categorized as 'long hands and thin fingers', 'thick hands with long fingers', and 'short hands and thick little fingers'. Elderly women aged 70-74 years and 80-84 years were analyzed as having the most 'long hands and thin fingers' type, while older women aged 75-79 years were analyzed as having the most 'thick hands and long fingers' type. It is known that the fingers get thicker and the size of hands increase as age advances, but by the age 80, there is a change in the size of hands again. In future research, it would be worth expanding to other age groups to explore differences between age groups and to develop safety gloves for real-world dementia patients based on the hand types analyzed.

A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain

  • Jung, Yu-Seok;Lee, Jae-Whang;Choi, Yeon-Jo;Ahn, Jin-Soo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.111-115
    • /
    • 2010
  • PURPOSE. This study was conducted to evaluate clinical validity of a zirconia full-coverage crown by comparing zirconia's wear capacity over antagonistic teeth with that of feldspathic dental porcelain. MATERIALS AND METHODS. The subject groups were divided into three groups: the polished feldspathic dental porcelain group (Group 1), the polished zirconia group (Group 2), and the polished zirconia with glazing group (Group 3). Twenty specimens were prepared from each group. Each procedure such as plasticity, condensation, and glazing was conducted according to the manufacturer's manual. A wear test was conducted with 240,000 chewing cycles using a dual-axis chewing simulator. The degree of wear of the antagonistic teeth was calculated by measuring the volume loss using a three-dimensional profiling system and ANSUR 3D software. The statistical significance of the measured degree of wear was tested with a significant level of 5% using one-way ANOVA and the Tukey test. RESULTS. The degrees of wear of the antagonistic teeth were $0.119{\pm}0.059\;mm^3$ in Group 1, $0.078{\pm}0.063\;mm^3$ in Group 3, and $0.031{\pm}0.033\;mm^3$ in Group 2. Statistical significance was found between Group 1 and Groups 2 and between Group 2 and 3, whereas no statistical significance was found between Group 1 and Group 3. CONCLUSION. Despite the limitations of this study on the evaluation of antagonistic teeth wear, the degree of antagonistic tooth wear was less in zirconia than feldspathic dental porcelain, representing that the zirconia may be more beneficial in terms of antagonistic tooth wear.

Solution Dynamics and Crystal Structure of $CpMoOs_{3}(CO)_{10}(\mu-H)_{2}[\mu_{3}-\eta^{2}-C(O)CH_{2}Tol]$

  • Joon T. Park;Jeong-Ju Cho;Kang-Moon Chun;Sock-Sung Yun;Kim SangSoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.137-143
    • /
    • 1993
  • The tetranuclear heterometallic complex CpMo$Os_3(CO)_{10}({\mu]-H)2[{\mu}3-{\eta}^2-C(O)CH_2Tol]\;(1,\;Cp={\eta}^5-C_5H_5,\;Tol=p-C_6H_4Me)$ has been examined by variable-temperature $^{13}$C-NMR spectroscopy and by a full three-dimensional X-ray structual analysis. Complex 1 crystallizes in the orthorhombic space group Pna2$_1$ with a = 12.960(1) ${\AA}$, b = 11.255(l) ${\AA}$, c = 38.569(10)${\AA}$, V = 5626(2) ${\AA}^3$ and ${\rho}$(calcd) = 2.71 gcm$^{-3}$ for Z = 8 and molecular weight 1146.9. Diffraction data were collectedon a CAD4 diffractometer, and the structure was refined to $R_F$ = 9.7% and $R_{W^F}$ = 9.9% for 2530 data (MoK${\alpha}$ radiation). There are two essentially equivalent molecules in the crystallographic asymmetric unit. The tetranuclear molecule contains a triangulated rhomboidal arrangement of metal atoms with Os(2) and Mo at the two bridgehead positions. The metal framework is planar; the dihedral angle between Os(l)-Os(2)-Mo and Os(3)-Os(2)-Mo planes is 180$^{\circ}$. A triply bridging (${\mu}_3,\;{\eta}^2$) acyl ligand lies above the Os(l)-Os(2)-Mo plane; the oxygen atom spans the two bridgehead positions, while the carbon atom spans one bridgehead position and an acute apical position. The molecular architecture is completed by an ${\eta}^5$-cyclopentadienyl ligand and a semi-triply bridging carbonyl ligand on the molybdenum atom, and nine terminal carbonyl ligands-four on Os(3), three on Os(l), and two on Os(2). The two hydride ligands are inferred to occupy the Os(l)-Os(2) and Mo-Os(3) edges from structural and NMR data.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.