• Title/Summary/Keyword: 3D (3Dimensional)

Search Result 6,385, Processing Time 0.035 seconds

Convergence change in a tunnel face approaching fault zones (파쇄대에 접근하는 터널의 내공변위 변화 해석)

  • Lee, In-Mo;Lee, Seung-Ju;Lee, Joo-Gong;Lee, Dae-Hyuck
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.3
    • /
    • pp.235-245
    • /
    • 2002
  • The purpose of this study is to figure out the tendency of tunnel convergence during excavation and to present a methodology for the prediction of a fault zone ahead of a tunnel face by analyzing three dimensional displacements in various ways. 3-D numerical analysis was performed to investigate changes of tunnel convergence vectors near a fault zone and to propose a flow chart for predicting fault zones. Results of the site investigation and results of trend line analysis of in-situ data were compared to verify the usefulness of a trend line analysis. It is concluded that the orientation of faults can be predicted by using stereonets and the direction of initial stresses can be predicted from the arm length of a displacement vector as a tunnel approaches fault zones. The results of the trend line analysis coincided with those of the site investigation, and a methodology for the prediction of a fault zone was proposed.

  • PDF

Hypofractionated radiotherapy for early glottic cancer: a retrospective interim analysis of a single institution

  • Lee, Jeong Won;Lee, Jeong Eun;Park, Junhee;Sohn, Jin Ho;Ahn, Dongbin
    • Radiation Oncology Journal
    • /
    • v.37 no.2
    • /
    • pp.82-90
    • /
    • 2019
  • Purpose: To evaluate the results of hypofractionated radiotherapy (HFX) for early glottic cancer. Materials and Methods: Eighty-five patients with cT1-2N0M0 squamous cell carcinoma of the glottis who had undergone HFX, performed using intensity-modulated radiotherapy (IMRT, n = 66) and three-dimensional conformal radiotherapy (3D CRT, n = 19) were analyzed. For all patients, radiotherapy was administered at 60.75 Gy in 27 fractions. Forty-three patients received a simultaneous integrated boost (SIB) of 2.3-2.5 Gy per tumor fraction. Results: The median follow-up duration was 29.9 months (range, 5.5 to 76.5 months). All patients achieved complete remission at a median of 50 days after the end of radiotherapy (range, 14 to 206 days). The 5-year rates for locoregional recurrence-free survival was 88.1%, and the 5-year overall survival rate was 86.2%. T2 stage was a prognostic factor for locoregional recurrence-free survival after radiotherapy (p = 0.002). SIB for the tumor did not affect disease control and survival (p = 0.191 and p = 0.387, respectively). No patients experienced acute or chronic toxicities of ≥grade 3. IMRT significantly decreased the dose administered to the carotid artery as opposed to 3D CRT (V35, p < 0.001; V50, p < 0.001). Conclusions: Patients treated with HFX achieved acceptable locoregional disease control rates and overall survival rates compared with previous HFX studies. A fraction size of 2.25 Gy provided good disease control regardless of SIB administration.

Multi-Port Register File Design and Implementation for the SIMD Programmable Shader (SIMD 프로그래머블 셰이더를 위한 멀티포트 레지스터 파일 설계 및 구현)

  • Yoon, Wan-Oh;Kim, Kyeong-Seob;Cheong, Jin-Ha;Choi, Sang-Bang
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.9
    • /
    • pp.85-95
    • /
    • 2008
  • Characteristically, 3D graphic algorithms have to perform complex calculations on massive amount of stream data. The vertex and pixel shaders have enabled efficient execution of graphic algorithms by hardware, and these graphic processors may seem to have achieved the aim of "hardwarization of software shaders." However, the hardware shaders have hitherto been evolving within the limits of Z-buffer based algorithms. We predict that the ultimate model for future graphic processors will be an algorithm-independent integrated shader which combines the functions of both vertex and pixel shaders. We design the register file model that supports 3-dimensional computer graphic on the programmable unified shader processor. we have verified the accurate calculated value using FPGA Virtex-4(xcvlx200) made by Xilinx for operating binary files made by the implementation progress based on synthesis results.

Study on the character of the old aged pulsation (고령자의 맥상 특성에 대한 맥파분석적인 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Gyeong-Ho;Gang, Hui-Jeong;Cho, Sang-Won;Park, Young-Jae;Kim, Min-Yong;Oh, Hwan-Sup;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Objectives: The basis research of aged people's healthcare technology is very important, because our nation goes into an aged society rapidly. Especially in traditional medicine, pulse shapes of aged people were supposed to weak and empty pulse until now, but any objective measurement and compare research do not taken. Methods and Results: Therefore in this study we design observation study to find characteristic of pulse between younger group (age $20{\sim}30$) and elder group (age $43{\sim}80$) in Busan area. We used 3-dimensional pulse analyzer '3-D MAC' (Daeyomedi Co., Ltd.). And major parameters for comparison are 1) pulse height (h1), 2) applied pressure, 3) pulse power (energy), 4) high pressure duration (w) and 5) R-AI. Conclusions: According to analysis result, elder people's pulse has more large value in pulse height, applied pressure and pulse power than younger's that. It reveals that elder people in modernized lifestyle has Yang symptoms as well Yin symptoms. Consequently we need new method to care elder people's health, and this means more important direction than old text book. From now on verification research with objective diagnosis device like 3-D MAC, must be activated to build of evidence in traditional medicine. Cause traditional medicine's spirit of care and prevention is suitable to care elder people's cardiac and cerebral vascular disease those are have close relation with elder people.

  • PDF

Influence of Weak Ground Ahead of the Tunnel Face on 3D-displacement and Face Extrusion (막장전방의 연약층이 터널 3차원변위 및 막장 수평변위에 미치는 영향)

  • Jeon, Je-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.189-206
    • /
    • 2003
  • During tunnel excavation in urban area a systematic monitoring is important for the purpose of determination of support type and quantity, as well as for the control of stability of both surface structures and the tunnel itself due to the frequently, and in many cases, abruptly changing ground condition. In Austria absolute displacement monitoring methods have replaced relative displacement measurements by geodetic methods to a large extent. Prompt detection of weak ground ahead of the tunnel face as well as better adjustment of excavation and support to the geotechnical conditions is possible with the help of the improved methods of data evaluation on sites. Deformation response of the ground to excavation starts ahead of the tunnel face, therefore, the deformation and state of the tunnel advance core is the key factor of the whole deformation process after excavation. In other words, the rigidity and state of the advance core play a determining role in the stability of both surface structures and the tunnel itself. This paper presents the results from detailed three-dimensional numerical studies, exploring vertical displacements, vector orientations and extrusions on tunnel face during the progressive advancement for the shallow tunnel in various geotechnical conditions.

THE ACCURACY OF MEASUREMENTS DURING MODEL SURGERY FOR ORTHOGNATHIC PLANNING (악교정 수술을 위한 석고모형 수술시의 계측오차)

  • Lee, Sang-Hwy;Lee, Seung-Hoon;Ju, Hyeon-Ho;Won, Dong-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.1
    • /
    • pp.37-45
    • /
    • 2001
  • The errors in orthognathic surgery can occur during the preoperative preparations including the model surgery, but till now there's been some lack of reserches about them. So we wanted to verify the accuracies in measurements used in model surgery. We compared the accuracy of measurements by vernier calipers, which has been the main measurement tool for conventional model surgery, and that by height gauge, which is recently claimed to be more accurate, with 3 dimensional coordinate analyzer. We could have following results and have a plan to use them for the invention of new model surgery techniques. 1. The measurement errors in Group 1, which mean the difference between "the measurements by 3-D analyzer"and "the measurements by height gauge", were small enough with the range of $0.1{\sim}0.2mm$ in all planes. 2. The mean error in Group 2, which is the differences between the measurements of 3-D analyzer and those of vernier calipers, was 1.1mm. 3. The measurement errors in Group 2 were variable according to the factors including the differences of individuality and expertness of each measurers. But in case of Group 1, they were small and not variable by the expertness. 4. The measurements were more accurate at the points in anterior teeth than in molar teeth in Group 1 and 2. 5. The errors after model surgery increased remarkably, compared with those before surgery in Group 2. And the situation was different in Group 1 in that errors decreased after surgery. According to these results, it assumed that the measurements with height gauge during the model surgery for orthognathic surgery are accurate enough and can be maintained, regardless of complexity of models, individuality, or expertness of measurers.

  • PDF

940-nm 350-mW Transverse Single-mode Laser Diode with AlGaAs/InGaAs GRIN-SCH and Asymmetric Structure

  • Kwak, Jeonggeun;Park, Jongkeun;Park, Jeonghyun;Baek, Kijong;Choi, Ansik;Kim, Taekyung
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.583-589
    • /
    • 2019
  • We report experimental results on 940-nm 350-mW AlGaAs/InGaAs transverse single-mode laser diodes (LDs) adopting graded-index separate confinement heterostructures (GRIN-SCH) and p,n-clad asymmetric structures, with improved temperature and small-divergence beam characteristics under high-output-power operation, for a three-dimensional (3D) motion-recognition sensor. The GRIN-SCH design provides good carrier confinement and prevents current leakage by adding a grading layer between cladding and waveguide layers. The asymmetric design, which differs in refractive-index distribution of p-n cladding layers, reduces the divergence angle at high-power operation and widens the transverse mode distribution to decrease the power density around emission facets. At an optical power of 350 mW under continuous-wave (CW) operation, Gaussian narrow far-field patterns (FFP) are measured with the full width at half maximum vertical divergence angle to be 18 degrees. A threshold current (Ith) of 65 mA, slope efficiency (SE) of 0.98 mW/mA, and operating current (Iop) of 400 mA are obtained at room temperature. Also, we could achieve catastrophic optical damage (COD) of 850 mW and long-term reliability of 60℃ with a TO-56 package.

Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.335-339
    • /
    • 2018
  • PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (${\alpha}=.05$). RESULTS. The $RMS{\pm}SD$ values of scanning trueness of the abutment impression and stone model were $22.4{\pm}4.4$ and $17.4{\pm}3.5{\mu}m$, respectively (P<.012). The $RMS{\pm}SD$ values of scanning precision of the abutment impression and stone model were $16.4{\pm}2.9$ and $14.6{\pm}1.6{\mu}m$, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

Modern Package Design Factors Hidden in Traditional Korean Wrapping Cloth (한국전통 보자속에 은유된 현대 포장디자인 요소)

  • Kwon, Il-Hyun;Nam, Young-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.1-12
    • /
    • 2007
  • In this study, the use of wrapping cloth was studied by examining documents and drawings from the past that reflect the life of people of the time with a focus on "minbo" (a wrapping cloth used by civilians) and "gungbo" (a wrapping cloth used by the ruling class). Unlike the bag culture of industrialized society, wrapping cloth has diversity, dynamic and receptiveness to changes as well as coexistence of 2 and 3-dimension. Environment-friendliness of recyclability of the cloth used for making wrapping cloth is not found in any other traditional transportation device cultures of the world. Such polysemous elements converge into a various functions with the development of technology and raw material and allow a package design from a new perspective. This study analyzes the above factors from a package design perspective to suggest an innovative modern package design that has fusional, diverse features.

Three-dimensional Chemical Shift Imaging with PRESS Excitation and Spiral Readouts (점구분 분광술 여기 방식과 나선형 판독경사를 이용한 삼차원 화학적 변위 영상법의 개발)

  • Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose : We developed a 3D CSI (chemical shift imaging) sequence that uses the PRESS (point resolved spectroscopy) excitation scheme and spiral-based readout gradients. Materials and Methods : We implemented constant-density spirals ($32{\times}32$ matrix, $24{\times}24\;cm$ FOV) which use analytic equations to enable real-time prescription on the scanner. In-vivo data from the brain were collected and reconstructed using the gridding algorithm. Results : Data illustrate that with our imaging sequence, the benefits of the PRESS technique, which include elimination of lipid artifacts, remain intact while flexible scan time versus resolution tradeoffs can be achieved using the constant-density spirals. Volumetric high resolution 3D CSI covering 5760 cm3 could be obtained in 12.5 minutes. Conclusion : Spiral-based readout gradients offer a flexible tradeoff between scan time versus resolution. By combining this feature with PRESS based excitation, efficient methods of volumetric spectroscopic imaging can be accomplished by obtaining whole brain coverage while eliminating lipid contamination.

  • PDF