• Title/Summary/Keyword: 3D(three-dimensional)

Search Result 4,304, Processing Time 0.04 seconds

A Study of the 3D-Reconstruction of indoor using Stereo Camera System (스테레오 카메라를 이용한 실내환경의 3차원 복원에 관한 연구)

  • Lee Dong-Hun;Um Dae-Youn;Kang Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.42-47
    • /
    • 2005
  • In this papcr, we address the 3D reconstruction of the indoor circumstance using what the data is extracted by a pall of image from Stereo Camera. Generally sucaking, there arc three methods to extract 3-Dimensional data using IR sensor, Laser sensor and Stereo camera sensor. The best is stereo camera sensor which can show a high performance at a reasonable price. We used 'Window Correlation Matching Method' to extract 3-Dimensional data in stereo image. We proposed new Method to reduce error data, said 'Histogram Weighted Hough Transform'. Owing to this mettled, we reduced error data in each stereo image. So reconstruction is well done. 3-Dimensional Reconstruction is accomplished by using the DirectX that is well known as 3D-Game development tool. We show that the stereo camera can be not only used to extract 3-dimensional data but also applied to reconstruct the 3-Dimensional circumstance. And we try to reduce the error data using various method.

Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

  • Yousefi, Faezeh;Shokri, Abbas;Farhadian, Maryam;Vafaei, Fariborz;Forutan, Fereshte
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose: This study aimed to compare the accuracy of 3-dimensional(3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials and Methods: Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test. Results: The landmarks measured on prototypes fabricated using the FDM and DLP techniques based on all 4 imaging systems showed differences from the gold standard. No significant differences were noted between the FDM and DLP techniques. Conclusion: The 3D printers were reliable systems for maxillofacial reconstruction. In this study, scanners with smaller voxels had the highest precision, and the DLP printer showed higher accuracy in reconstructing the maxillofacial landmarks. It seemed that 3D reconstructions of the anterior region were overestimated, while the reconstructions of intra-socket dimensions and implant holes were slightly underestimated.

A Tetrahedral Decomposition Method for Computing Tangent Curves of 3D Vector Fields (3차원 벡터필드 탄젠트 곡선 계산을 위한 사면체 분해 방법)

  • Jung, Il-Hong
    • Journal of Digital Contents Society
    • /
    • v.16 no.4
    • /
    • pp.575-581
    • /
    • 2015
  • This paper presents the development of certain highly efficient and accurate method for computing tangent curves for three-dimensional vector fields. Unlike conventional methods, such as Runge-Kutta method, for computing tangent curves which produce only approximations, the method developed herein produces exact values on the tangent curves based upon piecewise linear variation over a tetrahedral domain in 3D. This new method assumes that the vector field is piecewise linearly defined over a tetrahedron in 3D domain. It is also required to decompose the hexahedral cell into five or six tetrahedral cells for three-dimensional vector fields. The critical points can be easily found by solving a simple linear system for each tetrahedron. This method is to find exit points by producing a sequence of points on the curve with the computation of each subsequent point based on the previous. Because points on the tangent curves are calculated by the explicit solution for each tetrahedron, this new method provides correct topology in visualizing 3D vector fields.

Flow Analysis Using 1 and 3 Dimensional Hybrid Mesh For Ultra-High Speed Vehicle Inside A Long Distance Tunnel (1-3차원 혼합격자를 이용한 장거리 터널 내 고속 운송체 유동해석)

  • Kim, Tae-Kyung;Choi, Joong-Keun;Kwon, Hyeok-Bin;Kim, Kyu-Hong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.107-118
    • /
    • 2011
  • This paper performs flow analysis of ultra-high speed vehicle inside the long distance tunnel. One and three dimensional hybrid mesh was used for describing moving motion and flow analysis of an vehicle inside a long distance tunnel which over 20 km. Flow analysis and aerodynamic drag measuring were performed by three dimensional mesh: around vehicle, and pressure waves of a tunnel was measured by one dimensional mesh: the other region where rare changing of flow pattern.

  • PDF

Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone loss

  • Hangmiao Lyu;Li Xu;Huimin Ma;Jianxia Hou;Xiaoxia Wang;Yong Wang;Yijiao Zhao;Weiran Li;Xiaotong Li
    • The korean journal of orthodontics
    • /
    • v.53 no.2
    • /
    • pp.77-88
    • /
    • 2023
  • Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland-Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.

Shape Recognition of 3-D Object Using Texels (텍셀을 이용한 3차원 물체의 형상 인식)

  • Kim, Do-Nyun;Cho, Dong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.460-464
    • /
    • 1990
  • Texture provides an important source of information about the local orientation of visible surfaces. An important task that arises in many computer vision systems is the reconstruction of three-dimensional depth information from two-dimensional images. The surface orientation of texel is classified by the Artificial Neural Network. The classification method to recognize the shape of 3D object with artificial neural network requires less developing time comparing to conventional method. The segmentation problem is assumed to be solved. The surface in view is smooth and is covered with repeated texture elements. In this study, 3D shape reconstruct using interpolation method.

  • PDF

Characterization of Interaction between Two Particles/Bubbles Flow with Moving Object Flow Image Analyzer System (MOFIA에 의한 두개 입자/기포간 상호작용에 관한 연구)

  • Choi Hae Man;Monji Hideaki;Matsui Goichi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2005
  • This paper deals with interaction between two bubbles or particles and flow around them, visualized by a moving object flow image analyzer(MOFIA) consisting of a three-dimensional (3D) moving object image analyzer(MOIA) and two-dimensional particle image velocimetry(PIV). The experiments were carried out for rising bubbles or particles of various densities, sizes, and/or shapes in stagnant water in a vertical pipe. In the MOFIA employed, 3D-MOIA was used to measure particles or bubbles motion and PIV was used to measure fluid flow, The experimental results showed that the interaction was characterized by the shape, size and density of two particles or bubbles.

Design of Bristle Shapes using 3-dimensional Teeth Data for the Periodontally Involved Patients

  • Kim, Hyun-Jun;Suh, Myung-Won;Bae, Jong-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.180-188
    • /
    • 2006
  • Bristles for the prosthetic and periodontally involved patients are investigated based on previous studies. Specifically, the ideal location and dimensions of bristles for the patients who were installed with fixed prostheses and severely involved periodontitis were investigated. 3D (Three-Dimensional) scanner was used to develop 3D visual models of bristles and teeth. These models were used for designing the ideal bristles. In the design, the interproximal area of dental arch and bristle must be maximized and the standard teeth may have to be chosen from many gypsum molds. During the design process the factors that influence plaque removal by the bristle were considered.