• Title/Summary/Keyword: 3D(three-dimensional)

Search Result 4,304, Processing Time 0.037 seconds

PICTURE PROCESSING ON ISOMETRIC FUZZY REGULAR ARRAY LANGUAGES

  • A. JOHN KASPAR;D.K. SHEENA CHIRISTY;D.G. THOMAS
    • Journal of applied mathematics & informatics
    • /
    • v.42 no.3
    • /
    • pp.483-497
    • /
    • 2024
  • Isometric array grammar is one of the simplest model to generate picture languages, since both sides of its production rule have the same shape. In this paper, we have introduced isometric fuzzy regular array grammars to generate isometric fuzzy regular array languages and discussed its closure properties. Also, the relation between isometric fuzzy regular array grammar and boustrophedon fuzzy finite automata has been discussed. Moreover, we study the relation between two dimensional fuzzy regular grammars with returning fuzzy finite automata and boustrophedon fuzzy finite automata. Further, the hierarchy results of these three classes of languages have been discussed.

Three Dimensional Dynamic Added Variable Plots

  • Seo, Han-Son
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.2
    • /
    • pp.345-353
    • /
    • 2004
  • Graphical methods for the specification of the curvature as a function of two predictors are animated to see the effect of an added variable to the model. Through a 3D animated plot it might be difficult to find a sequence of interpretable plots. But examples demonstrate that useful information can be obtained by using rotation technique in 3D plot. Besides 3D plots, an example of 2D animated plot applied to the case of high correlation between predictors and an added predictor is also given. It implies that speed of the convergence to a certain image in a dynamic plot may be understood as an influence of collinearity.

Construction of Virtual Images for a Benchmark Test of 3D-PTV Algorithms for Flows

  • Hwang, Tae-Gyu;Doh, Deog-Hee;Hong, Seong-Dae;Kenneth D. Kihm
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1185-1194
    • /
    • 2004
  • Virtual images for PIV are produced for the construction of a benchmark test tool of PTV systems, Camera parameters obtained by an actual experiment are used to construct the virtual images, LES(Large Eddy Simulation) data sets of a channel flow are used for generation of the virtual images, Using the virtual images and the camera's parameters. three-dimensional velocity vectors are obtained for a channel flow. The capabilities of a 3D-PTV algorithm are investigated by comparing the results obtained by the virtual images and those by an actual measurement for the channel flow.

A Low-Loss Patch LTCC 60 GHz BPF Using Double Patch Resonators

  • Lee, Young Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.570-572
    • /
    • 2012
  • In this paper, a three-dimensional (3-D) low-loss and wide-band BPF based on low-temperature co-fired ceramic (LTCC) has been presented for mm-wave wireless communication applications. The proposed BPF is designed in a 6-layer LTCC substrate. The double patch resonators are fully integrated into the LTCC dielectrics and vertical via and planar CPW transitions are designed for interconnection between embedded resonators and in/output ports and MMICs, respectively. The designed BPF was fabricated in a 6-layer LTCC dielectric. The fabricated BPF shows a centre frequency (fc) of 53.23 GHz and a 3dB bandwidth of 14.01 % from 49.5 to 56.9 GHz (7.46 GHz). An insertion loss of -1.56 dB at fc and return losses below -10 dB are achieved. Its whole size is $4.7{\times}1.7{\times}0.684mm^3$.

  • PDF

Curved Projection Integral Imaging Using an Additional Large-Aperture Convex Lens for Viewing Angle Improvement

  • Hyun, Joo-Bong;Hwang, Dong-Choon;Shin, Dong-Hak;Lee, Byung-Gook;Kim, Eun-Soo
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.105-110
    • /
    • 2009
  • In this paper, we propose a curved projection integral imaging system to improve the horizontal and vertical viewing angles. The proposed system can be easily implemented by additional use of a large-aperture convex lens in conventional projection integral imaging. To obtain the simultaneous display of 3D images through real and virtual image fields, we propose a computer-generated pickup method based on ray optics and elemental images, which are synthesized for the proposed system. To show the feasibility of the proposed system, preliminary experiments are carried out. Experimental results indicate that our system improves the viewing angle and displays 3D images simultaneously in real and virtual image fields.

  • PDF

Droplet Ejection and Experimental Study on the Application of Industrial Inkjet Printhead (산업용 잉크젯 프린트헤드 액적 토출현상의 실험적 해석)

  • Park, Sung-Jun
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.34-40
    • /
    • 2011
  • In this paper, a hybrid design tool combining one-dimensional(1D) lumped model and three-dimensional computational fluid dynamics(CFD) approach has been developed in order to evaluate the performance of inkjet print head and droplet control process are studied to reduce the deviations between nozzles which affect the size of the printed line for the industrial application of direct writing on printed circuit boards(PCB). 1D lumped model analysis shows that it is useful tool for evaluating performance of an inkjet head by varying the design parameters. The differences in ejected volume and droplet velocity between analytical and experimental result are within 12%. Time sequence of droplet generation is verified by the comparison between 3D analysis result and photographic images acquired by stroboscopic technique. In addition, by applying DPN process, velocity and volume uniformity between nozzles is dramatically improved that the tolerance achieved by the piezoelectric inkjet printhead across the 64 nozzles is 5 to 8%. A printed line pattern is successfully obtained using the fabricated inkjet print head and droplet calibration system.

  • PDF

IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM (Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도)

  • Kim, Bong-Chul;Lee, Chae-Eun;Park, Won-Se;Kang, Jeong-Wan;Yi, Choong-Kook;Lee, Sang-Hwy
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

Effect of frontal facial type and sex on preferred chin projection

  • Choi, Jin-Young;Kim, Taeyun;Kim, Hyung-Mo;Lee, Sang-Hoon;Cho, Il-sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-117
    • /
    • 2017
  • Objective: To investigate the effects of frontal facial type (FFT) and sex on preferred chin projection (CP) in three-dimensional (3D) facial images. Methods: Six 3D facial images were acquired using a 3D facial scanner (euryprosopic [Eury-FFT], mesoprosopic [Meso-FFT], and leptoprosopic [Lepto-FFT] for each sex). After normal CP in each 3D facial image was set to $10^{\circ}$ of the facial profile angle (glabella-subnasale-pogonion), CPs were morphed by gradations of $2^{\circ}$ from normal (moderately protrusive [$6^{\circ}$], slightly protrusive [$8^{\circ}$], slightly retrusive [$12^{\circ}$], and moderately retrusive [$14^{\circ}$]). Seventy-five dental students (48 men and 27 women) were asked to rate the CPs ($6^{\circ}$, $8^{\circ}$, $10^{\circ}$, $12^{\circ}$, and $14^{\circ}$) from the most to least preferred in each 3D image. Statistical analyses included the Kolmogorov-Smirnov test, Kruskal-Wallis test, and Bonferroni correction. Results: No significant difference was observed in the distribution of preferred CP in the same FFT between male and female evaluators. In Meso-FFT, the normal CP was the most preferred without any sex difference. However, in Eury-FFT, the slightly protrusive CP was favored in male 3D images, but the normal CP was preferred in female 3D images. In Lepto-FFT, the normal CP was favored in male 3D images, whereas the slightly retrusive CP was favored in female 3D images. The mean preferred CP angle differed significantly according to FFT (Eury-FFT: male, $8.7^{\circ}$, female, $9.9^{\circ}$; Meso-FFT: male, $9.8^{\circ}$, female, $10.7^{\circ}$; Lepto-FFT: male, $10.8^{\circ}$, female, $11.4^{\circ}$; p < 0.001). Conclusions: Our findings might serve as guidelines for setting the preferred CP according to FFT and sex.

A safe, stable, and convenient three-dimensional device for high Le Fort I osteotomy

  • Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.32.1-32.4
    • /
    • 2020
  • Background: Le Fort I osteotomy is a highly effective treatment for skeletal jaw deformities and is commonly performed. High Le Fort I osteotomy is a modified surgical procedure performed for improving the depression of the cheeks by setting the osteotomy higher than the conventional Le Fort I osteotomy. Developments in three-dimensional (3D) technology have popularized the use of 3D printers in various institutions, especially in orthognathic surgeries. In this study, we report a safe and inexpensive method of performing a high Le Fort I osteotomy using a novel 3D device and piezosurgery, which prevent tooth root injury without disturbing the operation field for patients with a short midface and long tooth roots. Results: A 17-year-old woman presented with facial asymmetry, mandibular protrusion, a short midface, and long tooth roots. We planned high Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. Prevention of damage to the roots of the teeth and the infraorbital nerve and accurate determination of the posterior osteotomy line were crucial for clinical success. Le Fort I osteotomy using 3D devices has been reported previously but were particularly large in size for this case. Additionally, setting the fixing screw of the device was difficult, because of the risk of damage to the roots of the teeth. Therefore, a different surgical technique, other than the conventional Le Fort I osteotomy and 3D device, was required. The left and right parts of the 3D device were fabricated separately, to prevent any interference in the surgical field. Further, the 3D device was designed to accurately cover the bone surface from the piriform aperture to the infra-zygomatic crest with two fixation points (the anterior nasal spine and the piriform aperture), which ensured stabilization of the 3D device. The device is thin and does not interfere with the surgical field. Safe and accurate surgical performance is possible using this device and piezosurgery. The roots of the teeth and the infraorbital nerve were unharmed during the surgery. Conclusions: This device is considerably smaller than conventional devices and is a simple, low-cost, and efficient method for performing accurate high Le Fort I osteotomy.

THE THREE DIMENSIONAL ANALYSIS OF VOLUMETRIC AIRWAY CHANGE IN ORTHOGNATHIC SURGERY OF MANDIBULAR PROGNATHISM (하악 전돌증 환자의 악교정 수술에서 기도 공간의 부피변화에 관한 3차원적 분석)

  • Lee, Jee-Ho;Paeng, Jun-Young;Myoung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.6
    • /
    • pp.552-558
    • /
    • 2005
  • Orthognathic surgery changes patient's mandibular position and environment of related anatomic structures. Many clinicians were interested in these changes and studied about this problem. However, most of them were based on two dimensional cephalogram. According to the development of image and computer system, it would be possible that the airway change is analyzed with three dimensional CT. So we tried to measure the volumetric change of airway and analyzed the relationship between the airway structure and volumetric change. Nineteen patients who experienced orthognathic surgery due to mandibular prognathism were analyzed with 3D CT data (preoperative and postoperative 6 months) and 2D lateral cephalometry. Volumetric change was measured and 3 dimensional change of related structure was assessed with simulation program ($V-works^{(R)}$, 4.0 Cybermed, Korea). Ten patients showed the decrease of airway volume change and nine showed the increase of airway volume change. Volumetric change was determined by dimensional change of mandible and hyoid bone. The dimensional positions of mandible and hyoid bone were the key factor for determining the airway change after surgery. Airway change is also predictable with the dimensional change of mandible and hyoid bone.