• Title/Summary/Keyword: 38kDa antigen

Search Result 23, Processing Time 0.02 seconds

Disulfide Bond Bridged Divalent Antibody-Toxin, $(Fab-PE38fl)_2$ with the Toxin PE38 Fused to the Light Chain

  • Won, Jae-Seon;Choe, Mu-Hyeon
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.8
    • /
    • pp.1475-1481
    • /
    • 2008
  • B3 antibody specifically binds the $Lewis^Y$-related carbohydrate antigen of many carcinomas, and it is used as a model antibody in this study. In a previous study, the Fab fragment of the antibody was fused to a 38 kDa truncated form of Pseudomonas exotoxin A, PE38, to make Fab-PE38, where PE38 is fused to the Fd fragment of the Fab domain. This parent monomer molecule, Fab-PE38, had no cysteine in the hinge region, and it could not make a disulfide bond to form a disulfide bond bridged homodimer. In this study, we constructed three different kinds of divalent Fab-toxin fusion homodimers where the toxin is fused to the light chain of Fab, $(Fab-PE38fl)_2$. In addition to the PE38 toxin fused to the light chain, these three molecules have different hinge sequences hi, h2, and h3 making Fabh1-, Fabh2-, and Fabh3-PE38fl monomers, respectively. These hinges contain only one cysteine on different positions of the hinge sequence. The disulfide bond between the hinge region of two monomers forms homodimers $(Fabh1-PE38fl)_2$, $(Fabh2-PE38fl)_2$, and $(Fabh3-PE38fl)_2$. The refolding yields of these dimers were 5-16-fold higher than a previously constructed dimer where the PE38 was fused to the Fd fragment $(Fabh2-PE38)_2$ [8]. Our data suggest that the steric repulsion between the two PE38s in $(Fabh1-PE38)_2$ during disulfide bridge formation is relieved by fusing it at the end of the light chain. The best cytotoxicity value of these dimers showed about 2.5-fold higher on an MCF7 cell line than that of the monovalent reference molecule in ng/ml scale, which is 15-fold higher in pM scale.

An Enzyme-Linked Immunosorbent Assay for Detection of Cooked Goat Meat (가열 염소육의 판별을 위한 효소면역측정법)

  • Kim, Hyun-Jung;Shon, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.538-543
    • /
    • 2000
  • This study was conducted to develop an enzyme-linked immunosorbent assay(ELISA) for the determination of cooked goat meat. Muscle proteins were extracted from goat meat by heating at $98^{\circ}C$ for 15 min. Major thermostable(TS) protein, whose size and pI are 36 and 38 kDa and 4.5 respectively, were purified by DEAE-Sephadex A-50 and Sephadex G-75 column chromatography. The TS protein was immunized into rabbits in order to produce goat specific antibodies. Competitive indirect ELISA(ciELISA) was established by using the anti-TS antibody. The antibody showed high reactivity toward the TS antigen and the boiled goat meat extract but it did not show any reactivities toward extracts of boiled chicken, pork, lamb, and beef. Thus, this ciELISA developed in this study could be applicable to identify goat species from cooked meat.

  • PDF

Comparative serological analysis of outer membrane proteins extracted from Brucella abortus Korean isolates and 1119-3 strains (Brucella abortus 국내 분리주의 세포외막 단백질 분석 및 혈청학적 비교)

  • Cha, Seung-Bin;Kang, Mi-Lan;Lee, Won-Jung;Shin, Min-Kyoung;Cho, Dong-Hee;Jung, Suk-Chan;Yoo, Han-Sang
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.4
    • /
    • pp.431-440
    • /
    • 2008
  • Brucellosis is one of the most important zoonosis in worldwide. As one of the control measures, attempts have been made to develop new diagnostic methods using filed isolates as a national policy in many countries. Currently, bovine brucellosis in Korea have been received attention in both public health and economical aspects due to sudden increase of outbreak. Based on the situation, we compared standard strain (B. abortus 1119-3) with field isolates to reveal the differences among them. Biological and biochemical charateristics, antibiotic resistance profiles, outer membrane proteins (OMPs) and lipopolysaccharide analysis of the strains were included in this study. For the diagnostic purpose, an attempt was made to find out a novel antigen from the Korean isolates by serological analysis. There were differences about 55 kDa, 36-38 kDa and 20 kDa in analysis of OMPs by SDS-PAGE and Western blot with positive sera ($\geq$ 1:400 in SAT titer). Also, a serological diagnostic method, ELISA was conducted using OMPs of the strains as novel antigen. Relationships between O.D. and SAT titer were analyzed using field sera showing different SAT titer. High correlation coefficient was observed between SAT titer and ELISA. Results from this study suggested that a new diagnsotic method should be developed using their own field isolates in each country.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

Evaluation of an ELISA kit for the Serodiagnosis of Pulmonary Tuberculosis by Using Mixed Antigens of Mycobacterium Tuberculosis (폐결핵진단에서 결핵균 혼합항원을 이용한 혈청학적 검사의 유용성에 관한연구)

  • Park, Seung-Kyu;Kim, Phil-Ho;Kim, Seung-Chul;Choi, In-Hwan;Cho, Sang-Nae;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.558-567
    • /
    • 2000
  • Background : Recently, serologic techniques for tuberculosis have been developed and some of them, which are focusing on detection of serum antibodies mainly directed against specific 38-kDa Mycobacterium tuberculosis, have already been introduced into the markel. In this study, diagnostic significance of a new serologic test(ELISA kit) for pulmonary tuberculosis was evaluated. Method : Serologic test with newly developed ELISA kit was performed upon 474 individuals, who include 333 active pulmonary tuberculosis patients, 80 healthy cases, and 61 tuberculosis contact cases. This serologic test was based on the ELISA technique and designed to detect antibodies to mixed complex antigens including 38-kDa, which were developed by Erume Biotech Co., Seoul. Active pulmonary tuberculosis was diagnosed by sputum AFB smear and culture methods. Results : The seropositivities using this ELISA kit were 82.1% and 73.6% in smear-positive and negative groups among active pulmonary tuberculosis, respectively. And, it also showed that seronegativities were 97.5% and 85.2% in healthy and contact groups, respectively. As a whole, the results of our study using the ELISA kit as a diagnostic method for pulmonary tuberculosis showed 80.0% sensitivity for active pulmonary tuberculosis, 97.5% specificity, 96.1% positive predictive value, and 65.0% negative predictive value when the prevalence of tuberuclosis in the samples was 60.1%. Conclusion : Our results reveal that the detection of antibody its reaction with 38-kDa antigen of M. tuberculosis is not sufficient to be accepted as single diagnostic method for pulmonary tuberculosis. However, they suggest that ELISA kit may be considered as an adjunctive test to standard diagnostic techniques of pulmonary tuberculosis.

  • PDF

Prevalence of autoantibodies that bind to kidney tissues in cats and association risk with antibodies to feline viral rhinotracheitis, calicivirus, and panleukopenia

  • Songaksorn, Nisakorn;Petsophonsakul, Wilaiwan;Pringproa, Kidsadagon;Lampang, Kannika Na;Sthitmatee, Nattawooti;Srifawattana, Nuttawan;Piyarungsri, Kakanang;Thongkorn, Kriangkrai
    • Journal of Veterinary Science
    • /
    • v.22 no.3
    • /
    • pp.38.1-38.17
    • /
    • 2021
  • Background: The feline viral rhinotracheitis, calicivirus, and panleukopenia (FVRCP) vaccine, prepared from viruses grown in the Crandell-Rees feline kidney cell line, can induce antibodies to cross-react with feline kidney tissues. Objectives: This study surveyed the prevalence of autoantibodies to feline kidney tissues and their association with the frequency of FVRCP vaccination. Methods: Serum samples and kidneys were collected from 156 live and 26 cadaveric cats. Antibodies that bind to kidney tissues and antibodies to the FVRCP antigen were determined by enzyme-linked immunosorbent assay (ELISA), and kidney-bound antibody patterns were investigated by examining immunofluorescence. Proteins recognized by antibodies were identified by Western blot analysis. Results: The prevalences of autoantibodies that bind to kidney tissues in cats were 41% and 13% by ELISA and immunofluorescence, respectively. Kidney-bound antibodies were observed at interstitial cells, apical border, and cytoplasm of proximal and distal tubules; the antibodies were bound to proteins with molecular weights of 40, 47, 38, and 20 kDa. There was no direct link between vaccination and anti-kidney antibodies, but positive antibodies to kidney tissues were significantly associated with the anti-FVRCP antibody. The odds ratio or association in finding the autoantibody in cats with the antibody to FVRCP was 2.8 times higher than that in cats without the antibody to FVRCP. Conclusions: These preliminary results demonstrate an association between anti-FVRCP and anti-cat kidney tissues. However, an increase in the risk of inducing kidney-bound antibodies by repeat vaccinations could not be shown directly. It will be interesting to expand the sample size and follow-up on whether these autoantibodies can lead to kidney function impairment.

Differentiation of Entomoeba histolyticn and Entcmoeba dispor in cyst-passers by immunoblot (면역이적법을 이용한 아질아메바와 동형아메바의 감별진단)

  • 이미정;홍성태
    • Parasites, Hosts and Diseases
    • /
    • v.34 no.4
    • /
    • pp.247-254
    • /
    • 1996
  • Differentiation of invasive strains of Entamoebn histolytica according to their pathogenicity has been a topic of long debate, but now the pathogenic species only is regarded as E. histolytica while the non-pathogenic species is E. dispar. The present study applied immunoblot to differentiale infections of the two species among microscopically- detected cyst-passers in Korea. The crude extract of 5. histolyticn separated in 5-20% gradient gels, revealed many fractions of 94. 81. 71, 50. 44, 38.5. 37.5, 29, 19. and 18 kDa when the cysteine proteinase inhibitor. E64, was supplemented. The serum IgG antibody of 3 proven E. histolytirc cases reacted loth the antigenic fractions of 117. 110. 99.68,66,60.54.52, 46. and 45 kDa. Sera of PCR confirmed 3 cases of E. disper reacted only to the 117 kDa fraction or the E. histolytica crude extract which was regarded as non specific. To the antitigen of monoxenic E. dispar. sera or E. dispar and E. histolytica cases showed the same immunoblot reactions. The serum IgG antibody reacted with several antigenic fractions of both E. histolytica and E. dispar. but IgM and IgE antibodies showed no reaction to either antigen. Sera of 24 symptomless amebic cyst-passers were screened with the E. histolytica alltigen; two were found to be infected by E. histolytica and 22 were by E. dispar. The present findings suggest that in Korea most of asymptomatic cyst passers of E. histolytica are carriers of E. dispar. Immunoblot using E. histolytica antigen is a good technique for the differentiation of E. histolytica and E. dispar infections.

  • PDF

Development of Test System for Detection of Antibody to Human Immunodeficiency Virus Type 1 Subtype O (HIV-1 O형 항체 진단시료의 개발)

  • Cho, Young-Shik;Yu, Seung-Shin;Ha, Gun-Woo;Lee, Sang-Gook;Cho, Myung-Hwan;Shin, Hyung-Sik;Kim, Sun-Young
    • The Journal of Korean Society of Virology
    • /
    • v.28 no.1
    • /
    • pp.31-38
    • /
    • 1998
  • In Korea, all domestic made test systems for detecting antibodies in HIV-1 contain the antigens from human immunodeficiency type 1 (HIV-1) subtype B. However, because HIV-1 subtype O is significantly different in amino acid sequences from all other subtypes of HIV-1, there has been a need for developing a test for detecting antibodies in subtype O. For this purpose, the entire nucleotide sequence corresponding to the extracellular domain of the transmembrane glycoprotein of HIV-1 subtype O was synthesized with consideration of Escherichia coli condon usage. Various regions of the extracellular domain were cloned into E. coli expression vectors and tested for levels of protein production. The nucleotide sequence, named ECTM, that can encode a 129 amino acid-long peptide, was found to be expressed at a high level in E. coli. The protein of approximately 17 kDa specifically reacted with sera from individuals infected with HIV-1 subtype O. The ECTM protein was purified to near homogeneity by the CM-T gel chromatography, using concentrated, denatured inclusion bodies. In Western blot analysis, the purified viral antigen reacted with sera from individuals infected with subtype O more efficiently than subtype B. The enzyme linked immunoabsorbent assay (ELISA) system was developed using the subtype O viral protein and compared with the commercially available kit lacking the antigens from subtype O. The ELISA kit containing the subtype O antigen ECTM alone efficiently reacted with sera from individuals infected with subtype O. The subtype O antigen-containing kit produced a positive absorbence even when sera were diluted 512-fold, suggesting a high sensitivity. The commercially available kit also reacted with subtype O sera, but produced a negative result at a dilution of 8-fold. Our results suggest that the currently available kit may not be able to efficiently detect subtype O sera and that the viral protein developed in this study may be added to the current system to maximize the detection of sera from individuals infected with subtype O.

  • PDF

Evaluating the Usefulness of the ICT Tuberculosis Test Kit for the Diagnosis of Tuberculosis (결핵 진단에서 ICT Tuberculosis Test Kit의 효용성)

  • Chang, Chul-Hun;Son, Han-Chul;Ryu, Ki-Chan;Park, Soon-Kew;Lee, Seon-Ho;Kim, Sung-Ryul;Park, Ki-Hyung;Kim, Woo-Seok;Koo, Kyong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.473-480
    • /
    • 1999
  • Background: Early diagnosis of tuberculosis is critical, especially in Korea, an area where tuberculosis is endemic. Because antibody responses to some membrane proteins of Mycobacterium tuberculosis are not comparable, and the policy of BCG vaccination and the prevalence of tuberculosis are different from country to country, the usefulness of the serological diagnostic tests is questionable in Korea, even though they have been confirmed to be useful in other countries. In the specific context of Korea, we tried to evaluate the validity of the ICT Tuberculosis Test (ICT), a membrane-based antibody kit that purports to detect the 5 M. tuberculosis complex-specific antigens including 38-kDa protein. Method: 68 patients with tuberculosis were tested : 37 had no history of previous tuberculosis, and 31 were reactivated cases. The control group comprised 77 subjects : 25 healthy adults, 35 hospital workers with frequent contact with tuberculosis patients, and 17 in-patients with non-tuberculous respiratory diseases. Results: The diagnostic sensitivities of the ICT were 87% and 73% in patients with versus without previous history of tuberculosis, respectively. The sensitivities of smear-positive and smear-negative patient groups were 81% and 73%, respectively. Both of the two patients with extrapulmonary tuberculosis tested positive through the ICT. The specificities of the ICT were 88%, 94%, and 94% in healthy adults, hospital workers, and non-tuberculous patients, respectively, with an overall specificity of 92%. Conclusion: It is suggested that when combined with traditional techniques, the ICT is an useful tool for the diagnosis of pulmonary tuberculosis. The procedure is simple, easy to perform, rapid, and needs no equipment. It shows 73% sensitivity and 92% specificity for the diagnosis of tuberculosis.

  • PDF

The Clinical Significance of STAT-PAK ULTRA FAST$^{(R)}$ and ICT Tuberculosis$^{(R)}$ for Serologic Diagnosis of Tuberculosis (폐결핵 진단을 위한 STAT-PAK ULTRA FAST$^{(R)}$와 ICT Tuberculosis$^{(R)}$의 유용성에 관한 연구)

  • Kim, Geun-Hwa;Park, Hee-Sun;Kim, Myung-Hoon;Kang, Dong-Won;Lee, Kyu-Seung;Ko, Dong-Seok;Suh, Jae-Chul;Jeong, Seong-Su;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.311-320
    • /
    • 1999
  • Background: In recent years, tuberculosis has re-emerged as a major health problem in both industrialized & developing countries. Recent advances in identifying & purifying antigens secreted in active tuberculosis infection have lead to the development of serological assays based on a number of immunodominant antigens. To date, the most sensitive and specific of these antigens has been the 38-kDa antigen. Method: Two rapid membrane-based serologic assays using antigen(38-kDa) from mycobacterium tuberculosis for the diagnosis of tuberculosis were evaluated in 22 patients with smear-positive pulmonary tuberculosis, 14 patients with inactive pulmonary tuberculosis, and 9 patients with non-tuberculous lung disease. Result: The evaluation of validity(sensitivity, specificity, positive predictive value, negative predictive value, false positivity and false negativity) of STAT-PAK ULTRA FAST$^{(R)}$ were 77.3%, 28.6%, 63.0%, 44.4%, 71.4 %, and 22.7% for differential diagnosis of active pulmonary tuberculosis and inactive pulmonary tuberculosis, respectively. The evaluation of validity of STAT-PAK ULTRA FAST$^{(R)}$ were 77.3%, 33.3%, 73.9%, 37.5%, 66.7%, and 22.7% for differential diagnosis of active pulmonary tuberculosis and non-tuberculosis. The evaluation of validity of ICT Tuberculosis$^{(R)}$ were 54.5%, 57%, 66.7%, 44.4%, 42.9%, and 45.5% for differential diagnosis of active pulmonary tuberculosis and inactive pulmonary tuberculosis. The evaluation of validity of ICT Tuberculosis$^{(R)}$ were 54.5%, 100%, 100%, 47.4%, 0%, and 45.4% for differential diagnosis of active pulmonary tuberculosis and non-tuberculosis. Conclusion: We concluded no effectiveness of STAT-PAK ULTRA FAST$^{(R)}$ & ICT tuberculosis$^{(R)}$on serologic diagnosis of pulmonary tuberculosis. In the future, further large-scale study should be needed for serologic diagnosis of pulmonary tuberculosis.

  • PDF