• Title/Summary/Keyword: 3-mask

Search Result 1,000, Processing Time 0.025 seconds

Inhibitory Activity of Pesticide-preventing Active Carbon Fiber Mask on the Penetration of Pesticide and its Inhibitory Effect on Acute Inhalation Toxicity in Rats (탄소섬유 방제 마스크의 농약차단효과 및 흰쥐의 급성 흡입독성 예방효과)

  • Kim, Chang-Jong;Choi, Hyun-Ho;Shim, Sang-Soo;Shin, Hwa-Woo
    • YAKHAK HOEJI
    • /
    • v.42 no.4
    • /
    • pp.447-458
    • /
    • 1998
  • Inhibitory activity of pesticide-preventing active carbon fiber mask on the penetrations in pesticide spray and its inhibitory effect on acute inhalation toxicity in rats were s tudied. Pesticides were sprayed into box ($1.O{\times}1.2{\tmies}O.6\;m$) at a dose of 20ml/min of diazinon ($Diatone^{TM}$) suspension (340ppm) and 5g/min of BPMC powder (2.0%) for 4 hours, and then captured the penetrated pesticides into water via mask in box under 8l/sec suction. The pesticides were analysed by A.O.A.C. method and GC/MS. Pesticide-preventing active carbon fiber mask significantly inhibited the penetration of diazinon by 93.4% as compared with control, and cotton mask and pesticide-preventing mask did it by 74.2% and 83.7%,respectively. This result shows that pesticide-preventing active carbon fiber mask has the most prominent inhibitory effect in preventing the penetration of diazinone. In the penetration of BPMC, all of three masks, such as active carbon fiber mask, cotton mask and pesticide-preventing mask, have a similar inhibitory effect, which were 99.3%, 98.6% and 97.0%, respectively. The penetrated pesticides via pesticide-preventmg active carbon fiber mask did not exert acute inhalation toxicity.

  • PDF

A Study on Model for Drivable Area Segmentation based on Deep Learning (딥러닝 기반의 주행가능 영역 추출 모델에 관한 연구)

  • Jeon, Hyo-jin;Cho, Soo-sun
    • Journal of Internet Computing and Services
    • /
    • v.20 no.5
    • /
    • pp.105-111
    • /
    • 2019
  • Core technologies that lead the Fourth Industrial Revolution era, such as artificial intelligence, big data, and autonomous driving, are implemented and serviced through the rapid development of computing power and hyper-connected networks based on the Internet of Things. In this paper, we implement two different models for drivable area segmentation in various environment, and propose a better model by comparing the results. The models for drivable area segmentation are using DeepLab V3+ and Mask R-CNN, which have great performances in the field of image segmentation and are used in many studies in autonomous driving technology. For driving information in various environment, we use BDD dataset which provides driving videos and images in various weather conditions and day&night time. The result of two different models shows that Mask R-CNN has higher performance with 68.33% IoU than DeepLab V3+ with 48.97% IoU. In addition, the result of visual inspection of drivable area segmentation on driving image, the accuracy of Mask R-CNN is 83% and DeepLab V3+ is 69%. It indicates Mask R-CNN is more efficient than DeepLab V3+ in drivable area segmentation.

RETROSPECTIVE STUDY OF FACE MASK THERAPY (FACE MASK의 치료 효과에 대한 후향적 고찰)

  • Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.547-556
    • /
    • 1996
  • The purpose of this study was to evaluate the skeletal, dental and soft tissue profile changes following the face mask therapy in growing skeletal class III malocclusion patients. The fifteen patients with the good results were selected among the patients who visited the Department of Orthodontics in Seoul National University Hospital. The mean age was 10.63(range 7.25-13.25) years and the mean treatment duration was 9.84(range 2.00-27.00) months. Lateral cephalograms were taken just before and after face mask application. After tracing the cephalograms, thirty five items(twety angular and fifteen linear) were measured. The differences before and after the face mask therapy were compared statistically by the paired t-test(p<0.05). The results were as follows : SNA and Co-A(effective maxillary length) increased significantly after using the face mask(p<0.001), which reflects the orthopedic changes of maxilla. SNB and Co-Gn(effective mandibular length) also showed an increase(p<0.01), which may be a result of the strong growth trends of the samples. FMA, SN-GoGn and Y-axis angle increased significantly(p<0.01), which means the backward and downward rotation of the mandible. This positional change seemed to have compensated an increase of effective mandibular length. There was no statistically significant difference in angulation of upper and lower incisors between pre-treatment and post-treatment(p>0.05). In soft tissue profile, the upper lip was positioned anteriorly(p<0.01) after treatment and approximated to the normal standards.

  • PDF

Development of a Low Noisy Type of Air-line Mask (저소음형 송기마스크 개발)

  • Paik, Eun-Gyu;Kim, Bong-Nyun;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.277-281
    • /
    • 2005
  • Air-line mask is an important personal protective equipment for workers working under hazardous surroundings in which a fixed ventilation system is difficult to be installed. If the air-line mask make loud noise, works wearing the mask may be faced with health problems such as noise induced hearing loss(NIHL). The purpose of this study is to introduce a low noisy technology for workers using air-line mask. A traditional type air-line has been improved to an advanced air-line mask with lesser noise. In the mask, air suppling conduits consists of multi tubes are placed inside of the front of the safety helmet. The noise level reduced from 80dB(A) to less than 80dB(A) when measured by KS A 0701 method at Center for Safety Inspection, Testing and Certification for KOSHA. It is suitable for related regulation[Article 35 of the Industrial Safety and Health Act(Test of Personal Protective Equipment)]. While workers working in noise level of over 90dB(A), they may expose to 82dB(A) or less when they wear the advanced masks. This type masks can be an alternative for works suffering from loud noise generated by traditional air-line masks.

A Study on the Stage-Structure of the Korean Traditional Mask Drama (가면극(假面劇)의 고유무대(固有舞臺) 구성(構成)에 관(關)한 연구(硏究))

  • Pahk, Kyung-Rip
    • Journal of Industrial Technology
    • /
    • v.1
    • /
    • pp.3-8
    • /
    • 1981
  • The aim of the study is to find out the proper stage of the Korean traditional Mask Drama. For this purpose, the study investigates into the traditional Mask Dramas representative in Korea. It discusses the nature and the form of the stage of them, and through the analysis of the stage, extracts a unique elements for the stage of the traditional Mask Drama.

  • PDF

A Study on Optimization of Mask Filter and Reduction in Respiratory Resistance (마스크 필터의 효율 최적화 및 호흡 저항 감소에 관한 연구)

  • Kwon, Sehyun;Hong, Jayoung;Jeong, Sang Bin;Heo, Ki Joon;Lee, Byung Uk
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.103-107
    • /
    • 2016
  • We conducted experiments on mask filters. We measured filtering efficiencies of several new mask filters which were manufactured by disassembling and reassembling of one type of mask filter. New filter (A+C: combination of the first layer and the third layer of the tested mask filter) showed the highest efficiency (97.7%) with the respiratory resistance of 98 pa.

Comparison of Environmental Evaluation for Paper and Plastic Based Mask Packaging (종이 기반과 플라스틱 기반 보건마스크 패키징의 환경영향 비교)

  • Dongho Kang;Youjin Go;Sanghoon Oh;Gohyun Choo;Jisoo Jang;Junhyuk Lee;Jinkie Shim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.30 no.1
    • /
    • pp.73-83
    • /
    • 2024
  • In this study, environmental evaluation of high barrier coated paper (coating layer/paper) packaging is conducted in comparison with conventional aluminum laminated (PET/VMPET/LLDPE) plastic packaging. The target product for this packaging is a KF94 mask, which requires a high barrier of water and oxygen to maintain the filtration ability of the mask filter. The functional unit of this study is 10,000 mask packaging materials based on a material capable of blocking oxygen (<1 g/m2day) and moisture (<3 g/m2day) for the preservation of KF94 masks. In order to understand the results easily, paper-based mask packaging system divided into 6 stages (pulp, pulping & paper making, calendaring & coating, printing, packing and waste management), while plastic-based mask packaging consists of 5 stages (material production, processing, printing, packing, waste management) In case of paper-based mask packaging, most contributing stage is calendaring & coating, resulting from heat and electricity production. On the other hand, plastic-based mask packaging is contributed more than 30% by material production, specifically due to linear low density polyethylene and purified terephthalic acid production. The comparison results show that global warming potential of paper-based mask packaging has 32% lower than that of plastic-based mask packaging. Most of other impact indicators revealed in similar trend.

Development of physically based 3D computer simulation code TRICSI for ion implantation into crystalline silicon

  • Son, Myung-Sik;Lee, Jun-Ha;Hwang, Ho-Jung
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • A new three-dimensional (3D) Monte Carlo ion implantation simulator, TRICSI, has been developed to investigate 3D mask effects in the typical mask structure for ion implantation into crystalline silicon. We present the mask corner and mask size effects of implanted boron range profiles, and also show the calculated damage distributions by applying the modified Kinchin-Pease equation in the single-crystal silicon target. The simulator calculates accurately and efficiently the implanted-boron range profiles under the relatively large implanted area, using a newly developed search algorithm for the collision partner in the single-crystal silicon. All of the typical implant parameters such as dose, tilt and rotation angles, in addition to energy can be used for the 3D simulation of ion implantation.

GaN Grown Using Ti Metal Mask by HVPE(Hydride Vapor Phase Epitaxiy) (HVPE(Hydride Vapor Phase Epitaxiy) 성장법으로 Ti metal mask를 이용한 GaN 성장연구)

  • Kim, Dong-Sik
    • 전자공학회논문지 IE
    • /
    • v.48 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • The epitaxial GaN layer of $120{\mu}m$ ~ $300{\mu}m$ thickness with a stripe Ti mask pattern is performed by hydride vapor phase epitaxy(HVPE). Ti strpie mask pattern is deposited by DC magnetron sputter on GaN epitaxial layer of $3{\mu}m$ thickness is grown by hydride vapor phase epitaxy(HVPE). Void are observed at point of Ti mask pattern when GaN layer is investigated by scanning electron microscope. The Crack of GaN layer is observed according to void when it is grown more thick GaN layer. The full width at half maximum of peak which is measured by X-ray diffraction is about 188 arcsec. It is not affected its crystallization by Ti meterial when GaN layer is overgrown on Ti stripe mask pattern according as it is measure FWHM of overgrowth GaN using Ti material against FWHM of first growth GaN epitaxial layer.

Three-dimensional monte carlo simulation and mask effect of low-energy boron ion implantation into <100>single-crystal silicon (<100>방향 실리콘 단결정에서의 저 에너지 붕소 이온 주입 공정에 대한 3차원 몬테 카를로 시뮬레이션 및 마스크 효과)

  • 손명식;이준하;송영진;황호정
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.8
    • /
    • pp.94-106
    • /
    • 1995
  • A three-dimensional(3D) Monte Carlo simulator for boron ion implantation into <100>single-crystal silicon considering the mask structure has been developed to predict the mask-dependent impurity doping profiles of the implanted boron at low energies into the reduced area according to the trend of a reduction in the size of semiconductor devices. All relevant important parameters during ion implantation have been taken into account in this simulator. These are incident energy, tilt and rotation of wafer, orientation of silicon wafer, presence of native silicon dioxide layer, dose, wafer temperature, ion beam divergence, masking thickness, and size and structure of open window in the mask. The one-dimensional(1D) results obtained by using the 3D simulator have been compared with the SIMS experiments to demonstrate its capabilities and confirem its reliability, and we obtained relatively accurate 1D doping profiles. Through these 3D simulations considering the hole structure and its size, we found the mask effects during boron ion implantation process.

  • PDF