• Title/Summary/Keyword: 3-dimensional CT

검색결과 591건 처리시간 0.028초

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • 제53권5호
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

흉골에 단독 전이된 유방암의 삼차원 입체조형 방사선 치료 성적 (Results of Three-Dimensional Conformal Radiation Therapy for the Treatment of a Solitary Sternal Relapse of Breast Cancer)

  • 김해영;허승재;박원;최두호;강민규;양정현;남석진;임영혁
    • Radiation Oncology Journal
    • /
    • 제26권2호
    • /
    • pp.91-95
    • /
    • 2008
  • 목적: 본 연구는 흉골에 단독 전이된 유방암 환자들에 대하여 삼차원 입체조형 방사선요법을 적용한 치료 성적에 대해 알아보고자 하였다. 대상 및 방법: 1996년 5월부터 2005년 6월까지 유방암의 흉골 단독 전이 병변에 대해 구제적 방사선 치료를 받은 17명의 환자를 분석하였다. 방사선 치료 범위는 종양으로부터 2 cm 여유를 두었으며 치료 선량은 하루 $1.8{\sim}3$ Gy로 총 $35.0{\sim}61.5$ Gy이었다. 종양 반응은 방사선 치료 종료 후 $1{\sim}3$개월에 시행한 컴퓨터 전산화 단층촬영영상으로 평가하였다. 결과: 전체 환자 중, 5명이 완전반응을, 12명이 부분반응을 보여, 모든 환자들이 방사선 치료에 객관적 반응을 보였다. 환자들의 5년 생존율은 51.9%, 중앙 생존기간은 27개월이었다. 환자들의 생존율은 유방암의 초기 수술일로부터 흉골 전이가 발견되기까지의 무병 생존기간에 영향을 받았는데, 무병 생존기간이 12개월 이상인 환자들의 5년 생존율은 61.8%이었던 반면, 무병 생존기간이 12개월 미만인 환자들의 5년 생존율은 0.0%였다(p=0.03). 결론: 흉골에 단독 전이된 유방암 환자들의 방사선 치료에 대한 반응은 우수하였다. 유방암의 초기 수술로부터 흉골재발이 발생하기까지의 무병 생존기간이 긴 환자에서 방사선 치료 후 생존율이 양호한 것으로 나타났다.

나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가 (Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy)

  • 박수연;채문기;임준택;권동열;김학준;정은아;김종식
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.93-109
    • /
    • 2020
  • 목 적: 나선형 토모테라피 방사선치료를 위한 환자별 품질관리용 라디오크로믹 필름 및 3차원 분석시스템인 Dosimetry CheckTM (DC, MathResolutions, USA)의 성능평가를 시행하였다. 대상 및 방법: 인체모형팬톰(Anderson Rando Phantom, USA)을 이용하여 위치 변이가 있는 3가지 형태의 복부 종양(130.6㎤), 복막 후면 종양(849.0㎤) 및 전 복부 전이 종양(3131.0㎤)을 모델링하였다. 조사면 고정너비(field width, FW)를 2.5-cm, 5.0-cm, 피치(pitch) 0.287, 0.43으로 하여 부위별 4개씩(plan01-plan04), 총 12개의 비교용 치료계획을 수립하였다. 이온전리함(1D)과 라디오크로믹 필름(Gafchromic EBT3, Ashland Advanced Materials, USA)을 치즈팬톰 내 삽입하는 방법(2D)과 빔 플루언스 로그정보를 이용하여 CT영상 위에 선량을 3차원으로 재구성하는 방식의 DC측정을 진행하였다. 스레드효과(thread effect)를 분석을 위해 리플(ripple) 진폭(%)를 계산하였고, 선량 분포의 패턴 분석을 위해 감마인덱스 분석(DD: 3%/DTA: 3mm, 합격 문턱 값: 95%)을 수행하였다. 결 과: 리플 진폭 측정 결과 복막 후면 종양이 평균 23.1%로 가장 높았다. 라디오크로믹 필름의 분석결과, 절대 선량 평균 1.0±0.9%, 감마인덱스분석 평균 96.4±2.2%로 95% 이상 통과하였으나 전 복부 전이 종양과 같이 넓은 부위 평가에 범위의 제한적이었다. 인체모형팬톰에 적용한 DC 분석결과 FW가 5.0-cm인 세 부위의 2D 및 3D 플랜 평균이 91.8±6.4%였다. 세 단면 및 선량 프로파일 분석을 통해 복막 후면 및 전 복부 종양 표적 전체 영역에 분석이 가능하였고, 선량-용적 히스토그램을 통한 계획 선량 대 측정의 선량 오차가 FW 및 pitch에 따라 커지는 것을 확인하였다. 결 론: DC측정방법은 별도의 측정기 없이 조사 중 측정된 빔 플루언스 로그정보만으로 3차원 환자 영상 데이터 위에 선량 오류를 구현할 수 있고 종양의 위치나 크기에 제한이 없어 크고 불규칙한 종양의 나선형 토모테라피의 치료 시 환자별 품질관리 성능이 매우 우수하며 활용도가 높을 것으로 생각한다.

국소진행성 직장암의 수술 전 동시화학방사선요법의 결과 (Results of Preoperative Concurrent Chemoradiotherapy for Locally Advanced Rectal Cancer)

  • 최상규;김수산;배훈식
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.34-42
    • /
    • 2007
  • 목 적: 국소적으로 진행된 직장암환자에서 수술 전 동시화학방사선요법을 시행한 환자들의 항문 괄약근 보존율과 병기 강하율 등을 분석하고자 후향적 임상 연구를 시행하였다. 대상 및 방법: 2002년 1월부터 2005년 12월까지 조직학적으로 확진된 직장암 환자 중, 병기가 T2 이상이거나 림프절 전이가 있는 환자를 대상으로 하였다. 한림대학교 성심병원 방사선종양학과에서 수술 전 동시화학방사선요법을 시행 받은 36명 중, 본원에서 수술을 시행한 26명을 대상으로 연구를 시행하였다. 환자들은 수술 전 병기결정을 위한 검사를 시행하였고 방사선치료는 CT를 촬영하여 치료계획을 세웠으며 매일 1.8 Gy로 주 5회, 총 방사선 조사량 $45.0{\sim}52.2\;Gy$까지 3차원 방사선치료 방법으로 시행하였으며, 방사선치료 첫째 주와 다섯째 주에 5-FU와 leucovorine을 동시 투여하였다. 수술은 동시화학방사선요법 종료 후 약 $2{\sim}4$주경에 시행하였다. 결 과: 대상 환자의 연령 중앙값은 61.9세($34{\sim}78$)였으며, 남자가 21명, 여자가 5명이었고 추적 관찰 기간의 중앙값은 28개월($11{\sim}44$)이었다. 모든 환자에서 절제연 음성인 근치절제가 가능하였으나 병리적으로 완전 반응을 보인 경우는 없었다. 수술은 3예에서 복회음부 절제술을, 나머지 23예에서 하전방절제술이 시행되어 괄약근 보존율은 88.5% (23/26)였다. 수술 후 병기 강하는 12예로 병기 강하율은 46.2%였으며 19예에서 종양 크기가 감소되어 종양크기 감소율은 73%였다. 국소 재발이 1명, 원격 전이가 3명에서 관찰되었으며 3년 무재발 생존율은 96.7%, 3년 무전이 생존율은 87%, 그리고 3년 무진행 생존율은 83.1%였다. 치료와 관련된 급성 독성으로는 Grade 3 & 4 빈혈 각각 1예, Grade 3 백혈구 감소증 1예, Grade 3 장폐색 1예가 관찰되었다. 결 론: 직장암 환자들에서 수술 전 동시화학방사선요법은 근치적 수술을 시행한 경우 높은 괄약근보존율과 수술 후 병기감소율을 보였으며 치료에 따른 독성도 대부분 경미하고 높은 순응도를 보여 효과적인 방법으로 판단되며 앞으로 많은 환자들을 대상으로 장기간에 걸친 추적 관찰을 요한다.

미니스크류 식립 각도 및 부위에 대한 3차원적 연구 (Three Dimensional Study of Miniscrew about Installation Area and Angle)

  • 조희상;이진우
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.203-211
    • /
    • 2008
  • 교정치료에서 고정원의 조절은 치료목적을 달성하기 위한 중요한 고려사항이다. 최근 골에서 쉽게 지지를 얻을 수 있는 미니스크류가 개발되고 발전되어 많은 치료에서 사용되고 있는데, 이러한 미니스크류는 해부학적 구조물들의 손상을 최소화 하면서 안전하게 식립하는 것이 매우 중요하다. 이에 본 연구는 전산화단층촬영 사진을 이용하여 임상적으로 미니스크류를 흔하게 심는 부위이면서 초기 고정이 약한 상악 구치부 협측 부위의 안전성을 평가하고, 식립 각도에 따른 인접치아에 대한 손상가능성을 평가 하고자 하였다. 상악 구치부 협측에서 $1.2{\times}6.0mm$의 미니스크류를 식립하게 되면 일반적으로 CEJ에서 5~8mm 상방에 그리고 피질골 표면에서 3~5mm 내측에 미니스크류의 끝이 위치하게 된다. 이 경우 각 치근 사이의 면적을 측정하였다. 또한 식립각도를 30도, 45도, 60도로 나누어 식립 각도별 치근 사이의 길이를 측정하였다. 대구치와 대구치 사이, 대구치와 소구치 사이, 소구치와 소구치 사이의 3그룹으로 나누어 다음과 같은 결과를 얻었다. 1) 식립부위에 따른 비교에서 제1대구치와 제2대구치 사이에서 치간골의 면적이 유의하게 작았다. 2) 각도에 따른 비교에서 대구치 사이와 소구치와 대구치 사이에서는 더 기울여 식립 하는 것이 안전함을 보였으나, 소구치 사이에서는 식립 각도가 안전성에 크게 영향을 주지 못했다. 이상의 결과를 바탕으로 미니스크류를 식립 할 경우 대구치 사이보다는 대구치와 소구치 사이 또는 소구치 사이가 상대적으로 안전한 부위라는 것을 알 수 있었다. 그리고 대구치 사이와 대구치와 소구치 사이에 식립 할 경우에는 식립 각도가 증가 할수록 안전하다는 것을 알 수 있었다.

3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성 (Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images)

  • 정호걸;김기덕;한승호;허경석;이제범;박혁;최성호;김종관;박창서
    • Imaging Science in Dentistry
    • /
    • 제36권2호
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측 (Measurement of facial soft tissues thickness using 3D computed tomographic images)

  • 정호걸;김기덕;한승호;신동원;허경석;이제범;박혁;박창서
    • Imaging Science in Dentistry
    • /
    • 제36권1호
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

유방암 환자의 방사선 치료시 Energy와 Wedge를 combine한 Hybrid plan의 유용성 평가 (Usefulness evaluation of Hybrid planning through dosimetric comparision of Three Dimensinal Conformal Radiation Radiotherapy and Hybrid planning for left breast cancer)

  • 채문기;박병수;안종호;송기원
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.91-98
    • /
    • 2014
  • 목 적 : 본 연구에서는 기존의 방사선 치료 기법인 3D-CRT 방법을 기반으로 치료 Energy와 Wedge를 변형 시킨 Hybrid 치료계획을 세워, open rectangular field를 사용한 2D-RT와 현재 가장 많이 시행되고 있는 방사선치료의 형태인 3D-CRT, 그리고 Hyrid paln 의 각각의 치료계획에 따른 선량분포, 선량-체적 히스토그램을 이용하여 산출된 값들을 비교, 분석하여 Hybrid 치료계획의 유용성을 평가하고자 한다. 대상 및 방법 : 본원에서 방사선 치료를 받은 환자 5명을 대상으로 전산화 단층촬영장치(RT-16GE)를 이용해 CT모의치료를 시행하여 영상을 획득하였다. 치료계획실에서는 이미지 관심영역표시는 종양은 CTV으로, 정상장기는 폐, 심장으로 나타냈다. 치료계획은(pinncle-ver 9.2)은 표적에는 충분한 선량을 정상장기에는 선량이 최소화 되도록 치료계획을 세웠다. 결 과 : Homogeneity Index의 선량비교는 2D-RT (open rectangular field): 38.32, TW(conformal wedge field): 32.01 FIF(field in field): 29.22, HYBRID(energy combine, wedge combine): 30.57으로 나타났다. 2D-RT, TW, FIF Hybrid $V_{75_-lung}$은 각각 112.33, 125.14, 121.3, 123.78. $V_{50_-lung}$은 155.43, 159.62, 157.96, 159.06. $V_{25_-lung}$은 199.86, 200.22, 198.65, 200.31. $V_{50_-heart}$는 각각 26.07, 27.1, 26.85, 27.17 $V_{30_-heart}$ 33.71, 34.37, 34.15, 34.65로 나타났다. 결 론 : HYBRID planning에서 표적에는 3D-CRT 에 비해 비교적 뛰어난 선량분포와 유방을 보호함을 보여주지만 폐와 심장에 많은 선량이 조사됨을 치료계획 시 주의해야 하고 앞으로 해결해야 할 과제라 생각된다. HYBRID 으로 Energy를 혼합하여 사용한다면, 타겟에 보다 더 적절한 coverage가 이루어질 수 있을 것으로 보인다. breast 뿐만 아닌 Lung cacner 치료와 같이 불균질한 부위의 치료에 적용한다면 보다 더 최적을 결과를 이루어낼 수 있을 것으로 사료된다.

3차원 광학 스캐너와 콘빔CT에서 생성된 디지털 모형의 비교 (Comparison of digital models generated from three-dimensional optical scanner and cone beam computed tomography)

  • 권혁진;김각균;이원진
    • 구강회복응용과학지
    • /
    • 제32권1호
    • /
    • pp.60-69
    • /
    • 2016
  • 목적: 본 연구에서는 실제 환자의 석고모형의 콘빔CT (Cone Beam Computed Tomography)이미지로 디지털 모델을 제작하고 이 디지털 모델을 동일한 석고모형을 3차원 광학 스캐너로 스캔 하여 얻은 디지털 모델과 비교하였다. 연구 재료 및 방법: 총 11쌍의 석고모형에 대하여 실험을 진행 하였다. 콘빔CT를 이용하여 CT 영상을 촬영하여 디지털 모델을 제작 하였고 3차원 광학 스캐너를 사용해 대조군이 되는 디지털 모델을 제작하였다. 이를 이용해 각 석고모형에 대하여 콘빔CT와 3차원 광학 스캐너를 이용하여 만든 디지털 모델을 한 쌍으로 묶어 상, 하악 11개의 비교 쌍을 구성하고 각 쌍에 대하여 차이점을 분석하였다. 결과: 대조군과 비교 시 콘빔CT 영상으로부터 구성된 디지털 모델이 대조군 보다 과다 추정된 부분인 양의 오차의 평균은 0.059 - 0.117 mm, 과소 추정된 부분인 음의 오차의 평균은 0.066 - 0.146 mm의 범위 내에 존재했다. 또한 유의수준 0.05에서 양의 오차의 평균은 $70-100{\mu}m$, 음의 오차의 평균은 $100-120{\mu}m$ 내에 존재 함을 확인하였다. 결론: 석고모형의 콘빔CT 영상으로부터 구성된 디지털 모델은 최종 수복물 제작에는 부적합하나 임시수복물 제작 및 교정 진단 과정에 활용될 수 있는 가능성이 있다.

폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가 (Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy)

  • 장형준;이영규;김영재;박영규
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.87-99
    • /
    • 2016
  • 목 적 : 종양의 위치에 따라 단일에너지를 이용한 치료계획과 이중에너지를 사용하는 치료계획을 정위적방사선 치료에 적용하여 실제 종양에 부여되는 선량의 변화와 종양과 인접한 부분에 위치하는 정상조직의 선량을 비교하여 임상적 유용성을 평가하고자 한다. 대상 및 방법 : 총 10명의 환자 CT 영상을 획득한 후 각각 단일에너지, 이중 에너지에 대한 체적변조회전치료 기법에 대한 치료 계획을 수립하였다. 종양 측 변화 요인을 분석하기 위하여 조형계수(CI)와 균질성 지수(HI), 최대 선량을 각각 계산했으며, 정상 조직에 대한 선량 분포를 비교하기 위하여 $V_{10}$$V_5$, 종양에 가장 근접한 첫 번째 ~ 네 번째 갈비뼈($1^{st}{\sim}4^{th}$ Rib), 척수(Spinal Cord), 식도(Esophagus)와 기관(Trachea)를 선정하였다. 또한 계획한 선량 분포가 실제 전달되는 정확성을 확인하기 위하여 2차원 이온전리함 배열을 이용하여 선량 측정을 시행하였다. 결 과 : 종양 측 인자의 경우 조형계수와 균질성 지수는 두 에너지를 사용했을 경우가 1에 가까운 값을 나타냈다. 최대 선량의 경우 앞쪽 흉벽은 약 2%, 등쪽 종양의 경우는 동등한 값을 나타냈다. 정상 조직의 경우 앞쪽 흉벽 종양은 인접한 갈비뼈에서 두 에너지를 동시에 사용한 경우 각각 4%, 5% 감소하였고, 기관지의 경우 11%, 17% 감소하였다. 폐의 선량 분포의 경우 $V_{10}$의 경우 1.5%, $V_5$의 경우 1%로 감소함을 나타냈다. 뒤쪽 흉벽의 경우 종양에 인접한 갈비뼈는 두 에너지를 이용한 경우에서 각각 6%, 1%, 4%, 12% 감소하였고, 폐의 선량 분포에서는 $V_{10}$ 3%, $V_5$ 3.1% 감소됨을 나타내었다. 선량 측정의 경우 모든 에너지에서 감마지표 3mm/3%의 결과에 부합하였다. 결 론 : 단일 에너지를 이용한 치료 계획 보다 두 에너지를 동시에 사용하는 경우가 표재성 종양에 대해 보다 유용하게 적용될 수 있을 것으로 사료된다.

  • PDF