• 제목/요약/키워드: 3-dimensional CT

검색결과 591건 처리시간 0.024초

Three-dimensional imaging modalities in endodontics

  • Mao, Teresa;Neelakantan, Prasanna
    • Imaging Science in Dentistry
    • /
    • 제44권3호
    • /
    • pp.177-183
    • /
    • 2014
  • Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of periradicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교 (Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull)

  • 강복희;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교 (Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures)

  • 정종명;김종환;홍인표;최치훈
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

기관협착증에서 3차원적 영상 진단의 의의 (The Significance of 3-Dimensional Imaging in Tracheal Stenosis)

  • 정동학;봉정표;이운우;노정래;성기준
    • 대한기관식도과학회지
    • /
    • 제1권1호
    • /
    • pp.82-93
    • /
    • 1995
  • Three-dimensional reconstruction of computed tomographic image(3D CT) is a well-established imaging modality which has been investigated in various clinical settings. It is commonly performed in case of congenital or developmental abnormalities, and traumatic fracture of skull and face that requires reconstruction of osseous structure. However reporting the 3D CT in laryngeal or tracheal stenosis is rare and its results are obscure. The authors performed 3D CT in six cases of tracheal stenosis and found diagnostic value of 3D CT. A Comparision of diagnostic information obtained from plain X-ray, 2D CT and 3D CT has performed in total six cases of tracheal stenosis. Surgical treatment of the tracheal stenosis was following in these cases : tracheal end to end anastomosis In 1 case, laryngotracheal end to end anastomosis in 2 cases. 3D CT information was compared with operative finding. In two of six cases, satisfactory information was not obtained from 3D CT in evaluating an exact stenosis of trachea. Future, it will be helped in evaluating of tracheal stenosis by 3D CT.

  • PDF

Multi-Detector Row CT를 이용한 중심부 기도 질환의 평가 (Multi-Detector Row CT of the Central Airway Disease)

  • 강은영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제55권3호
    • /
    • pp.239-249
    • /
    • 2003
  • Multi-detector row CT (MDCT) provides faster speed, longer coverage in conjunction with thin slices, improved spatial resolution, and ability to produce high quality muliplanar and three-dimensional (3D) images. MDCT has revolutionized the non-invasive evaluation of the central airways. Simultaneous display of axial, multiplanar, and 3D images raises precision and accuracy of the radiologic diagnosis of central airway disease. This article introduces central airway imaging with MDCT emphasizing on the emerging role of multiplanar and 3D reconstruction.

3차원 CT 영상을 이용한 두개악안면 분석을 위한 계측점의 제안 (A proposal of landmarks for craniofacial analysis using three-dimensional CT imaging)

  • 장혜숙;백형선
    • 대한치과교정학회지
    • /
    • 제32권5호
    • /
    • pp.313-325
    • /
    • 2002
  • 3차원 CT에서는 환자의 움직임에 의한 오차와 상의 확대나 왜곡을 감소시킨 실측치를 얻을 수 있으며 두개안면부의 입체적인 영상을 구성할 수 있고 원하는 조직이나 구조물의 관찰이 용이하다 디지털 영상 기술이 빠르게 발전하고 있고 치료의 범위가 더욱 넓어지면서 두개악안면 구조의 3차원적인 분석법의 개발은 시급한 과제가 되었다. 이에 본 연구에서는 Vworks 프로그램$^{TM}$ (Cybermed Inc., Seoul, Korea)과 건조두개골을 이용하여 3차원 CT 영상의 오차와 확대율을 평가하고Vmorph-proto프로그램 $^{TM}$ (Cybermed Inc., Seoul, Korea)을 이용하여 정상인과 비대칭 환자의 3차원 CT영상에서 지정이 용이하고 반복재현성이 높은 계측점을 설정하고자 하여 다음과 같은 결론을 얻었다 ; 1. 건조두개골의 실측치와 Vworks 프로그램을 이용하여 구성한 3차원 CT영상에서 의 계측치를 비교한 결과 평균오차가 0.99mm, 확대율이 1.04%로 나타났다. 2. 3차원 CT영상에서 경조직 계측점으로 Supraorbitale, Lateral orbital margin, Infraorbitale, Natron, ANS, A point, Zygomaticomaxilla, Upper incisor, Lower incisor, B point, Pogonion, Menton, PNS, Condylar inner margin, Condylar outer margin, Porion, Condylion, Gonionl, Gonion2, Gonion3, Sigmoid notch, Basion 등이 임상적으로 유용하다고 판단되었다. 3. 3차원 CT영상에서 연조직 계측점으로 Endocanthion, Exocanthion, Soft tissue Nasion, Pronasale, Alare lateralis, Upper nostril point, Lower nostril point, Subnasale, Upper lip point, Cheilion, Stomion, Lower lip center, Soft tissue B, Pogonion, Menton, Preaurale 등이 임상적으로 유용하다고 판단되었다. Vworks 프로그램으로 3차원 CT영상을 구성하고 계측하는 것이 임상적으로 유용하다고 판단되었다. 또한 위에서 제안된 연조직 및 경조직 계측점들은 3차원 CT영상에서 반복 재현성이 높고 지정이 용이하며 해부학적 특징을 나타내주는 점들로 두개악안면 구조의 3차원적인 진단과 술전, 술후의 예측과 비교에 유용하게 사용될 것으로 사료되는 바이다.

CT와 MRI 영상을 이용한 간담도계 간접볼륨렌더링 (Indirect Volume Rendering of Hepatobiliary System from CT and MRI Images)

  • 진계환;이태수
    • 한국방사선학회논문지
    • /
    • 제1권2호
    • /
    • pp.23-30
    • /
    • 2007
  • 본 논문에서는 CT(Computed Tomography)와 MRI(Magnetic Resonance Imaging)을 이용하여 획득한 2차원의 복부영상을 영역분할, 문턱치법 등의 전처리과정을 거쳐 3차원영상을 생성하는 방법을 제시함으로써 가상내시경(Virtual Endoscopy)에 응용하고자 한다. 3차원영상 가시화 방법으로는 개인용 컴퓨터에서 이용되는 범용의 그래픽가속기를 이용하여 빠른 속도로 렌더링을 할 수 있는 장점을 가지는 표면볼륨기법을 이용하였다. 여기에 이용한 알고리즘은 계산량이적은 Marching Cubes 이다. 그리고 워크스테션이나 전용의 프로그램이 없더라도 웹 브라우저 상에서 실행되는 가상현실모델링언어(VRML, Virtual Reality Modeling Language)양식의 3차원 영상을 생성하는 방법을 제시한다. CT의 3차원 영상 파일의 노드 수와 삼각형 수 및 크기는 각각 85,367, 174,150, 10,124이었고, MRI의 3차원 영상 파일의 노드 수와 삼각형 수 및 크기는 각각 34,029, 67,824, 3,804이었다.

  • PDF

3-D CT Imaging of Pathological Bone Changes in a Rat Model of Adjuvant-Induced Arthritis

  • Shim, Kyung-Mi;Kim, Se-Eun;Kang, Seong-Soo
    • 한국방사선학회논문지
    • /
    • 제2권4호
    • /
    • pp.41-46
    • /
    • 2008
  • CT는 단층촬영을 이용한 의학적인 영상 진단 기법이다. CT는 3차원적인 방사선학적 영상 기법으로 염증의 평가에는 적합하지 않으나, 석회화된 조직을 직접적인 3차원 영상으로 보여주므로 뼈 손상의 평가에는 유용하다. 본 연구는 실험적으로 유도된 랫드의 보조관절염에서 관절의 병리학적 변화와 뼈 파괴의 정량적 분석을 3차원 CT 영상을 통하여 평가하고자 실시되었다. 그 결과 랫드의 보조관절염에서 병변의 파괴성 진행이 3차원 CT 영상을 통해 정량화될 수 있었고, 따라서 관절염 질환의 상태 및 실험적인 치료 약제의 효능 평가에 3차원 CT 영상 기법이 효과적일 것으로 생각된다.

  • PDF

CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구 (Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model)

  • 엄기두;이병도
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석 (Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure)

  • 백종수;송재철;이희경
    • Journal of Yeungnam Medical Science
    • /
    • 제18권1호
    • /
    • pp.123-137
    • /
    • 2001
  • 6개의 건조두개골상의 중요한 방사선학적 계측점에 금속구를 위치시킨 후 3-D CT와 정모 및 측모 두부 방사선사진을 촬영하고 이를 바탕으로 만든 각각의 3차원 영상과 3차원 두부 방사선사진상의 각 계측점들이 3차원적으로 어느 정도의 정확성을 가지고 재현되는지를 알아보았다. 그리고 두 방법에 있어서의 계측점간의 거리계측을 실계측과 비교분석 함으로써 악안면부에서의 재현성과 정확성을 알아본 결과 다음과 같은 결과를 얻었다. 3-D CT와 3차원 두부 방사선사진상의 계측점들은 반복 계측시 각각 X축 방향으로 0.23 mm와 0.30 mm, Y축 방향으로 0.27 mm와 0.25 mm, 그리고 Z축 방향으로 0.27 mm와 0.31 mm의 표준편차를 보였다. 두 방법에서 모든 계측점이 0.5 mm 이하의 표준편차를 보였으며, 대부분의 계측점이 1 mm 이하의 범위를 보인 바, 두 방법 모두 통일한 건조두개골상의 계측점의 3차원적 위치 편차가 거의 없었다. 모든 계측항목에서 실측치와 3-D CT간의 차이는 평균 0.33 mm였으며, 실측치와 3차원 두부 방사선사진간의 차이는 평균 1.13 mm로 상대적으로 높게 나타났다. 가장 큰 차이를 보인 항목은 RGo과 LGo간으로 2.03 mm의 차이를 보였다. 그러나 두 방법 모두 모든 항목에서 실측치와 통계적으로 매우 높은 상관관계를 보였다(${\gamma}=0.976{\sim}1.000$, p<0.01).

  • PDF