• Title/Summary/Keyword: 3-arm type

Search Result 259, Processing Time 0.025 seconds

The Effect of Arm Swing on Gait in Healthy Adults (팔 흔들기가 정상인의 보행에 미치는 영향)

  • Jung, Hwa-Su;Choi, Su-Hee;Park, Sun-Ja;Oh, Hye-Jin;Cho, Hwa-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.451-459
    • /
    • 2014
  • This study was to performed to get the reference data of the kinetic parameters for normal subjects according to the arm swing type. Forty-five normal subjects($22.62{\pm}2.69years$) pariticpated in this study and preformed 4 sequence according to the arm swing type as follows; first procedure-normal arm swing, second procedure-one arm swing, thrid procedure-no arm swing, fourth procedure-fitness arm swing. There were significant differences according to the arm swing type in the kinetic parameters such as walking speed, hip power, ground reaction force of vertical in terminal stance phase(p<.05). These finding can be utilized (a) as a reference for kinetic data of gait analysis in normal subjects, and (b) as an aide in evaluating and treating patients who have problems relating to gait.

3-Dimensional Printing for Mesh Types of Short Arm Cast by Using Computed Tomography (전산화단층영상을 이용한 그물형 손목 부목의 3D 프린팅)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.308-315
    • /
    • 2015
  • The purpose of this study, using 3D printer, was tried to fabricate the short arm cast of mesh types that can be hygienic and adequate ventilation with a good radiography. We used the multi channel computed tomography (MDCT) with three dimension printer device of the fused deposition modeling (FDM) techniques. The material is used a degradable plastic (poly lactic acid, PLA). Three-dimensional images of the short arm were obtained in the MDCT and then make the three-dimensional volume rendering. Three dimension volume rendering of the short arm is implemented as a tomography obtained in MDCT. Virtual mesh type cast model was output as three-dimensional images is designed based on the three-dimensional images of the short arm. As a results, the cast output by 3D printers were able to obtain excellent radiograph images than the conventional cast, and then it can decreased itching with unsanitary, and can break down easily to the cast. In conclusion, the proposed virtual mesh type cast output by 3D printers could be used as a basis for future three-dimensional printing cast productions and offered help to patients in the real life.

A Study on the Length Variation of the Upper Arm Surface for Early Elementary Schoolgirls (학령 전기 여아의 상지 체표길이 변화 연구)

  • Pae, Eun-Ah;Jang, Jeong-Ah;Kwon, Young-Suk
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.7 s.107
    • /
    • pp.33-45
    • /
    • 2006
  • This study was to provide the fundamental data for a scientific and rational clothing construction by investigating the length variation of the upper arm surface, using the method of surgical tape, and to understand the expansion and contraction of parts of body for the making of clothing adaptable to movement. The subjects were li early elementary schoolgirls in Busan area classified with three somatotypes, and arm-movements consisted of 6 types. The statistical analyses used in this study were mean, standard deviation and the ANOVA and LSD procedure. The results of the analysis of the length of the upper arm surface are as follows: By arm-movements, in the items of horizontal, upper arm length changed more in the front than in the back, and in the items of vertical, represented the opposite of horizontal items. In the items of upper arm, the anterior-posterior axilla length and under arm length were influenced by arm-movements, and the under length of the upper arm represented the maximum rate increase of 74.59%(3.20cm)$\sim$138.72%(4.28cm). In the somatotypes of early elementary schoolgirls, type II was more influenced by arm-movements, and for the making of clothing adaptable to movement, type III needed to reflect more surplus length(2cm) than the other types.

Circadian Fluctuation of Body Temperature in Different Thermal Conditions of the Distal Extremities by Clothing Type Worn during the Afternoon

  • Park, Shin-Jung
    • International Journal of Human Ecology
    • /
    • v.10 no.1
    • /
    • pp.35-45
    • /
    • 2009
  • Six healthy female volunteers twice undertook an experiment with different types of clothing leaving the arms and legs covered or uncovered at $24{\pm}0.5^{\circ}C$ and $50{\pm}5%$ RH to study how different thermal stimulation to the distal extremities during the afternoon could modulate circadian parameters of body temperature rhythm. One type of clothing consisted of long-sleeved shirts and full-length trousers (Type I, 989 g, 0.991 clo); the other type consisted of half-sleeved shirts and knee-length trousers (Type II, 750 g, 0.747 clo). Subjects wore Type I or Type II clothing during the afternoon (14:00 h - 19:00 h), and Type I clothing during the evening (19:00 h - 22:30 h) and the night sleep (22:30 h - 06:00 h). Rectal temperature and skin temperatures at the arm and leg were measured continuously. Results were as follows: 1) The circadian amplitude of rectal temperature tended to be greater, and the acrophase was significantly earlier when wearing Type II rather than Type I clothing. 2) The circadian nadirs of skin temperatures of the arm and leg were significantly lower and the amplitudes were significantly greater with Type II clothing. In addition, the acrophase and bathyphase of the circadian rhythm of arm skin temperature were significantly earlier with Type II than Type I clothing. 3) The amplitude of rectal temperature was related closely with that of arm and leg skin temperature. These results suggest that a slightly cool thermal stress during the afternoon to the arms and legs exerted by wearing half-sleeved shirts and knee-length trousers induces a greater amplitude and a phase advance of the overt circadian rhythm of body temperature.

The Effect of Foot Pressure on the Irradiation of a PNF Upper Arm Pattern on Standing Posture with an Elastic Band: A Randomized Control Trial (바로 선 자세에서 탄력밴드를 이용한 PNF 팔 패턴의 방산효과가 발 압력에 미치는 영향)

  • Yang, Jae-Man;Lee, Jung-Hoon;Kang, Seung-Won
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.425-432
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the relationship between foot pressure and upper arm PNF exercise conducted with elastic bands while standing. Methods: Eighteen asymptomatic patients consented to participate in the study. Foot pressure was measured in the standing position using the Gaitview system for proprioceptive neuromuscular facilitation stretching (PNF) using a right upper arm pattern. Resistance strength was varied based on the type of elastic band used (red=medium, green=heavy, and blue=extra heavy). Statistical significance of the results was evaluated using a repeated one-way ANOVA, and the Bonferroni method was used for the ad hoc test (SPSS ver. 18. for Windows). Results: A significant difference was observed in fore-foot, rear-foot, and everage pressure after upper arm PNF exercise. However, there was no significant difference according to the type of elastic band. Conclusion: Based on the results of this study, an upper arm PNF exercise with and without resistance may affect foot pressure in the standing position.

Study on Fabrication of a Large Concave Mirror Surface Using a Swing-Arm Type Profilometer (스윙암 방식의 형상 측정기를 이용한 대형 반사경의 정밀가공에 관한 연구)

  • Lee, Ki-Am;Kim, Ock-Hyun;Lee, Eung-Suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.3
    • /
    • pp.41-46
    • /
    • 2008
  • Generally optical components are fabricated by grinding, lapping and polishing processes. Those processes take long time to obtain optical high surface quality. In the case of large optical components, the on-machine measurement is strongly recommended because the workpiece is fragile and difficult to set up for fabricating and measuring. This paper is concerned about a swing-arm mechanism which can be used for on-machine measurement of a surface profile with a sensing probe end-effect, and also for grinding or lapping the surface with a corresponding tool. The measuring accuracy and uncertainty using a swing arm type profilometer have been studied. The experimental results show that this method is useful specially in lapping process with the accuracy of $5{\mu}m$. Those inspection data are provided for correcting the residual figuring error in next processes.

  • PDF

Statistical Assessment of Biosimilarity based on the Relative Distance between Follow-on Biologics in the (k + 1)-Arm Parallel Design

  • Kang, Seung-Ho;Shin, Wooyoung
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.6
    • /
    • pp.605-613
    • /
    • 2015
  • A three-arm parallel design has been proposed to assess the biosimilarity between a biological product and a reference product using relative distance (Kang and Chow, 2013). The three-arm parallel design consists of two arms for the reference product and one arm for the biosimilar product. This paper extended the three-arm parallel design to a (k + 1)-arm parallel design composed of k (${\geq}3$) arms for the reference product and one arm for the biosimilar product. A new relative distance was defined based on Euclidean distance; consequently, a corresponding test procedure was developed based on asymptotic distribution. Type I error rates and powers were investigated both theoretically and empirically.

Evaluation of control feel in opening and closing the doors of a virtual refrigerator in the CAVE system with an Arm-Master (CAVE 공간에서 Arm-Master를 이용한 가상냉장고 도어 개폐의 조작감 평가)

  • 박재희;이인석;김진욱;고희동
    • Science of Emotion and Sensibility
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This study aims to validate the effectiveness of CAVE system with an Arm-Master in the evaluation of virtual prototypes. A virtual kitchen with a refrigerator was presented in the CAVE system. Subjects put in and pull out virtual objects by using the Arm-Master. Twelve subjects, six males and six females, participated in the six experimental conditions : three types of refrigerator door grips and two reaction forces. After each trial, subjects evaluated a door grip of the virtual refrigerator in terms of easiness of operation, similarity in force, presence etc. The results show the mean values of vortical-type door grips are greater than the horizontal pocket-type door grip. Also the subjects preferred 5N in the reaction force of the Arm-Master rather than 15 N when they open and close virtual door. Unexpectedly, female subjects significantly marked low scores in the evaluation terms compared ruth mali subjects. It explains the Arm-Master should be modified much more if it works effectively in design evaluation.

  • PDF

Gait analysis on the condition of arm swing in healthy young adults

  • Koo, Hyun-Min;Lee, Su-Young
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2016
  • Objective: The arm swing is associated with gait ability in healthy young adults. The purpose of this study was to examine the effects of arm swing during gait in healthy young adults. Design: Cross-sectional study. Methods: Forty-five subjects without any orthopedic or neurological injuries participated in this study. All subjects performed all three conditions according to the arm swing type as follows: first procedure (condition 1), walking as usual without arm swing constraint; second procedure (condition 2), constraint of dominant arm swing walking as usual; third procedure (condition 3), constraint of both arm swing walking as usual. Gait parameters such as gait velocity, stride length, cadence, step time, single limb support, and double limb support were measured in all arm swing conditions performed randomly, with the mean value obtained from three measurements. A rest period of 5 minutes was given to prevent repetition of each condition and learning effect. All data was analyzed using repeated measures ANOVA to notice the changes between arm swing conditions. Results: Within walking conditions, significant difference of gait velocity, stride length, cadence, and double limb support was noticed (p<0.05), except step time and single limb support. Gait velocity and stride length were significant reduced, and in cadence and double limb support were increased (p<0.05). Condition 3 had the most significant decrease of gait ability compared with condition 1 (p<0.05). Conclusions: These finding suggested that constraint arm swing conditions reduced gait ability in healthy young adults. Also, these findings can be utilized as a reference to future studies that not only pelvic, knee and ankle, but also upper limb affect to gait ability.

Stress Analysis of LOWER ARM for Change of Section Shape(I) (단면 형상의 변화에 따른 LOWER ARM의 응력 해석(I))

  • 박영철;윤두표;한근조;배명호;진두병;이범재
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.99-107
    • /
    • 1998
  • Stress distribution analysis was implemented by using finite element method for the lower arm connecting Independent front suspension. Results were obtained for the 8 load conditions and for the 3 types of section (I, H and H+I). On the basis of it, the shape and dimensions of lower arm were optimized. Finally it was pointed out that the H type has an most satisfied strength, among 3 section types and highest safety factor and yield strength in each case of load condition.

  • PDF