• 제목/요약/키워드: 3-Dimensional D.P.

검색결과 570건 처리시간 0.029초

Three-dimensional analysis of tooth movement in Class II malocclusion treatment using arch wire with continuous tip-back bends and intermaxillary elastics

  • Lee, Ji-Yea;Choi, Sung-Kwon;Kwon, Tae-Hoon;Kang, Kyung-Hwa;Kim, Sang-Cheol
    • 대한치과교정학회지
    • /
    • 제49권6호
    • /
    • pp.349-359
    • /
    • 2019
  • Objective: The aim of this study was to analyze three-dimensional (3D) changes in maxillary dentition in Class II malocclusion treatment using arch wire with continuous tip-back bends or compensating curve, together with intermaxillary elastics by superimposing 3D virtual models. Methods: The subjects were 20 patients (2 men and 18 women; mean age 20 years 7 months ${\pm}$ 3 years 9 months) with Class II malocclusion treated using $0.016{\times}0.022-inch$ multiloop edgewise arch wire with continuous tip-back bends or titanium molybdenum alloy ideal arch wire with compensating curve, together with intermaxillary elastics. Linear and angular measurements were performed to investigate maxillary teeth displacement by superimposing pre- and post-treatment 3D virtual models using Rapidform 2006 and analyzing the results using paired t-tests. Results: There were posterior displacement of maxillary teeth (p < 0.01) with distal crown tipping of canine, second premolar and first molar (p < 0.05), expansion of maxillary arch (p < 0.05) with buccoversion of second premolar and first molar (p < 0.01), and distal-in rotation of first molar (p < 0.01). Reduced angular difference between anterior and posterior occlusal planes (p < 0.001), with extrusion of anterior teeth (p < 0.05) and intrusion of second premolar and first molar (p < 0.001) was observed. Conclusions: Class II treatment using an arch wire with continuous tip-back bends or a compensating curve, together with intermaxillary elastics, could retract and expand maxillary dentition, and reduce occlusal curvature. These results will help clinicians in understanding the mechanism of this Class II treatment.

광경화성 3D 프린팅 레진의 출력각도에 따른 굽힘 특성과 신뢰성 평가 (Evaluation of flexural properties and reliability with photo-curing 3D printing resin according to the printing orientations)

  • 임용운;송두빈;황성식;김사학;한만소
    • 대한치과기공학회지
    • /
    • 제43권1호
    • /
    • pp.13-18
    • /
    • 2021
  • Purpose: This study aimed to compare the flexural properties and perform the Weibull analysis of photo-curing three-dimensional (3D) printing resin. Methods: Photo-curing temporary resin (3D polymer) was used as a printing resin. Specimens (65 × 10 × 3.3 ㎣) were prepared following the ISO 20975-1 guidelines and according to the different printing orientations using a digital light processing 3D printer (D2 120; Dentium). The flexural strength (FS), flexural modulus, and work of fracture (WOF) were measured using a universal testing machine (Instron 3344; Instron) at a crosshead speed of 5 mm/min. Results: In this study, the 0° orientation exhibited higher FS and WOF than the 45° orientation. Significant differences were found among the printing orientations (p<0.05). Specimens printed at the 0° orientation were the most accurate. In the Weibull analysis, 0° showed the greatest Weibull modulus (m), which represents a higher reliability. Conclusion: 3D printing should be selected and used by considering flexural properties, size accuracy, and reliability.

흰쥐 말초 혈액 림프구의 분자량 44 kD 단백의 인산화 (Phosphorylation of 44-kilodalton Proteins in Peripheral T-lymphocyte of Rat)

  • 안영수;주일로;오도연;임승욱;박경선
    • 대한약리학회지
    • /
    • 제27권2호
    • /
    • pp.135-144
    • /
    • 1991
  • 흰쥐 말초혈액에서 얻은 T 림프구를 아드레날린성 ${\beta}-$수용체 효현제 및 concanavalin A(Con-A)로 자극해 다음과 같은 결과를 얻었다. 자극이 없는 상태에서의 주 인산화 단백은 분자량 44kD, 등전점 6.8의 단백이었으며 효현제로 자극시키면 분자량 44kD, 등전점 6.3의 단백이 새로이 인산화되어 나타났다. 이 분자량 44kD, 등전점 6.3의 단백은 forskolin에 의해 역시 인산화되며 A-kinase 억제제인 H-8을 전처치하면 인산화의 억제가 나타났다. 또한 Con-A로 자극시키면 44 kD/pI 6.3 단백의 인산화가 증가되었으며 이 인산화의 증가는 CaM kinase 억제제인 W-7 전처치에 의해 억제되었다. H-7은 분자량 44 kD, 등전점 6.8 단백의 인산화를 감소 시켰다. 이상의 결과로 분자량 44 kD 등전점 6.3의 단백은 A-kinase와 CaM kinase 모두에 의해 인산화 되는 기질단백으로서 tryptic peptide map상에서 44 kD/pI 6.8 단백과 44 kD/pI 6.3 단백은 서로 다른 단백임을 알 수 있었다.

  • PDF

3 차원 입방형 표면조도가 난류경계층에 미치는 영향 (Turbulent Statistics of the Turbulent Boundary Layer over a Cube-Roughened Wall)

  • 이재화;성형진
    • 대한기계학회논문집B
    • /
    • 제34권10호
    • /
    • pp.917-923
    • /
    • 2010
  • 3 차원 표면조도의 영향을 조사하기 위하여 규칙적으로 배열된 3 차원의 입방형 표면조도를 갖는 난류경계층을 직접수치모사하였다. 표면조도는 주 유동방향과 횡 방향으로 각각 8k 과 2k 의 주기를 갖도록 배열되었으며 표면조도의 크기 (k)는 입구 운동량 두께(${\theta}_{in}$)의 1.5 배이다. 주 유동 방향을 따라 공간 발달하는 3 차원 표면조도 위의 난류특성을 2 차원의 막대형표면조도에서의 결과와 비교하였다. 2 차원 표면조도와 마찬가지로 3 차원 표면조도의 경우에도 조도저층 뿐만 아니라 바깥영역에서 표면조도의 영향이 존재하였으며 이러한 결과는 주 유동 방향의 표면조도의 주기와 사각형의 면에 의한 막음현상이 2 차원의 표면조도와 마찬가지로 크게 나타나기 때문인 것으로 판단된다.

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구 (DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING)

  • 최훈달;권긍록;김형섭;최대균
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

나노 실리카분말의 충진효과를 이용한 극미세 3차원 세라믹 구조물 정밀화 (Improvement of precision of three-dimensional ceramic microstructures employing silica nanoparticle-mixed precursor)

  • 임태우;박상후;양동열;;김동표
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.157-158
    • /
    • 2006
  • A novel nanofabrication process has been developed using two-photon crosslinking (TPC) for the fabrication of three-dimensional (3D) SiCN ceramic microstructures applicable to high functional 3D devices, which can be used in harsh working environments requiring a high temperature, a resistance to chemical corrosion, as well as tribological properties. After sequential processes: TPC and pyrolysis, 3D ceramic microstructures are obtained. However, large shrinkage due to low-ceramic yield during the pyrolysis is a serious problem to be solved in the precise fabrication of 3D ceramic microstructures. In this work, silica nanoparticles were employed as a filler to reduce the amount of shrinkage. In particular, the ceramic microstructures containing 40 wt% silica nanoparticles exhibited relatively isotropic shrinkage owing to its sliding free from the substrate during pyrolysis.

  • PDF

Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

  • Pittayapat, Pisha;Jacobs, Reinhilde;Odri, Guillaume A.;Vasconcelos, Karla De Faria;Willems, Guy;Olszewski, Raphael
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.15-22
    • /
    • 2015
  • Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

광중합 방식의 적층 가공으로 제작된 전치과 구치 단일 크라운의 적합도 평가 (Evaluation of fit of anterior and posterior single crowns manufactured by light-curing additive manufacturing)

  • 배은정;이완선
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.74-80
    • /
    • 2023
  • Purpose: This study aimed to evaluate the fit of the anterior and posterior teeth printed using two light-curing three-dimensional (3D) printers. Methods: Anterior and posterior single crowns were designed using dental software and were printed using 2 types of 3D printers, liquid crystal display (LCD) and digital light processing (DLP) (n=40). After the printed crown was scanned again from inside and outside, the prepared teeth were evaluated using a 3D program. To compare the root mean square (RMS) results among groups (α=0.05), the one-way analysis of variance and Tukey's test were used. Results: No statistically significant difference was found between the mean RMS values of the anterior and posterior teeth (p>0.05). However, as a result of comparing the internal, external, and tooth shapes, the DLP group showed significantly low errors in the inner and outer surfaces than LCD group (p<0.05). Conclusion: In terms of clinical acceptance standard of 100 ㎛, the fit of the anterior and posterior teeth fabricated using LCD and DLP was clinically acceptable.

Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation

  • Myagmar, Gerelmaa;Lee, Jae-Hyun;Ahn, Jin-Soo;Yeo, In-Sung Luke;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.144-151
    • /
    • 2021
  • PURPOSE. The purpose of this in vitro study was to investigate the wear resistance and surface roughness of three interim resin materials, which were subjected to chewing simulation. MATERIALS AND METHODS. Three interim resin materials were evaluated: (1) three-dimensional (3D) printed (digital light processing type), (2) computer-aided design and computer-aided manufacturing (CAD/CAM) milled, and (3) conventional polymethyl methacrylate interim resin materials. A total of 48 substrate specimens were prepared. The specimens were divided into two subgroups and subjected to 30,000 or 60,000 cycles of chewing simulation (n = 8). The wear volume loss and surface roughness of the materials were compared. Statistical analysis was performed using one-way analysis of variance and Tukey's post-hoc test (α=.05). RESULTS. The mean ± standard deviation values of wear volume loss (in mm3) against the metal abrader after 60,000 cycles were 0.10 ± 0.01 for the 3D printed resin, 0.21 ± 0.02 for the milled resin, and 0.44 ± 0.01 for the conventional resin. Statistically significant differences among volume losses were found in the order of 3D printed, milled, and conventional interim materials (P<.001). After 60,000 cycles of simulated chewing, the mean surface roughness (Ra; ㎛) values for 3D printed, milled, and conventional materials were 0.59 ± 0.06, 1.27 ± 0.49, and 1.64 ± 0.44, respectively. A significant difference was found in the Ra value between 3D printed and conventional materials (P=.01). CONCLUSION. The interim restorative materials for additive and subtractive manufacturing digital technologies exhibited less wear volume loss than the conventional interim resin. The 3D printed interim restorative material showed a smoother surface than the conventional interim material after simulated chewing.