• 제목/요약/키워드: 3-Dimensional D.P.

검색결과 570건 처리시간 0.029초

원심식(遠心式) 분무건조장치(噴霧乾燥裝置)의 작동조건(作動條件)에 따른 분무입자(噴霧粒子)의 입도예측(粒度豫測) 모델 (A Prediction Model of Droplet Size of Rotary Spray Dryer at Various Operating Conditions)

  • 노상하;김기복;이종환;이상조
    • Journal of Biosystems Engineering
    • /
    • 제17권3호
    • /
    • pp.229-236
    • /
    • 1992
  • In an effort to localize the spray-dryer which is markedly used for drying food materials, a experiment was carried out with a wheel type atomizer locally designed and manufactured to evaluate the effect of rotational speed, feed rate and physical properties of liquid food material on the droplet size, and to develop a model to predict the droplet size sprayed at various operational conditions. The result are summarized as follows. 1. The frequency of droplet size sprayed from the atomizer at every treatment were similar to normal distributions. 2. Under the test conditions adopted in this study, that is, rotational speed of the atomizer ranging from 15,000 to 20,000 rpm (55.0 m/sec - 73.3 m/sec), feed rate from 14 to 37 kg/hr and viscosity of the material from 1.14 to 350 cP, the mean volume-surface dia. of droplets was decreased as increase in rotational speed and was not affected significantly by the feed rate and viscosity. 3. Through the dimensional analysis, a prediction model was developed as follows : $$\frac{Dvs}{r}=K[\frac{Q}{{\mu}r}]^a[\frac{rN^2}{g}]^b[\frac{{\rho}^2r^3g}{{\mu}^2}]^c[\frac{L}{r}]^d$$ and it was proved that the above model was better in degree of fitness than other models reported. 4. A prediction equation for the droplet size sprayed from the atomizer under the test was expressed as follows : $$\frac{Dvs}{r}=0.0215[\frac{Q}{{\mu}r}]^{0.06}[\frac{rN^2}{g}]^{0.3314}[\frac{{\mu}^2}{{\rho}^2r^3g}]^{0.0158}$$.

  • PDF

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

풍력 발전 터빈 후류의 동적 분석 (Dynamic analysis of wind turbine wake)

  • 엄용한;김윤구;박성군
    • 한국가시화정보학회지
    • /
    • 제18권2호
    • /
    • pp.59-65
    • /
    • 2020
  • Vertical axis wind energy systems including 3 and 4 blades are numerically investigated in a two-dimensional (2D) computational domain. The power coefficient (Cp) is adopted to measure the efficiency of the system and the effect of the rotating velocity on the power coefficient is analyzed for the two different systems. The rotating velocity varies from 30 rad/s to 90 rad/s, which corresponds to the tip speed ratio (T.S.R) of 0.5 to 1.5. The torque exerted on the blades is mainly determined by the aerodynamic force in the x-direction and maximized when the blade is positioned at around θ = 186°. The efficiency of the 4-blade system is higher than that of the 3-blade system within the tip speed ratio range between 0.5 and 0.67, besides where the 3-blade system shows a better performance. For the 3-blade system, the maximum efficiency is reached to 0.082 at the tip speed ratio of 1.083. The maximum efficiency of the 4-blade system is 0.071 at T.S.R. = 0.92. The velocity fields in the x-direction, pressure fields, and the vorticity magnitude are analyzed in detail for the optimal cases of the 3- and 4-blades systems, respectively.

Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

  • Silva, Nathalia Cristine da;Barriviera, Mauricio;Junqueira, Jose Luiz Cintra;Panzarella, Francine Kuhl;Raitz, Ricardo
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.11-15
    • /
    • 2017
  • Purpose: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT(Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. Materials and Methods: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal(distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. Results: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. Conclusion: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

3차원 인체 측정기를 이용한 체표변화 분석 (Upper Body Surface Change Analysis using 3-D Body Scanner)

  • 이정란
    • 한국의류학회지
    • /
    • 제29권12호
    • /
    • pp.1595-1607
    • /
    • 2005
  • 3차원 스캐너를 통한 인체 측정치는 다양한 분야에서 사용되고 있다. 본 연구는 이러한 3차원 측정치의 정확성과 신뢰도를 조사하기 위한 것이다. 이를 위해 TECMATH사의 VITUS 전신 스캐너로 인체를 측정, ScanWorX Body Measure 소프트웨어를 이용하여 항목을 측정 한 값과 직접 인체측정 에 의해 얻어진 값을 비교하였다. 피험자는 평균 체형의 미국 여대생 25명이며 기준 자세와 일상생활에 많이 쓰이는 $135^{\circ}$ 양팔들기, 어깨 구부리기, 어깨 들어올리기의 3가지 동적 자세를 실험 동작으로 하여 체표의 길이 및 둘레의 변화를 측정하였다. 기준 자세와 135"양팔 들기에 대한 측정치 비교에서 두 가지 측정법에 의한 항목들의 차이는 $-2\~20mm$였으나 두 동작 모두에서 목둘레만이 유의한 차이가 있는 것으로 나타났다. 또한 길이항목보다 둘레항목에서 좀 더 큰 차이를 보였다. 실험 동작에 의해 상반신 18개의 측정항목들은 유의한 체표변화를 나타내었으며 특히 어깨길이, 겨드랑앞벽사이길이, 겨드랑뒤벽사이길이 그리고 견봉사이길이에서 뚜렷한 변화가 나타났다. 그러나 두 측정 법에 따른 체표변화 차이는 없었다. 어깨 구부리기와 어깨 들어올리기 동작시에는 스캔 측정을 3회 반복함으로써 3차원 측정치의 신뢰도를 조사하였는데 모든 항목에서 3회 반복된 측정치가 통계적으로 동일한 것으로 나타났다. 또한 ScanWorX소프트웨어의 가상적 도구인 Body Measure와 자동 프로그램인 ScanWorX Tailor의 측정치를 비교한 결과 자동 측정치가 더 큰 값을 보였고 사용한 프로그램에 따른 유의한 차이를 나타내는 항목들이 나타났다. 이상의 결과로 3차원 인체 측정기를 사용함으로써 짧은 시간에 동작을 촬영하고 이에 대한 측정치를 얻을 수 있어 편리함과 신뢰도에 있어서 장점을 가짐을 확인할 수 있었다. 그러나 좀 더 다양한 분석과 정확한 결과를 얻기 위해서는 의복 분야에 유용한 자동 프로그램의 개발과 3차원 인체 측정기간의 호환성의 문제들이 요구된다고 할 수 있다.

Effect of Grape Seed Proanthocyanidins on Tumor Vasculogenic Mimicry in Human Triple-negative Breast Cancer Cells

  • Luan, Yun-Yan;Liu, Zi-Min;Zhong, Jin-Yi;Yao, Ru-Yong;Yu, Hong-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권2호
    • /
    • pp.531-535
    • /
    • 2015
  • Vasculogenic mimicry (VM) refers to the unique ability of highly aggressive tumor cells to mimic the pattern of embryonic vasculogenesis, which was associated with invasion and metastasis. The grape seed proanthocyanidins (GSPs) had attracted much attention as a potential bioactive anti-carcinogenic agent. However, GSPs regulation of VM and its possible mechanisms in a triple-negative breast cancer cells (TNBCs) remain not clear. Therefore, we examined the effect of GSPs on VM information in HCC1937 cell model. In this study, we identified the VM structure via the three-dimensional (3D) matrix in vitro. Cell viability was measured using the CCK8 assay. The effects of GSPs on human triple-negative breast cancer cells (TNBCs) HCC1937 in terms of related proteins of VM information were determined using western blot analysis. In vitro, the tubular networks were found in highly invasive HCC1937 cells but not in the non-invasive MCF-7 cells when plated on matrigel. The number of vascular channels was significantly reduced when cells were exposed in GSPs ($100{\mu}g$/ml) and GSPs ($200{\mu}g/mL$) groups (all p<0.001). Furthermore, we found that treatment with GSPs promoted transition of the mesenchymal state to the epithelial state in HCC1937 cells as well as reducing the expression of Twist1 protein, a master EMT regulator.GSPs has the ability to inhibit VM information by the suppression of Twist1 protein that could be related to the reversal of epithelial-to-mesenchymal (EMT) process. It is firstly concluded that GSPs may be an p otential anti-VM botanical agent for human TNBCs.

Positional changes in the mandibular proximal segment after intraoral vertical ramus osteotomy: Surgery-first approach versus conventional approach

  • Jung, Seoyeon;Choi, Yunjin;Park, Jung-Hyun;Jung, Young-Soo;Baik, Hyoung-Seon
    • 대한치과교정학회지
    • /
    • 제50권5호
    • /
    • pp.324-335
    • /
    • 2020
  • Objective: To compare postoperative positional changes in the mandibular proximal segment between the conventional orthognathic surgery (CS) and the surgery-first approach (SF) using intraoral vertical ramus osteotomy (IVRO) in patients with Class III malocclusion. Methods: Thirty-eight patients with skeletal Class III malocclusion who underwent bimaxillary surgery were divided into two groups according to the use of preoperative orthodontic treatment: CS group (n = 18) and SF group (n = 20). Skeletal changes in both groups were measured using computed tomography before (T0), 2 days after (T1), and 1 year after (T2) the surgery. Three-dimensional (3D) angular changes in the mandibular proximal segment, condylar position, and maxillomandibular landmarks were assessed. Results: The mean amounts of mandibular setback and maxillary posterior impaction were similar in both groups. At T2, the posterior portion of the mandible moved upward in both groups. In the SF group, the anterior portion of the mandible moved upward by a mean distance of 0.9 ± 1.0 mm, which was statistically significant (p < 0.001). There were significant between-group differences in occlusal changes (p < 0.001) as well as in overjet and overbite. However, there were no significant between-group differences in proximal segment variables. Conclusions: Despite postoperative occlusal changes, positional changes in the mandibular proximal segment and the position of the condyles were similar between CS and SF, which suggested that SF using IVRO achieved satisfactory postoperative stability. If active physiotherapy is conducted, the proximal segment can be adapted in the physiological position regardless of the occlusal changes.

진행된 간세포암에서의 간문맥 혈전증에 대한 방사선치료 효과 (The Role of Radiotherapy in the Treatment of Portal Vein Thrombosis from Advanced Hepatocellular Carcinoma)

  • 김정훈;최은경;안승도;이상욱;신성수;최원식;임영석;김강모;서동진;정영화;이영상;원형진;김종훈
    • Radiation Oncology Journal
    • /
    • 제25권3호
    • /
    • pp.170-176
    • /
    • 2007
  • 목적: 치료방법이 정립되지 않은 진행된 간세포암에서의 간문맥 혈전증에 대한 방사선치료의 효과와 간독성을 측정함으로써 향후 방사선치료의 효용성에 대하여 알아보고자 한다. 대상 및 방법: 2000년 5월부터 2005년 12월까지 서울아산병원에서 원발성 간세포암으로 진단받은 환자 중 간문맥 혈전증이 동반된 70명의 환자를 대상으로 후향적 분석을 하였다. 대상 환자들의 나이는 $24{\sim}74$세(중앙값 51세)였으며, 대부분이 Child-Pugh's class A, B였고 Eastern Cooperative Oncology Group (ECOG) 2 이하였다. 방사선치료는 3차원입체조형치료를 시행하였으며, 1회 선량은 $2{\sim}4$ Gy로 총방사선량은 $40{\sim}60$ Gy (중앙값 48 Gy)였으며, 생물학적 유효선량(biologic effective dose)은 $31.3{\sim}78.0\;Gy_{10}$ (중앙값 61.6 $Gy_{10}$)였다. 결과: 치료 반응평가는 치료 전과 치료 종료 후 최소 1개월 이상 경과 후 컴퓨터 단층촬영(CT)을 시행하여 평가하였으며, 대상 환자들의 추적관찰기간은 $2{\sim}24$개월(중앙값 9개월)이었다. 방사선치료 후 완전반응인 경우가 2명(2.9%), 부분반응 31명(44.3%), 무반응 35명(50.0%), 진행병변 2명(2.9%)이었다. 1년 무진행 생존율(progression-free survival)은 60%였으며, 중앙 무진행 생존기간은 17개월이었다. 전체 환자의 중앙 생존기간(overall survival)은 11개월이었으며, 치료반응 유무에 따라 부분 반응 이상을 보인 환자군의 중앙 생존기간은 15개월, 무반응이거나 진행병변을 보인 환자군은 8개월로 통계학적 차이를 보였다(p=0.032). 치료 중 일시적인 간기능 저하가 4명(5.7%), 방사선 간염은 1명(1.4%)에서 발생하였다. 결론: 진행된 간세포암에서의 간문맥 혈전에 대해 방사선치료를 시행한 경우 비교적 유용하며 안전한 치료법이며, 앞으로의 연구에서는 방사선치료가 생존율을 향상시킬 수 있는지 여부와 적절한 방사선량을 결정하기 위한 연구가 필요할 것으로 생각된다.

태권도 숙련자와 미숙련자의 공격뒤차기 동작에 대한 운동학적 분석 (The Kinematic Analysis of Back-Kick Motion in Taekwondo)

  • 이동진;박찬호;김헌수
    • 한국운동역학회지
    • /
    • 제16권3호
    • /
    • pp.43-51
    • /
    • 2006
  • The purpose of this study was to analyze kinematic variables during turing back kick motion of Taekwondo. The subjects of this study were the 4 skilled and 4 unskilled of male university player in respectively. The experiment of this study was used two 16mm high speed cameras and its speed 125 frames/s. Analysis of this data was three dimensional cinematography using KWON3D program package. The results were as following; 1. In the elapsed time, there was no significance difference statically between a skilled and unskilled group. But skilled group was more fast during the motion of I phase. And unskilled group was more fast during the motion of II phase so called force production section, which had an influence on Diechagi's velocity. 2. In the center of gravity of human body, the changing of it was $1.10{\pm}0.04m$, $1.12{\pm}0.03m$ of LFM(left foot movement) and $1.36{\pm}0.08m$, $1.39{\pm}0.09m$ of RKF(right knee flection), and $1.44{\pm}0.08m$, $1.42{\pm}0.09m$ of RFI(right foot impact). There was no significance difference statically between the two groups. 3. The velocity of heel on impact was 1.13m/s in the skilled group and 1.23m/s in the unskilled group, when each angle of knee was $110.4{\pm}10.9deg/s$, $114.8{\pm}28.4deg/s$. The maximum velocity of each performance was reached before the RKF, and the velocity and angle at impact along by two groups did not show any significant difference statically. 4. In the angular velocity of just RKF of lower leg, there was significance difference statically between the two groups(p<.05).

Three-dimensional analysis of dental decompensation for skeletal Class III malocclusion on the basis of vertical skeletal patterns obtained using cone-beam computed tomography

  • Kim, Yong-Il;Choi, Youn-Kyung;Park, Soo-Byung;Son, Woo-Sung;Kim, Seong-Sik
    • 대한치과교정학회지
    • /
    • 제42권5호
    • /
    • pp.227-234
    • /
    • 2012
  • Objective: To evaluate the presurgical orthodontic tooth movement of mandibular teeth after dental decompensation for skeletal Class III deformities on the basis of vertical skeletal patterns. Methods: This cohort was comprised of 62 patients who received presurgical orthodontic treatment. These patients were divided into 3 groups according to their vertical skeletal patterns. Changes in the positions of the mandibular central incisor, canine, premolar, and 1st molar after presurgical orthodontic treatment were measured using a cone-beam computed tomography (CBCT) superimposition method. Results: The incisors moved forward after dental decompensation in all 3 groups. The canines in group I and the 1st premolars in groups I and III also moved forward. The incisors and canines were extruded in groups I and II. The 1st and 2nd premolars were also extruded in all groups. Vertical changes in the 1st premolars differed significantly between the groups. We also observed lateral movement of the canines in group III and of the 1st premolar, 2nd premolar, and 1st molar in all 3 groups (p < 0.05). Conclusions: Movement of the mandibular incisors and premolars resolved the dental compensation. The skeletal facial pattern did not affect the dental decompensation, except in the case of vertical changes of the 1st premolars.