• 제목/요약/키워드: 3-Dimensional D.P.

검색결과 570건 처리시간 0.029초

The Effects of Pilates Exercise Using the Three Dimensional Schroth Breathing Technique on the Physical Factors of Scoliosis Patients

  • HwangBo, Pil Neo
    • The Journal of Korean Physical Therapy
    • /
    • 제30권6호
    • /
    • pp.229-233
    • /
    • 2018
  • Purpose: This study aims to verify the effects of Pilates exercise using the three-dimensional (3D) Schroth breathing technique on scoliosis patients in comparison with the existing Pilates exercise technique, which uses lateral breathing. Methods: The subjects were 16 scoliosis patients who went to S fitness center in Daegu, Korea. They were randomly and equally divided into a Schroth Pilates exercise group (SPEG), who performed Pilates exercise using 3D Schroth breathing, and a Pilates exercise group (PEG) who performed Pilates exercise using lateral breathing. The subjects conducted the Pilates exercise three times per week for 12 weeks. Changes in their Cobb's angle, angle of trunk rotation, and chest expansion ability were measured before and after the exercise. Results: Both groups experienced significant improvement in their Cobb's angle, angle of trunk rotation, and chest expansion ability after the exercise (p<0.05). Between-group comparison after the exercise showed that SPEG's improvement in Cobb's angle, angle of trunk rotation, and chest expansion ability were more significant than those of the PEG (p<0.05). Conclusion: This study verified that Pilates exercise using 3D Schroth breathing was more effective in improving scoliosis patients'physical condition than existing Pilates exercise. The researcher anticipates that the 3D Schroth breathing technique will be effectively utilized in other diverse intervention exercises besides Pilates exercise.

Novel Photocatalytic and Antibacterial Activities of Three-Dimensional (3D) Polycrystalline Anatase TiO2 Structures

  • Lee, Hyun Uk;Yun, Hyung Joong;Son, Byoungchul;Seo, Jung Hye;Kim, Hyeran;Choi, Saehae;Jeon, Cheolho;Kim, Hae Jin;Lee, Jouhahn
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.635-635
    • /
    • 2013
  • We report three-dimensional polycrystalline anatase TiO2 structures (3D a-TiO2) for environmental and bio-medical applications. The 3D a-TiO2 was synthesized without thermal treatment by the growth of rod-like polycrystals on Degussa P25 (P25) via low temperature (< $85^{\circ}C$) modified alkali hydrothermal processing. X-ray diffraction and high-resolution transmission electron microscopic results showed that the rod-like polycrystals of 3D a-TiO2 possessed the highly anatase nanostructures. The photocatalytic activity of 3D a-TiO2 was found to be 2.2 times higher than that of P25. The recyclability of the 3D a-TiO2 was found to be high: the decolorization rate was 94.8% of the initial value after fifteen cycles. In addition, 3D a-TiO2 exhibited excellent antibacterial activities for the sterilization of gram-negative Escherichia coli (E. coli) and gram-positive Staphylococcus aureus (S. aureus). Even at the 10th recycled use, more than 98.4% of E. coli and S. aureus can be killed. These results indicated that 3D a-TiO2 might have utility in several promising applications such as photocatalytic water/air purification and bactericidal agents.

  • PDF

3차원 ZnO 나노구조체 가스센서 (3-dimensional nanostructured ZnO gas sensor)

  • 박용욱;신현용;윤석진
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.356-360
    • /
    • 2010
  • Due to the high surface-to-volume ratio, the 3-dimensional(3D) nanostructures of metal oxides are regarded as the best candidate materials for the chemical gas sensors. Here we have synthesised flower-like 3D zinc oxide nanostructures through a simple hydrothermal route. Specific surface area of the 3D zinc oxide nanostructures synthesised in different pH values from 9.0 to 12.0 were evaluated by using a BET analyzer and the results were compared with that of a zinc oxide thin film fabricated by rf sputtering. Using interdigitated electrodes, superior CO gas sensing properties of the 3D zinc oxide nanostructures on the ZnO thin film to those of the ZnO thin film were demonstrated.

Three-dimensional Capsular Volume Measurements in Multidirectional Shoulder Instability

  • Jun, Yong Cheol;Moon, Young Lae;Elsayed, Moustafa I.;Lim, Jae Hwan;Cha, Dong Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • 제21권3호
    • /
    • pp.134-137
    • /
    • 2018
  • Background: In a previous study undertaken to quantify capsular volume in rotator cuff interval or axillary pouch, significant differences were found between controls and patients with instability. However, the results obtained were derived from two-dimensional cross sectional areas. In our study, we sought correlation between three-dimensional (3D) capsular volumes, as measured by magnetic resonance arthrography (MRA), and multidirectional instability (MDI) of the shoulder. Methods: The MRAs of 21 patients with MDI of the shoulder and 16 control cases with no instability were retrospectively reviewed. Capsular areas determined by MRA were translated into 3D volumes using 3D software Mimics ver. 16 (Materilise, Leuven, Belgium), and glenoid surface area was measured in axial and coronal MRA views. Then, the ratio between capsular volume and glenoid surface area was calculated, and evaluated with control group. Results: The ratio between 3D capsular volume and glenoid surface area was significantly increased in the MDI group ($3.59{\pm}0.83cm^3/cm^2$) compared to the control group ($2.53{\pm}0.62cm^3/cm^2$) (p<0.01). Conclusions: From these results, we could support that capsular volume enlargement play an important role in MDI of the shoulder using volume measurement.

2차원 광밴드갭 나노레이저 (Two-Dimensional Photonic Bandgap Nanolasers)

  • Lee, Y. H.;Hwang, J-K;H.Y. Ryu;Park, H. K.;D. J. Shin
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.2-3
    • /
    • 2001
  • Characteristics of two-dimensional slab photonic crystal lasers will be summarized. Room temperature c.w operation is demonstrated at 1.6 $\mu\textrm{m}$ by using InGaAsP slab-waveguide triangular photonic crystal on top of wet-oxidized aluminum oxide. Recently, 2-D PBG structures have attracted a great deal of attention due to their simplicity in fabrication and theoretical study as compared to the three-dimensional counterparts [1]. Air-guided 2-D slab PBG lasers were reported by Caltech group (2). However, this air-slab structure is mechanically fragile and thermally unforgiving. Therefore, a new structure that can remove this thermal limitation is dearly sought after for 2-D PBG laser to have practical meaning. In this talk, we report room-temperature continuous operation of 2-D photonic bandgap lasers that are thermally and mechanically stable.(omitted)

  • PDF

2차원 사전 정합을 위한 실용적인 알고리즘 (A Practical Algorithm for Two-Dimensional Dictionary Matching)

  • 이광수
    • 한국정보처리학회논문지
    • /
    • 제6권3호
    • /
    • pp.812-820
    • /
    • 1999
  • In two-dimensional dictionary matching problem, we are given a two-dimensional text T and a dictionary D={P\ulcorner, ...., P\ulcorner} as a set of two-dimensional patterns. We seek the locations of all the dictionary patterns that appear in T. We present a new two-dimensional pattern matching algorithm that can handle just a single pattern, and then show how to extend it into two-dimensional dictionary matching algorithm. The suggested algorithm is practical in the sense that it can deal that it uses a small extra space proportional to the size of the dictionary, and that it is quite simple to be implemented without depending on complicated data structures.

  • PDF

DLP 프린터로 제작된 레진 임시수복물의 3차원적 정확도 평가 (A Study of Three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer)

  • 강월;이희경
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.35-41
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of the DLP 3D printer by conducting 3-dimensional assesment of resin provisional restorations. Methods: The first premolar of the maxillary was prepared for the abutment. The abutment was scanned by using a scanner. The provisional restoration was designed by using CAD software. A total of 16 resin provisional restorations were produced using ZD200 and Veltz DLP 3D printer. Scanning was done of resin provisional restorations and 3-dimensional measurement was conducted for accuracy. The mean (SD) of RMS was reported for each group. Independent t-test was used to assess the statistical significance of the results. All analyses were done using SPSS 22.0. Results: The mean ± SD of RMS value for the accuracy of the resin provisional restorations that was fabricated by using ZD200 and Veltz DLP 3D printer were 50.85.±4.64㎛ and 70.33±6.31㎛. Independent t-test showed significant differences between groups(p<0.001). Conclusion: The resin provisional restorations made with DLP 3D printers showed clinically acceptable accuracy.

Validity of Three-dimensional Superimposition of Whole Face according to Different Registration Areas

  • Oh, Min-Hee;Jung, Chaeyong;Jeon, Sang-Woon;Cho, Jin-Hyoung
    • Journal of Korean Dental Science
    • /
    • 제12권2호
    • /
    • pp.39-47
    • /
    • 2019
  • Purpose: This study was aimed to evaluate whether the size of the changed area included in the registration area affects the validity of superimposition in three-dimensional (3D) images. Materials and Methods: Ten mannequin heads which were sectioned to simulate maxillary and mandibular setback surgery were used. A total of 30 images, including 10 initial images, 10 images after moving both middle and lower faces, and 10 images after moving only lower face, were obtained. The 9 landmarks which consisted of the bilateral and midline landmarks of the upper, middle, and lower faces respectively were used. Each 3D image obtained after simulation was superimposed 3 times according to the different 3 registration areas. The one-way ANOVA and posthoc analysis were performed. Result: In the case of moving middle and lower faces, there was no significant difference in all markers when superimposition was performed based on no changed area and forehead area. However, in the case of superimposition by the whole face, all measurements showed a significant difference (P<0.05) except for Pn (P>0.05). In the case of moving only lower face, all measurements did not show a significant difference regardless of the registration area. Conclusion: The validity of 3D superimposition in 3D images could be affected by the size of changed areas included in the registration area. In the postoperative evaluation of mandibular surgery, the registration area does not affect the accuracy of the 3D superposition. However, after the maxilla-mandibular surgery, the registration area should be set except for the changed soft tissue.

Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green

  • Cho, Steve S.;Teng, Clare W.;Ravin, Emma De;Singh, Yash B.;Lee, John Y.K.
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권4호
    • /
    • pp.572-581
    • /
    • 2022
  • Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with near-infrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. Methods : Serial dilutions of indocyanine-green (1-2000 ㎍/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 ㎍/L and >31.3 ㎍/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadolinium-enhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.