• 제목/요약/키워드: 3-Dimensional D.P.

검색결과 574건 처리시간 0.025초

Phase Diagrams and Stable Structures of Stranski-Krastanov Structure Mode for III-V Ternary Quantum Dots

  • Nakaima, Kazuno;Ujihara, Toru;Miyashita, Satoru;Sazaki, Gen
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1999년도 PROCEEDINGS OF 99 INTERNATIONAL CONFERENCE OF THE KACG AND 6TH KOREA·JAPAN EMG SYMPOSIUM (ELECTRONIC MATERIALS GROWTH SYMPOSIUM), HANYANG UNIVERSITY, SEOUL, 06월 09일 JUNE 1999
    • /
    • pp.81-114
    • /
    • 1999
  • The strain, surface and inerfacial energies of III-V ternary systems were calculated for three kinds of structure modes: the Frank-van der Merwe (FM) mode, the Stranski-Krastanov (SK) mode an the Volmer-Wever (VW) mode. The free energy for each mode was estimated as functions of the thickness and composition or lattice misfit. Through comparison of the free energy of each mode, it was found that the thickness-composition phase diagrams of III-V ternary systems can be determined only by considering the balance of the free energy and three kinds of structure modes appear in the phase diagrams. The SK mode appears only when the lattice misfit is large and/or the lattice layer is thick. The most stable structure of the SK mode is a cluster with four lattice layers or minimum thickness on a wetting layer of increasing lattice layers. The VW mode appears when the lattice misfit is large and the lattice layer is thin and only in the InPSb/InP and GaPSb/GaP systems which have the largest lattice misfit of III-V ternary systems. The stable region of the SK mode in the GaPSb/GaP and InPSb/InP phase diagrams is largest of all because the composition dependence of the strain energy of these systems is stronger than that of the other systems. The critical number of lattice layers below which tow-dimensional (2D) layers precede the three-dimensional (3D) nucleation in the SK mode at x=1.0 depnds on the lattice misfit.

  • PDF

구리밀봉 증기발생기의 열적크기 계산을 위한 프로그램 개발 (Development of a Computer Program for Thermal Sizing of a Copper Bonded Steam Generator)

  • 김의광;김연식;어재혁;김성오;백병준
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.84-92
    • /
    • 2003
  • 구리밀봉 증기발생기의 열적크기 계산을 위한 1차원 열수력코드를 개발하였다. 고온 및 저온측 전열관사이의 구리의 열전도는 1차원으로 가정하고, 전열관 피치의 함수로 열저항을 구하였다 물/증기측 유동영역은 아냉, 포화핵비등, 포화막비등, 과열영역의 4 구간으로 구분하였다. 매개변수 연구를 위한 전열관 갯수는 250에서 3500이며, P/D비율은 각각1.4, 1.6, 1.8로 하였다. 계산결과, 전열관 갯수가 2500일 때 전열관 길이는 약 12 m, 직경은 약 3 m이다. P/D를 증가시키면 구리에 의한 열저항 성분이 증가하지만 전열관 길이는 큰 차이가 없음을 알 수 있었다.

The difference in the location of the malar summit between genders in Southeast Asians with appropriate references

  • Jirawatnotai, Supasid;Sriswadpong, Papat
    • 대한두개안면성형외과학회지
    • /
    • 제22권2호
    • /
    • pp.78-84
    • /
    • 2021
  • Background: Facial feminization surgery and malarplasty require information concerning facial features in the malar area. Such information varies as a function of sex and race. The objectives of this study aimed to quantitatively evaluate the location of malar prominence across sexes in the Southeast Asian population, and identify sex-specific differences in malar prominence using a combination of two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) CT. Methods: The location of malar prominence was evaluated in 101 Thai adults, consisting of 52 men and 49 women. This study used both 2D CT and 3D CT to achieve greater accuracy, in which 2D CT was used to measure malar distance, malar summit width, facial width, and malar summitto-facial width ratio whereas 3D CT was used to evaluate the positional relationship between the zygomatic summit and four reference points of the zygoma. Results: The malar summit was positioned more laterally in males (p< 0.01) and was more projected in females (p= 0.01). The other 2D-parameters were wider in males. The ratio between the malar summit width and facial width showed similar results for both sexes. The vertical dimension did not show any statistically significant differences; however, a higher summit position was observed in males. Conclusion: The zygomatic summit is positioned more laterally in males and is more projected in females. However, the ratio was similar, which indicates that the male cranium is larger in size. Based on the results in this study, when facial feminization surgery or malarplasty is performed on a Southeast Asian patient, the malar bone should be reduced horizontally and moved forward for better outcomes.

Investigation into Electrical Characteristics of Logic Circuit Consisting of Modularized Monolithic 3D Inverter Unit Cell

  • Lee, Geun Jae;Ahn, Tae Jun;Lim, Sung Kyu;Yu, Yun Seop
    • Journal of information and communication convergence engineering
    • /
    • 제20권2호
    • /
    • pp.137-142
    • /
    • 2022
  • Monolithic three-dimensional (M3D) logics such as M3D-NAND, M3D-NOR, M3D-buffer, M3D 2×1 multiplexer, and M3D D flip-flop, consisting of modularized M3D inverters (M3D-INVs), have been proposed. In the previous M3D logic, each M3D logic had to be designed separately for a standard cell library. The proposed M3D logic is designed by placing modularized M3D-INVs and connecting interconnects such as metal lines or monolithic inter-tier-vias between M3D-INVs. The electrical characteristics of the previous and proposed M3D logics were simulated using the technology computer-aided design and Simulation Program with Integrated Circuit Emphasis with the extracted parameters of the previously developed LETI-UTSOI MOSFET model for n- and p-type MOSFETs and the extracted external capacitances. The area, propagation delay, falling/rising times, and dynamic power consumption of the proposed M3D logic are lower than those of previous versions. Despite the larger space and lower performance of the proposed M3D logic in comparison to the previous versions, it can be easily designed with a single modularized M3D-INV and without having to design all layouts of the logic gates separately.

Clinical Observation of Three Dimensional Conformal Radiotherapy with Tamoxifen in Treatment of Postoperative Malignant Glioma

  • Zhou, Shao-Bing;Liu, Yang-Chen;Yin, Xiao-Xiang;Ding, Wen-Xiu;Guo, Xin-Wei;Gu, Liang;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1743-1745
    • /
    • 2015
  • Objective: To evaluate the efficacy and adverse effects of three dimensional conformal radiotherapy (3D-CRT) with tamoxifen in treating patients with postoperative malignant glioma. Patients and Methods: 60 patients of postoperative malignant glioma were randomly assigned into two groups, 30 patients were treated with 3D-CRT plus tamoxifen (treatment group), and the other 30 patients with 3D-CRT plus temozolomide (control group). All patients were radiated by 6MV X-ray, 2.0Gy per fraction, once daily, with a total dose (DT) of 56~60Gy. Tamoxifen was delivered at $60mg/m^2/d$, temozolomide was given at $75mg/m^2/d$. All patients were treated with concurrent radiotherapy. Results: One, 2, 3 year survival rates of treatment and control group were 63.3%, 30.0%, 23.0% and 70.0%, 33.3%, 26.7%, respectively (${\chi}^2=0.01$, 0.23, 0.09, P>0.05). The rate of thromboembolism in treatment group was 6.7%. Conclusion: Therapeutic efficacy of two groups was similar, but it was more cost-effective in treatment group, and toxicity did not increase.

Changes in the hyoid bone, tongue, and oropharyngeal airway space after mandibular setback surgery evaluated by cone-beam computed tomography

  • Kim, Seon-Hye;Choi, Sung-Kwon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.27.1-27.9
    • /
    • 2020
  • Background: Mandibular setback surgery can change the position of the mandible which improves occlusion and facial profile. Surgical movement of the mandible affects the base of the tongue, hyoid bone, and associated tissues, resulting in changes in the pharyngeal airway space. The aim of this study was to analyze the 3-dimensional (3D) changes in the hyoid bone and tongue positions and oropharyngeal airway space after mandibular setback surgery. Methods: A total of 30 pairs of cone-beam computed tomography (CBCT) images taken before and 1 month after surgery were analyzed by measuring changes in the hyoid bone and tongue positions and oropharyngeal airway space. The CBCT images were reoriented using InVivo 5.3 software (Anatomage, San Jose, USA) and landmarks were assigned to establish coordinates in a three-dimensional plane. The mean age of the patients was 21.7 years and the mean amount of mandibular setback was 5.94 mm measured from the B-point. Results: The hyoid bone showed significant posterior and inferior displacement (P < 0.001, P < 0.001, respectively). Significant superior and posterior movements of the tongue were observed (P < 0.05, P < 0.05, respectively). Regarding the velopharyngeal and glossopharyngeal spaces, there were significant reductions in the volume and minimal cross-sectional area (P < 0.001). The anteroposterior and transverse widths of the minimal cross-sectional area were decreased (P < 0.001, P < 0.001, respectively). In addition, the amount of mandibular setback positively correlated with the amount of posterior and inferior movement of the hyoid bone (P < 0.05, P < 0.05, respectively). Conclusion: There were significant changes in the hyoid bone, tongue, and airway space after mandibular setback surgery.

3D stability of pile stabilized stepped slopes considering seismic and surcharge loads

  • Long Wang;Meijuan Xu;Wei Hu;Zehang Qian;Qiujing Pan
    • Geomechanics and Engineering
    • /
    • 제32권6호
    • /
    • pp.639-652
    • /
    • 2023
  • Stepped earth slopes incorporated with anti-slide piles are widely utilized in landslide disaster preventions. Explicit consideration of the three-dimensional (3D) effect in the slope design warrants producing more realistic solutions. A 3D limit analysis of the stability of pile stabilized stepped slopes is performed in light of the kinematic limit analysis theorem. The influences of seismic excitation and surcharge load are both considered from a kinematic perspective. The upper bound solution to the factor of safety is optimized and compared with published solutions, demonstrating the capability and applicability of the proposed method. Comparative studies are performed with respect to the roles of 3D effect, pile location, pile spacing, seismic and surcharge loads in the safety assessments of stepped slopes. The results demonstrate that the stability of pile reinforced stepped slopes differ with that of single stage slopes dramatically. The optimum pile location lies in the upper portion of the slope around Lx/L = 0.9, but may also lies in the shoulder of the bench. The pile reinforcement reaches 10% universally for a looser pile spacing Dc/dp = 5.0, and approaches 70% when the pile spacing reaches Dc/dp = 2.0.

EEG 생체신호 기반 3D 시각피로 측정방법에 대한 타당화 연구 (Validity examination of the measurement of 3D visual fatigue using EEG)

  • 이형철;문경애
    • 감성과학
    • /
    • 제15권1호
    • /
    • pp.17-28
    • /
    • 2012
  • 최근의 디스플레이 기술은 2차원 디스플레이에 제시된 영상으로부터 3차원 깊이감을 지각하는 것을 가능하게 하였다. 이런은 디스플레이와 콘텐츠 기술의 발전에도 불구하고, 사용자는 실생활에서 경험하지 않는 시각피로의 문제를 경험하는데, 이 문제를 해결하기 위해서는 시각피로를 안정적이고 타당하게 측정하는 것이 필요하다. 본 연구의 목적은 EEG(Electroencephalography)신호에 기반한 시각피로 측정의 프로토콜을 개발하고 타당성을 검증하는 것이었다. ERP(Event related potential) 성분 중에서 시각피로를 반영하는 성분을 찾아내기 위해 2D 조건과 3D 조건에서 탐색적 실험을 수행하였고, 탐색적 실험에서 발견된 ERP 성분이 양안시차의 차이에 따라 상이한 특성을 보이는지 검증하기 위하여 확인적 실험을 수행하였다. 실험결과, Cz와 Pz 영역에서 P3 성분의 정점 강도가 2D 조건보다는 3D 조건에서 감소하였으며, 양안시차가 증가할수록 일관되게 P3 성분의 강도가 통계적으로 유의하게 감소하는 것을 확인하였다. 양안시차가 증가함에 따라서 주관적인 시각피로가 통계적으로 유의하게 증가함을 검증하였는데, 이 실험결과는 Cz와 Pz 영역에서의 P3 성분의 정점 강도가 3D 시각피로에 대한 인덱스로 사용할 수 있음을 시사한다.

  • PDF

Plate prebending using a three-dimensional-printed model affords effective anatomical reduction in clavicular shaft fractures

  • Hyungsuk Kim;Younsung Jung;Hyun Seok Song
    • Clinics in Shoulder and Elbow
    • /
    • 제26권4호
    • /
    • pp.397-405
    • /
    • 2023
  • Background: A precontoured plate rarely fits properly within the patient's clavicle and must be bent intraoperatively. This study aimed to determine whether anatomical reduction could be achieved using a plate bent before surgery. Methods: This study included 87 consecutive patients with displaced mid-shaft clavicle fractures who underwent plate fixation and were followed-up for a minimum of 1 year. After exclusions, 39 consecutive patients underwent fixation with a precontoured plate bent intraoperatively (intraoperative bending group), and 28 underwent fixation with the plate bent preoperatively (preoperative bending group). Using free software and a three-dimensional (3D) printer, ipsilateral clavicle 3D-printed models were constructed. Using plain radiographs, the distance between the edge of the lateral inferior cortex and the medial inferior cortex was measured. The angle between the line connecting the inferior cortex edge and the line passing through the flat portion of the superior cortex of the distal clavicle was measured. Results: Mean length differences between the ipsilateral and contralateral clavicle were smaller on both anteroposterior (AP; P=0.032) and axial images (P=0.029) in the preoperative bending group. The mean angular differences on both AP (P=0.045) and axial images (P=0.008) were smaller in the preoperative bending group. No significant differences were observed between the two groups in functional scores at the last follow-up. Conclusions: Smaller differences in length and angle between the ipsilateral and contralateral clavicle, indicative of reduction, were observed in the preoperative bending group. Using the precontoured technique with low expense, the operation was performed more effectively as reflected by a shorter operation time. Level of evidence: III.

고성능 전기 화학 pH 센서를 위한 유연한 3차원 다공성 폴리아닐린 필름 제조 (Preparation of Flexible 3D Porous Polyaniline Film for High-Performance Electrochemical pH Sensor)

  • 박홍준;박승화;김호준;이경균;최봉길
    • 공업화학
    • /
    • 제31권5호
    • /
    • pp.539-544
    • /
    • 2020
  • 본 연구에서는 넓은 면적의 나노필라 배열 필름을 기반으로 포토 및 소프트 리소그래피 기술과 화학적 희석 고분자 중합을 조절하여 3차원 다공성의 폴리아닐린 필름을 제조하였다. 3차원 폴리아닐린 필름은 계층 간 연결된 폴리아닐린 나노파이버들로 구성되어 있어, 넓은 표면적과 개방형의 다공성 구조를 가지는 3차원 계층형 나노웹 필름을 형성한다. 전기화학분석법을 기반으로 3차원 폴리아닐린 필름이 유연한 pH 센서 전극이 되는 것을 증명하였다. 3차원 폴리아닐린 필름은 이상적인 네른스트 거동과 근접한 60.3 mV/pH의 높은 민감도를 보였다. 또한, 3차원 폴리아닐린 전극은 10 min의 빠른 반응 속도, 우수한 반복성 그리고 높은 선택성을 나타내었다. 3차원 폴리아닐린 전극을 기계적으로 굽힌 상태에서 센서 특성을 측정하였을 때, 전극이 60.4 mV/pH의 높은 민감도를 보여줌으로써, 유연한 pH 센서 성능을 증명하였다.