• 제목/요약/키워드: 3-Dimensional D.P.

검색결과 568건 처리시간 0.026초

Marginal microleakage of cervical composite resin restorations bonded using etch-and-rinse and self-etch adhesives: two dimensional vs. three dimensional methods

  • Khoroushi, Maryam;Ehteshami, Ailin
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.83-90
    • /
    • 2016
  • Objectives: This study was evaluated the marginal microleakage of two different adhesive systems before and after aging with two different dye penetration techniques. Materials and Methods: Class V cavities were prepared on the buccal and lingual surfaces of 48 human molars. Clearfil SE Bond and Single Bond (self-etching and etchand-rinse systems, respectively) were applied, each to half of the prepared cavities, which were restored with composite resin. Half of the specimens in each group underwent 10,000 cycles of thermocycling. Microleakage was evaluated using two dimensional (2D) and three dimensional (3D) dye penetration techniques separately for each half of each specimen. Data were analyzed with SPSS 11.5 (SPSS Inc.), using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=0.05$). Results: The difference between the 2D and 3D microleakage evaluation techniques was significant at the occlusal margins of Single bond groups (p = 0.002). The differences between 2D and 3D microleakage evaluation techniques were significant at both the occlusal and cervical margins of Clearfil SE Bond groups (p = 0.017 and p = 0.002, respectively). The difference between the 2D and 3D techniques was significant at the occlusal margins of non-aged groups (p = 0.003). The difference between these two techniques was significant at the occlusal margins of the aged groups (p = 0.001). The Mann-Whitney test showed significant differences between the two techniques only at the occlusal margins in all specimens. Conclusions: Under the limitations of the present study, it can be concluded that the 3D technique has the capacity to detect occlusal microleakage more precisely than the 2D technique.

입체 TV 영상(3D) 주시시의 유발전위 (Change of electroencephalograph during 3-dimensional image load)

  • 조암
    • 대한인간공학회지
    • /
    • 제9권2호
    • /
    • pp.29-35
    • /
    • 1990
  • To investigate and analyze of the human brain-wave changes during 3-dimenslonal image load were expected to take not only an important basic information of 3-dimensional TV usage but also 3-dimensional image design. In this experiment, to analyze the difference of visual analyze handing system for which we present the 2- dimensional image having no parallex and 3-dimensional image by visual evoked potentials(VEP). 2-dimensional image and 3-dimensional image displayed on the screen through video. In the test, the time interval was one sec for presentation of stimulus considering united time of visual information of right eye and left eye during watching the 3-dimensional image also display time interval was 200 mesc for each stimulus image. Results are as follow, (1) N190 appears faster 16msec-20msec in the point of Fz, Cz, Pz, Oz when loaded 3D4 angle than 2D3 angle. (2) About of the P300, 3D4 angle(Otherwise, Oz point was reverse) and in the case of no equipment of liquid crystal shutter, there appeared PEAK near the P250. (3) There were 5% significant difference when the liquid crystal shutter was equiped and didn't, Therefore, this phenomenon show the possibility that Liquid crystal shutter influences on Visual Evoked Potentials.

  • PDF

Technical Improvement Using a Three-Dimensional Video System for Laparoscopic Partial Nephrectomy

  • Komatsuda, Akari;Matsumoto, Kazuhiro;Miyajima, Akira;Kaneko, Gou;Mizuno, Ryuichi;Kikuchi, Eiji;Oya, Mototsugu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권5호
    • /
    • pp.2475-2478
    • /
    • 2016
  • Background: Laparoscopic partial nephrectomy is one of the major surgical techniques for small renal masses. However, it is difficult to manage cutting and suturing procedures within acceptable time periods. To overcome this difficulty, we applied a three-dimensional (3D) video system with laparoscopic partial nephrectomy, and evaluated its utility. Materials and Methods: We retrospectively enrolled 31 patients who underwent laparoscopic partial nephrectomy between November 2009 and June 2014. A conventional two-dimensional (2D) video system was used in 20 patients, and a 3D video system in 11. Patient characteristics and video system type (2D or 3D) were recorded, and correlations with perioperative outcomes were analyzed. Results: Mean age of the patients was $55.8{\pm}12.4$, mean body mass index was $25.7{\pm}3.9kg/m^2$, mean tumor size was $2.0{\pm}0.8cm$, mean R.E.N.A.L nephrometry score was $6.9{\pm}1.9$, and clinical stage was T1a in all patients. There were no significant differences in operative time (p=0.348), pneumoperitoneum time (p=0.322), cutting time (p=0.493), estimated blood loss (p=0.335), and Clavien grade of >II complication rate (p=0.719) between the two groups. However, warm ischemic time was significantly shorter in the 3D group than the 2D group (16.1 min vs. 21.2min, p=0.021), which resulted from short suturing time (9.1 min vs. 15.2 min, p=0.008). No open conversion occurred in either group. Conclusions: A 3D video system allows the shortening of warm ischemic time in laparoscopic partial nephrectomy and thus may be useful in improving the procedure.

Evaluation of Tooth Movement and Arch Dimension Change in the Mandible Using a New Three-dimensional Indirect Superimposition Method

  • Oh, Hyun-Jun;Baek, Seung-Hak;Yang, Il-Hyung
    • Journal of Korean Dental Science
    • /
    • 제7권2호
    • /
    • pp.66-79
    • /
    • 2014
  • Purpose: To analyze the amount and pattern of tooth movement and the changes in arch dimension of mandibular dentition after orthodontic treatment using a new three-dimensional (3D)-indirect superimposition method. Materials and Methods: The samples consisted of fifteen adult patients with class I bialveolar protrusion and minimal anterior crowding, treated by extraction of four first premolars with conventional sliding mechanics. After superimposition of 3D-virtual maxillary models before and after treatment using best-fit method, 3D-virtual mandibular model at each stage was placed into a common coordinate of superimposition using 3D-bite information, which resulted in 3D-indirect superimposition for mandibular dentition. The changes in mandibular dental and arch dimensional variables were measured with Rapidform 2006 (INUS Technology). Paired t-test was used for statistical analysis. Result: The anterior teeth moved backward, displaced laterally, and inclined lingually. The posterior teeth showed statistically significant contraction toward midsagittal plane. The amounts of backward movement of anterior teeth and forward movement of posterior teeth showed a ratio of 6 : 1. Although the inter-canine width increased slightly (0.8 mm, P<0.05), the inter-second premolar, inter-first molar, and inter-second molar widths decreased significantly with similar amounts (2.2 mm, P<0.05; 2.3 mm, P<0.01; 2.3 mm, P<0.001). The molar depth decreased (6.7 mm, P<0.001) but canine depth did not change. Conclusion: A new 3D-indirect superimposition of the mandibular dentitions using best-fit method and 3D-bite information can present a guideline for virtual treatment planning in terms of tooth position and arch dimension.

Evaluation of Knee Joint after Double-Bundle ACL Reconstruction with Three-Dimensional Isotropic MRI

  • Jung, Min ju;Jeong, Yu Mi;Lee, Beom Goo;Sim, Jae Ang;Choi, Hye-Young;Kim, Jeong Ho;Lee, Sheen-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.95-104
    • /
    • 2016
  • Purpose: To evaluate the knee joint after double-bundle anterior cruciate ligament (ACL) reconstruction with three-dimensional (3D) isotropic magnetic resonance (MR) image, and to directly compare the ACL graft findings on 3D MR with the clinical results. Materials and Methods: From January 2009 to December 2014, we retrospectively reviewed MRIs of 39 patients who had reconstructed ACL with double bundle technique. The subjects were examined using 3D isotropic proton-density sequence and routine two-dimensional (2D) sequence on 3.0T scanner. The MR images were qualitatively evaluated for the intraarticular curvature, graft tear, bony impingement, intraosseous tunnel cyst, and synovitis of anteromedial and posterolateral bundles (AMB, PLB). In addition anterior tibial translation, PCL angle, PCL ratio were quantitatively measured. KT arthrometric values were reviewed for anterior tibial translation as positive or negative. The second look arthroscopy results including tear and laxity were reviewed. Results: Significant correlations were found between an AMB tear on 3D-isotropic proton density MR images and arthroscopic proven AMB tear or laxity (P < 0.05). Also, a significant correlation was observed between increased PCL ratio on 3D isotropic MRI and the arthroscopic findings such as tear, laxities of grafts (P < 0.05). KT arthrometric results were found to be significantly correlated with AMB tears (P < 0.05) and tibial tunnel cysts (P < 0.05). Conclusion: An AMB tear on 3D-isotropic MRI was correlated with arthroscopic results qualitatively and quantitatively. 3D isotropic MRI findings can aid the evaluation of ACL grafts after double bundle reconstruction.

3D 프린터용 시멘트 복합체의 배합요인에 따른 출력 품질의 실험적 평가 (Experimental Evaluation of the Effect of the Mixing Design Factors of the Cementitious Composite for 3D Printer on the Printing Quality)

  • 서지석;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권1호
    • /
    • pp.89-96
    • /
    • 2022
  • 이 논문에서는 건설용 ME 방식 3D 프린터로 출력하기 위한 시멘트 복합체 배합의 출력품질을 평가하기 위해 출력 외관의 육안검사와 출력물의 치수 오차율, 압축강도 및 휨강도를 측정하였다. 시험결과, 출력 불연속 정도, 표면 무결성, 형태 유지능력, 출력가능 여부와 같은 4개 지표를 모두 만족하는 우수한 배합은 P1-2, P1-4, P2-5, P2-6으로 나타났다. 3개 지표를 만족하는 배합은 P0-1, P1-1, P1-3, P1-6, P1-7, P2-4으로 나타났다. 이 배합 중 오차율 측정용 중공 원주형 공시체의 직경 치수 오차율과 높이 치수율이 낮은 배합은 P0-1, P2-6로 나타났다. 치수 오차율이 우수한 배합과 그렇지 않은 배합의 압축강도 및 휨강도를 평가한 결과 출력 품질이 우수한 배합의 역학적 특성이 우수한 것으로 나타났다. 그러나, 역학적 특성이 우수한 배합이 반드시 출력 품질이 우수한 것은 아니기 때문에 정확한 품질평가를 위해서는 출력 외관에 대한 육안검사와 치수 오차율 검사를 선행하여 역학적 특성을 검토해야 할 것으로 판단된다.

전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교 (Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull)

  • 강복희;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

Assessment of Posterior Globe Flattening: Two-Dimensional versus Three-Dimensional T2-Weighted Imaging

  • Ann, Jun Hyung;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권3호
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: To compare the frequency of posterior globe flattening between two-dimensional T2-weighted imaging (2D T2WI) and three-dimensional (3D T2WI). Materials and Methods: Sixty-nine patients (31 female; mean age, 44.4 years) who had undergone both 5-mm axial T2WI and sagittal 3D 1-mm isovoxel T2WI of the whole brain for evaluation of various diseases (headache [n = 30], large hemorrhage [n = 19], large tumor or leptomeningeal tumor spread [n = 15], large infarct [n = 3], and bacterial meningitis [n = 2]) were used in this study. Two radiologists independently reviewed both sets of images at separate sessions. Axial T2WI and multi-planar imaging of 3D T2WI were visually assessed for the presence of globe flattening. The optic nerve sheath diameter (ONSD) was measured at a location 4 mm posterior to each globe on oblique coronal imaging reformatted from 3D T2WI. Results: There were significantly more globes showing posterior flattening on 3D T2WI (105/138 [76.1%]) than on 2D T2WI (27/138 [19.6%], P = 0.001). Inter-observer agreement was excellent for both 2D T2WI and 3D T2WI (Cohen's kappa = 0.928 and 0.962, respectively). Intra-class correlation coefficient for the ONSD was almost perfect (Cohen's kappa = 0.839). The globes with posterior flattening had significantly larger ONSD than those without on both 2D and 3D T2WI (P < 0.001; $6.14mm{\pm}0.44$ vs. $5.74mm{\pm}0.44$ on 2D T2WI; $5.90mm{\pm}0.47$ vs. $5.56mm{\pm}0.34$ on 3D T2WI). Optic nerve protrusion was significantly more frequent on reformatted 1-mm 3D T2WI than on 5-mm 2D T2WI (8 out of 138 globes on 3D T2WI versus one on 2D T2WI; P = 0.018). Conclusion: Posterior globe flattening is more frequently observed on 3D T2WI than on 2D T2WI in patients suspected of having increased intracranial pressure. The globes with posterior flattening have significantly larger ONSD than those without.

두 평면 전극 사이의 절연체 구조물에 의해 유도되는 양의 유전영동을 이용한 삼차원 입자 정렬기 (A Three-Dimensional Particle Focusing Channel Using the Positive Dielectrophoresis (pDEP) Guided by a Dielectric Structure Between Two Planar Electrodes)

  • 추현정;도일;조영호
    • 대한기계학회논문집A
    • /
    • 제33권3호
    • /
    • pp.261-264
    • /
    • 2009
  • We present a three-dimensional (3D) particle focusing channel using the positive dielectrophoresis (pDEP) guided by a dielectric structure between two planar electrodes. The dielectric structure between two planar electrodes induces the maximum electric field at the center of the microchannel, and particles are focused to the center of the microchannel by pDEP as they flow from the single sample injection port. Compared to the previous 3D particle focusing methods, the present device achieves the simple and effective particle focusing function without any additional fluidic ports and top electrodes. In the experimental study, approximately 90 % focusing efficiency were achieved within the focusing length of 2mm, on both x-z plane (top-view) and y-z plane (side-view) for $2{\mu}m$-diameter polystyrene (PS) bead at the applied voltage over 15 Vp-p (square wave) and at the flow rate below 0.01 ${\mu}l$/min. The present 3D particle focusing channel results in a simple particle focusing method suitable for use in integrated microbiochemical analysis system.

Precise Comparison of Two-dimensional Dopant Profiles Measured by Low-voltage Scanning Electron Microscopy and Electron Holography Techniques

  • Hyun, Moon-Seop;Yoo, Jung-Ho;Kwak, Noh-Yeal;Kim, Won;Rhee, Choong-Kyun;Yang, Jun-Mo
    • Applied Microscopy
    • /
    • 제42권3호
    • /
    • pp.158-163
    • /
    • 2012
  • Detailed comparison of low-voltage scanning electron microscopy and electron holography techniques for two-dimensional (2D) dopant profiling was carried out with using the same multilayered p-n junction specimen. The dopant profiles obtained from two methods are in good agreement with each other. It demonstrates that reliability of dopant profile measurement can be increased through precise comparison of 2D profiles obtained from various microscopic techniques.