• 제목/요약/키워드: 3-D ultrasonic image

검색결과 43건 처리시간 0.024초

삼차원 초음파 의료 영상의 입체 묘사 기법 연구 (A Study on Volume Visualization Method of Three-Dimensional Ultrasonic Medical Image)

  • 최정필;하명환;나종범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.45-48
    • /
    • 1995
  • Visualization of three dimensional medical images has been studied in many ways. For CT and MRI data, 3D rendering schemes are commercially available and widly used. However visualization of ultrasonic 3D data is not popular yet, even though its potentional in medical diagnosis seems very high. In this paper we try to visualize 3D ultrasonic data. The basic method is adopted from the volume rendering technique. Based on the characteristics of the ultrasonic images, 3D visualization algorithm is developed and applied for the 3D image set of a dog heart.

  • PDF

EMD를 이용한 초음파 비파괴 평가용 3차원 영상처리 소프트웨어 개발 (Development of 3D Image Processing Software using EMD for Ultrasonic NDE)

  • 남명우;이영석;양옥렬
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1569-1573
    • /
    • 2008
  • 본 논문은 핵발전소 증기발생기의 초음파 비파괴 검사용 프로그램 개발에 관한 것이다. 개발된 프로그램은 A, B, C, D-스캔과 같은 고전적인 해석방법뿐만 아니라 3차원 영상처리 기법을 이용하여 증기발생기 내부에 발생한 결함을 해석하고 검출할 수 있다. 결함의 3차원 영상은 핵발전소의 파이프라인으로부터 얻어진 1차원 초음파 데이터를 EMD(Empirical Mode Decomposition)로 분석해 결함의 위치를 구하고 voxel을 이용하여 구현하였다. 얻어진 3차원 영상은 2차원 해석방법을 사용하지 않더라도 결함의 위치, 형태, 크기 등과 같은 유용한 정보를 얻는데 용이하다. 개발된 프로그램은 이미 결함의 위치 및 모양, 크기 등을 알고 있는 시편의 측정에 사용하여 프로그램의 정확성을 검증하였고, 3차원 영상으로 결함의 입체적 모양을 구현하였다.

3차원 의료기기용 초음파진단기 프로브 개발 (Development of a Ultrasound Probe for 3-D Ultrasonic Imaging)

  • 박종수;김성래;남윤수
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

다공질 압전소자로 제작한 초음파 트랜스듀서와 신경회로망을 이용한 3차원 수중 물체복원 (3-D underwater object restoration using ultrasonic transducer fabricated with porous piezoelectric resonator and neural network)

  • 조현철;박정학;사공건
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권8호
    • /
    • pp.825-830
    • /
    • 1996
  • In this study, Characteristics of Ultrasonic Transducer fabricated with porous piezoelectric resonator, 3-D underwater object restoration using the self made ultrasonic transducer and modified SCL(Simple Competitive Learning) neural network are investigated. The self-made transducer was satisfied the required condition of ultrasonic transducer in water, and the modified SCL neural network using the acquired object data 16*16 low resolution image was used for object restoration of $32{\times}32$ high resolution image. The experimental results have shown that the ultrasonic transducer fabricated with porous piezoelectric resonator could be applied for SONAR system.

  • PDF

시간 영역에서 획득된 초음파 영상의 심내강 영역에 대한 3차원 표현 (3-D Representation of Cavity Region from Ultrasonic Image Acquired in the Time Domain)

  • 원철호;채승표;구성모;김명남;조진호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.119-122
    • /
    • 1997
  • In this paper, we represented the variation of heart cavity area in the space domain by 3-d rendering. We arranged the 2-d sequence of ultrasonic image acquired in the time domain as volumetric data, and extracted heart cavity region from 3-d data. For the segmentation of 3-d volume data, we extracted the cavity region using the method of expanding the cavity region that is same statistical property. By shading which is using light and object normal vector, we visualized the volume data on image plane.

  • PDF

1-3형 복합압전체로 제작한 초음파 트랜스듀서와 신경회로망을 이용한 3차원 수중 물체복원 (3-D Underwater Object Restoration Using Ultrasonic Transducer Fabricated with 1-3 Type Piezoceramic/Polymer Composite and Neural Networks)

  • 조현철;이기성;최헌일;사공건
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권6호
    • /
    • pp.456-461
    • /
    • 1999
  • In this study, the characteristics of Ultrasonic Transducer fabricated with PZT-Polymer 1-3 type piezoelectric ceramic/polymer composite are investigated. 3-D underwater object restoration using the self-made ultrasonic transducer and modified SCL(Simple Competitive Learning) neural network was presented. The ultrasonic transducer was satisfied with the required condition of commerical ultrasonic transducer in underwater. The modified SCL neural network using the acquired object data $16\times16$ low resolution image was used for object restoration of $32\times32$ high resolution image. The experimental results have shown that the ultrasonic transducer fabricated with PZT-Polymer 1-3 type piezoelectric ceramic/polymer composite could be applied for SONAR system.

  • PDF

초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과 (Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images)

  • 양정화;강관석;이경성;팽동국;최민주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.277-283
    • /
    • 2009
  • 임상에서 정확한 진단을 위해 양질의 초음파 영상을 얻는 것은 중요하다. 본 연구에서는 초음파 진단기의 주파수와 동적 영역(dynamic range, DR) 설정 및 프로브 유형에 따른 초음파 영상의 변화를 관찰하였다. 실험에서 고형 및 낭성 종괴 병변과 유사한 초음파 평가 팬텀(539,551, ATS, USA)의 6가지 LCS(low contrast sensitivity) 표적(-15, -6, -3, +3, +6, +15 dB)에 대한 영상을 대상으로 평가하였다. 초음파 영상은 볼록형(convex, C3-7IM) 및 선형(linear probe, L5-12IM) 두 가지 탐촉자(Probe)에 대해 SA-9900(Medison Ltd, Korea)을 이용하여 얻었다. 주파수는 4가지 방식(gen, pen, res, harmonic), 동적영역은 $40{\sim}100\;dB$ 범위에서 설정을 변화하면서 영상을 취득하였다. 취득한 영상의 질은 표적의 명목상 LCS 값과 영상에서 측정된 LCS을 비교하여 평가 하였다. 실험 결과 볼록형 탐촉자의 경우, 각 LCS 표적에 대해 주파수 방식 별로 동적영역 값을 40, 60, 80, 100 dB로 변화할 때, 초음파 영상의 질은 유의한 변화가 없었다. 그러나 낭종성 병변에 가까운 LCS 표적 -15 dB에서는 동적영역 60 dB과 하모닉 주파수 방식에서 LCS 값이 높게 나타났다. 선형 프로브에서는 -15 dB LCS 표적에서 동적영역 40 dB, 하모닉 방식에서 명목상 값에 근접하였다. LCS관점에서 정량화된 영상의 평가의 한계와 주관적인 평가 즉 심리적인 관점에서의 ROC(Receiver Operating Characteristic) 평가의 필요성에 대해 토의하였다.

  • PDF

초음파 회절 토모그라피 영상복원 알고리즘의 분해능 분석 (The Analysis of Resolution on the Image Reconstnlction Algorithms for Ultrasonic Diffraction Tomography)

  • 구길모;황기환
    • 한국음향학회지
    • /
    • 제18권5호
    • /
    • pp.83-90
    • /
    • 1999
  • 본 논문에서는 초음파 회절 토모그라피를 위한 FBP와 BFP 영상복원 알고리즘에 관한 분해능을 연구하였다. 고정좌표계를 사용한 수정된 FBP 영상복원 알고리즘과 평면구조물에 적합한 BFP 영상복원 알고리즘을 이용하여 복원할 수 있는 토모그라픽 영상에 대한 분해능을 분석할 수 있는 모호함수를 유도하고 모의실험을 통하여 얻은 측방향 및 축방향 분해능을 분석하였다. 분석결과, FBP 영상복원 알고리즘에 대한 측방향 및 축방향의 3dB분해능은 각각 0.27파장, 0.70파장을 얻었으며, 또한 BFP 영상복원 알고리즘에 대한 측방향 및 축방향 분해능도 각각 0.39파장과 0.98파장으로 정량적으로 결정하였다. 따라서 본 연구를 통하여 수정된 FBP 영상복원 알고리즘과 BFP 영상복원 알고리즘은 회절 토모그라피를 위한 영상복원에 유용하게 이용할 수 있음을 확인하였다.

  • PDF

PZT-고분자 3-3형 초음파 센서를 이용한 3차원 수중 물체 복원 (3-D Underwater Object Restoration Using Ultrasonic Sensor Fabricated with PZT-Polymer 3-3 Type Composite)

  • 조현철;이기성;이수호;김한근;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1373-1375
    • /
    • 1997
  • In this study, 3-D underwater object restoration using ultrasonic sensor fabricated with porous PZT-Polymer 3-3 type composite are presented Using the acquired underwater object data $16{\times}16$ pixels, Modified SCL neural networks using the $16{\times}16$ low resolution image was used for underwater object restoration of $32{\times}32$ high resolution image.

  • PDF

초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과 (Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images)

  • 양정화;이경성;강관석;팽동국;최민주
    • 한국음향학회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2008
  • 초음파 진단기의 설정은 영상의 질에 영향을 준다. sonographer는 최적의 영상을 얻기 위해 초음파 영상의 질에 영향을 주는 설정 변수에 대한 효과를 이해해야 한다. 본 연구에서는 4가지 대표적인 영상 조절 변수 즉 TGC (Time Gain Control), 이득 (Gain), 주파수 (Frequency), DR (Dynamic Range)를 고려하였다. 초음파 영상의 질은 LCS (Law Contrast Sensitivity) 관점에서 정량적으로 비친 평가하였다. 실험은 임상용 초음파 진단기 (SA-9000 PRIME, Medison, Korea)를 사용하여 초음파 평가 팬텀 (539, ATS, USA)의 LCS 타겟을 영상화하였다. 영상 조절 변수의 설정을 변화하면서, 각 설정에 대한, 6개의 LCS 영상 (+15 dB, +C dB, +3 dB, -3 dB, -6 dB, -15 dB)을 취득하고, 영상에 대한 LCS픽셀 값을 계산하였다. 실험결과 TGC가 최대, Gain은 중간에서 최대사이, 주파수가 Pen모드, DR이 40-66 dB일 때 타겟 영상 (LCS)의 평균 픽셀 값이 높았다. 모든 타겟 영상에서 DR이 40 dB일 때에 LCS가 좋은 영상을 얻었다. 본 결과는 임상에서 잘 발견되는 solid lesion (+15, +6, +3 dB 타겟과 유사) 또는 cystic lesion (-15, -6, -3 dB 타겟과 비슷)이 있는 mass 평가 시 적절한 영상조절 변수 설정에 유용한 정보를 제공할 것으로 기대된다.