Development of a 3-D Position Measurement Algorithm using 2-D Image Information (2차원 영상 정보를 이용한 3차원 위치 측정 알고리즘 개발)

  • Lee, J.H.;Jung, S.H.;Kim, D.H.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.141-148
    • /
    • 2013
  • There are several problems in the conventional 2-D image processing and 3-D measurement systems. In the case of the 2-D image processing system, it is not possible to detect elevation data. In a 3-D measurement system, it requires a skillful operator and a lot of time for measuring data. Also, there exist data errors depending on operators. The limitation of detecting elevation data in the 2-D image processing system can be solved by laser diodes. In this study an algorithm that measures the accurate data in a subject face to be detected by combining laser diodes and a commercial CCD camera is developed. In the development process, a planar equation is developed using laser diodes and the equation is used to obtain a normal vector. Based on the results, an algorithm that transforms commercial CCD camera coordinates to 3-D coordinates is proposed. The completed measurement method will be applied to replace a manual measurement system for vehicle bodies and parts by an automated system.

Development of Novel Pyrone Derivative Retaining Retinoidal Anti-aging Activity with Low Skin Irritation

  • Rho, H.S;Kim, D.H;Kim, S.N;Kim, S.J;Chang, I.S;Kang, H.H;Lee, O.S
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.184-191
    • /
    • 2003
  • New pyranone derivative, 2-((3E)-4(2H, 3H, -benzo[3, 4-d] 1, 3-dioxolan-5-yl)-2-oxo-but-3-enyloxy)-5-hydroxy-4H-pyran-4-one (Seletinoid $G^{TM}$), was designed as a novel retinoid on the assumption that the pyranone ring may mimic the carboxylic acid moiety in retinoid structure. The enolic hydroxy of pyranone at five position was easily deprotonated to form an enolate. The role of enolate was similar to that of carboxylic acid. To evaluate the value of Seletinoid G as an anti-aging ingredient, various tests were performed for example inhibitory effect for MMP-l expression, anti-oxidative activity, procollagen synthesis in hairless mouse and primary skin irritation. The result of this study suggested that our new synthetic retinoid could be used as a safe material for anti-aging cosmetics.

  • PDF

Development of Smart Tape Attachment Robot in the Cold Rolled Coil with 3D Non-Contact Recognition (3D 비접촉 인식을 이용한 냉연코일 테이프부착 로봇 개발)

  • Shin, Chan-Bai;Kim, Jin-Dae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.11
    • /
    • pp.1122-1129
    • /
    • 2009
  • Recently taping robot with smart recognition function have been studied in the coil manufacturing field. Due to the difficulty of 3D surface processing from the complicated working environment, it is not easy to accomplish smart tape attachment motion with non-contact sensor. To solve these problems the applicable surface recognition algorithm and a flexible sensing device has been recommended. In this research, the fusion method between 1D displacement and 3D laser scanner is applied for robust tape attachment about cold rolled coil. With these sensors we develop a two-step exploration and the smart algorithm for the awareness of non-aligned coil's information. In the proposed robot system for tape attachment, the problem is reduced to coil's radius searching with laser displacement sensor at first, and then position and orientation detection with 3D laser scanner. To get the movement at the robot's base frame, the hand-eye compensation between robot's end effector and sensing device should be also carried out respectively. In this paper, we examine the auto-coordinate transformation method in the calibration step for the real environment usage. From the experimental results, it was shown that the taping motion of robot had a robust under the non-aligned cold rolled coil.

The Measurement of Size of the Pedicle Using 3 Dimensional Reconstruction Image in Idiopathic Scoliosis (특발성 척추측만증 환자에서의 3차원적 재구성을 이용한 척추경의 크기 측정)

  • Heo, Jae-Hee;Ahn, Myun-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.40-50
    • /
    • 2004
  • Background: This study was conducted to analyze the height and width of the pedicle of the upper and lower levels on the concave and the convex sides. In addition, we checked for the appropriate pedicle screw size which could be screwed in without complications. Materials and Methods: Taking a simple AP radiography in a standing position, 99 vertebrae on the major curve with the possibility of 3-D reconstruction were analyzed after checking the CT in a supine position of 22 idiopathic scoliosis. We measured Cobb's angle from a simple radiograph, and measured the size of the isthmus by the Inner Space 3-D Editor after 3-D reconstruction with the Inner Space 3-D program in the DICOM file transformed from CT image. We then analyzed the size of pedicles of the upper and lower levels on the concave and the convex sides by measuring the height and width of the pedicle. Results: All pedicles on the concave side were smaller than those on the convex side. Their size increased as the measurement moved from the upper to lower vertebra, except for the upper thoracic vertebra. When the width of the pedicle through 3-D reconstruction was compared with the narrowest width of the pedicle measured by using CT, the width of the pedicles through 3-D reconstruction was statistically smaller (P<0.01). Most of the pedicles were tear-drop or kidney shaped rather than cylindrical. Conclusion: These results suggest that the use of the coronal plane through 3-D reconstruction would be necessary for an accurate measurement of the size of the pedicle. It is important to pay careful attention to the screw size and the screwing method considering the pedicle shape through 3-D reconstruction.

  • PDF

Three-dimensions digital documentation and use of Three storied stone pagoda in Mulgeol-ri, Hongcheon (홍천 물걸리 삼층석탑의 3차원 디지털 기록과 활용)

  • Jun, Byung Kyu;Han, Byeong Il
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.99-110
    • /
    • 2014
  • The Three-dimensions digital documentation of cultural heritages mostly consist of drawings with 3D data, and require diverse attempts and researches. Three storied stone pagoda in Mulgeol-ri, Hongcheon underwent the disassembling repair, and its conditions before the disassembly, individual members and conditions after the preservation treatment were documented in 3D data. The 3D data of the stone pagoda before the disassembly and after the preservation treatment were comparatively analyzed by combining the member position data with the individual member data. The gaps between foundation stones became smaller after the preservation treatment, and each story made a square. The results will be used as important data in monitoring the deformation of and damage to the stone pagoda.

  • PDF

Three-Dimensional Map System Using Integral Imaging Technique (집적 영상 기술을 이용한 3차원 지도 시스템)

  • Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2799-2804
    • /
    • 2014
  • In this paper, we suggest three-dimensional information extraction map system using integral imaging technique. Integral imaging can record multiple elemental images with different perspectives using a 2D image acquisition device with lenslet array. Using these images, integral imaging can obtain 3D information and display 3D image. In this paper, the position difference between elemental images can be obtained using summation of absolute difference (SAD), and then 3D information can be extracted. Therefore, this technique can find the height information of 3D objects.

Reaction Pattern of Bacillus cereus D-11 Chitosanase on Chitooligosaccharide Alcohols

  • Gao, Xing-Ai;Jung, Woo-Jin;Kuk, Ju-Hee;Park, Ro-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.4
    • /
    • pp.358-361
    • /
    • 2009
  • The purified endochitosanase(Mw 41 kDa) from bacterium Bacillus cereus D-11 hydrolyzed chitooligomers $(GlcN)_{5-7}$ into chitobiose, chitotriose, and chitotetraose as the final products. The minimal size of the oligosaccharides for enzymatic hydrolysis was a pentamer. To further investigate the cleavage pattern of this enzyme, chitooligosaccharide alcohols were prepared as substrates and the end products of hydrolysis were analyzed by TLC and HPLC. The chitosanase split $(GlcN)_4GlcNOH$ into $(GlcN)_3+(GlcN)_1GlcNOH$, and $(GlcN)_5GIcNOH$ into $(GlcN)_4+(GlcN)_1GlcNOH$ and $(GlcN)_3+(GlcN)_2GlcNOH$. The heptamer $(GlcN)_6GlcNOH$ was split into $(GlcN)_5$ [thereafter hydrolyzed again into $(GlcN_3+(GlcN)2]+(GlcN)_1GlcNOH$, $(GlcN)_4+(GlcN)_2GlcNOH$, and $(GlcN)_3+(GlcN)_3GlcNOH$, whereas $(GlcN)_{1-3}GlcNOH$ was not hydrolyzed. The monomers GlcN and GIcNOH were never detected from the enzyme reaction. These results suggest that D-11 chitosanase recognizes three glucosamine residues in the minus position and simultaneously two residues in the plus position from the cleavage point.

Localization of Unmanned Ground Vehicle using 3D Registration of DSM and Multiview Range Images: Application in Virtual Environment (DSM과 다시점 거리영상의 3차원 등록을 이용한 무인이동차량의 위치 추정: 가상환경에서의 적용)

  • Park, Soon-Yong;Choi, Sung-In;Jang, Jae-Seok;Jung, Soon-Ki;Kim, Jun;Chae, Jeong-Sook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.7
    • /
    • pp.700-710
    • /
    • 2009
  • A computer vision technique of estimating the location of an unmanned ground vehicle is proposed. Identifying the location of the unmaned vehicle is very important task for automatic navigation of the vehicle. Conventional positioning sensors may fail to work properly in some real situations due to internal and external interferences. Given a DSM(Digital Surface Map), location of the vehicle can be estimated by the registration of the DSM and multiview range images obtained at the vehicle. Registration of the DSM and range images yields the 3D transformation from the coordinates of the range sensor to the reference coordinates of the DSM. To estimate the vehicle position, we first register a range image to the DSM coarsely and then refine the result. For coarse registration, we employ a fast random sample matching method. After the initial position is estimated and refined, all subsequent range images are registered by applying a pair-wise registration technique between range images. To reduce the accumulation error of pair-wise registration, we periodically refine the registration between range images and the DSM. Virtual environment is established to perform several experiments using a virtual vehicle. Range images are created based on the DSM by modeling a real 3D sensor. The vehicle moves along three different path while acquiring range images. Experimental results show that registration error is about under 1.3m in average.

Stereoscopic Conversion of Monoscopic Video using Edge Direction Histogram (에지 방향성 히스토그램을 이용한 2차원 동영상의 3차원 입체변환기법)

  • Kim, Jee-Hong;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.8C
    • /
    • pp.782-789
    • /
    • 2009
  • In this paper, we propose an algorithm for creating stereoscopic video from a monoscopic video. Parallel straight lines in a 3D space get narrower as they are farther from the perspective images on a 2D plane and finally meet at one point that is called a vanishing point. A viewer uses depth perception clues called a vanishing point which is the farthest from a viewer's viewpoint in order to perceive depth information from objects and surroundings thereof to the viewer. The viewer estimates the vanishing point with geometrical features in monoscopic images, and can perceive the depth information with the relationship between the position of the vanishing point and the viewer's viewpoint. In this paper, we propose a method to estimate a vanishing point with edge direction histogram in a general monoscopic image and to create a depth map depending on the position of the vanishing point. With the conversion method proposed through the experimental results, it is seen that stable stereoscopic conversion of a given monoscopic video is achieved.